• Title/Summary/Keyword: Building structure

Search Result 4,844, Processing Time 0.03 seconds

Long-term Performance Prediction of Piezoelectric Energy Harvesting Road Using a 3-Dimensional Finite Element Method (3차원 유한요소 해석을 통한 압전에너지 도로의 장기 공용성 예측)

  • Kim, Hyun Wook;Nam, Jeong-Hee;Choi, Ji Young
    • International Journal of Highway Engineering
    • /
    • v.19 no.5
    • /
    • pp.107-115
    • /
    • 2017
  • PURPOSES : The piezoelectric energy road analysis technology using a three-dimensional finite element method was developed to investigate pavement behaviors when piezoelectric energy harvesters and a new polyurethane surface layer were installed in field conditions. The main purpose of this study is to predict the long-term performance of the piezoelectric energy road through the proposed analytical steps. METHODS : To predict the stresses and strains of the piezoelectric energy road, the developed energy harvesters were embedded into the polyurethane surface layer (50 mm from the top surface). The typical type of triaxial dump truck loading was applied to the top of each energy harvester. In this paper, a general purpose finite element analysis program called ABAQUS was used and it was assumed that a harvester is installed in the cross section of a typical asphalt pavement structure. RESULTS : The maximum tensile stress of the polyurethane surface layer in the initial fatigue model occurred up to 0.035 MPa in the transverse direction when the truck tire load was loaded on the top of each harvester. The maximum tensile stresses were 0.025 MPa in the intermediate fatigue model and 0.013 MPa in the final fatigue model, which were 72% and 37% lower than that of the initial stage model, respectively. CONCLUSIONS : The main critical damage locations can be estimated between the base layer and the surface layer. If the crack propagates, bottom-up cracking from the base layer is the main cracking pattern where the tensile stress is higher than in other locations. It is also considered that the possibility of cracking in the top-down direction at the edge of energy harvester is more likely to occur because the material strength of the energy harvester is much higher and plays a role in the supporting points. In terms of long-term performance, all tensile stresses in the energy harvester and polyurethane layer are less than 1% of the maximum tensile strength and the possibility of fatigue damage was very low. Since the harvester is embedded in the surface layer of the polyurethane, which has higher tensile strength and toughness, it can assure a good, long-term performance.

Suggestions on the Estuarine Research Projects for Integrated Estuarine Management in Korea (통합적 하구관리 지원을 위한 우리나라 하구역 연구사업 현황과 정책방향 제언)

  • Cho, Hyun-Jeong;Ryu, Jong-Seong;Lee, Kang-Hyun;Lee, Bum-Yeon;Kang, Dae-Seok;Khim, Jong-Seong;Nam, Jung-Ho;Lee, Chang-Hee
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.16 no.4
    • /
    • pp.212-222
    • /
    • 2011
  • Estuaries have been used competitively and exploited for the past decades in Korea. To preserve the environment of the estuaries from the integrated perspective, new policies have started to change such exploitative development in 2000s. Due to the poor knowledge-base, however, there has been a lack of support system which enables to execute such policies effectively. The present study was conducted to figure out the limits of the estuarine management research projects in Korea, which is being performed to overcome these limitations. It was studied through Gap Analysis between domestic and foreign advanced practices as well as Analytical Hierarchy Process on expert survey in terms of the three aspects: how well the estuarine management research projects in Korea meets the demands of policy making and administration; raises the awareness of citizens about the merit of environmental preservation; and establishes knowledge-based support system. This project turned out to reflect adequately the development of programs for building estuarine management systems. But consideration of other ministries was relatively scarce. But the contents which directly support community-based activities and educational programs to improve citizens' awareness were judged to be insufficient. According to the results of Gap Analysis, research about the structure and function of estuarine ecosystems, which can support to develop policy alternatives in detail, was relatively more necessary. Therefore, to support estuarine policy management effectively, the development of a realistic plan, which can overcome fundamental issues inherent in the Korean environmental management system and the limitation of the estuarine management research projects in Korea itself, is needed.

