• Title/Summary/Keyword: C-스캔

Search Result 202, Processing Time 0.028 seconds

Limitations of 99mTc-DMSA scan in diagnosing acute pyelonephritis in children (이해관계 선언)

  • Kim, Byung Gee;Kwak, Jae Ryoung;Park, Ji Min;Pai, Ki Soo
    • Clinical and Experimental Pediatrics
    • /
    • v.53 no.3
    • /
    • pp.408-413
    • /
    • 2010
  • Purpose : We aimed to prove the relative limitation of $^{99m}Tc-DMSA$ scintigraphy (DMSA) compared to computed tomography (CT) in diagnosing acute pyelonephritis (APN) in children. Methods : Since September 2006, after a 64-channel CT was imported, 10 DMSA false-negative patients have been identified: these patients underwent a CT scan for acute abdomen or acute febrile symptoms and were diagnosed as having APN; however, their DMSA scans were clear. We focused on these 10 DMSA false-negative patients and analyzed their clinical findings and CT results. We used Philips Brilliance Power 64-channel CT scanner for the CT scan and Siemens Orbitor Nuclear Camera 60 Hz for the DMSA scan. Results : The 10 DMSA false-negative patients were mostly males (80%) and infants (80%). They had fever for a mean of 1.1-day duration before admission and showed increase in acute reactants: leukocyte, erythrocyte sedimentation rate, and C-reactive protein. The CT findings of renal lesions were focal in 6 (60%) cases and diffuse in 4 (40%) cases, and most of the lesions were unilateral in 80% of patients. CT proved that 22 renal lesions were neglected by DMSA. Differential renal function test by DMSA was also of no use in the evaluation of renal lesions. Conclusion : In this study, DMSA scan showed limitation in finding renal cortical lesions of CT-proven APN patients. DMSA false-negative results seem to occur at early-phase disease of infantile age, but more prospective studies are needed to determine the reasons and their prevalence.

Improvement of Flexible Zerotree Coder by Efficient Transmission of Wavelet Coefficients (웨이블렛 계수의 효율적인 전송에 따른 가변제로트리코더의 성능개선)

  • Joo, Sang-Hyun;Shin, Jae-Ho
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.36C no.9
    • /
    • pp.76-84
    • /
    • 1999
  • EZW proposed by Shapiro is based on a zerotree constructed in a way that a parent coefficient in a subband is related to four child coefficients in the next finer subband of similar orientation. This fixed treeing based on 1-to-4 parent-child is suitable to exploti hierachical correlations among subbands but not to exploit spatial correlations within a subband. A new treeing by Joo, et al. is suggested to simulatneously exploit those two correlatins by extending parent-child relationship in a flexible way. The flexible treeing leads to increasing the number of symbols and lowering entorpy comparing to the fixed treeing, and therefore a better compression can be resulted. In this paper, we suggest two techniques to suppress the increasing of symbols. First, a probing bit is generated to avoid redundant scan for insignivicant coefficients. Second, since all subbands do not always require the same kind of symbol-set, produced symbols are re-symbolized into binary codes according to a pre-defined procedure. Owing to those techniques, all symbols are generated as binary codes. The binary symbols can be entropy-coded by an adaptive arithmetic coding. Moerover, the binary symbol stream can give comparatively good performances without help of additional entropy coding. Our proposed coding scheme is suggested in two modes: binary coding mode and arithmetic coding mode. We evaluate the effectivenessof our modifications by comparing with the original EZW.

  • PDF

Simulation of Energy Resolution of Time of Flight System for Measuring Positron-annihilation induced Auger Electrons (양전자 소멸 Auger 전자 에너지 측정을 위한 Time of Flight의 분해도 향상에 관한 이론적 연구)

  • Kim, J.H.;Yang, T.K.;Lee, C.Y.;Lee, B.C.
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.4
    • /
    • pp.311-316
    • /
    • 2008
  • Since the presence of the chemical impurities and defect at surfaces and interfaces greatly influence the properties of various semiconductor devices, an unambiguous chemical characterization of the metal and semiconductor surfaces become more important in the view of the miniaturization of the devices toward nano scale. Among the various conventional surface characterization tools, Electron-induced Auger Electron Spectroscopy (EAES), X-ray Photoelectron Spectroscopy (XPS) and Secondary Electron Ion Mass Spectroscopy (SIMS) are being used for the identification of the surface chemical impurities. Recently, a novel surface characterizaion technique, Positron-annihilation induced Auger Electron Spectroscopy (PAES) is introduced to provide a unique method for the analysis of the elemental composition of the top-most atomic layer. In PAES, monoenergetic positron of a few eV are implanted to the surface under study and these positrons become thermalized near the surface. A fraction of the thermalized positron trapped at the surface state annihilate with the neighboring core-level electrons, creating core-hole excitations, which initiate the Auger process with the emission of Auger electrons almost simultaneously with the emission of annihilating gamma-rays. The energy of electrons is generally determined by employing ExB energy selector, which shows a poor resolution of $6{\sim}10eV$. In this paper, time-of-flight system is employed to measure the electrons energy with an enhanced energy resolution. The experimental result is compared with simulation results in the case of both linear (with retarding tube) and reflected TOF systems.

