• Title/Summary/Keyword: Bus Company

Search Result 71, Processing Time 0.027 seconds

An Analysis of the Correlation between Health-related Habits and the Biochemical Characteristics of the Blood of Bus Drivers in the Masan Area (마산지역 시내버스 운전자의 건강관련 생활습관과 혈액의 생화학적 지표와의 상호관련성 분석)

  • 윤현숙;김기련
    • Korean Journal of Community Nutrition
    • /
    • v.7 no.2
    • /
    • pp.232-244
    • /
    • 2002
  • This study investigated the correlation between health-related habits and the biochemical characteristics of the blood of Korean bus drivers. A total of 178 bus drivers working in the Masan area participated in this study. The general characteristics and health-related habits of the subjects were surveyed using a serf-administered questionnaire. The biochemical date were collected from regular health check-ups done through their workshop health insurance company in lune, 1999. The results were as follows : The average age of the subjects was 38 years, and 44.2% had a driving career of between 10 and 19 years. About 90% of the subjects ate irregularly, and 36% ate. health floods. Their rates of drinking, smoking and exercise were 74.6%, 83.6% and 70.8%, respectively. Their frequency of drinking was significantly increased as the length of their driving career increased (p < 0.001). Their levels of total serum cholesterol, in relation to the length of their driving career was significantly higher in the over 20 year group than in the below 10 year group (p < 0.05). Their systolic blood pressures, according to age, were significantly higher in the 51 to 60 age group than in the other groups (p < 0.05). Their total um cholesterol levels signiscantly increased with increasing age (p < 0.001). Their diastolic blood pressures (p < 0.001) and blood glucose levels (p < 0.05) were significantly higher among the subjects who drinking alcohol almost everyday, than among other subjects. Their systolic blood pressures who significantly increased with increasing frequency of their drinking (p < 0.001). The systolic blood pressure and diastolic blood pressure were positively related to age, the amount of drinking, the frequency of drinking and the obesity index, and negatively related to exercise and the duration of exercise. The hemoglobin was positively related to age, preference for a meat diet and the obesity index. The blood glucose was positively related to the amount of drinking, and the total serum cholesterol was positively related to age, length of driving career, period of smoking and the obesity index. The results of this study indicated that bus drivers need regular exercise, moderation of their drinking and smoking, and control of their body weights so as to prevent chronic diseases.

Design and Analysis of Large Induction Motor Control Coping with Voltage Sag (순간전압강하 극복을 위한 대용량 유도전동기 제어방식 설계 및 해석)

  • Cho, Sung-Don;Lim, Seong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1056-1058
    • /
    • 1998
  • Voltage dips caused by transmission system faults are usually of a short duration. High speed relaying and breaker operation will typically limit the disturbance to 0.1 seconds. Most motor controllers obtain their control power directly from the bus by means of a control transformer. Under this condition, a voltage dip can cause the contactor to drop out. disconnecting the motor from the line. The rapid re-energizing of the controller is in effect a fast reclosure which may result in motor damage. The time delay re-energizing of controller will result in a greater loss of speed and possibly loss of stability. Other means of controller can be used to prevent the motor from being disconnected from line during the fault. This can be accomplished by DC power controller or mechanically latched controller. This paper demonstrates that DC power controller or mechanically latched type controller to prevent the motor from being disconnected from line during the fault is, the most effective in minimizing speed reduction, transient motor current, transient motor torque and transient shaft torque by EMTP calculation.

