• 제목/요약/키워드: Buried Type

검색결과 208건 처리시간 0.027초

유리섬유 보강재를 삽입한 하악 레진의치 인상면의 정밀성 평가 (Precision evaluation of impression surface of lower complete dentures reinforced with glass fiber)

  • 김동연;양천승;이광영;김지환
    • 대한치과기공학회지
    • /
    • 제42권1호
    • /
    • pp.27-33
    • /
    • 2020
  • Purpose: This study is to compare and analyze the precision of glass fiber resin dentures. Methods: A lower edentulous model was prepared. Ten study models were produced using Type IV stone. Ten wax lower resin dentures containing artificial teeth were prepared. The lower wax denture was buried with plaster and deflasking was performed to remove the wax. Five conventional lower resin dentures and five glass fiber lower resin dentures were produced. The scanning spray was coated on the impression surface and then scanned. Independent sample t-test were performed using statistical software. Results: In the color different map, which is a qualitative evaluation, the green area of the precision of the conventional lower resin denture occupied the whole. The glass fiber conventional resin dentures had many negative and positive area. In quantitative evaluation, the RMS of conventional lower resin was 89.83 ㎛ and that of fiberglass resin was 224.92 ㎛. The two groups showed statistically significant differences (p<0.05). Conclusion: Conventional lower resin dentures were superior in precision, and glass fiber resin dentures would have to improve the process.

ITO박막과 ITO/p-InP 태양전지의 제작 및 특성 (The Fabrication and Characteristics of ITO Thin Films and ITO/p-InP Solar Cells)

  • 맹경호;문동찬;송복식;김선태
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1992년도 춘계학술대회 논문집
    • /
    • pp.105-109
    • /
    • 1992
  • ITO film, 1500${\AA}$ of thickness, onto glass and p-InP wafer was prepared by e-beam evaporator. The bet ITO film had the resistivity 5.3${\times}$10$\^$-3/ $\Omega$-cm, the concentration 6.5${\times}$10$\^$20/cm$\^$-3/, the transmittance above 80%, and the optical energy gap about 3.5eV. The higher pressure of injected oxygen, the less reverse bias saturation current and the more open circuit voltage. Under the optimum evaporation conditions, the efficiency was 7.19% and the series resistance, and the shunt resistance were respectively 8.5%, 3${\alpha}$, and 26K$\Omega$. The interdependence between activation energy and pre-exponential factor was found. We found he surface of the p-InP became n-type and consquently supposed that the buried homojunction formation, that is, n+-ITO/n-InP/p-InP was caused by Sn diffusion or loss of phosphorus in the interface layer.

  • PDF

해양플랜트용 라티스 붐 크레인의 최적 설계에 관한 연구 (A Study on the optimal design of lattice boom crane for offshore plant)

  • 김현지;김지혜;박상혁;최시연;허선철
    • 한국산업융합학회 논문집
    • /
    • 제22권6호
    • /
    • pp.757-765
    • /
    • 2019
  • In manufacturing An offshore plant is a structure that produces resources buried in the seabed. It can be classified into fixed, floating, and hybrid methods depending on the installation method. In particular, the Lattice boom type crane is typically used because it is used for a long time in the sea and moves to other seas, which is less affected by wind. In this study, the crane was designed by using three-step optimization design in the early stage of the design of Lattice boom crane for offshore plant. Finite element analysis was performed to verify the safety factor, deflection, buckling coefficient and fatigue life of the designed crane and the results were verified.

도시가스 매설배관 보수기준 개발에 관한 연구 (A Study on the Development of the Repair Standards for Underground Pipelines Carrying Natural Gas)

  • 류영돈;이진한;조영도
    • 한국가스학회지
    • /
    • 제20권4호
    • /
    • pp.33-43
    • /
    • 2016
  • 미국과 유럽의 가스회사에서는 배관의 보수방법으로 그라인딩, 육성용접, 슬리브덮개용접, 복합재료보수, 핫태핑, 클램프 등 다양한 방법을 사용하고 있으며, 배관에 손상이 발생한 경우 사용적합성 평가를 거쳐 배관보수를 실시하고 있다. 또한, 미국과 영국 등에서는 매설된 도시가스배관이 타공사 또는 부식으로 인해 손상을 입은 경우 손상형태별로 적용 가능한 배관보수방법을 규정하고 있다. 국내의 경우에는 노후된 중압배관에 대하여 정밀안전진단을 하도록 하고 있으며, 정밀안전진단결과 발생된 결함의 종류 및 정도에 따라 배관을 보수, 교체 또는 신설하도록 규정하고 있다. 그러나 보수 및 보강 방법에 대하여는 기준이 마련되어 있지 않아 배관에 손상이 발생한 경우 주로 손상된 배관을 절단한 후 단관(短管)으로 교체하는 방법만을 사용하고 있다. 본 논문에서는 미국, 영국 등 국외의 보수방법 및 기준을 조사하고, 국내의 매설배관 검사 방법 등에 대해 조사하고, 보수방법 시험 결과를 분석한 후 국내 실정에 맞는 배관보수기준(안)을 제시하였다. 개발되는 기준에 따라 도시가스사업자가 정밀안전진단 결과의 후속조치로 배관보수를 하는 경우 가스공급을 중단하지 않아도 되므로 가스의 안정적 공급에 기여할 수 있을 것으로 판단된다.

