• Title/Summary/Keyword: C-scan

Search Result 782, Processing Time 0.025 seconds

Delayed Transfer of Major Trauma Patients Under the Current Emergency Medical System in Korea (현재의 국내 응급의료체계에서 중증외상환자의 이송 지연)

  • Jung, Kyoung-Won;Jang, Jeong-Moon;Kim, Ji-Young;Baek, Suk-Ja;Song, Seo-Young;Gang, Chan-Suk;Lee, Kug-Jong
    • Journal of Trauma and Injury
    • /
    • v.24 no.1
    • /
    • pp.25-30
    • /
    • 2011
  • Purpose: Major trauma patients should be transferred to a definitive care facility as early as possible because prompt management will prevent death. This study was designed to discover the obstacles leading to delayed transfers under the current emergency medical system in Korea and whether there are any negative outcomes associated with conducting procedures at primary care hospitals prior to transferring patients to higher levels of care. Methods: The medical records of major trauma patients with an Injury Severity Score above 15 within the past year were reviewed. Patients were divided three groups as follows: (A) came directly to our emergency center, (B) were transferred without CT or MRI scan at the primary care hospital and (C) transferred with CT or MRI scans. The transfer time of each group were compared and analyzed statistically. Additionally, the number and type of imaging performed at the primary care hospital were analyzed. Results: All qualified patients (n=276) were enrolled in this study: 121 patients in group A; 104 in group B; 51 in group C. There was a statistically significant difference in the transfer time between the three groups (p-value<0.001), and 79 (28.6%) were transferred to an emergency medical center within one hour. In group C, CT or MRI scans were performed an average of 1.86 times at the primary care hospital, and the median transfer time was 4 hours 5 minutes. Conclusion: Only 28.6% of the cases in the study arrived within the golden hour at a definitive care facility. Such delays are in part the result of prolonged times at the primary care hospital for radiologic examinations, such as CT or MRI scans. Major multiple trauma patients should be transferred to a definitive care facility directly or as soon as the primary survey and the resuscitation of Advanced Trauma Life Support guideline are completed at the primary care hospital.

The Effects of Bee Venom and Melittin acupuncture solution on cPLA2, TNF-α and Calcium Concentration in RAW 264.7 Cells (봉약침액(蜂藥鍼液)과 Melittin 약침액(藥鍼液)이 RAW 264.7 Cell의 cPLA2, TNF-α 및 Calcium Concentration에 미치는 영향(影響))

  • Park, Young-eun;Song, Ho-sueb
    • Journal of Acupuncture Research
    • /
    • v.21 no.5
    • /
    • pp.179-190
    • /
    • 2004
  • Objectives : The purpose of this study was to investigate the effect of Bee Venom and Melittin acupuncture solution on the lipopolysaccharide and sodium nitroprusside- induced expression of cytosolic phospholipase $A_2$, tumor necrosis factor-${\alpha}$ and calcium concentration in RAW 264.7 cells, a murine macrophage cell line. Methods : The expression of cytosolic phospholipase $A_2$ and tumor necrosis factor-${\alpha}$ was determined by western blotting with corresponding antibodies, and the generation of intracellular calcium concentration was investigated by delta scan system in RAW 264.7 cells. Results : 1. Compared with control, expressions of lipopolysaccharide-induced cytosolic phospholipase $A_2$ were decreased significantly by $5{\mu}g/mL$ of bee venom and 5, $10{\mu}g/mL$ of melittin acupuncture solution and decreased by 0.5, $1{\mu}g/mL$ of bee venom. 2. Compared with control, expressions of sodium nitroprusside-induced phospholipase $A_2$ were decreased significantly by 0.5, 1, $5{\mu}g/mL$ of bee venom and by 5, $10{\mu}g/mL$ of melittin acupuncture solution. 3. Compared with control, expressions of lipopolysaccharide-induced tumor necrosis factor-${\alpha}$ were decreased significantly by $10{\mu}g/mL$ of melittin acupuncture solution and were not changed significantly by 0.5, 1, $5{\mu}g/mL$ of bee venom and $5{\mu}g/mL$ of melittin acupuncture solution. 4. Compared with control, expressions of sodium nitroprusside-induced tumor necrosis factor-${\alpha}$ were decreased significantly by 1, $5{\mu}g/mL$ of bee venom and 5, $10{\mu}g/mL$ of melittin acupuncture solution and decreased by $0.5{\mu}g/mL$ of bee venom 5. Compared with control, lipopolysaccharide-induced intracellular calcium concentrations were decreased by 0.5, 1, $5{\mu}g/mL$ of bee venom and $10{\mu}g/mL$ of melittin acupuncture solution and increased by $5{\mu}g/mL$ of melittin acupuncture solution. 6. Compared with control, sodium nitroprusside-induced intracellular calcium concentrations were decreased by 0.5, 1, $5{\mu}g/mL$ of bee venom and 5, $10{\mu}g/mL$ of melittin acupuncture solution.

