• Title/Summary/Keyword: Bypass Technique

Search Result 230, Processing Time 0.023 seconds

Comparison of Inflammatory Response and Myocardial injury Between Normoxic and Hyperoxic Condition during Cardiopulmonary Bypass (체외순환 시 정상 산소분압과 고 산소분압의 염증반응 및 심근손상에 관한 비교연구)

  • 김기봉;최석철;최국렬;정석목;최강주;김양원;김병훈;이양행;조광현
    • Journal of Chest Surgery
    • /
    • v.34 no.7
    • /
    • pp.524-533
    • /
    • 2001
  • Background: Hyperoxemic cardiopulmonary bypass (CPB) has been recognized as a safe technique and is widely used in cardiac surgery. However, hyperoxemic CPB may produce higher toxic oxygen species and cause more severe oxidative stress and ischemia/reperfusion injury than normoxemic CPB. This study was undertaken to compare inflammatory responses and myocardial injury between normoxemic and hyperoxemic CPB and to examine the beneficial effect of normoxemic CPB. Material and method: Thirty adult patients scheduled for elective cardiac surgery were randomly divided into normoxic group (n=15), who received normoxemic CPB (about Pa $O_{2}$ 120 mmHg), and hyperoxic group (n=15), who received hyperoxemic CPB (about Pa $O_{2}$ 400 mmHg). Myeloperoxidase (MPO), malondialdehyde (MDA), adenosine monophosphate (AMP), and troponin-T (TnT) concentrations in coronary sinus blood were determined at pre- and post-CPB. Total leukocyte and neutrophil counts in arterial blood were measured at the before, during, and after CPB. Lactate concentration in mixed venous blood was analyzed during CPB, and cardiac index (Cl) and pulmonary vascular

  • PDF

Total Arterial Revascularization Using Y-composite Graft for Isolated Left Main Coronary Artery Disease (단독 좌주간 관동맥 협착병변에서 Y-도관을 이용한 완전 동맥도관 관상동맥우회로 조성술)

  • Ahn, Byong-Hee;Yu, Ung;Chun, Joon-Kyung;Ryu, Sang-Wan;Choi, Yong-Sun;Kim, Byong-Pyo;Hong, Sung-Bum;Bum, Min-Sun;Na, Kook-Ju;Jung, Myung-Ho;Kim, Sang-Hyung
    • Journal of Chest Surgery
    • /
    • v.37 no.1
    • /
    • pp.35-42
    • /
    • 2004
  • Background: For the treatment of isolated left main coronary artery disease, twelve arterial revascularizations with Y-composite grafts using left internal thoracic artery and radial artery or right gastroepiploic artery were peformed. This study was performed to investigate whether V-composite graft can satisfy the blood flow required to make myocardium act properly or not. Borderline stenotic lesions on the left main coronary artery, which are very prone to remodel the bypassed vessels due to competitive flows, were also considered. Material and Method: Among 247 patients who underwent coronary artery bypass grafting from March 2000 to April 2003, 12 patients (4.7%) who had received total arterial revascularizations for the isolated left main coronary artery disease were studied retrospectively. Result: left anterior descending arteries were bypassed with left internal thoracic artery by off-pump technique in all patients, however, 2 cases of left obtuse marginal branches were bypassed under on-pump beating heart. Except for one patient, who did not have an obtuse marginal branch more than 1 mm in diameter, 11 patients had gone through complete arterial revascularizations by use of the Y shape arterial graft. Among five patients who had less than 75% stenosis, one patient showed string sign on left internal thoracic artery grafted to left anterior descending artery. However, two grafts to obtuse marginal blanches were completely obstructed and one showed slender sign. There were no graft-dominant flow in patients with stenotic lesion less than 75%. On the contrary to the result of patients with stenotic lesions less than 75%, all the patients with stenotic lesions more than 90% showed graft-dominant blood flow. Conclusion: In conclusion, it is assumed that, when stenotic lesions are over 90%, coronary artery bypass grafting with an Y shape arterial graft could possibly give enough help to the obstructed coronary arteries in blood supplying to myocardium, which needs massive quantity of blood to act well. However, when patients have borderline stenoses, through scrupulous examinations, more prudent and flexible decisions are required in choosing the treatment methods, such as, direct anastomosis of vein or artery to aorta, or adding supplementary treatment methods like percutaneous coronary intervention, rather than choosing a fixed treatment methods.