충청남도 녹도해역의 인공어초 효과와 상태에 관한 연구 (A Study on the Research Condition and Efficiency of Artificial reefs of Rokdo Sea region of Chungnam Province)

  • 박종수;서만석;김지현
    • 수산해양교육연구
    • /
    • 제13권1호
    • /
    • pp.87-98
    • /
    • 2001
  • 1. The bottom mean size of the research area had been showed 86.8% in, 13.2% in mud artificial sector, but and 82.4% in mud at comparative sector. 2. The water temperature had been showed $11.2{\sim}12^{\circ}C$ in surface, $10.9^{\circ}C$ in mid layer, $10.6{\sim}10.8^{\circ}C$ in lower layer. also, The salinity had been showed $31.85{\sim}31.95_{psu}$ in surface, $31.82{\sim}31.97_{psu}$ in mid layer, $31.85{\sim}31.97_{psu}$ at lower layer. The transparency was showed 3.6~5.6m. 3. The conservation condition of reefs was partially grooved and buried the lower part of reefs established '95~'96years but was good condition generaly. 4. The attached fauna has been appeared fisheres botanical specise 6, fisheries animate species 5. 5. The lure of fisheres has been appeared 17 species in reefs sector, 10 species in comparative sector(natural fishing ground). 6. The catchs of C.P.U.E by fishery was catched 2.2~3.3 times in reefs sector than the natural fishing ground. but the individuals was much catched in traps. The jumbo type reefs gill netter were much catched in square artificial reefs. The weight of fishery was much captured in jumbo type reefs.

  • PDF

해양 물리적 영향에 따른 강원도 해역에 시설된 2가지 인공어초의 보존상태 조사 (Investigation of conservation state of two types artificial reef on physical factors, immersed in Gang won coastal waters of the East Sea)

  • 이지현;김완기;안정미;이채성
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제34권1호
    • /
    • pp.168-176
    • /
    • 2010
  • 인공어초의 안정성과 내구성에 대한 관심은 최근 크게 주목을 받고 있다. 본 연구에서는 사이드 스켄소나와 멀티빔에코사운더, 잠수조사를 통하여 어초의 안정성, 시설년도, 종류를 조사하였다. 그 결과 4개의 조사해역(양양, 강릉, 동해 및 삼척)에서 총 8,438개(60개의 단위어초군)가 시설되어 있는 것을 확인하였다. 그리고 그 중 85.4%가 안정한 시설 상채를 나타냈으며 나머지 14.6%가 해양의 물리적인 변수에 의해서 영향을 받은 것으로 나타났다. 대표적으로는 파손(6.3%)과 전도(8.3%)현상이 있다. 단위 어초군별로는 61.7%가 안정한 상태를 나타냈으며, 38.3%가 해양의 물리적인 영향을 받은 것으로 나타났다. 대표적인 현상은 매몰이었다.

지중 금속구조물 부식감시를 위한 영구매설용 기준전극 개발 (Development of Permanent Reference Electrode for Corrosion Monitoring of Underground Metallic Structures)

  • 하윤철;배정효;하태현;이현구;이재덕;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.532-534
    • /
    • 2004
  • The advancement of electronics and telecommunication technologies has forced the risk management system for underground metallic structures to evolve into the remote monitoring and control system. Especially, facilities such as gas pipelines, oil pipelines and water distribution lines might make hazardous effect on human safety without continuous monitoring and control. As a result, pipeline engineers have applied cathodic protection system to prevent the degradation of their facilities by corrosion and carried out a periodic monitoring of the pipe-to-soil (P/S) potentials at numberous test boxes along their pipelines. The latter action on a road in downtowns, however, is so much dangerous that the inspectors should be ready to suffer the threatening of their lives and maintenance. In order to minimize these social costs and hazards, a stand-alone type corrosion monitoring equipment which can be installed in test box, store the P/S data for given Belied and send the data by wired/wireless telecommunications is under development. In order to obtain the exact P/S data, however, a reference electrode should be located as close to the pipeline as possible. Actually, the measured potential by a conventional portable reference electrode contain inevitably an IR drop portion caused by the current flow from the cathodic protection rectifier or the subway railroad. To minimize this error, it is recommended that the reference electrode should be buried within 10 cm from the pipeline. In this paper, we describe the design parameters for fabricating the permanent type reference electrode and the characteristics of the developed reference electrode.

