• 제목/요약/키워드: Building energy situation

검색결과 95건 처리시간 0.025초

부산시 환경기초시설 내 태양에너지(태양광/태양열) 이용 시설 설치 타당성 확인 (Feasibility Identification on Establishment of Solar Energy (Photovoltaic and Solar Heating) at the Environmental Basic Facilities in Busan)

  • 김지원;최현호;김삼열;박재홍;김동현;이대선;박상태;김규식;유재철
    • 한국기후변화학회지
    • /
    • 제6권2호
    • /
    • pp.73-85
    • /
    • 2015
  • With 12 environmental basic facilities (EBF) in Busan, each business place's present situation of the operation of new and renewable energy as well as the feasibility to establish additional systems of utilizing solar energy (photovoltaic power generation system [PPGS] and solar heating system [SHS]) were investigated. Currently, with the environmental basic facilities, the new and renewable energies (such as, waste heat, biogas, PPGS, SHS, and small hydro power) can produce 195 GWh per year as electric power unit. Among the energy sources, except waste heat, biogas (154 GWh/yr) appears as the highest. Next, PPGS is the second most widely used system and produces 5,560 MWh/yr at 11 business places. Through a field survey, it appears that 19 business places of total 27 places at 12 EBFs have good locational conditions and they need an introduction of PPGS. Through it, it is investigated that it would be possible to produce 5,311 MWh/yr and to reduce $2,348tCO_2/yr$. And, it is identified that SHS can be additionally introduced in only 4 EBFs. This can reduce energy cost as much as one ten million won/yr and green-house gas as much as $28tCO_2/yr$. A cost-benefic analysis shows that the use of governmental support or private investment can be the most efficient way, when PPGS and SHS are introduced in EBFs.

전기다리미의 발화원인 판정에 관한 현상학적 고찰 (A Phenomenological Review on the Decision on the Cause of Ignition of Electric Iron)

  • 문용수;공하성;이종화
    • 대한안전경영과학회지
    • /
    • 제11권1호
    • /
    • pp.43-49
    • /
    • 2009
  • This study set three kinds of situation and observed the various states such as carbonization by experimenting damages by fire of electric iron. The results of this study are as follows: The fire did not occurred when the unpowered iron over mattress and cotton shirts was com busted completely by external flame because the temperature of surface of soleplate and mattress did not reach the minimum ignition energy and when the powered electric iron over mattress and cotton shirts was left for an hour with its temperature dial set to high because the temperature of combustibles did not reach the minimum ignition energy. The fire occurred when the electric iron in which the outer box, bi-metal switch, and temperature fuse were removed over mattress and cotton shirts was powered by through heater terminal, and then the electric iron, mattress, and cotton shirts were combusted by the fallen combustibles because the temperature of combustibles reached to the minimum ignition energy with the help of active transfer of heat.

산업부산물인 바이오매스 플라이애시를 활용한 경화체의 물리적 특성 (Physical Properties of Matrix using Biomass Fly Ash an Industrial By-product)

  • 김대연;조은석;이상수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 추계 학술논문 발표대회
    • /
    • pp.21-22
    • /
    • 2019
  • In order to prevent global warming according to fossil fuel use, countries around the world are making efforts through the Kyoto Protocol and the Paris Climate Change Convention. In addition, in order to prepare for high oil prices, researches such as the development of various renewable energy are being conducted. At present, the domestic production rate of energy sources in Korea is low at 18.1%, and power plants using forest biomass are being constructed to meet the domestic situation where 63% of the land is a forest. In 2015, the global production of wood pellets, a raw material for wood-based biomass power generation, was 28 million tons, up 7.7% from 2014, and has increased tenfold over the last decade. This is a result of increased demand for biomass. Korea is also increasing every year. However, biomass fly ash, an industrial by-product generated by biomass energy generation, is now being disposed of entirely, and there is little research to utilize it. Therefore, this paper will use biomass fly ash, an industrial by-product, which is currently being discarded due to a lack of separate treatment methods, as an admixture concept to contribute to solving environmental problems, developing new admixtures, improving quality, and seeking recycling plans.

