• 제목/요약/키워드: Bubble-particle interaction

검색결과 13건 처리시간 0.021초

기포를 이용한 미세 부유 폴리에틸렌 입자 포획에 대한 연구 (Study of capturing micro-sized floating polyethylene particles using a bubble)

  • 최진용;박형민
    • 한국가시화정보학회지
    • /
    • 제20권3호
    • /
    • pp.67-73
    • /
    • 2022
  • Underwater environmental pollution caused by microplastic particles is considered to be one of the most serious problems in many oceans and countries nearby. Previous academic studies or field technologies tried to remove the micro-sized particles are often energy-consuming and costly, so it is hard to be employed for the actual uses. In this study, the mechanism of removal of micro-sized polyethylene spheres (size in order of 100㎛) using a rising bubble is experimentally investigated. It is found that the particles are either affected by bubble wake, thus translocated close to the water surface, or pushed far away by the surrounding fluid flow, depending on their initial position relative to the bubble. By scrutinizing the visualized behaviors of bubble-particle interaction, we draw the governing parameter, i.e., the polar angle between the particle and the bubble, to determine the effective capturing of the particles with a rising bubble.

입자와 주위유체와의 상호작용에 관한 연구 (A Study on the Interaction between Particles and Surrounding Fluid)

  • 최해만
    • 설비공학논문집
    • /
    • 제14권2호
    • /
    • pp.108-115
    • /
    • 2002
  • The fundamental mechanism of a dispersed two-phase flow was investigated. Experiments were carried out to understand how the particles behaves under the influence of the particle size, shape, metamorphoses (bubble) and buoyancy of a single particle which is ascending from the standstill water. Two CCD cameras were employed for image processing of the behavior of the particles and the surrounding flow, which was interpreted with the technique of correlation PIV (Particle Image Velocimetry) and PTV (Particle Tracking Veloci- metry), respectively The experimental results showed that the large density difference bet- ween a particle and water caused high relative velocity and induced zigzag motion of the particle. Furthermore, the turbulence intensity of a bubble was about twice the case of the spherical solid particle of similar diameter.

고점성 액체 내부에서의 다중 노즐 버블링에 의한 유동특성에 대한 실험적 연구 (An Experimental Study on the Flow Characteristics in Highly Viscous Liquid by Multi-Nozzle Bubbling)

  • 김현동;류승규;김경천
    • 대한기계학회논문집B
    • /
    • 제31권2호
    • /
    • pp.195-201
    • /
    • 2007
  • A visualization study of flow characteristics in a mixer using multi-nozzle bubbling was performed. The mixer is filed with liquid glycerin (dynamic viscosity = $1000mPa{\cdot}s\;at\;25^{\circ}C$) and convective mixing is induced by air bubbles generated from 9 orifices installed on the bottom of the mixer. To visualize the flow field, PIV (Particle Image Velocimetry) system consisting of 532nm Nd:YAG laser, $2k{\times}2k$ CCD camera and synchronizer is adopted. The bubbles generated with uniform size and frequency form bubble stream and bubble streams rise vertically without interaction between bubble streams. Mixing efficiency is affected by the height of bubbler and the effective height of bubbler is 20nm from the bottom of the mixer.

고점성 유체 내부에서의 다상유동장 가시화 및 PIV 측정 (Flow Visualization and PIV Measurement of Multiphase Flow in Highty Viscous Liquid)

  • 김현동;류승규;김경천
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2006년도 추계학술대회 논문집
    • /
    • pp.48-54
    • /
    • 2006
  • A visualization study of flow characteristics in a mixer using multi-nozzle bubbling was performed. The mixer is filled with liquid glycerin (dynamic viscosity = $1000mPa{\cdot}$ s at $25^{\circ}C$) and convective mixing is induced by air bubbles generated from 9 orifices installed on the bottom of the mixer. To visualize the flow field, PIV (Particle Image Velocimetry) system consisting of 532nm Nd:YAG laser, $2k\times2k$ CCD camera and synchronizer is adopted. The bubbles generated with uniform size and frequency form bubble stream, and bubble streams rise vertically without interaction between bubble streams. Mixing efficiency is affected by the height of bubbler and the effective height of bubbler is 20mm from the bottom of the mixer.