  • PDF

A Study on the Head and Neck Posture Related to Cervical Curvature in Patients with Craniomandibular Disorders (경추만곡도를 이용한 두개하악장애에 환자의 두경부자세에 관한 연구)

  • Min-Shin;Kyung-Soo Han
    • Journal of Oral Medicine and Pain
    • /
    • v.20 no.2
    • /
    • pp.361-376
    • /
    • 1995
  • The purpose of this study was to investigate the relationship between the head and neck postre and the cervical curvature, especially in forward head postrue(FHP). Sixty patients with craniomandibular disorders and thirty dental students without any signs and symptoms of craniomandibular disordres participated in this study as patient groups and sa control group, respectively. The author evaluated the head and neck posture of all subjects by plumb line and CROM( Cervical Ragne of Motion), and had taken cephaograph in natural head position. On the cephalograph the angle of cervical inclination formed by true horizntal plane and 4th cervical vertebra(C4) and the radius of cervical curvature from C1 to C5 were measured. A specially designed ruler was used for measuring cervical curvature. Occlusal contac number and force with T-scan system, electromygraphic activity of cervical muscles with Bio-EMG, and distance of freeway space with Bio-ECN were recorded, respectively. The collected data were processed by SAS/STAT progrm. The obtained results were as follows : 1. In subjects with longer radius which was less cervical curvature, head positioned more anteriorly than subjects with smaller radius, and they showed slightly straight cervical vertebra. 2. Between the patients and the control group, there were no differences in cervical curvature, in forward head position by plumb line and in CROM. But the patient group had a greater cervical inclination than the control group had. 3. There were positive correlation between cervical curvature and forward head position by plumbline,between forward head position y plumb line and that by CROM in patient group. The cervical inclination, however, had negative correlation with cervical curvature, and with forward head postion by plumb line, respectively. 4. In case of showing more cervical curvature and more forward head position by plumb line the head position was defined as forward head posture. In patient group, subjects without forward head posture showed greater posterior teeth contact force than subjects with forward head posture, but in control group, there were no difference between the two subjects. 5. There were higher electromyographic activity in almost all muscles and smaller freeway space in induced forward head posture than those in natural head position in subjects without forward head posture. In conclusion, head position of patients with craniomandibular disorders were not more anterior than that of normal control person, but they had tendency to head extension. From the result of this study, forward head posture could be defined as posterior rotation of upper cervical segment with a straight lower cercial segment due to loss of normal lordosis.

  • PDF

Unresolving Pneumonia (치료에 대한 반응이 없는 폐렴)

