• Title/Summary/Keyword: Built-in Type

Search Result 1,271, Processing Time 0.033 seconds

Built-In Self Repair for Embedded NAND-Type Flash Memory (임베디드 NAND-형 플래시 메모리를 위한 Built-In Self Repair)

  • Kim, Tae Hwan;Chang, Hoon
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.3 no.5
    • /
    • pp.129-140
    • /
    • 2014
  • BIST(Built-in self test) is to detect various faults of the existing memory and BIRA(Built-in redundancy analysis) is to repair detected faults by allotting spare. Also, BISR(Built-in self repair) which integrates BIST with BIRA, can enhance the whole memory's yield. However, the previous methods were suggested for RAM and are difficult to diagnose disturbance that is NAND-type flash memory's intrinsic fault when used for the NAND-type flash memory with different characteristics from RAM's memory structure. Therefore, this paper suggests a BISD(Built-in self diagnosis) to detect disturbance occurring in the NAND-type flash memory and to diagnose the location of fault, and BISR to repair faulty blocks.

Pattern Testable NAND-type Flash Memory Built-In Self Test (패턴 테스트 가능한 NAND-형 플래시 메모리 내장 자체 테스트)

  • Hwang, Phil-Joo;Kim, Tae-Hwan;Kim, Jin-Wan;Chang, Hoon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.6
    • /
    • pp.122-130
    • /
    • 2013
  • The demand and the supply are increasing sharply in accordance with the growth of the Memory Semiconductor Industry. The Flash Memory above all is being utilized substantially in the Industry of smart phone, the tablet PC and the System on Chip (SoC). The Flash Memory is divided into the NOR-type Flash Memory and the NAND-type Flash Memory. A lot of study such as the Built-In Self Test (BIST), the Built-In Self Repair (BISR) and the Built-In Redundancy Analysis (BIRA), etc. has been progressed in the NOR-type fash Memory, the study for the Built-In Self Test of the NAND-type Flash Memory has not been progressed. At present, the pattern test of the NAND-type Flash Memory is being carried out using the outside test equipment of high price. The NAND-type Flash Memory is being depended on the outside equipment as there is no Built-In Self Test since the erasure of block unit, the reading and writing of page unit are possible in the NAND-type Flash Memory. The Built-In Self Test equipped with 2 kinds of finite state machine based structure is proposed, so as to carry out the pattern test without the outside pattern test equipment from the NAND-type Flash Memory which carried out the test dependant on the outside pattern test equipment of high price.

Application Standards for Substation Types and Facility Scales (변전소 형태 및 설비규모의 결정)

  • Min, Byeong-Wook;Shin, Myoung-Sik;Bahng, Seon-Woong;Kim, Young-Dal
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.438-439
    • /
    • 2011
  • Substations in Korea are classified into an outdoor steel structure type, an outdoor GIS(Gas Insulated Switchgear) type, an indoor GIS type, an underground GIS type, and a complex GIS type. Before 1970, substations were built in outdoor steel structure types only. In 1980, an 154kV indoor GIS type substation was built for the first time in Pusan. And the first 345kV indoor GIS type substation, the first 765kV full GIS substation were built in 1984 and in 2002 each. In 1998, 154kV indoor type substations were standardized into regular type and urban type which applied steel frames to structures. In 2002, this was re-standardized into five different types in detail. In 2007, hub substations which had high capacity were built in the region of industrial zone and heavy load areas. And 154kV compact substation was developed and standardized by compacting an indoor GIS type substation in 2009. This paper would present a series of substation type transition and application standards for substation types and facility scales.

  • PDF

A Study on the Types of the Modern Architecture by the Builders in Taegu Province (대구지역(大邱地域) 근대건축(近代建築)의 건립주체별(建立主體別) 유형분석(類型分析)에 관한 연구)

  • Yoon, Jae-Woong
    • Journal of architectural history
    • /
    • v.1 no.1 s.1
    • /
    • pp.129-141
    • /
    • 1992
  • The purpose of this study was to investigate type of the modern architecture in Daegu province, based on 91 buildings which were built from 1886 to 1945 in Daegu province. The results of this study could be summarized as follows : The modern buildings were built by the western missionary, Japanese, Chineses and Korean. The catholic, built Korean style cathedral and parsonage early in the missionary period, then changed to build Gothic revival and georgian style masonary buildings. The protestant built eclectic buildings. With masonary structure and Korean roof style. Then from 1930's, they started to build Gothic revival style buildings. Japanese built eclectic buildings which mixed with Western and Japan type during the first period. Then, they also started to build Western eclectic building. Chinese built only two buildings during the whole periods and those were Western eclectic style buildings. Korean started to build commercial and school buildings which were Western style from the middle of the second period by nationalist and local commercialist.