  • PDF

총설: 액체 중에서 상승하는 기포의 크기, 형상 및 속도 (A Review on Size, Shape and Velocity of a Bubble Rising in Liquid)

  • 박성훈
    • 한국입자에어로졸학회지
    • /
    • 제13권1호
    • /
    • pp.1-10
    • /
    • 2017
  • 본 총설에서는 액체층을 통과하는 기포의 크기, 형상, 상승속도를 결정하기 위한 이론들을 살펴보았다. 액체의 물리적 특성과 기포의 유량으로부터 기포의 크기, 형상, 상승속도를 체계적으로 계산하는 여러 가지 이론식 및 모수식들을 살펴보고, 각각의 장단점을 정리하였다. 이 분야에서 발표된 초기 저작들에서는 주로 반복계산을 통해 기포의 형상과 상승속도를 결정하는 기법들이 사용되었으나, 최근에 발표된 논문들에서는 간단한 모수식을 통해 기포의 형상과 상승속도를 반복계산 없이 쉽게 구하는 기법들이 제시되고 있다. 이러한 기법들은 매우 다양한 물리적 특성을 가지는 실험결과들과의 비교에서도 우수성을 보여주고 있어, 관련 분야의 연구에 매우 유용한 도구로 사용할 수 있을 것으로 보인다.

사각탱크 내부의 기포구동유동에 대한 동특성 연구 (Dynamic Analysis of Bubble-Driven Liquid Flows in a Rectangular Tank)

  • 김상문;이승재;김현동;김종욱;김경천
    • 한국가시화정보학회지
    • /
    • 제8권1호
    • /
    • pp.31-38
    • /
    • 2010
  • An experimental study to evaluate dynamic structures of flow and turbulence characteristics in bubble-driven liquid flow in a rectangular tank with a varying flow rate of compressed air is conducted. Liquid flow fields are measured by time-resolved particle image velocimetry (PIV) with fluorescent tracer particles to eliminate diffused reflections, and by an image intensifier to acquire enhanced clean particle images. Instantaneous vector fields are investigated by using the two frame cross-correlation function and bad vectors are eliminated by magnitude difference technique. By proper orthogonal decomposition (POD) analysis, the energy distributions of spatial and temporal modes are acquired. When Reynolds number increases, bubble-induced turbulent motion becomes dominant rather than the recirculating flow near the side wall. The total kinetic energy transferred to the liquid from the rising bubbles shows a nonlinear relation regarding the energy input because of the interaction between bubbles and free surface.

Time-resolved PIV와 POD기법을 이용한 단일노즐 버블링 유동 특성에 관한 연구 (Characteristics of Bubble-driven Flow by Using Time-resolved PIV and POD Technique)

  • 이승재;김종욱;김현동;김경천
    • 한국가시화정보학회지
    • /
    • 제6권1호
    • /
    • pp.41-46
    • /
    • 2008
  • In this paper, the recirculation flow motion and mixing characteristics driven by air bubble stream in a rectangular water tank is studied. The time-resolved PIV technique is adopted for the quantitative visualization and analysis. 488 nm Ar-ion CW laser is used for illumination and orange fluorescent ($\lambda_{ex}=540nm,\;\lambda_{em}=560nm$) particle images are acquired by a PCO 10bit high-speed CCD camera (1280$\times$1024). To obtain clean particle images, 545 nm long pass optical filter and an image intensifier are employed and the flow rates of compressed air is 3 l/min at 0.5 MPa. The recirculation and mixing flow field is further investigated by time-resolved POD analysis technique. It is observed that the large scale recirculation resulting from the interaction between rising bubble stream and side wall is the most dominant flow structure and there are small scale vortex structures moving along with large scale recirculation flow. It is also verified that the sum of 20 modes of velocity field has about 67.4% of total turbulent energy.

