• Title/Summary/Keyword: C-implant

Search Result 475, Processing Time 0.027 seconds

Fabrication and Evaluation of NMOS Devices (NMOS 소자의 제작 및 평가)

  • 이종덕
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.16 no.4
    • /
    • pp.36-46
    • /
    • 1979
  • Using N_ Ch silicon gate technology . the capacitors and transistors with various dimenssion were fabricated. Although the applied process was somewhat standard the conditions of ion implantation for the gate were varied by changing the implant energies from 30keV to 60keV for B and from 100 keV to 175keV for P . The doses of the implant also changed from 3 $\times$ 10 /$\textrm{cm}^2$ to 5 $\times$ 10 /$\textrm{cm}^2$ for B and from 4$\times$ 10 /$\textrm{cm}^2$ to 7 $\times$ 10 /$\textrm{cm}^2$ for P . The D. C. parameters such as threshold voltage. substrate doping level, the degree of inversion, capacitance. flat band voltage, depletion layer width, gate oxide thickless, surface states, motile charge density, electron mobility. leakage current were evaluated and also compared with the corresponing theoretical values and / or good numbers for application. The threshold voltages measured using curve tracer and C-V plot gave good agreements with the values calculated from SUPREM II which has been developed by Stanford University process group. The threshold vol tapes with back gate bias were used to calculate the change of the substrate doping level. The measured subthreshold slope enabled the prediction of the degree of inversion The D. C. testing results suggest the realized capacitors and transistors are suited for the memory applications.

  • PDF

Influence of tungsten carbide/carbon coating of implant-abutment screw on screw loosening (임플랜트 지대주 나사의 텅스텐 카바이드/탄소 코팅이나사풀림에 미치는 영향)

  • Park, Jae-Kyoung;Jeong, Chang-Mo;Jeon, Young-Chan;Yoon, Ji-Hoon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.137-147
    • /
    • 2008
  • Statement of problem: Dental implant procedure has been recognized as a very effective treatment to rehabilitate fully or partially edentulous patients. However, mechanical failures such as screw loosening, screw fracture have been still reported frequently. Purpose: The purpose of this study was to evaluate the influence of tungsten carbide/carbon coating, which has superior hardness and frictional wear resistance, on implant-abutment screw loosening of three different joint connections after one million cyclic loading. Material and methods: The values of detorque before and after loading were measured in three different joint connections (Osstem Implant, Korea), one external butt joint, US II implant system and two internal cones, SS II and GS II system. The values of detorque before loading was analyzed by one-way ANOVA, and two-way ANOVA and Scheffe' test were performed for the value of detorque after loading. Results: 1. The values of initial detorque of tungsten carbide/carbon coated Ti alloy screw were smaller those of Ti alloy screw (P<.01), and there were no differences among implant systems in each screw (P>.05). 2. In comparison of loss rate of detorque value after cyclic loading, US II system was greater than SS II and GS II system but there was no difference between SS II and GS II system (P<.01). 3. Loss rates of detorque value after cyclic loading decreased consistently at tungsten carbide/carbon coated Ti alloy screw comparing with Ti alloy screw in all implant systems (P<.01), and there were no differences among three systems in reduction of loss rates by using tungsten carbide/carbon coated Ti alloy screw (P>.05). Conclusion: Tungsten carbide/carbon coating to increase preload with reduction of friction resistance was a effective way to decrease screw loosening by functional loading.