  • Bang, Do Seok;Jung, In Sung;Kang, Ki Man;Park, Bum Chul;Yoon, Young Gul;Kim, Jae Su;Park, Yol;Lee, Sung Hoon;Hong, Young Chul;Ko, Kyoung Tae;Park, Sang Min;Na, Dong Jib
    • Tuberculosis and Respiratory Diseases
    • /
    • v.57 no.6
    • /
    • pp.604-608
    • /
    • 2004
  • A 47-year-old-man was admitted to the emergency department with dyspnea, right pleuritic pain, and high fevers for 3 days. He had a nonproductive cough that exacerbated the chest pain. A clinical examination revealed distressed and slightly tachypneic patient, with blood pressure of 110/90 mmHg, temperature of $39^{\circ}C$, pulse of 90 beats/min, respiratory rate of 24 breaths/min. A chest examination showed significantly diminished breath sounds in the right lung with dullness to percussion. Laboratory investigation demonstrated leukocytosis and a raised C-reactive protein. The results of arterial blood gas analysis revealed moderate hypoxemia. A radiograph and a CT scan of the chest showed extensive consolidation with multifocal low densities, and pleural effusion in the right lung. A diagnostic thoracentesis revealed straw-colored fluid, which was found to be a neutrophil-predominant exudate. At 7 days after admission, the clinical symptoms had not improved and the temperature was still $39^{\circ}C$ despite the aggressive therapy of community-acquired pneumonia. After comprehensive history taking, we realized then that he accidentally aspirated kerosene while siphoning from fuel tank to put into the boiler 3 days ago. Bronchoscopy with bronchial washings could be successful in establishing the diagnosis of hydrocarbon pneumonitis by demonstration of a high lipid-laden macrophage index. Thereafter, the symptoms and radiographic opacities gradually improved, and he was discharged several days later.

A Major Locus for Quantitatively Measured Shank Skin Color Traits in Korean Native Chicken

  • Jin, S.;Lee, J.H.;Seo, D.W.;Cahyadi, M.;Choi, N.R.;Heo, K.N.;Jo, C.;Park, H.B.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.29 no.11
    • /
    • pp.1555-1561
    • /
    • 2016
  • Shank skin color of Korean native chicken (KNC) shows large color variations. It varies from white, yellow, green, bluish or grey to black, whilst in the majority of European breeds the shanks are typically yellow-colored. Three shank skin color-related traits (i.e., lightness [$L^*$], redness [$a^*$], and yellowness [$b^*$]) were measured by a spectrophotometer in 585 progeny from 68 nuclear families in the KNC resource population. We performed genome scan linkage analysis to identify loci that affect quantitatively measured shank skin color traits in KNC. All these birds were genotyped with 167 DNA markers located throughout the 26 autosomes. The SOLAR program was used to conduct multipoint variance-component quantitative trait locus (QTL) analyses. We detected a major QTL that affects $b^*$ value (logarithm of odds [LOD] = 47.5, $p=1.60{\times}10^{-49}$) on GGA24 (GGA for Gallus gallus). At the same location, we also detected a QTL that influences $a^*$ value (LOD = 14.2, $p=6.14{\times}10^{-16}$). Additionally, beta-carotene dioxygenase 2 (BCDO2), the obvious positional candidate gene under the linkage peaks on GGA24, was investigated by the two association tests: i.e., measured genotype association (MGA) and quantitative transmission disequilibrium test (QTDT). Significant associations were detected between BCDO2 g.9367 A>C and $a^*$ ($P_{MGA}=1.69{\times}10^{-28}$; $P_{QTDT}=2.40{\times}10^{-25}$). The strongest associations were between BCDO2 g.9367 A>C and $b^*$ ($P_{MGA}=3.56{\times}10^{-66}$; $P_{QTDT}=1.68{\times}10^{-65}$). However, linkage analyses conditional on the single nucleotide polymorphism indicated that other functional variants should exist. Taken together, we demonstrate for the first time the linkage and association between the BCDO2 locus on GGA24 and quantitatively measured shank skin color traits in KNC.

Vulnerability Analysis and Detection Mechanism against Denial of Sleep Attacks in Sensor Network based on IEEE 802.15.4 (IEEE 802.15.4기반 센서 네트워크에서 슬립거부 공격의 취약성 분석 및 탐지 메커니즘)

  • Kim, A-Reum;Kim, Mi-Hui;Chae, Ki-Joon
    • The KIPS Transactions:PartC
    • /
    • v.17C no.1
    • /
    • pp.1-14
    • /
    • 2010
  • IEEE 802.15.4[1] has been standardized for the physical layer and MAC layer of LR-PANs(Low Rate-Wireless Personal Area Networks) as a technology for operations with low power on sensor networks. The standardization is applied to the variety of applications in the shortrange wireless communication with limited output and performance, for example wireless sensor or virtual wire, but it includes vulnerabilities for various attacks because of the lack of security researches. In this paper, we analyze the vulnerabilities against the denial of sleep attacks on the MAC layer of IEEE 802.15.4, and propose a detection mechanism against it. In results, we analyzed the possibilities of denial of sleep attacks by the modification of superframe, the modification of CW(Contention Window), the process of channel scan or PAN association, and so on. Moreover, we comprehended that some of these attacks can mount even though the standardized security services such as encryption or authentication are performed. In addition to, we model for denial of sleep attacks by Beacon/Association Request messages, and propose a detection mechanism against them. This detection mechanism utilizes the management table consisting of the interval and node ID of request messages, and signal strength. In simulation results, we can show the effect of attacks, the detection possibility and performance superiorities of proposed mechanism.