주입 위치에 따른 기포와 상변화물질의 유동 상호 작용에 관한 연구 (Study on Flow Interaction between Bubble and Phase Change Material according to Injection Location)

  • 김민혁;지윤영;손동기;고한서
    • 한국가시화정보학회지
    • /
    • 제21권3호
    • /
    • pp.75-84
    • /
    • 2023
  • In this study, we conducted analysis of bubble dynamics and flow of liquid phase change material(PCM) using shadowgraphy and particle image velocimetry(PIV). Characteristics of internal flow varied depending on locations of injection when solid PCM was liquefied from heated vertical wall. When bubbles rose immediately, they exhibited elliptical shape and zigzag trajectory. In contrast, when bubbles rose after merging at the bottom of solid PCM, with equivalent diameter for the inter-wall distance of 0.64 or greater, they showed a jellyfish shape and strong rocking behavior. It was observed by the PIV that the small ellipse bubbles made most strong flow inside the liquid PCM. Furthermore, the flow velocity was highest in the case of front injection, as the directions of temperature gradients and bubble-driven flow were aligned. The results underscore the significant influence of injection location on various characteristics, including bubble size, shape, rising path of bubbles, and internal flow.

An experimental study on pool sloshing behavior with solid particles

  • Cheng, Songbai;Li, Shuo;Li, Kejia;Zhang, Ting
    • Nuclear Engineering and Technology
    • /
    • 제51권1호
    • /
    • pp.73-83
    • /
    • 2019
  • It is important to clarify the mechanisms of molten-fuel-pool sloshing behavior that might be encountered during a core disruptive accident of sodium-cooled fast reactors. In this study, motivated by acquiring some evidence for understanding the characteristics of this behavior at more realistic conditions, a number of experiments are newly performed by injecting nitrogen gas into a water pool with the accumulation of solid particles. To achieve comprehensive understanding, various parameters including particle bed height, particle size, density, shape, gas pressure along with the gas-injection duration, were employed. It is found that due to the different interaction mechanisms between solid particles and the gas bubble injected, three kinds of regimes, termed respectively as the bubble-impulsion dominant regime, the transitional regime and the bed-inertia dominant regime, could be identified. The performed analyses also suggest that under present conditions, all our experimental parameters employed can have noticeable impact on the regime transition and resultant sloshing intensity (e.g. maximum elevation of water level at pool peripheries). Knowledge and fundamental data from this work will be used for the future verifications of fast reactor severe accident codes in China.

Simulation on mass transfer at immiscible liquid interface entrained by single bubble using particle method

  • Dong, Chunhui;Guo, Kailun;Cai, Qinghang;Chen, Ronghua;Tian, Wenxi;Qiu, Suizheng;Su, G.H.
    • Nuclear Engineering and Technology
    • /
    • 제52권6호
    • /
    • pp.1172-1179
    • /
    • 2020
  • As a Lagrangian particle method, Moving Particle Semi-implicit (MPS) method has great capability to capture interface/surface. In recent years, the multiphase flow simulation using MPS method has become one of the important directions of its developments. In this study, some key methods for multiphase flow have been introduced. The interface tension model in multiphase flow is modified to maintain the smooth of the interface and suitable for the three-phase flow. The mass transfer at immiscible liquid interface entrained by single bubble which could occur in Molten Core-Concrete Interaction (MCCI) has been investigated using this particle method. With the increase of bubble size, the height of entrainment column also increases, but the time of film rupture is slightly different. With the increase of density ratio between the two liquids, the height of entrained column decreases significantly due to the decreasing buoyancy of the denser liquid in the lighter liquid. In addition, the larger the interface tension coefficient is, the more rapidly the entrained denser liquid falls. This study validates that the MPS method has shown great performance for multiphase flow simulation. Besides, the influence of physical parameters on the mass transfer at immiscible interface has also been investigated in this study.