  • PDF

A development of intelligent spacer built in the Internal type UHF partial discharge sensor (초고주파 광대역 부분방전 센서를 내장한 지능형 스페이서 개발)

  • Kim, Dong-Suk;Hwang, Chul-Min;Kim, Young-Noh;Choi, Jae-Ok;Seo, Wang-Byuk;Han, Bong-Soo;Choi, Soo-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2007.11a
    • /
    • pp.163-164
    • /
    • 2007
  • In this study, we developed intelligent spacer built in the internal type UHF PD sensors. 3-Dimensional electro-magnetic simulations were performed to analyze electric-field distribution of the single-phase GIS and three-phase GIS. After considering the spacer's specification, Sensor structures were designed and analyzed using the 3-D EM Simulator. As a result of the simulation the internal type UHF PD sensors were built in. Performance of the sensor built into real scale GIS spacer was measured in terms of return loss and detected Max voltage. And we identified a character of the intelligent spacer by using 5pC partial discharge ceil.

  • PDF

A Study on the Development of Stress Tolerant Structural Systems in the Frame of Built-up Greenhouses (내재해형 조립 비닐하우스 골조 구조시스템 개발 연구)

  • Han, Duckjeon;Shim, Jongseok
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.18 no.2
    • /
    • pp.11-18
    • /
    • 2016
  • The collapsing accidents of greenhouse frames have been increased yearly due to strong wind and heavy snow, but as it was, there were few studies about the structural safety of greenhouses. Therefore, this study was carried out to develop the stress tolerant structural frame systems in built-up greenhouses. The vertical loading experiment of developed scale models were implemented and the developed types of models were simulated by 3-D analysis program in this study. These types of models, which are existing type and honeycomb type, in arch and standard style frames were classified. As a result of this study, it was verified that the honeycomb type model of arch style frame is better than the existing type model of it in stress resistance against snow load and wind load.

Development and Construction of 154kV Compact Substation Standard Model (154kV 콤팩트 변전소 표준모델 개발 및 실증)

  • Min, Byeong-Wook;Shin, Myoung-Sik;Kim, Tae-Yong;Hwang, Yoon-Gone;Kim, Young-Dal
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.436-437
    • /
    • 2011
  • Before 1970s, 154kV substations in Korea were built in outdoor steel structure types only. In early 1970s, Germany developed GIS and the first indoor GIS type substation was built in Korea in 1980. In 1998, 154kV indoor type substations were standardized into regular type and urban type which applied steel frames to structures. In 2002, this was re-standardized into five different types in detail. In 2009, 154kV compact substation design was developed and standardized and saved about 20% of the construction cost with new technology and methods. Compact substations were classified into three types ; urban type, multi-function type, and regular type. The first urban type compact substation, Jang-ki substation, was built in Kimpo in June, 2010. This paper would present the standard model of 154kV compact substation and the way of improving facilities for the first compact substation.

  • PDF

A Study on the Thermal Characteristics of the Spindle System with Built-in Motor according to Spindle type (모터내장형 주축계의 구조에 따른 열특성 해석에 관한 연구)

  • 서창범;김수태;최대봉
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.105-110
    • /
    • 2001
  • Unsteady-state temperature distributions for spindle system with built-in motor according to spindle type are studied. For the analysis, three dimensional model is built considering heat transfer characteristics such as natural and forced convection coefficients. Temperature distributions are analyzed by using the finite element method. Results of analysis are compared.

  • PDF

A Study on Control Method for Built-in Type Spindle (Built-in Type 스핀들 구동을 위한 제어방법에 관한 연구)

  • Han S. Y.;Yoon J. M.;Park S. H.;Won C. Y.;Kim Y. R.;Choi C.;Lee S. H.
    • Proceedings of the KIPE Conference
    • /
    • 2003.11a
    • /
    • pp.51-55
    • /
    • 2003
  • In this paper, the authors propose a new high performance Built-in Type spindle motor drive using vector-controlled technique at 15,000 r/min. Control method is changed by variation of motor speed in a conventional Built-in type spindle drive. In the drive system to be presented, the conventional vector control is used in the low-speed range, and the vector control without encoder is used in the high-speed range. Furthermore, in order to drive the motor from 0 to 15,000 rpm smoothly, the vector control with encoder in the low-speed range (from 0 to 8,000 rpm) is utilized and the vector control without encoder in the high-speed range (from 8,000 to 15,000 rpm) is utilized. This paper describes problem of control method in conventional spindle drive and proposes control method as variation of motor speed

  • PDF

Linked Legal Data Construction and Connection of LOD Cloud

  • Jo, Dae Woong;Kim, Myung Ho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.5
    • /
    • pp.11-18
    • /
    • 2016
  • Linked Data is a web standard data definition method devised to connect, expand resources with a standardized type. Linked Data built in various areas expands existing knowledge through an open data cloud like LOD(Linked Open Data). A project to link and service existing knowledge through LOD is under way worldwide. However, LOD project in domestic is being participated in a specific field to the level of research. In this paper, we suggests a method to build the area of technical knowledge like legislations in type of Linked Data, and distribute such Linked Data built to LOD. The construction method suggested by this paper divides knowledge of legislations in structural, semantic, and integrated perspective, and builds each of them by converting to Linked Data according to the perspective. Also, such built Linked Legal Data prepares to link knowledge in a standardized type by distributing them onto LOD. Built Linked Legal Data are equipped with schema for link service in various types, and give help increase understand the access type to existing legal information.