• Title/Summary/Keyword: Building energy rating system

Search Result 89, Processing Time 0.036 seconds

A study on the Insulation Performance of the SuperWindow considering the Evaluation of Building Energy Rating (건물에너지효율등급 적용에 따른 초단열 슈퍼윈도우 열성능 평가)

  • Jang, Cheol-Yong;Kim, Chi-Hoon;Ahn, Byung-Lip;Hong, Won-Hwa
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.1
    • /
    • pp.1-6
    • /
    • 2010
  • Generally, the building's windows and ventilation for the purpose of mining and the vista and windows by emotional engineering design area is a growing trend.In addition, the building regulation U-value limitation of window is $3.3W/m^2{\cdot}K$ in southern regions, while U-value limitation of wall is $0.35{\sim}0.58W/m^2{\cdot}K$. It means that the energy loss through windows is six times more than it through wall. Therefore, the purpose of this study is to evaluate the environmental performance of the super window system by verification experiment. The results of this study are as follows; 1) The insulation performance of super window system is $1.44\;W/m^2^{\circ}C$ 2) Super Window compared to a normal window reduce heating energy requirements have been 5.3% 3) Compared to a normal window, Super window savings rate was 4.1% lower 4) Building energy efficiency rating was up to 1 rating from 2 rating.

The Building Energy Efficiency Rating Evaluation of Apartment depending on SC and Window area ratio (차폐계수와 창면적비에 따른 공동주택의 건물에너지효율등급 평가)

  • Jang, Cheol-Yong;Han, Hye-Sim;Lee, Jin-Sook
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.5
    • /
    • pp.38-43
    • /
    • 2010
  • Enhancement of exterior's insulation performance like wall or window etc. is general way for building's energy efficient and thermal performance. But exterior's opening plan is important for minimizing the energy consumption and heat loss. In this paper, energy saving rate will be analyzed and compared considering the window area's rate and window's SC(Shading Coefficient) in a apartment with Building Energy Efficiency Rating System's evaluation tool. In the process of evaluation, energy saving rate is measured at each stage of the window area's rate from 20% to 60% every 10% term and the shading coefficient value from 1.0 to 0.6. As a result of this research, energy saving evaluation could not be measured exactly with existing evaluation tool. Accord this research, Building Energy Rating System's evaluation range is needed to be broaden for exact evaluation of energy saving rate.

A Study on Training of Specialist to prepare Mandatory Building Energy Efficiency Rating Ssytem (건축물 에너지효율등급 인증제도 의무화 대비 전문인력 양성에 대한 연구)

  • Jang, Cheol-Yong;Han, Hye-Sim;Lee, Na-Eun
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.138-143
    • /
    • 2011
  • Until now, measures for energy saving in buildings have been tried. Because particularly the role of buildings area is very important for implementing national greenhouse gas reduction targets and Green growth. But, lack of business linkages between each sector or the interest and participation of private sector are not enough. In addition, relevant personnel to do had not been systematized. It is expected that certification services will be increased according to the activation of Building Energy Efficiency Rating System and expansion of the target buildings so Government must be prepared to expand of certification system by training Professional staff. In this study, the basic data for the introduction of obligation of Building Energy Efficiency Rating System is suggested through analysis of the operating and laws system of Building Energy Efficiency Rating System along with efforts of Government for diffusion low energy buildings.

  • PDF

Correlation Analysis Between Fenestration Energy Consumption Efficiency Rating System and Building Energy Consumption (창호 에너지 소비 효율 등급제와 건물 에너지 소비의 상관관계 분석)

  • Kwak, Hee-Jeong;Jang, Hyang-In;Lee, Hyun-Soo;Eom, Jae-Yong;Suh, Seung-Jik
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.6
    • /
    • pp.338-345
    • /
    • 2013
  • The purpose of this study is to analyze the correlation between the 'Fenestration Energy Consumption Efficiency Rating System' (hereafter referred to as FECERS) and building energy consumption. 'EnergyPlus' was used for the calculation of energy consumption in apartments and office buildings, according to FECERS's rating and SHGC. The result indicates that the FECERS has high correlation with apartments, but has low correlation with office buildings. Also, it indicates that office buildings have a large impact from SHGC, which is not reflected in the FECERS. Consequently, the FECERS needs to be improved, by adding optical properties to assessment items. Additional study is required to establish the fenestration rating system, which, on the basis of this work, has high relevance to building energy consumption.

Comparative analysis of Korean and foreign energy performance assessment methods for residential buildings (국내외 주거용 건물의 에너지성능 평가방법 비교분석)

  • Song, Seung-Yeoung;Koo, Bo-Kyoung;Lee, Beung-In;Song, Jin-Hee;Kim, Yeon-Hee
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.191-198
    • /
    • 2009
  • Many Countries are making nationwide efforts to reduce the energy consumption which causes greenhouse gas emissions and global warming problems. Energy performance assessments and certification systems have been in force to save energy consumption of residential buildings, and are anticipated to have strong effects through the systems. Korean Building Energy Efficiency Rating System is in its early stages and is considered that the additional upgrade is needed for the accurate assessment. Thus, in this study, the assessment methods of the Building Energy Efficiency Rating System of Korea and the SAP2005 of UK were compared and energy requirements of an actual residential building were calculated with two assessment methods, respectively. The strengths and shortcomings of two systems were analyzed and a way of improving Korean system was suggested.