A Study on the Structural Behavior of the Composite Slab with New-Shaped Deckplate (신형상 데크플레이트를 이용한 합성슬라브의 구조적인 거동에 대한 연구)

  • Huh, Choong;Moon, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.3 s.32
    • /
    • pp.341-350
    • /
    • 1997
  • The objective of this study is to investigate the structural behavior of the composite slabs with the new metal deckplate. The new deckplate can be used as structural member with topping concrete. So several experiments of this structural test and the fire resistance test were done. From this experiments. slabs with new metal deckpklate were verified as composite slabs. In this paper, this verifications were compared with the international design methods. For experiment. 49 specimens were made. the main parameters are deckplate thickness (1.2mm. 1.6mm) depth of topping concrete(85mm. 90mm). support condition(simple, 2-span), shear reinforcment(studs), span(2.7m, 3.0m, 3.3m. 3.6m. 3.9m) and shear span(L/3, L/4, L/7). We analyzed the structural behavior of composite slab throughout the moment-curvature relationship which is obtained with the program using the computer language. Turbo C. From this development for slab system, the reinforced concrete or steel structure building may be easy, economical for construction, And informations about the structural behavior of composite slabs will be utilized to established korea standard.

  • PDF

A Study on the Fire Design Business Development Direction (소방시설설계업의 발전방향에 관한 연구)

  • Hong, Sung-Woo;Lee, Young-Jae;Park, Hung-Joo
    • Fire Science and Engineering
    • /
    • v.23 no.4
    • /
    • pp.67-72
    • /
    • 2009
  • For the fire-fighting industry to advance, it is necessary to conduct research on which parts of the fire-fighting law should be changed from the system level, and to study the opinions of the fire-fighters whoa re working in the fire-fighting industry today, and to identify what needs to be changed. Moreover, it is necessary to become aware on the preventive measures to take to avoid fire so that the citizens can lead stable life. Design business among the fire-fighting facility business, it is the fire-fighting facility business that serves as the most basic when constructing building structure. This is an important legal matter that follows the fire-fighting business, fire-fighting audit business and even the maintenance and management business. This research sought to help the fire-fighting industry to contribute to the life of the general public and to increase welfare by identifying the problems pertaining to the fire-fighting facility design business among the fire-fighting industry so that the industry can become the fire-fighting industry that the citizens are interested in. Moreover, direction for advancement is proposed. As for the improvement measures for the fire-fighting policy pertaining to the fire-fighting facility design business, it is divided into the machinery and electricity fields in terms of the legal system pertaining to the general fire-fighting facility design business. Likewise, specialty in design is deficient. Thus, it should be integrated in a systematic level to contribute to the safety of the general public.

Strength Characteristics of Recycled Concrete by Recycled Aggregate in Incheon Area Waste Concrete (인천지역의 콘크리트 폐기물을 재생골재로 활용한 재생콘크리트의 강도특성)

  • Jang, Jea-Young;Jin, Jung-Hoon;Cho, Gyu-Tae;Nam, Young-Kug;Jeon, Chan-Ki
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.2
    • /
    • pp.197-208
    • /
    • 2003
  • This paper is to determine the possibility of re-using waste concrete from Incheon city area. The strength test was conducted with five aggregate compounds which was replaced a natural aggregate with recycled aggregate. After checking the physical characteristics of recycled aggregate compounds, the mix design of recycled concrete was conducted. For the relatively comparison between natural and recycled compounds, while the unit aggregate weight was changed, other conditions were fixed. The freezing and thawing test which included fly-ash and super-plastezer were performed to check the durability and workability when recycling waste concrete. In the physical characteristics of recycled aggregate, it was found that the specific gravity of recycled coarse aggregate and recycled fine aggregate satisfied the first grade of recycle specification(KS), and all compounds of recycled aggregate also satisfied the second grade of absorption specification, Especially up to the 50% substitution of recycled aggregate is equal to or a bit lower than that of convention aggregate. In comparison with conventional concrete, the recycled concrete is lower than maximum by 7% in compressive strength decreasing rate after freezing-thawing test. From now, although most of recycled concrete was used to the building lot, subgrade, asphalt admixture, through the result. It was proved that possibility of re-using recycled aggregate as the substructure of bridge, retaining wall, tunnel lining and concrete structure which is not attacked the drying shrinkage severely.