  • PDF

건물 재실자의 미생물 안전을 위한 면역건물 기술의 에너지 사용 연구 (A study on the disinfection performance of indoor microorganism using energy consumption analysis for indoor bio-safety)

  • 최상곤
    • 대한안전경영과학회지
    • /
    • 제11권4호
    • /
    • pp.111-118
    • /
    • 2009
  • In this study the real situation of apartment house in seoul is reproduced with multi-zone modeling program CONTAM2.4. This model include disinfection system which is consist of dilution, filtration, UVGI(ultra violet germicidal irradiation). It's energy consumption was also analyzed through the linked model of CONTAM and TRNSYS according to the combination of components. The comparison of total energy consumption through energy analysis revealed that adjusting the air change rate of the UVGI air sterilizer to maintain the same indoor microbe removal capability was more advantageous in terms of energy consumption.

미시적 재료모델을 사용한 원전 격납건물 벽체 요소의 구조거동 분석 (On the investigation of structural behaviour of nuclear containment building wall element using microscopic material model)

  • 이상진;이홍표;서정문
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2000년도 가을 학술발표회논문집
    • /
    • pp.217-221
    • /
    • 2000
  • Nonlinear stress analysis of nuclear containment building wall element is carried out using microscopic material model. The present study mainly focuses on the finite element analysis of the nuclear containment building wall element under biaxial tensile stresses and it evaluates the perfomance of adopted microscopic material model in the membrane energy dominant situation. From the numerical analysis, the adopted material model peforms well and has a good agreement with experiment result. Finally, the result of present study can be severed as a benchmark test when concrete material model is in need of evaluation.

  • PDF

공동주택의 입면 변화에 따른 일조 현황 분석 - Skyline 변화를 중심으로 - (Analysis of the Daylight Condition on Facade Variation in Apartment Housing)

  • 이덕형;최창호;이현우
    • 한국태양에너지학회 논문집
    • /
    • 제26권2호
    • /
    • pp.79-86
    • /
    • 2006
  • As a factor of housing environment, right of light became a subject of discussion as a social issue. Cases on the right of light in properties have been increased. Also many interests in the scape of the city have been increased. This study aims to show the possibility of variation of the shape of the apartment buildings considering the right of light. Reflecting this recent situation, we are setting up the night illumination and constructing a building which acts as Land Mark like the Jong-Ro Tower. And In case of the apartment building, various forms are deviated from an existing standardized form and skyline Existing studies on the sunshine of apartment buildings have dealt with just a standardized apartment building form. So this study analyzed a recently increasing interest for right of light and the changes of sunshine environment of apartment buildings having various forms of skyline.

Extracting parameters of TMD and primary structure from the combined system responses

  • Wang, Jer-Fu;Lin, Chi-Chang
    • Smart Structures and Systems
    • /
    • 제16권5호
    • /
    • pp.937-960
    • /
    • 2015
  • Tuned mass dampers (TMDs) have been a prevalent vibration control device for suppressing excessive vibration because of environmental loadings in contemporary tall buildings since the mid-1970s. A TMD must be tuned to the natural frequency of the primary structure to be effective. In practice, a TMD may be assembled in situ, simultaneously with the building construction. In such a situation, the respective dynamic properties of the TMD device and building cannot be identified to determine the tuning status of the TMD. For this purpose, a methodology was developed to obtain the parameters of the TMD and primary building on the basis of the eigenparameters of any two complex modes of the combined building-TMD system. The theory was derived in state-space to characterize the nonclassical damping feature of the system, and combined with a system identification technique to obtain the system eigenparameters using the acceleration measurements. The proposed procedure was first demonstrated using a numerical verification and then applied to real, experimental data of a large-scale building-TMD system. The results showed that the procedure is capable of identifying the respective parameters of the TMD and primary structure and is applicable in real implementations by using only the acceleration response measurements of the TMD and its located floor.