Use of Intermittent Antegrade Warm Blood Cardioplegia in CABG (관상동맥 우회로조성술에서 간헐적 전방 온혈 심정지액의 이용)

  • 김정택;백완기;김영삼;윤용한;김혜숙;이춘수;임현경;김현태;김광호
    • Journal of Chest Surgery
    • /
    • v.36 no.11
    • /
    • pp.828-833
    • /
    • 2003
  • Background: It has been reported that the recently developed intermittent antegrade warm blood cardioplegia (IAWBC) has better myocardial protective effects during coronary artery bypass surgery than cold blood cardioplegia or continuos retrograde cold blood cardioplegia. The aim of this study is to evaluate the safety and usefulness of IAWBC by comparing it retrospectively with intermittent retrograde cold blood cardioplegia (lRCBC). Material and Method: From April 2001 to Feb. 2003, fifty seven patients who underwent isolated coronary surgery were divided into two groups (IAWBC vs. IRCBC). The two group had similar demographic and angiographic characteristics. There were no statistical differences in age, sex, Canadian Cardiovascular Society Functional Classification for angina, ejection fraction, and number of grafts. Result: Aortic cross clamping time and total pump time in IAWBC (99$\pm$23 and vs. 126$\pm$32 min) were shorter than those of IRCBC (118$\pm$32 min. and 185$\pm$48 min.)(p<0.05). The reperfusion time (13$\pm$7 min) in IAWBC was shorter than that of IRCBC (62$\pm$109 min.)(p<0.05). CKMB at 12 hours and 24 hours (16$\pm$15 and 9$\pm$13) in IAWBC was lower than that of IRCBC (33$\pm$47 and 17$\pm$26)(p<0.05). The awakening time in IAWBC (2$\pm$1 hour) was shorter than that of IRCBC (4$\pm$3)(p<0.05). The number of spontaneous heart beat recovery in IAWBC (85%) was more than that of IRCBC (35%)(p<0.05). The cardiac index after discontinuing cardio-pulmonary bypass was significantly elevated in the IAWBC group. The prevalence of perioperative myocardial infarction in IAWBC (4%) was lower than that of IRCBC group (20%)(p<0.05). Conclusion: Intermittent antegrade warm blood cardioplegia is a safe, reliable, and effective technique for myocardial protection. It can also provide simpler and economic way than the retrograde cold cardioplegia by shortening of cardiopulmonary bypass time and avoiding retrograde cannulation for coronary sinus.

Steroid Effect on the Brain Protection During OPen Heart Surgery Using Hypothermic Circulatory Arrest in the Rabbit Cardiopulmonary bypass Model (저체온순환정지법을 이용한 개심술시 스테로이드의 뇌보호 효과 - 토끼를 이용한 심폐바이패스 실험모델에서 -)

  • Kim, Won-Gon;Lim, Cheong;Moon, Hyun-Jong;Chun, Eui-Kyung;Chi, Je-Geun;Won, Tae-Hee;Lee, Young-Tak;Chee, Hyun-Keun;Kim, Jun-Woo
    • Journal of Chest Surgery
    • /
    • v.30 no.5
    • /
    • pp.471-478
    • /
    • 1997
  • Introduction: The use of rabbits as a cardiopulmonary bypass(CPB) animal model is extremely dif%cult mainly due to technical problems. On the other hand, deep hypothermic circulatory arrest(CA) is used to facilitate surgical repair in a variety of cardiac diseases. Although steroids are generally known to be effective in the treatment of cerebral edema, the protective effects of steroids on the brain during CA are not conclusively established. Objectives of this study are twofold: the establishment of CPB technique in rabbits and the evaluation of preventive effect of steroid on the development of brain edema during CA. Material '||'&'||' Methods: Fifteen New Zealan white rabbits(average body weight 3.5kg) were divided into three experimental groups; control CA group(n=5), CA with Trendelenberg position group(n=5), and CA with Trendelenberg position + steroid(methylprednisolone 30 mglkg) administration group(n=5). After anesthetic induction and tracheostomy, a median sternotomy was performed. An aortic cannula(3.3mm) and a venous ncannula(14 Fr) were inserted, respectively in the ascending aorta and the right atrium. The CPB circuit consisted of a roller pump and a bubble oxygenator. Priming volume of the circuit was approximately 450m1 with 120" 150ml of blood. CPB was initiated at a flow rate of 80~85ml/kg/min, Ten min after the start of CPB, CA was established with duration of 40min at $20^{\circ}C$ of rectal temperature. After CA, CPB was restarted with 20min period of rewarming. Ten min after weaning, the animal was sacrif;cod. One-to-2g portions of the following tissues were rapidly d:ssected and water contents were examined and compared among gr ups: brain, cervical spinal cord, kidney, duodenum, lung, heart, liver, spleen, pancreas. stomach. Statistical significances were analyzed by Kruskal-Wallis nonparametric test. Results: CPB with CA was successfully performed in all cases. Flow rate of 60-100 mlfkgfmin was able to be maintained throughout CPB. During CPB, no significant metabolic acidosis was detected and aortic pressure ranged between 35-55 mmHg. After weaning from CPB, all hearts resumed normal beating spontaneously. There were no statistically significant differences in the water contents of tissues including brain among the three experimental groups. Conclusion: These results indicate (1) CPB can be reliably administered in rabbits if proper technique is used, (2) the effect of steroid on the protection of brain edema related to Trendelenburg position during CA is not established within the scope of this experiment.

