• 제목/요약/키워드: Bulk type

검색결과 639건 처리시간 0.025초

히터트리거를 이용한 고온초전도전원장치의 제작 및 특성 실험에 관한 연구 (The Fabrication and Characteristic Experiment of a Heater-Trigger type High-Tc Superconducting Power Supply)

  • 윤용수;김호민;추용;이창열;고태국;한태수
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권9호
    • /
    • pp.484-489
    • /
    • 1999
  • This paper deals with the design and fabrication of a heater-trigger type high-Tc superconducting power supply system, and characteristics have been analyzed through experiments. The high-Tc superconducting power supply consists of two heater trigger and electric magnet, and YBCO superconducting bulk. In this experiment, 0.6T class magnet and dc 2.3A heater current are used, and the current-pumping characteristics have been analyzed with computer aided sequence control system. Hall sensors are installed on the YBCO bulk and in the center of iron core in order to analyze the effect of the flux-pumping on the system with when magnet flux changes its value. In this experiment, maximum pumping-current has been achieved to about 6.6 amps.

  • PDF

대기 모형에서의 벌크형 미세구름물리 모수화 방안 (Bulk-Type Cloud Microphysics Parameterization in Atmospheric Models)

  • 임교선
    • 대기
    • /
    • 제29권2호
    • /
    • pp.227-239
    • /
    • 2019
  • This paper reviews various bulk-type cloud microphysics parameterizations (BCMPs). BCMP, predicting the moments of size distribution of hydrometeors, parameterizes the grid-resolved cloud and precipitation processes in atmospheric models. The generalized gamma distribution is mainly applied to represent the hydrometeors size distribution in BCMPs. BCMP can be divided in three different methods such as single-moment, double-moment, and triple-moment approaches depending on the number of prognostic variables. Single-moment approach only predicts the hydrometeors mixing ratio. Double-moment approach predicts not only the hydrometeors mixing ratio but also the hydrometeors number concentration. Triple-moment approach predicts the dispersion parameter of hydrometeors size distribution through the prognostic reflectivity, together with the number concentrations and mixing ratios of hydrometeors. Triple-moment approach is the most time expensive method because it has the most number of prognostic variables. However, this approach can allow more flexibility in representing hydrometeors size distribution relative to single-moment and double-moment approaches. At the early stage of the development of BMCPs, warm rain processes were only included. Ice-phase categories such as cloud ice, snow, graupel, and hail were included in BCMPs with prescribed properties for densities and sedimentation velocities of ice-phase hydrometeors since 1980s. Recently, to avoid fixed properties for ice-phase hydrometeors and ad-hoc category conversion, the new approach was proposed in which rimed ice and deposition ice mixing ratios are predicted with total ice number concentration and volume.

인가 자기장에 의한 YBCO 초전도체 복합체의 포획 자기장 특성 (The Trapped Field Characteristics of YBCO Superconductor Composite in Terms of Applied Magnetic Field)

  • 이만수;장건익;최연석;전병혁;한영희;박병준
    • Progress in Superconductivity
    • /
    • 제12권1호
    • /
    • pp.12-16
    • /
    • 2010
  • We have measured the trapped field of YBCO bulk with different configuration by applying the magnetic field of $Nb_3Sn$ superconducting magnet. Initially the circular type of YBCO bulk superconductor was prepared and then hole, parallel to the c-axis and located at the center of bulk was mechanically drilled. The YBCO bulk with hole was filled with resin. Typical size of hole in YBCO bulk was 10 mm in diameter. Trapped field characteristics were compared with different specimen conditions. Our preliminary result indicates the increment rate of trapped field, 0.232 kG, measured on the YBCO without hole was much higher than that, 0.011 kG, measured on YBCO with hole.

Comparison of Surface Microhardness of the Flowable Bulk-Fill Resin and the Packable Bulk-Fill Resin according to Light Curing Time and Distance