계층분석법을 이용한 녹색건축 인증제도 평가항목의 중요도 분석 -공동주택 인증기준을 중심으로- (Analyzing Weights of Certification Assessment Criteria on the G-SEED System Using the AHP Method -Focused on Certification Standards for Apartment Buildings-)

  • 최여진
    • KIEAE Journal
    • /
    • 제13권6호
    • /
    • pp.113-120
    • /
    • 2013
  • Many countries over the world have taken many discussions and endeavors on environmental improvements of energy savings and greenhouse gas emission reductions for solving global climate change problems. In Korea, pre-considerations of environment-conscious factors in buildings have been taken to be critical with new constructions and renovation markets. In this situation, the Korean Green Building Certification(KGBC) system to induce the diffusion of sustainable buildings was introduced in 2002 and developed as an improved version of the G-SEED(Green Standard for Energy and Environmental Design) system in 2013 after major revisions. This research examines the importance of assessment criteria on apartment buildings to certify green buildings using the AHP(Analytic Hierarchy Process) method and suggests a new direction on certification assessment standards from the AHP result. In order to apply the AHP method, the survey via e-mail was conducted to design staffs in domestic architectural firms. As a result, assessment criteria such as ecological environment, indoor environment, and energy & environment pollution among 7 main ones proved to be important on assessing the G-SEED system for apartment buildings, while criteria such as land use & transportation, material & resource, water circulation management, maintenance management did relatively unimportant.

시험공간에 대한 난방부하 실증실험 및 계산 (Verification Experiment and Calculation of Heating Load for a Test Space)

  • 현석균;홍희기;유호선
    • 설비공학논문집
    • /
    • 제14권2호
    • /
    • pp.153-160
    • /
    • 2002
  • As a way to assess the reliability of programs for building energy analysis, verification experiment and calculation of heating load are simultaneously conducted for a well-defined test space. Experimental conditions are carefully set to minimize uncertainties associated with radiation heating, air change, infiltration, and room-to-room interaction. Dyna- mic load calculations using TRNSYS, which are performed for two different computation domains, rely on the energy rate control that represents inherent load characteristics of a space. The predicted instantaneous heating load favorably simulates the overall behavior the measured one, though the latter fluctuates much more rapidly than the former Comparison of the accumulative load between the experiment and calculations shows a close agreement within an engineering tolerance, regardless of the computation model. It is deduced from such findings that the present experimental results along with weather information can serve as a set of reference data for validating load calculation softwares from the users'standpoint. In order to enhance the completeness of this work, a complementary study on the cooling load for the same test space is highly recommended.

난방을 비롯한 공기조화의 자연조절 방식과 현대적 응용에 관한 고찰 (A Study on the Passive Principle and its Practical Application of Air-conditioning System)

  • 박순관
    • 한국건축시공학회지
    • /
    • 제4권2호
    • /
    • pp.105-112
    • /
    • 2004
  • The objective of this study is to observe today's situation and direction in relation with the natural air-conditioning and heating system to expand the architectural utilization of natural management for human comfort and energy conservation in architectural design. Also this study to provide the fundamental knowledge and. design-techniques on environment-friendly architecture in connection with 'natural idea in architecture'. In accordance with this intention, this thesis is composed of the following contents : 1) to understand the fundermental concepts about natural air-conditioning and heating system, 2) to review the traditional characteristics in Korean and Southeast Asian architecture related to natural air-conditioning and heating system, 3) to examine modern design-techniques in relation with natural air-conditioning and heating system in the selected area, 4) to attempt to synthesize the whole situation. Environment-friendly architecture using natural ideas and design-techniques in architecture is very important architectural aspect in a current architecture, also for the future. In spite of general considerations, it is expected that this study is use to understand the principle and practical application of natural air-conditioning and heating system in architectural design.