  • PDF

THE COMBINATION OF CHEMOMETRICS AND 2D NIR CORRELATION SPECTROSCOPY IN THE ANALYSIS OF DENATURATION PROCESS

  • Czarnik-Matusewicz, Boguslawa;Murayama, Koichi;Wu, Yuqing;Ozaki, Yukihiro
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1286-1286
    • /
    • 2001
  • Despite extensive theoretical and experimental studies the structure of the protein-solvent interface is subject of many controversy. Understanding the processes that occur in aqueous solution requires understanding of the solvent influence on the structure of protein. The aim of this study is to investigate the applicability of NIR methods in the study of hydration phenomena in protein solutions. Temperature-induced changes in NIR spectra of -lactoglobulin (BLG) in aqueous solutions have been investigated by means of two-dimensional correlation spectroscopy (2DCOS) and principal component analysis (PCA). With the temperature increase the balance of forces between the BLG's interaction with itself and the BLGs interaction with its environment is disrupted leading to BLG unfolding. Significant differences of 2D signals and distinct discrepancies of loading on PC1 and PC2 were observed as a result of temperature increase. In the native folded conformation of BLC, most of the nonpolar amino acids are hidden in the centre of the structure, out of contact with water molecules, while charged groups are outside, in the contact with water. The polar groups promote low density Ih-type structure in the water outside this first hydration shell. When BLG unfolds it assumes a more extended configuration on which the previously buried nonpolar groups are exposed to water and promote the higher density II-type structure outside its first shell. Detailed assignments of bands attributed to the bulk water, different states of the hydrated water and the changed conformation of BLG are proposed.

  • PDF

돼지사체 매몰지역 지하수의 수지구화학 특성: 침출수 누출 판단 (Hydrochemical Characteristics of Groundwater in an Area Affected by Pig Carcass Burial: Leakage Detection)

  • 오준섭;김호림;이정호;김경호;최광준;김현구;윤성택
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제23권1호
    • /
    • pp.30-40
    • /
    • 2018
  • To evaluate potential impacts of shallow groundwater by the leachate from buried carcass, we investigated hydrochemical characteristics of both leachate and shallow groundwater from monitoring wells and surrounding shallow groundwater wells in an area potentially affected by pig carcass burial. The hydrochemical survey was conducted before and after the relocation of a burial pit. The leachate samples and the groundwater affected by leachate showed the hydrochemistry of $Ca-HCO_3$ type with high $NH_4{^+}$ concentrations, while unaffected groundwater was mostly the $Ca(Na)-Cl+NO_3$ type due to pervasive impacts from agrochemicals. The results of factor analysis on hydrochemical data showed the followings: 1) contamination of groundwater from agro-livestock farming and livestock burial are coexisting in the study area, 2) among ionic species, $HCO_3{^-}$, $NH_4{^+}$, $NO_3{^-}$ and Mn are very useful to differentiate the groundwater contamination from leachate, and 3) groundwater contamination by leachate has been recognized around the monitoring wells even after the relocation of a burial pit, likely due to residual contaminants in surrounding soils. Therefore, it is suggested that continued monitoring of groundwater contamination should be conducted after the relocation of carcass burial pits.

LED조명등기구 디자인 개발을 위한 형태적 속성 분석에 관한 연구 (A Study on the Analysis of the Morphological Attributes for the Design Development of LED Lighting Fixtures)

  • 윤봉식;조광수
    • 스마트미디어저널
    • /
    • 제5권4호
    • /
    • pp.103-110
    • /
    • 2016
  • 본 연구는 유사 목적을 가진 제품들을 형태적 특성에 따라 분류하고, 기능적 유사성을 기반으로 범주화하여 전형성 추출함으로써 기구디자인 개발 시, 개발방향의 기준 마련에 목적을 둔다. 전형성 추출을 위한 본 연구의 표본영역은 선험 사례연구와 전문가자문을 통해 팬던트형과 천정부착형으로 제한을 두고, 한국과 일본에 출시된 2015년 12월 이전 출시 제품을 표본으로 국내 주요 6개 도시 관련업무 종사자 및 전공자를 대상으로 조사를 실시하였다. 조사는 형태적 분류를 위한 1차 조사와 전형성 추출에 관한 2차 조사, 형태적 디자인속성 분류에 관한 3차 조사로 이루어졌으며, 기능 및 형태적 분류와 조형원리를 기준으로 디자인 속성을 도출하고 개별 요소를 추출함으로써 디자인 가중치 측정에 대한 향후 연구의 기반을 마련하고자 하였다. 연구결과의 산업적 적용으로 광원 대체로 인한 조명기구 시장변화에 디자인기술의 효율적 역할 정립과 기업의 연구개발 및 조명기구관련 제품디자인 타입 변화 가속화에 신속한 대응방향 제시 효과를 기대할 수 있다.