  • Hyung-Min Kim;Moon-Jin Jeong;Hee-Jung Lim;Do-Seon Lim
    • 치위생과학회지
    • /
    • 제23권2호
    • /
    • pp.123-131
    • /
    • 2023
  • Background: As a restorative material used to treat dental caries, the light-curing type resin is widely used, but it has the disadvantage of polymerization shrinkage. The Bulk-Fill composite resin was developed to solve these shortcomings, but the existing research mainly focused on comparing the physical properties of a composite resin and a Bulk-Fill resin. A study on the light curing time and distance of the Bulk-Fill resin itself tend to be lacking. Methods: This study compares the surface microhardness of specimens prepared by varying the light curing time and distance of smart dentin replacement (SDR) as a flowable Bulk-Fill resin and Tetric N-ceram as a packable Bulk-Fill resin, and confirms the polymerization time and distance that becomes the optimum hardness. To determine the hardness of the specimen, it was measured using the Vickers Hardness Number (Matsuzawa MMT-X, Japan). Results: In SDR, the surface microhardness decreased as the distance increased in all time groups in the change distance from the curing tip. In the change of light curing time with respect to the distance from curing tip, the surface microhardness increased as the time increased. In Tetric N-ceram, the surface microharness showed no significant difference in the change of the distance of curing tip in the group of 20 and 60 second. But in the group of 10 and 40 seconds, decreased as the distance increased. The surface microharness increased as the light curing time increased in all distance groups. Conclusion: When using SDR and Tetric N-ceram in clinical practice, it is considered that as the distance from the polymerization reactor tip increases, a longer light curing time than the polymerization time recommended by the manufacturer is required.

고주파 임피던스를 이용한 곡류의 함수율 측정에 관한 연구 (I) - 곡류의 전기적 특성 구명 - (Measurement of Grain Moisture Content using RF Impedance (I) - Electrical Properties of Grain -)

  • 김기복;노상하
    • Journal of Biosystems Engineering
    • /
    • 제24권2호
    • /
    • pp.123-134
    • /
    • 1999
  • The electrical properties such as dielectric constant, dielectric loss factor and AC conductivity of grain were presented to measure the moisture content of grain using RF impedance. At frequency ranging from 1 to 10MHz and room temperature, $20^{\circ}C$, vector network analyzer(HP4195) and coaxial type sample holder were used to analyze the electrical properties of paddy(11∼24%w.b.), brown rice(11∼18%w.b.), barley(11∼21%w.b.) and wheat(11∼23%w.b.) depending on the moisture content, frequency and bulk density. The dielectric constant and AC conductivity of grain samples increased with moisture content and bulk density. The dielectric constants decreased with frequency and could be expressed as function of the moisture density(decimal moisture $content{\times}bulk$ density).

  • PDF

수소용 다이어프램 압축기의 작동유 특성에 따른 수치해석 (Numerical Analysis on a Dependence of Hydrogen Diaphragm Compressor Performance on Oil Characteristics)

  • 박현우;신영일;이영준;송주헌;장영준;전충환
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.787-790
    • /
    • 2009
  • There are several types of compressors which are appropriate for hydrogen gas station. Metal diaphragm type of hydrogen compressor is the one of them, a use in which satisfies the requirements of maintaining gas purity and producing high pressure over 700 bar. The objective of this study is to investigate an characteristics of compression as bulk modulus of oil varies. Three cases of bulk modulus ranging from $2{\times}10^9$, $4.52{\times}10^9$ and $7{\times}10^9$ were studied through FSI (Fluid Structure Interaction) analysis. Gas pressure, oil pressure and deflection degree of diaphragm were analysed during a certain period of compression process. Highest pressure and deflection were found in the condition of high bulk modulus of $7{\times}10^9$.

  • PDF

Printing Technology for Bulk-Heterojunction Organic Photovoltaic Cells: Inkjet and Aerosol-Jet Printing

  • 윤성철;정재욱;김동환;임종선;이창진
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2009년도 춘계학술발표대회
    • /
    • pp.11.1-11.1
    • /
    • 2009
  • Bulk-heterojunction type organic photovoltaic cells have been remarkably improved due to the development of efficient donors and post treatment process. However, most of researchers have studied on the OPVs using spin-coating method during the past decade. To commercialize the OPVs, much cheaper printing process should be developed such as inkjet, screen, gravure, and so on. In this study, we have focused on the development of printing technology using Inkjet and Aerosol-Jet printing, which can offer reliable device performance. Finally, 4.5% power conversion efficiency can be achieved under AM 1.5 1sun light illumination, which is the highest value in printed OPVs. We reveal that substantial improvement can be realized by highly efficient bulk heterojunction after printing. Also, we can confirm these two printing methods are promising fabrication methods for large area OPVs. Also, flexible and large area (18 cm2) printed OPVs have been fabricated and device performance will be discussed in detail.