  • PDF

Perfusion Techniques Using the Modified Isolated Working Rat Heart Model (흰쥐의 심장을 이용한 Modified Isolated Working Heart Perfusion Technique)

  • Lee, Chong-Kook;Choi, Hyeong-Ho
    • Journal of Chest Surgery
    • /
    • v.13 no.4
    • /
    • pp.338-345
    • /
    • 1980
  • We have modified an isolated perfusion rat heart model of cardiopulmonary bypass, with which we are able to screen the effects of various cardioplegic solutions and hypothermia upon the ability of the heart to survivie during and recover from period of ischemic arrest. The modified experimental model was differed from the original as follow : a heat coil chamber of atrial and aortic reservoir provided temperature control, and the perfusate was gassed with each pure oxygen and pure carbon dioxide in 95:5 ratio. The Langendorff perfusion was initiated for a 10 minute period by introducing perfusate at $37^{\circ}C.$ into the aorta from the aortic reservoir located 100 cm above the heart. The isolated perfused working rat heart model was a left heart preparation in which oxygenated perfusion medium (at $37^{\circ}C.$) entered the cannulated left atrium at a pressure of 20 cm $H_{2}O$ and was passed to the ventricle, from which it was sponeously elected(no electrical pacing) via an aortic cannula, against a hydrostatic pressure of 100cm $H_{2}O$. during this working period various indices of cardiac functin were measured. The cardiac functions were stable for over 3 hour with perfusion of Krebs-Henseleit bicarbonate buffer solution containing only glucose (11.1 mM/L). The percentage of cardiac functins were maintained about 94% on heart rate, 80.6% on peak aortic pressure, 87.7% on coronary flow and 76.3% on aortic flow rate after 3 hour of working heart perfusion at a pressure of 20 cm $H_{2}O$. We believe this preparation to be a good biochemical model for the human heart which offers many advantages including economic, speed of preparation, reproducibility, and the ability to handle large numbers.

  • PDF

A Smart Ticketing System Based-on Hybrid Web (하이브리드 웹 기반의 스마트 발권 시스템)

  • Park, Byung-Eon;Park, Jin-Sub;Jung, Il-Hong
    • Journal of Digital Contents Society
    • /
    • v.12 no.4
    • /
    • pp.567-574
    • /
    • 2011
  • In this paper, we have designed and implemented a commercial web system for the future which resolves the necessary security and compatibility to the existing issues in various fields such as theater or the ball park that tickets are issued. The system presents the OTP (One Time Password) system using the mobile in order for defense in the bypass hacking technique such as screen hacking and for greater security. Also, we presents a smart ticketing system that improve the existing responsive hybrid web. It uses Non-ActiveX System which solve compatible problems with present systems that don't use ActiveX. Also, it is available in a variety of environments and equipment. In addition, the system provides an intelligent screen switching systems using the characteristics of mobile devices, an automatic discount system, and a venue information system which shows the shortest distance to the venue considering the commercial portion.

The $Outback^{(R)}$ $LTD^{TM}$ Catheter: The Novel Re-Entry Technique in Recanalization of Chronic Inflow Occlusion of the Superficial Femoral Arteries in 3 Cases ($Outback^{(R)}$ $LTD^{TM}$ Catheter를 이용한 표재성 대퇴동맥의 만성동맥폐색증의 성공적인 재개통술: 3예 보고)

  • Kong, Joon-Hyuk;Hur, Jin;Kim, Duk-Sil;Kim, Sung-Wan
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.785-789
    • /
    • 2010
  • The acute technical failure of endovascular treatment of chronic total occlusions is most often due to the inability to re-enter the true lumen after occlusion is crossed in a subintimal plane. True lumen re-entry catheters are very effective at gaining wire passage back to the true lumen and facilitating successful endovascular treatment of chronic total occlusions that would otherwise require open bypass. These case reports describe our initial experiences with a new catheter system (the $Outback^{(R)}$ $LTD^{TM}$ catheter) that is designed to allow fluoroscopically controlled re-entry of the true arterial lumen after subintimal guidewire passage during recanalization procedures of arterial occlusions.