MOCVD Growth and Characterization of Heteroepitaxial Beta-Ga2O3 (MOCVD 성장법을 이용한 Beta-Ga2O3 박막의 헤테로에피택시 성장 특성)

  • Jeong Soo Chung;An-Na Cha;Gieop Lee;Sea Cho;Young-Boo Moon;Myungshik Gim;Moo Sung Lee;Jun-Seok Ha
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.31 no.2
    • /
    • pp.85-91
    • /
    • 2024
  • In this study, we investigated a method of growing single crystal 𝛽-Ga2O3 thin films on a c-plane sapphire substrate using MOCVD. We confirmed the optimal growth conditions to increase the crystallinity of the 𝛽-Ga2O3 thin film and confirmed the effect of the ratio between O2 and Ga precursors on crystal growth on the crystallinity of the thin film. The growth temperature range was 600~1100℃, and crystallinity was analyzed when the O2/TMGa ratio was 800~6000. As a result, the highest crystallinity thin film was obtained when the molar ratio between precursors was 2400 at 1100℃. The surface of the thin film was observed with a FE-SEM and XRD ω-scan of the thin film, the FWHM was found to be 1.17° and 1.43° at the and (${\bar{2}}01$) and (${\bar{4}}02$) diffraction peaks. The optical band gap energy obtained was 4.78 ~ 4.88 eV, and the films showed a transmittance of over 80% in the near-ultraviolet and visible light regions.

An Optimization Method of Measuring Heart Position in Dynamic Myocardial Perfusion SPECT with a CZT-based camera (동적 심근관류 SPECT에서 심장의 위치 측정방법에 대한 고찰)

  • Seong, Ji Hye;Lee, Dong Hun;Kim, Eun Hye;Jung, Woo Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.75-79
    • /
    • 2019
  • Purpose Cadmium-zinc-telluride (CZT) camera with semiconductor detector is capable of dynamic myocardial perfusion SPECT for coronary flow reserve (CFR). Image acquisition with the heart positioned within 2 cm in the center of the quality field of view (QFOV) is recommended because the CZT detector based on focused multi-pinhole collimators and is stationary gantry without rotation. The aim of this study was to investigate the optimal method for measuring position of the heart within the center of the QFOV when performing dynamic myocardial perfusion SPECT with the Discovery NM 530c camera. Materials and Methods From June to September 2018, 45 patients were subject to dynamic myocardial perfusion SPECT with D530c. For accurate heart positioning, the patient's heart was scanned with a mobile ultrasound and marked at the top of the probe where the mitral valve (MV) was visible in the parasternal long-axis view (PLAX). And, the marked point on the patient's body matched with the reference point indicated CZT detector in dynamic stress. The heart was positioned to be in the center of the QFOV in rest. The coordinates of dynamic stress and rest were compared statistically. Results The coordinates of the dynamic stress using mobile ultrasound and those taken of the rest were recorded for comparative analysis with regard to the position of the couch and analyzed. There were no statistically significant differences in the coordinates of Table in & out, Table up & down, and Detector in & out (P > 0.05). The difference in distance between the 2 groups was measured at $0.25{\pm}1.00$, $0.24{\pm}0.96$ and $0.25{\pm}0.82cm$ respectively, with no difference greater than 2 cm in all categories. Conclusion The position of the heart taken using mobile ultrasound did not differ significantly from that of the center of the QFOV. Therefore, The use of mobile ultrasound in dynamic stress will help to select the correct position of the heart, which will be effective in clinical diagnosis by minimizing the image quality improvement and the patient's exposure to radiation.