Behavioral Characteristics of Bos indicus Cattle after a Superovulatory Treatment Compared to Cows Synchronized for Estrus

  • Jimenez, A.;Bautista, F.;Galina, C.S.;Romero, J.J.;Rubio, I.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.24 no.10
    • /
    • pp.1365-1371
    • /
    • 2011
  • The intensity and duration of sexual behavior in Bos indicus was assessed through the continuous observation of sexual receptivity. Two groups of cows were formed: only synchronized (n = 50) and other group further superovulated (n = 20). An intravaginal implant that released progesterone over 9 d was used. After removing the implant, 25 mg of $PGF_{2{\alpha}}$ was administered. In the superovulated group, the administration of 280 mg (Follicle stimulant hormone) FSH-P1 per cow with a decreasing dosage over 4 d was utilized. In both groups, behavioral observations began at the moment of implant removal. Sexual behavior was analyzed using a Kruskal-Wallis test to compare the mean of hours in estrus, effective mountings and number of mounts/hour during estrus. A nonparametric survival analysis was performed using the time in two ways: i) when an event happened it was placed in a 24 h timeframe and, ii) the time of observation in continuous form (96 h) assessing the difference between curves by the log rank test Chi-square. The only significant difference was the number of mounts/h during receptivity (p<0.05). In the superovulated group three periods of sexual activity during the day were identified, with these events being of greater frequency and duration than the synchronized group (p = 0.02); besides, the superovulated group began estrus before the synchronized group (p = 0.0035) when using the total period. In a simulation study, when the number of observations went from two (06:00-18:00) to three periods (06:00, 12:00 and 18:00) cows detected accurately (<6 h after the onset) increased more than 20%. The results show that superovulated cows presented greater intensity and duration of sexual activity in contrast with only synchronized animals.

Three-dimensional finite element analysis of the deformation of the human mandible: a preliminary study from the perspective of orthodontic mini-implant stability

  • Baek, Sun-Hye;Cha, Hyun-Suk;Cha, Jung-Yul;Moon, Yoon-Shik;Sung, Sang-Jin
    • The korean journal of orthodontics
    • /
    • v.42 no.4
    • /
    • pp.159-168
    • /
    • 2012
  • Objective: The aims of this study were to investigate mandibular deformation under clenching and to estimate its effect on the stability of orthodontic mini-implants (OMI). Methods: Three finite element models were constructed using computed tomography (CT) images of 3 adults with different mandibular plane angles (A, low; B, average; and C, high). An OMI was placed between #45 and #46 in each model. Mandibular deformation under premolar and molar clenching was simulated. Comparisons were made between peri-orthodontic mini-implant compressive strain (POMI-CSTN) under clenching and orthodontic traction forces (150 g and 200 g). Results: Three models with different mandibular plane angles demonstrated different functional deformation characteristics. The compressive strains around the OMI were distributed mesiodistally rather than occlusogingivally. In model A, the maximum POMI-CSTN under clenching was observed at the mesial aspect of #46 (1,401.75 microstrain [${\mu}E$]), and similar maximum POMI-CSTN was observed under a traction force of 150 g (1,415 ${\mu}E$). Conclusions: The maximum POMI-CSTN developed by clenching failed to exceed the normally allowed compressive cortical bone strains; however, additional orthodontic traction force to the OMI may increase POMI-CSTN to compromise OMI stability.

Acellular Dermal Matrix as a Core Strut for Projection in Nipple Reconstruction: Approaches for Three Different Methods of Breast Reconstruction