Reconstructive Procedures Combined with or Without Prosthetic Valve Replacement for Cardiac Valvular Lesions (심장판막 질환 성형술에 대한 임상적 고찰)

  • Kim, Y.;Cho, B.K.;Hong, S.N.
    • Journal of Chest Surgery
    • /
    • v.9 no.2
    • /
    • pp.207-214
    • /
    • 1976
  • Operations for cardiac valvular disease has been progressed in various ways. Since 1949 when Lord Russel operated mitral stenosis by closed technique at Johns Hopkins Hospital then much progress has been achieved and that nowadays severely diseased cardiac valve has been replaced by prosthetic valve, which is almost ideal in hemodynamic aspect, but still it has many problems such as thromboembolism, destruction of red blood cell, pressure gradient, and disturbance of left ventricular function, so in case of delicate situations, valve replacement should be decided carefully. Besides prosthetic valve, there are some kinds of reconstructive procedures and these have been resulted in better prognosis than prosthetic valve replacement in selected cases. So, authors have reviewed 61 Cases of cardiac patients who have been operated reconstructive valvular surgery by cardiopulmonary bypass, at Yonsei University, from Jan. 1963 to Mar. 1976. Out of 61 cases, 9 patients were replaced by prosthetic valve and rest of the patients were operated upon in various reconstructive procedures such as commissurotomy, valvotomy, valvuloplasty, and annuloplasty. Twenty cases of congenital heart diseases with valvular lesion, which had been operated for valvular lesion were also included in this statistics. Out of 9 cases of prosthetic valvular replacement five cases of prosthetic valvular replacement was done combined with other reconstructive procedures after attempted valvuloplasty. Comparative prognosis of both procedures are somewhat variable by reporters, average 19% of mortality after reconstructive surgery and 38% of mortality after prosthetic valve replacement in long term results. Most common cause of death in postoperative period was low output syndrome in both cases. It seems that good preoperative evaluation and proper reconstructive surgery will afford good prognosis in selected cardiac valvular diseased patient.

  • PDF

Numerical Studies of Flow Across End-to-Side Distal Vascular Bypass Graft Anastomoses

  • Kim, Y.H.;Kim, J.H.;Shin, J.W.
    • Journal of Biomedical Engineering Research
    • /
    • v.13 no.4
    • /
    • pp.339-352
    • /
    • 1992
  • A numerical simulation of the steady and pulsatile flow across the end-to-side anastomosis was performed In order to understand the role of flow dynamics in the preferential bevel opment of distal anastomotic intimal hyperplasla. The finite element technique was employed to solve two-dimensional unsteady pulsatile flow in that region. The results of the steady flow revealed that low shear stresses occur at the proximally occluded host artery and at the recirculation region in the Inner wall just distal to the toe region of the anastomosis. The nor- mal;zed wall shear rate was increased, as was the recirculation zone size in the host artery of the by-pass graft anastomosis, with increased anastomotic junction angle. In order to min imize the size of the low wall shear region which might result in the intimal hyperplasia in the by-pass graft anastomosis, a smaller anastomotic junction angle is recommended. The pulsatile flow simulation revealed flow that regions of low and ascillating mali shear do exist near the anastomosis as In the steady simulation. The shift of stagnation point depends on the pulsation of the flow. As the flow was accelerated at systole, the stagnation point moved downstream, disappered at early diastole and reappeared during late diastole. Low shear stress was also found along both walls of the occluded proximal artery. However, the diastolic flow behavior is quite different from the steady results. The vortex near the occluded artery moved downstream and inwardly during late systole, and disappeared during diastole. Recirculations proximal to the toe and heel regions were significant during diastole. Shear stress oscillation was found along the opposite wall. The results of the present study revealed that tow shear occurs at the proximally occluded host artery aud the recirculation region in the inner wall Just dlstal to the toe region of the anastomosis. The present study suggested that the regions of fluctuated wall shear stress wit flow separation is correlated with the preferential developing regions of anastomosis neointial fibrous hyperplasia.

  • PDF

Slotted Transmissions using Frame aggregation: A MAC protocol for Capacity Enhancement in Ad-hoc Wireless LANs (프레임 집합화를 이용한 애드-혹 무선 랜의 성능 향상을 위한 MAC 프로토콜)

  • Rahman, Md. Mustafizur;Hong, Choong-Seon
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.8
    • /
    • pp.33-41
    • /
    • 2007
  • The IEEE 802.11 DCF channel access function allows single transmission inside two-hop network in order to avoid collisions and eliminate the hidden and exposed terminal problems. Singular transmission capability causes data frames waiting for the entire roundtrip time in the transmitter neighborhood, and results in increased frame latency and lower network throughput. Real-time and pervasive applications are severely affected for the lower medium utilization; especially with high network traffic. This work proposes a new scheme with the help of Frame Aggregation technique in IEEE802.11n and overcomes the single transmission barrier maintaining the basic DCF functionality. Proposed scheme allows parallel transmissions in non-interfering synchronized slots. Parallel transmissions bypass the conventional physical carrier sense and random Backoff time for several cases and reduce the frame latency and increase the medium utilization and network capacity.