Feasibility Study of Dose Evaluation of Stereotactic Radiosurgery using GafChromic $EBT^{(R)}$ Film (GafChromic $EBT^{(R)}$ 필름을 이용한 뇌정위방사선치료의 선량분석 가능성 평가)

  • Jang, Eun-Sung;Lee, Chul-Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.1
    • /
    • pp.27-33
    • /
    • 2007
  • Purpose: We have performed SRS (stereotactic radiosurgery) for avm (arterry vein malformation) and brain cancer. In order to verify dose and localization of SRS, dose distributions from TPS ($X-Knife^{(R)}$ 3.0, Radionics, USA) and GafChromic $EBT^{(R)}$ film in a head phantom were compared. Materials and Methods: In this study, head and neck region of conventional humanoid phantom was modified by substituting one of 2.5 cm slap with five 0.5 cm acrylic plates to stack the GafChromic $EBT^{(R)}$ film slice by slice with 5 mm intervals. Four films and five acrylic plates were cut along the contour of head phantom in axial plane. The head phantom was fixed with SRS head ring and adapted SRS localizer as same as real SRS procedure. CT images of the head phantom were acquired in 5 mm slice intervals as film interval. Five arc 6 MV photon beams using the SRS cone with 2 cm diameter were delivered 300 cGy to the target in the phantom. Ten small pieces of the film were exposed to 0, 50, 100, 200, 300, 400, 500, 600, 700, 800, 900 cGy, respectively to calibrate the GafChromic $EBT^{(R)}$ film. The films in the phantom were digitized after 24 hours and its linearity was calibrated. The pixel values of the film were converted to the dose and compared with the dose distribution from the TPS calculation. Results: Calibration curve for the GafChromic $EBT^{(R)}$ film was linear up to 900 cGy. The R2 value was better than 0.992. Discrepancy between calculated from $X-Knife^{(R)}$ 3.0 and measured dose distributions with the film was less than 5% through all slices. Conclusion: It was possible to evaluate every slice of humanoid phantom by stacking the GafChromic EBT film which is suitable for 2 dimensional dosimetry, It was found that film dosimetry using the GafChromic $EBT^{(R)}$ film is feasible for routine dosimetric QA of stereotactic radiosurgery.

  • PDF

Urinary tract infections in infants under six months of age (6개월 미만 영아의 요로 감염)

  • Kang, Min Joo;Shin, Hye Kyung;Yim, Hyung Eun;Je, Bo-Kyung;Eun, So Hee;Choi, Byung Min;Park, Jong-Tae;Eun, Baik Lin;Yoo, Kee Hwan
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.3
    • /
    • pp.278-286
    • /
    • 2006
  • Purpose : Although suprapubic bladder aspiration(SBA) is the most reliable technique for identifying bacteriuria in young infant, no report has been published about the clinical manifestations of urinary tract infection(UTI) diagnosed by aspirated urine in Korea. This study was performed to examine clinical manifestations and related factors of UTI confirmed by a positive urine culture obtained by SBA in young infants. Methods : We reviewed medical records of 159 infants younger than six months of age, who had been admitted for UTI to Korea University Ansan Hospital from January 2002 to June 2005. Results : The male:female ratio was 5.1 : 1. The most common pathogen in urine culture was Escherichia coli(92.5 percent). Most of the gram-negative pathogens had high sensitivity to amikacin, or third generation cephalosporins and had low sensitivity to ampicillin, trimethoprim-sulfamethoxazole, or gentamicin. Hydronephrosis and vesicoureteral reflux(VUR) were present in 32.7 percent and 27.7 percent respectively. Renal cortical defects observed on DMSA scans were detected in 37.1 percent. Prolonged fever duration and hospital day, high erythrocyte sedimentation rate(ESR) and C-reactive protein(CRP) levels, hydronephrosis and VUR were related to the renal cortical defects(P<0.05). Rates of UTI-associated bacteremia and aseptic meningitis were 8.3 percent and 6.6 percent. Conclusion : Early differential diagnosis is very important in infants younger than 6 months of age with UTI because the clinical findings are non-specific and UTI-associated bacteremia and aseptic meningitis are concomitantly found. Because prolonged fever and higher ESR and CRP levels are risk factors of the renal cortical defects, radiologic evaluations and nephrologic follow-up were needed in identifying the predisposing congenital abnormalities and chronic renal scarring.

Higher Order Shimming for Ultra-fast Spiral-Scan Imaging at 3 Tesla MRI System (3 Tesla MRI 시스템에서 초고속 나선주사영상을 위한 고차 shimming)

