• Title/Summary/Keyword: Bypass Line

Search Result 69, Processing Time 0.027 seconds

Retrograde Autologous Priming: Is It Really Effective in Reducing Red Blood Cell Transfusions during Extracorporeal Circulation? (역행성 자가혈액 충전법: 체외순환 중 동종적혈구 수혈량을 줄일 수 있는가?)

  • Lim, Cheong;Son, Kuk-Hui;Park, Kay-Hyun;Jheon, Sang-Hoon;Sung, Sook-Whan
    • Journal of Chest Surgery
    • /
    • v.42 no.4
    • /
    • pp.473-479
    • /
    • 2009
  • Background: Retrograde autologous priming (RAP) is known to be useful in decreasing the need of transfusions in cardiac surgery because it prevents excessive hemodilution due to the crystalloid priming of cardiopulmonary bypass circuit. However, there are also negative side effects in terms of blood conservation. We analyzed the intraoperative blood-conserving effect of RAP and also investigated the efficacy of autotransfusion and ultrafiltration as a supplemental method for RAP. Material and Method: From January 2005 to December 2007, 117 patients who underwent isolated coronary artery bypass operations using cardiopulmonary bypass (CPB) were enrolled. Mean age was 63.9$\pm$9.1 years (range 36$\sim$83 years) and 34 patients were female. There were 62 patients in the RAP group and 55 patients in he control group. Intraoperative autotransfusion was performed via the arterial line. RAP was done just before initiating CPB using retrograde drainage of the crystalloid priming solution. Both conventional (CUF) and modified (MUF) ultrafiltrations were done during and after CPB, respectively. The transfusion threshold was less than 20% in hematocrit. Result: Autotransfusions were done in 79 patients (67.5%) and the average amount was 142.5$\pm$65.4 mL (range 30$\sim$320 mL). Homologous red blood cell (RBC) transfusion was done in 47 patients (40.2%) and mean amount of transfused RBC was 404.3$\pm$222.6 mL. Risk factors for transfusions were body surface area (OR 0.01, 95% CI 0.00 $\sim$ 0.63, p=0.030) and cardiopulmonary bypass time (OR 1.04, 95% CI 1.01 $\sim$ 1.08, p=0.019). RAP was not effective in terms of the rate of transfusion (34.5% vs 45.2%, p=0.24). However, the amount of transfused RBC was significantly decreased (526.3$\pm$242.3ml vs 321.4$\pm$166.3 mL, p=0.001). Autotransfusion and ultrafiltration revealed additive and cumulative effects decreasing transfusion amount (one; 600.0$\pm$231.0 mL, two; 533.3$\pm$264.6 mL, three; 346.7$\pm$176.7 mL, four; 300.0$\pm$146.1 mL, p=0.002). Conclusion: Even though RAP did not appear to be effective in terms of the number of patients receiving intraoperative RBC transfusions, it could conserve blood in terms of the amount transfused and with the additive effects of autotransfusion and ultrafiltration. If we want to maximize the blood conserving effect of RAP, more aggressive control will be necessary - such as high threshold of transfusion trigger or strict regulation of crystalloid infusion, and so forth.

Development of the HPM System to Improve Efficiency of the Hydraulic Excavator (유압식 굴삭기 효율 향상을 위한 HPM 시스템 개발)

  • Kwon, Yong Cheol;Lee, Kyung Sub;Kim, Sung Hun;Koo, Byoung Kook
    • Journal of Drive and Control
    • /
    • v.16 no.4
    • /
    • pp.1-8
    • /
    • 2019
  • The HPM (High-speed Power Matching) system is an electro-hydraulic control system. It directly controls the swash plate of the pump by selecting four-loop logic based on joystick signals, pump flow, and pressure signal to improve the efficiency and controllability of construction machines. In the NFC (Negative Flow Control) system, a typical pump control system using conventional open center type MCV, the loss is continuously generated by flow through the center bypass line even when the excavator is not in operation. Also, due to the slow response of the pump that indirectly controls the flow rate using the pressure regulator, peak pressure occurs at the start or stop of the operation. Conversely, the HPM system uses an MCV without center-by-pass flow path and the swash plate of a pump for the HPM is controlled by a high-speed proportional flow control valve. As a result, the HPM system minimizes energy loss in standby state of the excavator and enables peak pressure control through rapid electro-hydraulic control of a pump. In this paper, the concept of the HPM system algorithm is introduced and the hydraulic system efficiency is compared with the NFC system using the excavator SAT (System Analysis Tool).