  • PDF

An Analysis of the Determinants of Government-Funded Defense Companies using a Decision Tree (의사결정나무를 활용한 방산육성지원 수혜기업 결정요인 분석)

  • Gowoon Jeon;Seulah Baek;Jeonghwan Jeon;Donghee Yoo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.27 no.1
    • /
    • pp.80-93
    • /
    • 2024
  • This study attempted to analyze the factors that influence the participation of beneficiary companies in the government's defense industry promotion support project. To this end, experimental data were analyzed by constructing a prediction model consisting of highly important variables in beneficiary company decisions among various company information using the decision tree model, one of the data mining techniques. In addition, various rules were derived to determine the beneficiary companies of the government's support project using the analysis results expressed as decision trees. Three policy measures were presented based on the important rules that repeatedly appear in different predictive models to increase the effect of the government's industrial development. Using the analysis methods presented in this study and the determinants of the beneficiary companies of the government support project will help create a sustainable future defense industry growth environment.

X Band 7.5 W MMIC Power Amplifier for Radar Application

  • Lee, Kyung-Ai;Chun, Jong-Hoon;Hong, Song-Cheol
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.8 no.2
    • /
    • pp.139-142
    • /
    • 2008
  • An X-band MMIC power amplifier for radar application is developed using $0.25-{\mu}m$ gate length GaAs pHEMT technology. A bus-bar power combiner at output stage is used to minimize the combiner size and to simplify bias network. The fabricated power amplifier shows 38.75 dBm (7.5 Watt) Psat at 10 GHz. The chip size is $3.5\;mm{\times}3.9\;mm$.

Design of the Material Control System based on Service Oriented Architecture (서비스 지향 아키텍쳐 기반의 자재관리시스템 설계)

  • An, Min-Jeong;Lee, Hong-Chul
    • IE interfaces
    • /
    • v.20 no.3
    • /
    • pp.257-266
    • /
    • 2007
  • To survive in rapidly changing business environment, the enterprises of all over the world are trying to integrate their IT infra structure and are trying to automate their business process. Service Oriented Architecture (SOA) is being accepted as an IT standard to support efficient system integration and flexible business process automation between enterprises or departments. The material control system is required this software architecture between manufacturing company and materials supply vendors. This paper introduces concept of SOA, relevant technology about SOA such as Web Services and Business Process Execution Language (BPEL) and Enterprise Service Bus (ESB) and describes how to automate materials control process by designing the material control system based on SOA. The analysis of requirements is proceeded by Unified Modeling Language (UML) and SOA delivery strategy is selected the top-down strategy. And this paper describes how to derive services and operations and how to arrange services in three service layers and how to design business process.

A Method to Control Unstable Hopf Bifurcation in Power Systems

  • Lee, Sang-Ho;Park, Jong-Keun
    • KIEE International Transactions on Power Engineering
    • /
    • v.4A no.1
    • /
    • pp.1-5
    • /
    • 2004
  • The model of a power system with load dynamics is studied by investigating qualitative changes in its behavior as the reactive power demand at a load bus is increased. The load is created using induction motors parallel with the constant power and constant impedance load. As the load increases, the system experiences various bifurcations such as sub critical and supercritical Hopf, period-doubling and saddle-node bifurcation. The latter may lead the system to voltage collapse. A nonlinear controller is used to control the subcritical Hopf bifurcation and hence mitigate voltage collapse. It is applied to the KEPCO (Korean Electric Power Company) system to demonstrate its validity.

Development of a Multiplexing Method for Multi-System Control (복수시스템 제어를 위한 멀티플랙싱 기법 개발)

  • Oh, Dong-Jin;Yoon, Sang-Jin;Cho, Yong-Seok;Park, Ki-Heon
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.2542-2544
    • /
    • 2000
  • In this paper, CAN(Controller Area Network)is used to solve the wire harness problem in the outside mirror of automobile which has a lot of functions in narrow space. If the number of wires is reduced, it has benefits of lower product cost and maintenance. CAN was originally developed by the German company Robert Bosch for use in the car industry to provide a cost-effective communications bus for in car electronics and as alternative to expensive and cumbersome wiring looms. CAN controller is a serial communication protocol which efficiently supports distributed real-time control with a very high level of security. The communication between master CAN controller and slave CAN controller is realized and controller's performance is tested by experiment.