  • Kim, P.K.;Lim, J.W.;Ahn, C.B.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.11 no.2
    • /
    • pp.95-102
    • /
    • 2007
  • Purpose: To acquire high-resolution spiral-scan images at higher magnetic field, high homogeneous magnetic field is needed. Field inhomogeneity mapping and in-vivo shimming are important for rapid imaging such as spiral-scan imaging. The rapid scanning sequences are very susceptible to inhomogeneity. In this paper, we proposed a higher-order shimming method to obtain homogeneous magnetic field. Materials and Methods: To reduce measurement time for field inhomogeneity mapping, simultaneous axial/ sagittal, and coronal acquisitions are done using multi-slice based Fast Spin echo sequence. Acquired field inhomogeneity map is analyzed using the spherical harmonic functions, and shim currents are obtained by the multiplication of the pseudo-inverse of the field pattern with the inhomogeneity map. Results: Since the field inhomogeneity is increasing in proportion to the magnetic field, higher order shimming to reduce the inhomogeneity becomes more important in high field imaging. The shimming technique in which axial, sagittal, and coronal section inhomogeneity maps are obtained in one scan is developed, and the shimming method based on the analysis of spherical harmonics of the imhomogenity map is applied. The proposed technique is applicable to a localized shimming as well. High resolution spiral-scan imaging was successfully obtained with the proposed higher order shimming. Conclusion: Proposed pulse sequence for rapid measurement of inhomogeneity map and higher order shimming based on the inhomogeneity map work very well at 3 Tesla MRI system. With the proposed higher order shimming and localized higher order shimming techniques, high resolution spiral-scan images are successfully obtained at 3 T MRI system.

  • PDF

$^{99m}Tc-HMPAO$ Labelled WBC Scan in Experimental Abscess by Labelling Autologous Leukocytes With In-House-Synthesized HMPAO (국내 합성한 HMPAO 이용 $^{99m}Tc$ 표지 백혈구를 이용한 실험적 농양 스캔)

  • Lee, Dong-Soo;Shin, Hyung-Sik;Ahn, Cu-Rie;Chung, Jung-Key;Lee, Myung-Chul;Choi, Kang-Won;Koh, Chang-Soon;Jung, Jae-Min;Chung, Eun-Ju
    • The Korean Journal of Nuclear Medicine
    • /
    • v.25 no.2
    • /
    • pp.252-258
    • /
    • 1991
  • With HMPAO we have synthesized in our laboratory, we labelled $^{99m}Tc$ to canine leukocytes. Experimental abscess made by subcutaneous injection with Staphylococcus aureus was imaged with these $^{99m}Tc$ labelled leukocytes. Labelling efficiency of HMPAO with $^{99m}Tc$ was $66.2%{\pm}14.6%$ (N=9). Labelling efficiency of leukocytes with $^{99m}Tc-HMPAO$ was $54%{\pm}7.7%$ (N=7). Cell bound radioactivity in $^{99m}Tc-HMPAO$ labelled leukocytes was around 80% when these cells were incubated in plasma in vitro at $37^{\circ}C$ for 5 hours. In vivo cell bound activity was over 80% at 24 hours after injection. One day and four days after inoculation, uptake at the inflammatory focus was found with $^{99m}Tc$ labelled leukocytes. Uptake showed up in 4 hour image, and the uptake at the lesion was most prominent in 24 hour image. These findings show that in-house-synthesized HMPAO could be used for labelling leukocytes with $^{99m}Tc$, and that s$^{99m}Tc-HMPAO-labelled$ leukocytes were so stable and viable that inflammatory focus could be visualized with these $^{99m}Tc-labelled$ leukocytes.

  • PDF

The Usefulness of Three-phase Bone Scan and Thermography for Making the Diagnosis of CRPS-I (제1형 복합부위 통증증후군의 진단에서 적외선 체열측정과 3상 골스캔의 유용성)

  • Park, Sang Hyun;Lee, Pyung Bok;Lim, Yun Hee;Lee, Seung Yoon;Choi, In Yong;Lee, Sang Jin;Oh, Yong Seok
    • The Korean Journal of Pain
    • /
    • v.19 no.1
    • /
    • pp.81-86
    • /
    • 2006
  • Background: Complex regional pain syndrome (CRPS) is a painful and disabling disease, yet the diagnosis of this can be difficult to confirm by purely objective measures. Therefore, we performed three-phasic bone scans and thermography as a work up in order to determine their predictive value and usefulness for making the diagnosis of CRPS. Methods: 44 patients who had been diagnosed with CRPS type-1, according to the modified criteria, were evaluated. All the patients were examined by performing a three-phasic bone scan and thermography as part of a work-up for diagnostic confirmation. The diffuse increased tracer uptake in the delayed image (phase III) was estimated by the positive findings. The findings were considered positive for CRPS if the thermographic findings showed temperature asymmetries between the affected and non- affected extremities of more than $1.00^{\circ}C$ Results: A review of the three-phasic bone scan for 44 patients indicated that 16 patients (36.4%) had diffusely positive scans, and thermographic abnormalities were noted in 35 of 44 patients (79.5%). Conclusions: The use of thermography in clinical settings can play an important role in the diagnosis of CRPS. However, a three-phasic bone scan alone cannot provide a completely accurate diagnosis, so it is imperative that the three-phasic bone scan data be integrated with the clinical evaluation and the other relevant tests.