Successful Correction of Atypical Coarctation of the Aorta -Report of 4 Cases- (선천성 대동맥 축착증 4례)

  • 권중혁
    • Journal of Chest Surgery
    • /
    • v.12 no.3
    • /
    • pp.174-182
    • /
    • 1979
  • This is a report on four cases of successful surgical correction of coarctation of the aorta [COA] in Department of the Thoracic & Cardiovascular Surgery, Hanyang University Hospital. The first case was a postductal type of coarctation of the aorta associated with Patent ductus arteriosus [PDA], Persistent left superior vena cava [LSVC] and richly developed collateral circulation. Blood pressure was measured to be hypertensive at the arm, but hypotensive at the legs. The coarctation of the aorta was corrected with following procedure: Partial resection of the aortic wall with diaphragmatic structure lust above and below the coarctating line of the aorta, and then the defect of the aortic wall was closed by lateral aortographic suture. PDA was closed by ligation procedure. The second case a preductal type of coarctation of the aorta associated with PDA, LSVC, ventricular septal defect [VSD] and poorly developed collateral circulation. Normal blood pressure was measured at the arm, but hypotension was observed at the legs. Correction of coarctation of the aorta was performed under the establishment of tube bypass because of poor collateral circulation. After resection of coarctating short segment, end to end anastomosis was performed without any tension. PDA was closed by division procedure. Simple suture closure of VSD was performed by open heart surgery two weeks after correction of COA. The third case was a long segment COA without any other anomaly. Blood pressure was measured to be hypertensive at the arm, but hypotensive at the legs. Vascular prosthesis was performed using Teflon graft tube after resecting coarctating long segment [6.5 cm] of the aorta. The fourth case was a long segment COA associated with aortic insufficiency and richly developed collateral circulation. Normal blood pressure was measured at the arm, but hypotension was observed at the legs. Vascular prosthesis was performed using Teflon graft tube after resecting coarctating long segment [6.0 cm] of the aorta. Both blood pressure and peripheral pulse on the arm and the legs returned to normal postoperatively in all patients.

  • PDF

Needle Entry Angle to Prevent Carotid Sheath Injury for Fluoroscopy-Guided Cervical Transforaminal Epidural Steroid Injection

  • Choi, Jaewoo;Ha, Doo Hoe;Kwon, Shinyoung;Jung, Youngsu;Yu, Junghoon;Kim, MinYoung;Min, Kyunghoon
    • Annals of Rehabilitation Medicine
    • /
    • v.42 no.6
    • /
    • pp.814-821
    • /
    • 2018
  • Objective To suggest rotation angles of fluoroscopy that can bypass the carotid sheath according to vertebral levels for cervical transforaminal epidural steroid injection (TFESI). Methods Patients who underwent cervical spine magnetic resonance imaging (MRI) from January 2009 to October 2017 were analyzed. In axial sections of cervical spine MRI, three angles to the vertical line (${\alpha}$, angle not to insult carotid sheath; ${\beta}$, angle for the conventional TFESI; ${\gamma}$, angle not to penetrate carotid artery) were measured. Results Alpha (${\alpha}$) angles tended to increase for upper cervical levels ($53.3^{\circ}$ in C6-7, $65.2^{\circ}$ in C5-6, $75.3^{\circ}$ in C4-5, $82.3^{\circ}$ in C3-4). Beta (${\beta}$) angles for conventional TFESI showed a constant value of $45^{\circ}$ to $47^{\circ}$ ($47.5^{\circ}$ in C6-7, $47.4^{\circ}$ in C5-6, $45.7^{\circ}$ in C4-5, $45.0^{\circ}$ in C3-4). Gamma (${\gamma}$) angles increased at higher cervical levels as did ${\alpha}$ angles ($25.2^{\circ}$ in C6-7, $33.6^{\circ}$ in C5-6, $43.0^{\circ}$ in C4-5, $56.2^{\circ}$ in C3-4). Conclusion The risk of causing injury by penetrating major vessels in the carotid sheath tends to increase at upper cervical levels. Therefore, prior to cervical TFESI, measuring the angle is necessary to avoid carotid vessels in the axial section of CT or MRI, thus contributing to a safer procedure.