  • PDF

Realization of Two-bit Operation by Bulk-biased Programming Technique in SONOS NOR Array with Common Source Lines

  • An, Ho-Myoung;Seo, Kwang-Yell;Kim, Joo-Yeon;Kim, Byung-Cheul
    • Transactions on Electrical and Electronic Materials
    • /
    • 제7권4호
    • /
    • pp.180-183
    • /
    • 2006
  • We report for the first time two-bit operational characteristics of a high-density NOR-type polysilicon-oxide-nitride-oxide-silicon (SONOS) array with common source line (CSL). An undesired disturbance, especially drain disturbance, in the NOR array with CSL comes from the two-bit-per-cell operation. To solve this problem, we propose an efficient bulk-biased programming technique. In this technique, a bulk bias is additionally applied to the substrate of memory cell for decreasing the electric field between nitride layer and drain region. The proposed programming technique shows free of drain disturbance characteristics. As a result, we have accomplished reliable two-bit SONOS array by employing the proposed programming technique.

Optimization of the experimental conditions for determination of roxithromycin in bulk and dosage forms

  • Jeong, Kyung Min;Lee, Cheong Hoon;Kim, Su Hyun;Lee, Jeongmi
    • 분석과학
    • /
    • 제30권1호
    • /
    • pp.39-48
    • /
    • 2017
  • Roxithromycin (RXT), which is an antibiotic used to treat respiratory tract and urinary infections, is official in Korean Pharmacopoeia (KP) and is marketed in various dosage forms including tablet, granule, suspension, and tablet for suspension in Korea. This study presents how a universal and reliable method to quantify RXT in bulk drug and formulations was developed. Effects of factors including column type, buffer concentration, type and concentration of organic solvent, buffer pH, and type and concentration of mobile phase additive, were examined, and some categorical or crucial factors including the types of column, organic solvent, mobile phase additive and the buffer pH were optimized by one-factor-at-a-time approach. Subsequently, concentrations of the buffer and additive and column temperature were optimized by response surface methodology using Box-Behnken design aiming to acquire the RXT peak of good shape. The optimized method employed a Phenomenex Gemini $5{\mu}$ C18 110A ($150{\times}4.60mm$, $5{\mu}m$) maintained at $30^{\circ}C$ with the mobile phase consisting of 25 mM phosphate buffer (pH 6.0) with 0.3 % tetrabutylammonium hydroxide and methanol at a ratio of 37:63 (v/v). Method validation results showed that the developed method was linear, precise, and accurate. Compared to the compendial methods in KP 10 that exhibited a significant tailing of the RXT peak despite using unfavorably high buffer concentrations and were not harmonized among bulk drug and formulations, this method could be universally applied to RXT bulk drug and marketed products in various dosage forms and thus was adopted in KP 11.

Errors in light-emitting diodes positioning when curing bulk fill and incremental composites: impact on properties after aging

  • Abdulrahman A. Balhaddad;Isadora M. Garcia;Haifa Maktabi;Maria Salem Ibrahim;Qoot Alkhubaizi;Howard Strassler;Fabricio M. Collares;Mary Anne S. Melo
    • Restorative Dentistry and Endodontics
    • /
    • 제46권4호
    • /
    • pp.51.1-51.13
    • /
    • 2021
  • Objectives: This study aimed to evaluate the effect of improper positioning single-peak and multi-peak lights on color change, microhardness of bottom and top, and surface topography of bulk fill and incremental composites after artificial aging for 1 year. Materials and Methods: Bulk fill and incremental composites were cured using multi-peak and single-peak light-emitting diode (LED) following 4 clinical conditions: (1) optimal condition (no angulation or tip displacement), (2) tip-displacement (2 mm), (3) slight tip angulation (α = 20°) and (4) moderate tip angulation (α = 35°). After 1-year of water aging, the specimens were analyzed for color changes (ΔE), Vickers hardness, surface topography (Ra, Rt, and Rv), and scanning electron microscopy. Results: For samples cured by single-peak LED, the improper positioning significantly increases the color change compared to the optimal position regardless of the type of composite (p < 0.001). For multi-peak LED, the type of resin composite and the curing condition displayed a significant effect on ΔE (p < 0.001). For both LEDs, the Vickers hardness and bottom/top ratio of Vickers hardness were affected by the type of composite and the curing condition (p < 0.01). Conclusions: The bulk fill composite presented greater resistance to wear, higher color stability, and better microhardness than the incremental composite when subjected to improper curing. The multi-peak LED improves curing under improper conditions compared to single-peak LED. Prevention of errors when curing composites requires the attention of all personnel involved in the patient's care once the clinical relevance of the appropriate polymerization reflects on reliable long-term outcomes.