  • Park, Gui-Yong;Yoon, Eul-Sik;Cho, Hee-Eun;Lee, Byung-Il;Park, Seung-Ha
    • Archives of Plastic Surgery
    • /
    • v.43 no.5
    • /
    • pp.424-429
    • /
    • 2016
  • Background The objective of this paper was to describe a novel technique for improving the maintenance of nipple projection in primary nipple reconstruction by using acellular dermal matrix as a strut in one of three different configurations, according to the method of prior breast reconstruction. The struts were designed to best fill the different types of dead spaces in nipple reconstruction depending on the breast reconstruction method. Methods A total of 50 primary nipple reconstructions were performed between May 2012 and May 2015. The prior breast reconstruction methods were latissimus dorsi (LD) flap (28 cases), transverse rectus abdominis myocutaneous (TRAM) flap (10 cases), or tissue expander/implant (12 cases). The nipple reconstruction technique involved the use of local flaps, including the C-V flap or star flap. A $1{\times}2-cm$ acellular dermal matrix was placed into the core with O-, I-, and L-shaped struts for prior LD, TRAM, and expander/implant methods, respectively. The projection of the reconstructed nipple was measured at the time of surgery and at 3, 6, and 9 months postoperatively. Results The nine-month average maintenance of nipple projection was $73.0%{\pm}9.67%$ for the LD flap group using an O-strut, $72.0%{\pm}11.53%$ for the TRAM flap group using an I-strut, and $69.0%{\pm}10.82%$ for the tissue expander/implant group using an L-strut. There were no cases of infection, wound dehiscence, or flap necrosis. Conclusions The application of an acellular dermal matrix with a different kind of strut for each of 3 breast reconstruction methods is an effective addition to current techniques for improving the maintenance of long-term projection in primary nipple reconstruction.

Surface Compatibility and Electrochemical Behaviors of Zirconia Abutment for Prosthodontics (보철용 지르코니아 어버트먼트의 표면적합도와 전기화학적 거동)

  • Park, K.H.;Jeong, Y.H.;Kim, W.G.;Choe, H.C.;Kim, M.S.
    • Journal of Surface Science and Engineering
    • /
    • v.42 no.1
    • /
    • pp.41-46
    • /
    • 2009
  • The fit between dental implant fixture and zirconia abutment is affected by many variables during the fabrication process by CAD/CAM program and milling working. The purpose of this study was to evaluate the surface compatibility and electrochemical behaviors of zirconia abutment for prosthodontics. Zirconia abutments were prepared and fabricated using zirconia block and milling machine. For stabilization of zirconia abutments, sintering was carried out at $1500^{\circ}F$ for 7 hrs. The specimens were cut and polished for gap observation. The gap between dental implant fixture and zirconia abutment was observed using field-emission scanning electron microscopy (FE-SEM). The hardness and corrosion resistance of zirconia abutments were observed with vickers hardness tester and potentiostat. The gap between dental implant fixture and zirconia abutment was $5{\sim}12{\mu}m$ for small gap, and $40{\sim}60{\mu}m$ for large gap. The hardness of zirconia surface was 1275.5 Hv and showed micro-machined scratch on the surface. The corrosion potentials of zirconia abutment/fixture was .290 mV and metal abutment/fixture was .280 mV, whereas $|E_{pit}-E_{corr}|$ of zirconia abutment/fixture (172 mV) was higher than that of metal abutment/fixture (150 mV). The corrosion morphology of metal abutment/fixture showed the many pit on the surface in compared with zirconia abutment/fixture.

Stress Analysis of Total Knee System Depending on Implant Materials and Fixation Methods (인공무릎관절에 있어서 임플란트의 재료 및 고정방법에 따른 응력분석)

  • Cho, C.H.;Cho, Y.K.;Choi, J.B.;Choi, K.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.484-488
    • /
    • 1997
  • Three-dimensional finite element analyses were used to compare the stress distribution and the stability of the fixation among seven different tibial components and to investigate the effect due to implant materials in total knee arthroplasty. The components included an intact tibia(Type I), Cemented Cobalt-Chromium tibial tray implanted with a PMMA cemented Co-Cr stem(Type II), Cemented Co-Cr tibial tray with a uncemented Co-Cr stem(Type III), Cemented Ultra High Molecular Weight Polyethylene (UHMWPE) tibial tray with a cemented UHMWPE stem (Type IV), Cemented UHMWPE tray with a uncemented UHMWPE stem(Type V), Cemented Co-Cr tray without a stem(Type VI), and Cemented UHMWPE tray without a stem(Type VII). Uncemented components were assumed to have complete bony in growth and a rigid state of fixation between component and bone. The interface between bone/cement/component of cemented components was also assumed to be fully bonded. Bi-condylar forces were applied. The results indicated that Uncemented stem components provided lower bone stress shielding and stress concentration. The UHMWPE tray and stem component showed better agreement with the intact tibia than the Co-Cr Alloy tray and stem components. If the implant tray can be fixed firmed without a stem, Cemented PE tray without a stem(Type VII) may be recommended to give the best characteristics in the sense of stress distribution and stability.