Analytical Study on Hybrid Precast Concrete Beam-Column Connections (하이브리드 프리캐스트 보-기둥 접합부의 해석적 연구)

  • Choi, Chang-Sik;Kim, Seung-Hyun;Choi, Yun-Cheul;Choi, Hyun-Ki
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.6
    • /
    • pp.631-639
    • /
    • 2013
  • Non-linear finite element analysis for newly developed precast concrete details for beam-to-column connection which can be used in moderate seismic region was carried out in this study. Developed precast system is based on composite structure and which have steel tube in column and steel plate in beam. Improving cracking strength of joint under reversed cyclic loading, joint area was casted with ECC (Engineering Cementitious Composites). Since this newly developed precast system have complex sectional properties and newly developed material, new analysis method should be developed. Using embedded elements and models of non-linear finite element analysis program ABAQUS previously tested specimens were successfully analyzed. Analysis results show comparatively accurate and conservative prediction. Using finite element model, effect of axial load magnitude and flexural strength ratio were investigated. Developed connection have optimized performance under axial load of 10~20% of compressive strength of column. Plastic hinge was successfully developed with flexural strength ratio greater than 1.2.

A 32${\times}$32-b Multiplier Using a New Method to Reduce a Compression Level of Partial Products (부분곱 압축단을 줄인 32${\times}$32 비트 곱셈기)

  • 홍상민;김병민;정인호;조태원
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.40 no.6
    • /
    • pp.447-458
    • /
    • 2003
  • A high speed multiplier is essential basic building block for digital signal processors today. Typically iterative algorithms in Signal processing applications are realized which need a large number of multiply, add and accumulate operations. This paper describes a macro block of a parallel structured multiplier which has adopted a 32$\times$32-b regularly structured tree (RST). To improve the speed of the tree part, modified partial product generation method has been devised at architecture level. This reduces the 4 levels of compression stage to 3 levels, and propagation delay in Wallace tree structure by utilizing 4-2 compressor as well. Furthermore, this enables tree part to be combined with four modular block to construct a CSA tree (carry save adder tree). Therefore, combined with four modular block to construct a CSA tree (carry save adder tree). Therefore, multiplier architecture can be regularly laid out with same modules composed of Booth selectors, compressors and Modified Partial Product Generators (MPPG). At the circuit level new Booth selector with less transistors and encoder are proposed. The reduction in the number of transistors in Booth selector has a greater impact on the total transistor count. The transistor count of designed selector is 9 using PTL(Pass Transistor Logic). This reduces the transistor count by 50% as compared with that of the conventional one. The designed multiplier in 0.25${\mu}{\textrm}{m}$ technology, 2.5V, 1-poly and 5-metal CMOS process is simulated by Hspice and Epic. Delay is 4.2㎱ and average power consumes 1.81㎽/MHz. This result is far better than conventional multiplier with equal or better than the best one published.

A Study of the Heating Systems used by Korean Compatriot in Russia - Focusing on Yunhaeju, Kazakhstan and Uzbekistan- (러시아에 거주하는 고려인의 난방 방식에 관한 연구 -연해주, 카자흐스탄, 우즈베키스탄을 중심으로-)