  • PDF

Power System Oscillations Damping Using UPFC Based on an Improved PSO and Genetic Algorithm

  • Babaei, Ebrahim;Bolhasan, Amin Mokari;Sadeghi, Meisam;Khani, Saeid
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.1
    • /
    • pp.135-142
    • /
    • 2012
  • In this paper, optimal selection of the unified power flow controller (UPFC) damping controller parameters in order to improve the power system dynamic response and its stability based on two modified intelligent algorithms have been proposed. These algorithms are based on a modified intelligent particle swarm optimization (PSO) and continuous genetic algorithm (GA). After extraction of UPFC dynamic model, intelligent PSO and genetic algorithms are used to select the effective feedback signal of the damping controller; then, to compare the performance of the proposed UPFC controller in damping the critical modes of a single-machine infinite-bus (SMIB) power system, the simulation results are presented. The comparison shows the good performance of both presented PSO and genetic algorithms in an optimal selection of UPFC damping controller parameters and damping oscillations.

A Study on the Optimum Design of Warm-up rate in a Air-Heated Heater System by Using CFD Analysis and Taguchi Method (전산유체해석과 다구찌 방법을 연계한 공기 가열식 히터 시스템의 난방속효성 최적화에 관한 연구)

  • Kim, Min-Ho
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.2
    • /
    • pp.72-82
    • /
    • 2005
  • The objective of this paper is to describe the optimization of design parameters in a large-sized commercial bus heater system by using CFD(computational fluid dynamics) analysis and Taguchi method. In order to obtain the best combination of each control factor which results in a desired performance of heater system, the parameter design of the Taguchi method is adopted for the robust design considering the dynamic characteristic. The research activity may be divided into four phases. The first one is analyzing the problem, i.e., ascertaining the influential factors. In the second phase the levels were set in such a way that their variation would significantly influence the response. In the third phase the experimental runs were designed. In the final phase the planned runs were carried out numerically to evaluate the optimal combination of factors which is able to provide the best response. In this study, eight factors were considered for the analysis: one with two level and seven with three level combinations comprising the $L_{18}(2^1{\times}3^7)$ orthogonal array. The results of this study can be summarized as follows ; (i)The optimum condition of control factor is a set of <$A_2\;B_1\;C_3\;D_3\;E_1\;F_2\;G_3\;H_2$> where A is shape of the outer fin, B is pitch of the outer fin, C is height of the outer fin, D is the inner fin number, E is the inner fin height, F is length of the flame guide, G is diameter of the heating element and H is clearance between air guide and heating element. (ii)The heat capacity of heated discharge air under the optimum condition satisfies the equation y=0.6M w here M is a signal factor. (iii)The warm-up rate improves about three times, more largely as com pared with the current condition, which results in about 9.2minutes reduction.

Suggestion for Safety Improvement of Compressed Natural Gas Vehicle (압축천연가스 자동차의 안전성 향상을 위한 제언)

  • Kim, Young-Seob;Park, Kyo-Shik;Kim, Tae-Ok
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.4
    • /
    • pp.1-7
    • /
    • 2012
  • Systematic safety research by Korea Government has been made to enhance the safety of CNG (compressed natural gas) vehicles since the burst of compressed cylinder of an urban bus in August 9, 2010. This article summarizes some major activities to ensure the safety of CNG vehicles, which covers review of regulation, safety management system including standard of inspection and certification, and training program of inspectors and car mechanics. Specifically, the followings were reviewed; type of CNG cylinder, location of CNG cylinder, material and type of fuel line and vent line, modification of pipeline connection, installation of gas detector, installation of emergency shutdown valve, installation of protecting cover for cylinder, obligations for CNG vehicle filling station. improving periodical inspection, routine test on gas vehicles, training program for engaged in gas vehicles, and designation of safety manager for CNG bus company. This paper suggests how to improve safety of CNG vehicles as a result of review of above mentioned check items.