  • PDF

A study on the effect of tooth ash and hydroxylapatite root implantation on preservation of alveolar ridge (치아회분(齒牙灰粉) 및 인공(人工) 수산화(水酸化) 아파타이트 치근(齒根)이 치조제(齒槽堤) 유지(維持)에 미치는 영향(影響))

  • Hong, Soon-Yong;Yoon, Chang-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.23 no.1
    • /
    • pp.13-37
    • /
    • 1985
  • Biocompatibility of dense synthetic hydroxylapatite is well known and the direct bond with adjacent bone developed. The purpose of this study was to evaluate the potential of clinical application of tooth ash for preservation of alveolar ridge. For this purpose the author performed an experimental implantation of the particulate and root form of both pure dense hydroxylapatite and tooth ash in alveolar sockets immediately after extraction. The pure dense hydroxylapatite was particulate form and root form made by Calciteck Inc. The tooth ash was prepared by incineration at $950^{\circ}C$, and the syrindrical form of the tooth ash was sintered and trimmed to fit the size of the each extraction socket of 10 mongrel dogs. After sugery the clinical, roentgenographical, and histological observation was carried out. The results obtained were as follows; 1. Clinical observation disclosed no dehiscence and exfoliation due to tissue rejection. 2. Vertical resorption of alveolar bone occurred in all experimental sockets as well as the control sites on the roentgenograph. 3. Osteoclastic activity appeared at the inner surfaces of the crestal alveolar bone on the 1st week but disappeared on the 2nd week. 4. There were macrophages in the particulate form on the 1st and 2nd week after surgery but no macrophages appered in the root form. S. New bone formation was developed from the bony wall of experimental sockets and grew to bond with the implant materials. In particulate form the new bone formation did not occur in central zone independently. 6. Tooth ash implant sites were covered with the newly formed bony trabeculation from third week, but Calcitite particles were covered with soft tissue. 7. Generally the healing occurred more rapidly in control sites than in implant sites.

  • PDF

Fully Porous and Porous Surfaced Ti-6Al-4V Implants Fabricated by Electro-Discharge-Sintering: (1) Fabrication Method and Fundamental Characteristics (전기방전소결에 의해 제조된 다공성 및 다공성 표면을 갖는 Ti-6Al-4V 임플란트 : (1) 제조방법 및 기본적 특성)

  • Hyun, C. Y.;Huh, J. K.;Lee, W. H.
    • Journal of Powder Materials
    • /
    • v.12 no.5 s.52
    • /
    • pp.325-331
    • /
    • 2005
  • Implant prototypes with various porosities were fabricated by electro-discharge-sintering of atomized spherical Ti-6Al-4V powders. Single pulse of 0.75 to 2.0 kJ/0.7 g-powder, using 150, 300, and $450{\mu}F$ capacitors was applied to produce a fully porous and porous surfaced implant compact. The solid core formed in the center of the compact after discharge was composed of acicular ${\alpha}+{\beta}$ grains and porous layer consisted of particles connected in three dimensions by necks. The solid core and neck sizes increased with an increase in input energy and capacitance. On the other hand, pore volume decreased with increased capacitance and input energy due to the formation of solid core. Capacitance and input energy are the only controllable discharge parameters even though the heat generated during a discharge is the unique parameter that determines the porosity of compact. It is known that electro-discharge-sintering of spherical Ti-6Al-4V powders can efficiently produce fully-porous and porous surfaced Ti-6Al-4V implants with various porosities in a short time less then 400 isec by manipulating the discharging condition such as input energy and capacitance including powder size.