Direct Bonding of SillSiO2/Si3N4llSi Wafer Fairs with a Fast Linear Annealing (선형가열기를 이용한 SillSiO2/Si3N4llSi 이종기판쌍의 직접접합)

  • 이상현;이상돈;송오성
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.4
    • /
    • pp.301-307
    • /
    • 2002
  • Direct bonded SOI wafer pairs with $Si ll SiO_2/Si_3N_4 ll Si$ the heterogeneous insulating layers of SiO$_2$-Si$_3$N$_4$are able to apply to the micropumps and MEMS applications. Direct bonding should be executed at low temperature to avoid the warpage of the wafer pairs and inter-diffusion of materials at the interface. 10 cm diameter 2000 ${\AA}-SiO_2/Si(100}$ and 560 $\AA$- ${\AA}-Si_3N_4/Si(100}$ wafers were prepared, and wet cleaned to activate the surface as hydrophilic and hydrophobic states, respectively. Cleaned wafers were pre- mated with facing the mirror planes by a specially designed aligner in class-100 clean room immediately. We employed a heat treatment equipment so called fast linear annealing(FLA) with a halogen lamp to enhance the bonding of pre mated wafers We kept the scan velocity of 0.08 mm/sec, which implied bonding process time of 125 sec/wafer pairs, by varying the heat input at the range of 320~550 W. We measured the bonding area by using the infrared camera and the bonding strength by the razor blade clack opening method, respective1y. It was confirmed that the bonding area was between 80% and to 95% as FLA heat input increased. The bonding strength became the equal of $1000^{\circ}C$ heat treated $Si ll SiO_2/Si_3N_4 ll Si$ pair by an electric furnace. Bonding strength increased to 2500 mJ/$\textrm{m}^2$as heat input increased, which is identical value of annealing at $1000^{\circ}C$-2 hr with an electric furnace. Our results implies that we obtained the enough bonding strength using the FLA, in less process time of 125 seconds and at lowed annealing temperature of $400^{\circ}C$, comparing with the conventional electric furnace annealing.

Characterization of Water Absorption by CFRP Using Air-Coupled Ultrasonic Testing (공기결합 초음파탐상에 의한 CFRP 복합재의 흡습 특성 평가)

  • Lee, Joo-Min;Lee, Joo-Sung;Kim, Yong-Kwon;Park, Ik-Keun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.2
    • /
    • pp.155-164
    • /
    • 2014
  • Carbon-fiber-reinforced plastic (CFRP) composites are increasingly being used in a variety of industry applications, such as aircraft, automobiles, and ships because of their high specific stiffness and high specific strength. Aircraft are exposed to high temperatures and high humidity for a long duration during flights. CFRP materials of the aircraft can absorb water, which could decrease the adhesion strength of these materials and cause their volumes to change with variation in internal stress. Therefore, it is necessary to estimate the characteristics of CFRP composites under actual conditions from the viewpoint of aircraft safety. In this study air-coupled ultrasonic testing (ACUT) was applied to the evaluation of water absorption properties of CFRP composites. CFRP specimens were fabricated and immersed in distilled water at $75^{\circ}C$ for 30, 60, and 120 days, after which their ultrasonic images were obtained by ACUT. The water absorption properties were determined by quantitatively analyzing the changes in ultrasonic signals. Further, shear strength was applied to the specimens to verify the changes in their mechanical properties for water absorption.