High Power W-band Power Amplifier using GaN/Si-based 60nm process (GaN/Si 기반 60nm 공정을 이용한 고출력 W대역 전력증폭기)

  • Hwang, Ji-Hye;Kim, Ki-Jin;Kim, Wan-Sik;Han, Jae-Sub;Kim, Min-Gi;Kang, Bong-Mo;Kim, Ki-chul;Choi, Jeung-Won;Park, Ju-man
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.4
    • /
    • pp.67-72
    • /
    • 2022
  • This study presents the design of power amplifier (PA) in 60 nm GaN/Si HEMT technology. A customized transistor model enables the designing circuits operating at W-band. The all matching network of the PA was composed of equivalent transformer circuit to reduce matching loss. And then, equivalent transformer is several advantages without any additional inductive devices so that a wideband power characteristic can be achieved. The designed die area is 3900 ㎛ × 2300 ㎛. The designed results at center frequency achieved the small signal gain of 15.9 dB, the saturated output power (Psat) of 29.9 dBm, and the power added efficiency (PAE) of 24.2% at the supply voltage of 12 V.

Consolidation of Metro Networks and Access Networks by using Long-reach WDM-PON (장거리 전송 파장분할 다중방식 수동형 광가입자망을 이용한 메트로망과 가입자망 통합 방안)

  • Lee Sang-Mook;Mun Sil-Gu;Kim Min-Hwan;Lee Chang-Hee
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.5 s.347
    • /
    • pp.59-67
    • /
    • 2006
  • We demonstrate bidirectional long-reach 35-channel dense wavelength division multiplexing-passive optical network(DWDM-PON) based on wavelength-locked Fabry-Perot laser diodes (F-P LDs). The mode control of F-P LD enhances output power at decreased the required injection power. We show packet-loss-free transmission in all 70 channels at 125 Mb/s per channel line rate through 70 km of single mode fiber without optical amplifier The DWDM-PON can consolidate a metro network into an access network by bypassing the central offices within its reach. The proposed DWDM-PON can accommodate about 80 subscribers with an EDFA-based broadband light source. Further expansion up to 100 subscribers is possible with a semiconductor-based BLS.

A Multiphase DLL Based on a Mixed VCO/VCDL for Input Phase Noise Suppression and Duty-Cycle Correction of Multiple Frequencies (입력 위상 잡음 억제 및 체배 주파수의 듀티 사이클 보정을 위한 VCO/VCDL 혼용 기반의 다중위상 동기회로)