  • Lee YoungShim;Cho JaeSoon;Lee SangHae;Joung JaeKook
    • Journal of the Korean Home Economics Association
    • /
    • v.43 no.1 s.203
    • /
    • pp.145-165
    • /
    • 2005
  • In 1937, most Korean compatriot who lived in Yunhaeju moved to Kazakhstan and Uzbekistan in Central Asia following the deportation policy of Russia. Korean compatriot have kept their traditional life style for 140 years, without a deep relationship with Korea. This study examined the heating systems of Korean compatriot in Yunhaeju, Kazakhstan and Uzbekistan, Russia. A literature review and field research, based on Ethnography as a research method, was employed. The results of the research were as following: 1) Korean compatriot in Yunhaeju use a Pechika, which is a radiator that uses hot water, and a Gudul as the main heating systems, but the use of a Pechika was most common. A Pechika functions for cooking as well as for warming the house. The room with the Gudul was connected to the kitchen, so this space was used as a place for cooking and eating, for family members to meet. Many kinds of fuel, like gas and electricity, were used to power the heating systems. 2) Korean compatriot in Kazakhstan use radiators, with hot water as the main heating system, with ratio using Gudul used in this region being the highest of all the three areas. The most common fuels used for a Gudul were wood and coal, and gas was also used in cooking. The room with the Gudul was planned to be located beside the fireplace, without any walls. The people using a Gudul use that place for eating and meeting, as well as for family members to sleep. 3) The main heating system of Korean compatriot in Uzbekistan was a radiator using hot water, and those with pipes containing hot water buried under the floor were very common. The function is very similar to that of a Gudul, so most people using this type of radiator would sleep on the floor. Those people with a traditional Gudul not using them were mostly in Uzbekistan. The reason for this was that the family members had diminished, so it was hard work for elderly parents to manage an extra building containing a Gudul. Gas was the fuel generally used for heating and cooking in Uzbekistan. 4) Guduls were used in the Korean compatriot's houses in all three areas, even though they have changed in structure to adapt to the Russian life style. However, Guduls have still been functioning to maintain a traditional life style in Korean compatriot's houses for the gathering of family members.

Seismic Behavior and Estimation for Base Isolator Bearings with Self-centering and Reinforcing Systems (자동복원 및 보강 시스템과 결합된 면진받침의 지진거동과 평가)

  • Hu, Jong Wan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.5
    • /
    • pp.1025-1037
    • /
    • 2015
  • Flexible base isolation bearings that separate superstructure from ground have been widely used in the construction field because they make a significant contribution to increasing the fundamental period of the structure, thereby decreasing response acceleration transmitted into the superstructure. However, the established bearing devices installed to uphold the whole building give rise to some problems involved with failure and collapse due to lack of the capacity as modern structures are getting more massive and higher. Therefore, this study suggests new isolation bearings assembled with additional restrainers enabled to reinforcing and recentering, and then evaluates their performance to withstand the seismic load. The superelastic shape memory alloy (SMA) bars are installed into the conventional lead-rubber bearing (LRB) devices in order to provide recentering forces. These new systems are modeled as component spring models for the purpose of conducting nonlinear dynamic analyses with near fault ground motion data. The LRB devices with steel bars are also designed and analyzed to compare their responses with those of new systems. After numerical analyses, ultimate strength, maximum displacement, permanent deformation, and recentering ratio are compared to each model with an aim to investigate which base isolation models are superior. It can be shown that LRB models with superelastic SMA bars are superior to other models compared to each other in terms of seismic resistance and recentering effect.

Estimation of Suspended Sediment Concentration in Small Stream with Acoustic Backscatter from Horizontal ADCP based on Real-Scale Field Experiment (실규모 현장 실험 기반 H-ADCP 초음파 산란도 활용 소하천용 하천 부유사 농도 측정 기법 개발)

  • Seo, Kanghyeon;Kim, Dongsu;Son, Geunsoo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.36 no.6
    • /
    • pp.1023-1035
    • /
    • 2016
  • Suspended sediment concentration (SSC) is a crucial riverine parameter in terms that it can be utilized for analyzing sediment transport, stability assessment of river and structure and so on. However, in case of domestic, sediment discharge data are not enough because of using conventional sediment samplers. This study aimed at developing a practical technique for estimating suspended sediment concentration in high spatial and temporal resolution by building relationship between acoustic backscatter (or SNR) from H-ADCP with actually observed data using LISST-100X. In this regard, a dedicated correction algorithm was proposed particularly for the adapted H-ADCP (SonTek SL-3000). Then, a SNR-SSC relation was built based upon a real-scale field experiment, where both H-ADCP and LISST-100X were concurrently operated to observe SNR and SSC, respectively. The coefficient of determination for the developed regression equation of SNR-SSC relation was around 0.85~0.88, thereby the relation could be evaluated to be highly correlated. The result of this study might be potentially applied for real-time and simultaneous observation of SSC when H-ADCP could be applied.