  • PDF

Impact of Green Building Rating System on an Apartment Housing Price (친환경인증제도가 주택가격에 미치는 영향 분석)

  • Shon, Young Jin;Lee, Sang Hyo;Kim, Jae Jun
    • KIEAE Journal
    • /
    • v.10 no.4
    • /
    • pp.131-136
    • /
    • 2010
  • Because energy consumption of the construction part is very high, there is a growing need to introduce environment-friendly buildings. Therefore Green Building Rating System is enacted in Korea. Though environment-friendly factors such as green area affect the apartment housing price, there's no saying whether Green Building Rating System directly affect the apartment housing price. The purpose of this paper is to estimate the impact of Green Building Rating System on an apartment housing price. The analysis result demonstrated that Green Building Rating System don't affect the apartment housing price. This result means that there is a problem with the effectiveness of Green Building Rating System. The government ought to institute incentive program to ctivate the market of environment-friendly building.

A Framework of Building Knowledge Representation for Sustainability Rating in BIM

  • Shahaboddin Hashemi Toroghi;Tang-Hung. Nguyen;Jin-Lee. Kim
    • International conference on construction engineering and project management
    • /
    • 2013.01a
    • /
    • pp.437-443
    • /
    • 2013
  • Recently, sustainable building design, a growing field within architectural design, has been emerged in the construction industry as the practice of designing, constructing, and operating facilities in such a manner that their environmental impact, which has become a great concern of construction professionals, can be minimized. A number of different green rating systems have been developed to help assess that a building project is designed and built using strategies intended to minimize or eliminate its impact on the environment. In the United States, the widely accepted national standards for sustainable building design are known as the LEED (Leadership in Energy and Environmental Design) Green Building Rating System. The assessment of sustainability using the LEED green rating system is a challenging and time-consuming work due to its complicated process. In effect, the LEED green rating system awards points for satisfying specified green building criteria into five major categories: sustainable sites, water efficiency, energy and atmosphere, materials and resources, and indoor environmental quality; and sustainability of a project is rated by accumulating scores (100 points maximum) from these five major categories. The sustainability rating process could be accelerated and facilitated by using computer technology such as BIM (Building Information Modeling), an innovative new approach to building design, engineering, and construction management that has been widely used in the construction industry. BIM is defined as a model-based technology linked with a database of project information, which can be accessed, manipulated, and retrieved for construction estimating, scheduling, project management, as well as sustainability rating. This paper will present a framework representing the building knowledge contained in the LEED green building criteria. The proposed building knowledge framework will be implemented into a BIM platform (e.g. Autodesk Revit Architecture) in which sustainability rating of a building design can be automatically performed. The development of the automated sustainability rating system and the results of its implementation will be discussed.

  • PDF

A Study of the evaluation of Building Energy Rating depending on region according to the Insulation Performance of the Super window (슈퍼윈도우 열성능에 따른 지역별 건물에너지 효율등급에 관한 연구)

  • Jang, Cheol-Yong;Ahn, Byung-Lip;Kim, Chi-Hoon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.211-215
    • /
    • 2009
  • As entering in the time of high oil price, seriousness of an energy is on the rise and the importance of energy is growing. Especially, building energy occupying 24% of total demand of energy is expected to be possible to reduce energy demand more than other section. To reduce the building energy consumption, this study analyzes function and thermal performance of Super window by heat experimental apparatus. Super window is a 2-track low-e glazing window for high insulation efficiency. By applying the results of this experiment to building energy efficiency rating tool, this study compares energy efficiency rates depending on a region.-Jeju, South, Central. And it shows how much does Super window reduce Building energy consumption.

  • PDF

The Energy Analysis and Evaluation of the NEO-Hanok

  • Han, Sang Hee;Park, So Yeon;Park, Hyo Soon
    • KIEAE Journal
    • /
    • v.14 no.2
    • /
    • pp.77-86
    • /
    • 2014
  • Plenty of efforts have been made in the traditional architecture of Korea, Hanok, to develop various elements such as restoration, the introduction of new design, and energy-saving while systemic setups on standard and evaluation of eco-friendly energy design of Hanok are lacking. If we evaluate energy performance based on current standards without reflecting unique features of Hanok on the system, Hanok will be included in the very low grade among the residential buildings being included in the approval system of eco-friendly architecture or the unique features will be modified and the burden of increased construction cost. Therefore, this study is to prepare the basic reference for the introductory evaluation system by evaluating the energy performance level of NEO-Hanok based on the current building energy rating system. The result for NEO-Hanok based on the building energy rating system, we propose the rating standard with scorecard elements of NEO-Hanok by considering the necessity of identity and standard for NEO-Hanok. As a result of infiltration test to check the tightness, it was measured as 10.81 times/h (50 ACH). As we switch from the main insulation for the wall from the glass wool 64k(0.035W/mk) to rigid polyurethane foam first class first unit (0.024W/mk), the result was slightly increased from the first demand quantity rating yield $249.8kWh/m^2{\cdot}yr$ to $235.0kWh/m^2{\cdot}yr$. Current certificate system is focused more on the heating load than the cooling load, it is disadvantageous for Hanok, which has less cooling energy consumption in summer. The rating result from the target building study is level 4.

Study on High Performance Building Envelope for raising Building Energy Rating (건물에너지효율등급향상을 위한 고효율 건물외피 성능 연구)

  • Hyun, Jong-Hun;Hong, Sung-Hee;Park, Hyo-Soon;Choi, Moo-Hyuck
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.801-806
    • /
    • 2008
  • The best plan is that the insulation performance should be improved because the insulation and airtight of building envelopes have an effect on the energy consumption basically. New insulation materials, which have the high performance and are above insulation standard, have been developed steadily. Because there are not studies on the building energy rating system and economic evaluation considering new insulation materials, these matters should be studied. In result alternatives, which applied 6 high performance material each, influence, reduce the annual heating energy and raise the building energy rating. Applying the vacuum insulation material(Case1,2) and vacuum or triple glazing can retrieves the investment with $120 and $$140{\sim}150$ per barrel each.

  • PDF