  • Ha, Jong-Chan;Wee, Jae-Kyung;Lee, Pil-Soo;Jung, Won-Young;Song, In-Chae
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.11
    • /
    • pp.13-22
    • /
    • 2010
  • This paper proposed the dual-loops multiphase DLL based mixed VCO/VCDL for a high frequency phase noise suppression of the input clock and the multiple frequencies generation with a precise duty cycle. In the proposed architecture, the dual-loops DLL uses the dual input differential buffer based nMOS source-coupled pairs at the input stage of the mixed VCO/VCDL. This can easily convert the input and output phase transfer of the conventional DLL with bypass pass filter characteristic to the input and output phase transfer of PLL with low pass filter characteristic for the high frequency input phase noise suppression. Also, the proposed DLL can correct the duty-cycle error of multiple frequencies by using only the duty-cycle correction circuits and the phase tracking loop without additional correction controlled loop. At the simulation result with $0.18{\mu}m$ CMOS technology, the output phase noise of the proposed DLL is improved under -13dB for 1GHz input clock with 800MHz input phase noise. Also, at 1GHz operating frequency with 40%~60% duty-cycle error, the duty-cycle error of the multiple frequencies is corrected under $50{\pm}1%$ at 2GHz the input clock.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2009 (설비공학 분야의 최근 연구 동향 : 2009년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwa-Taik;Lee, Dae-Young;Kim, Seo Young;Choi, Jong-Min;Baik, Yong-Kyu;Kwon, Young-Chul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.7
    • /
    • pp.492-507
    • /
    • 2010
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2009. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends of thermal and fluid engineering have been surveyed as groups of general thermal and fluid flow, fluid machinery and piping, and new and renewable energy. Various topics were covered in the field of general thermal and fluid flow such as an expander, a capillary tube, the flow of micro-channel water blocks, the friction and anti-wear characteristics of nano oils with mixtures of refrigerant oils, etc. Research issues mainly focused on the design of micro-pumps and fans, the heat resistance reliability of axial smoke exhaust fans, and hood systems in the field of fluid machinery and piping. Studies on ground water sources were executed concerning two well type geothermal heat pumps and multi-heat pumps in the field of new and renewable energy. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included the heat transfer in thermoelectric cooling systems, refrigerants, evaporators, dryers, desiccant rotors. In the area of industrial heat exchangers, researches on high temperature ceramic heat exchangers, plate heat exchangers, frosting on fins of heat exchangers were performed. (3) In the field of refrigeration, papers were presented on alternative refrigerants, system improvements, and the utilization of various energy sources. Refrigeration systems with alternative refrigerants such as hydrocarbons, mixed refrigerants, and $CO_2$ were studied. Efforts to improve the performance of refrigeration systems were made applying various ideas of suction line heat exchangers, subcooling bypass lines and gas injection systems. Studies on heat pump systems using unutilized energy sources such as river water, underground water, and waste heat were also reported. (4) Research trend in the field of mechanical building facilities has been found to be mainly focused on field applications rather than performance improvements. In the area of cogeneration systems, papers on energy and economic analysis, LCC analysis and cost estimating were reported. Studies on ventilation and heat recovery systems introduced the effect on fire and smoke control, and energy reduction. Papers on district cooling and heating systems dealt with design capacity evaluation, application plan and field application. Also, the maintenance and management of building service equipments were presented for HVAC systems. (5) In the field of architectural environment, various studies were carried to improve indoor air quality and to analyze the heat load characteristics of buildings by energy simulation. These studies helped to understand the physics related to building load characteristics and to improve the quality of architectural environment where human beings reside in.

A Comparative Study on the Effect of Enterprise SNS on Job Performance - Focused on the Mediation Effect of Communication Level and Moderating Effect of Nationality - (기업용 SNS 이용이 업무성과에 미치는 영향의 국가 간 비교연구 - 커뮤니케이션 수준의 매개효과와 국적의 조절효과를 중심으로 -)

  • Chen, Jing-Yuan;Kwon, Sun-Dong
    • Management & Information Systems Review
    • /
    • v.38 no.4
    • /
    • pp.137-157
    • /
    • 2019
  • Companies are trying to use enterprise SNS for collaboration and speedy decision-making. This study verified the mediating effect of communication between enterprise SNS and job performance, and proved the moderating effect of nationality between enterprise SNS and communication. This study collected survey data of 81 Korean and 81 Chinese from employees who have used enterprise SNS in Korea and China. As results of data analysis, first, enterprise SNS improved job performance through speedy information sharing and error reduction. Second, communication mediated the effect of enterprise SNS on job performance. Third, enterprise SNS increased the level of organizational communication through decreasing the burden of offline face-to-face communication. Compared with Chinese corporate organizations, Korean corporate organizations have high power distances, centralized control, and high superior authority. Therefore, in the off-line communication situation, the subordinate feels the social pressure to follow the command of the superior. Thus communication is one-way and closed. In this Korean organizational situation, corporate SNS can be used as a means to bypass rigid offline communication. In the online communication environment of non face-to-face corporate SNS, anxiety and stress of face-to-face communication can be reduced, so communication between the upper and lower sides can flow more smoothly. The contribution of this paper is that it proved that enterprise SNS promotes communication and improve job performance by reducing the anxiety or stress of offline communication, while according to prior research successful adoption of many types of information systems requires the fit between an organization and its organizational culture.