Estimating soils properties using NIRS to assess amendments in intensive horticultural production

  • Pena, Francisco;Gallardo, Natalia;Campillo, Carmen Del;Garrido, Ana;Cabanas, Victor Fernandez;Delgado, Antonio
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1615-1615
    • /
    • 2001
  • During the past ten years, Near Infrared Spectroscopy has been successfully applied to the analysis of a great variety of agriculture products. Previous works (Morra et al., 1991; Salgo et al., 1998) have shown the potential of this technology for soil analysis, estimating different parameters just with one single scan. The main advantages of NIR applications in soils are the speed of response, allowing the increase of the number of samples analysed to define a particular soil, and the instantaneous elaboration of recommendations for fertilization and soil amendment. Another advantage is to avoid the use of chemical reagents at all, being an environmentally safe technique. In this paper, we have studied a set of 129 soil samples selected from representative glasshouse soils from Southern Spain. The samples were dried, milled, and sieved to pass a 2 mm sieve and then analysed for organic carbon, total nitrogen, inorganic nitrogen (nitrate ammonium), hygroscopic humidity, pH and electrical conductivity in the 1:1 extract. NIR spectra of all samples were obtained in reflectance mode using a Foss NIR Systems 6500 spectrophotometer equipped with a spinning module. Calibration equations were developed for seven analytical parameters (ph, Total nitrogen, organic nitrogen, organic carbon, C/N ratio and Electric Conductivity). Preliminary results show good correlation coefficients and standard errors of cross validation in equations obtained for Organic Carbon, Organic Nitrogen, Total Nitrogen and C/N ratio. Calibrations for nitrates and nitrites, ammonia and electric conductivity were not acceptable. Calibration obtained for pH had an acceptable SECV, but the determination coefficient was found very poor probably due to the reduced range in reference values. Since the estimation of Organic Carbon and C/N ratio are acceptable NIIRS could be used as a fast method to assess the necessity of organic amendments in soils from Mediterranean regions where the low level of organic matter in soils constitutes an important agronomic problem. Furthermore, the possibility of a single and fast estimation of Total Nitrogen (tedious determination by modifications of the Kjeldahl procedure) could provide and interesting data to use in the estimation of nitrogen fertilizer rates by means of nitrogen balances.

  • PDF

Chronic Hereditary Tyrosinemia Type I with Novel Mutation in FAH Gene (FAH gene novel mutation을 가진 만성형 Hereditary tyrosinemia 1형)

  • Yang, Sungmin;Choi, Hyo Won;Kang, Yun Koo;Lee, Jin-Sung;Namgoong, Mee Kyung
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.20 no.2
    • /
    • pp.55-62
    • /
    • 2020
  • A 22-month-old girl who had taken iron supplements due to iron deficiency anemia, presented bloody mucoid stool for one month. She had a bruise at the right periorbital area due to minor trauma and hepatosplenomegaly. Laboratory studies showed anemia, thrombocytopenia, elevated alkaline phosphatase (ALP), hypophosphatemia, decreased haptoglobin, hypocomplementemia, negative direct/indirect Coomb's test, normal vitamin D3 level and high PTHi. Wrist x-ray showed no signs of rickets. The abdominal ultrasound showed only accessory spleen. Tandem mass spectrometry was normal. During follow up, bloody stool regressed after seven days of withdrawal of iron supplement and cow milk, and the total CO2 level had been within 15-20 mEq/L with normal anion gap. NGS (next generation sequencing) panel test for evaluation of renal tubular acidosis showed negative results. After low dose steroid and vitamin D supplements under the impression of hypocomplementemic vasculitis, thrombocytopenia, C3/C4, decreased haptoglobin, and elevated ALP level became normal. At 57 months of age, laboratory findings showed elevated liver enzyme, ALP and gamma-glutamyl transferase again. And liver cirrhosis with splenomegaly and diffuse renal disease were reported with abdomen CT scan. Liver biopsy reported macro- and micronodular cirrhosis. Urine organic acid profile showed elevated succinylacetone level. Whole exome sequencing revealed novel compound heterozygous mutations (NM_00137.2:c.107T>C, NM_00137, 2:c.614T>C) in FAH gene and confirmed by Sanger sequencing. Consequently, the patient was diagnosed as chronic hereditary tyrosinemia type I. She started low phenylalanine/tyrosine diet and nitisinone treatment. Our case had presented symptoms very slowly, which is the first case of chronic tyrosinemia type I in South Korea.