• 제목/요약/키워드: Bridgeless rectifier

검색결과 31건 처리시간 0.021초

경계전류모드를 사용한 Adapter용 브리지리스 정류회로의 성능 개선 (Performance Improvement of Bridgeless Rectifier Circuit for Adapter Using Boundary Current Mode)

  • 유호원;임승범;정연호;이준영;홍순찬
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.172-174
    • /
    • 2007
  • The AC-DC Adapter has been widely used in Mobile Phones, Note Book PC, LCD monitors, and portable electronic products. Recently, high-power-density Adapter was developed. This adapter increases power factor using a bridge diode rectifier and PFC, however, there are weak points that improving efficiency is limited. In the bridgeless rectifier circuit proposed in this paper, there is no PFC, however, the power factor and efficiency are improved by BCM and ZCS operations.

  • PDF

무선전력전송 시스템의 공진주파수 변동을 보상하기 위한 Bridgeless 정류기 동작 분석 (Performance Analysis of Bridgeless Rectifier for Inductive Power Transfer System to Compensate Resonance Frequency Variation)

  • 손원진;이재광;안상준;변종은;이병국
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 추계학술대회
    • /
    • pp.129-130
    • /
    • 2017
  • 본 논문에서는 자기유도방식 무선충전 시스템의 송 수신 패드 위치 변화에 따른 공진주파수 변동을 보상하기 위한 bridgeless 정류기 동작에 대해 분석한다. Bridgeless 정류기의 스위칭 시점 및 duty 변화에 따른 공진네트워크 입력임피던스의 위상 변화를 수식적으로 분석하고, 시뮬레이션을 통하여 분석 결과를 검증한다.

  • PDF

무선전력전송 시스템의 Bridgeless 정류기 성능 향상을 위한 스위칭 주파수 변조 기법 (Switching Frequency Modulation Technique to Improve Performance of Bridgeless Rectifier for Wireless Power Transfer System)

  • 손원진;이재한;변종은;이병국
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 전력전자학술대회
    • /
    • pp.42-44
    • /
    • 2018
  • 본 논문에서는 Bridgeless 정류기가 적용된 무선전력전송(Inductive Power System, IPT) 시스템의 성능 향상을 위한 스위칭 주파수의 변조 기법에 대해 제안한다. Bridgeless 정류기의 기존 제어 방식과 제안하는 제어 방식의 동작을 비교하고 3.3kW급 무선전력전송 시스템에 대한 시뮬레이션을 통해 제안하는 제어 방식에 대한 동작을 검증한다. 제안하는 제어 방식의 성능을 검증하기 위해 기존 제어 방식과의 손실을 비교 분석한다.

  • PDF

Single-Phase Bridgeless Zeta PFC Converter with Reduced Conduction Losses

  • Khan, Shakil Ahamed;Rahim, Nasrudin Abd.;Bakar, Ab Halim Abu;Kwang, Tan Chia
    • Journal of Power Electronics
    • /
    • 제15권2호
    • /
    • pp.356-365
    • /
    • 2015
  • This paper presents a new single phase front-end ac-dc bridgeless power factor correction (PFC) rectifier topology. The proposed converter achieves a high efficiency over a wide range of input and output voltages, a high power factor, low line current harmonics and both step up and step down voltage conversions. This topology is based on a non-inverting buck-boost (Zeta) converter. In this approach, the input diode bridge is removed and a maximum of one diode conducts in a complete switching period. This reduces the conduction losses and the thermal stresses on the switches when compare to existing PFC topologies. Inherent power factor correction is achieved by operating the converter in the discontinuous conduction mode (DCM) which leads to a simplified control circuit. The characteristics of the proposed design, principles of operation, steady state operation analysis, and control structure are described in this paper. An experimental prototype has been built to demonstrate the feasibility of the new converter. Simulation and experimental results are provided to verify the improved power quality at the AC mains and the lower conduction losses of the converter.

토템폴 브릿지리스 PFC의 내부 손실 분석과 병렬 스위치를 사용한 효율 개선에 관한 연구 (A Study on Internal Loss Analysis of Totem Pole Bridgeless PFC and Efficiency Improvement using Parallel Switch)

  • 유정상;길용만;유승협;안태영
    • 반도체디스플레이기술학회지
    • /
    • 제19권4호
    • /
    • pp.22-27
    • /
    • 2020
  • In this paper, a generalized efficiency equation was proposed to estimate the internal loss of the SMPS (switched-mode power supply) with 3 variables. The first variable was an internal loss not related to the load current such as auxiliary power, the second was a loss proportional to the current such as diode loss, and the third was a loss proportional to square of the current such as conduction loss. Especially, theoretical internal losses of the totem pole bridgeless PFC which is widely used for high efficiency SMPS were expressed as output function to compare generalized efficiency equation. In addition, in order to reduce the conduction loss of the switch, when a multiple switch were paralleled, the correlation with the efficiency was analyzed and shown as a graph. In order to confirm the degree of the parallel switch structure on the efficiency improvement, a 2kW class totem pole bridgeless PFC was constructed and the effectiveness of the analysis was confirmed by comparing the generalized efficiency equation and theoretical loss analysis results with experimental data.

정류용 브릿지 다이오드가 없는 고효율 하프 브릿지 AC-DC 컨버터 (A Bridgeless Half-Bridge AC-DC Converter with High-Efficiency)

  • 최우영;유주승;최제연
    • 전력전자학회논문지
    • /
    • 제16권3호
    • /
    • pp.293-301
    • /
    • 2011
  • 본 논문에서는 정류용 브릿지 다이오드가 없는 고효율 하프 브릿지 AC-DC 컨버터를 제안한다. 제안하는 컨버터는 비대칭 펄스 폭 변조 방식의 하프 브릿지 DC-DC 컨버터와 정류용 브릿지 다이오드가 없는 역률 개선 회로가 통합된 회로 구조를 지닌다. 제안하는 컨버터는 정류용 브릿지 다이오드를 사용하지 않고 교류 입력 전압으로부터 절연된 직류 출력 전압을 공급한다. 간단한 회로 구조와 함께 도통 손실을 줄일 수 있다. 또한 스위칭 소자들의 영전압 스위칭을 통하여 스위칭 손실을 줄일 수 있다. 두 개의 직렬 연결된 트랜스포머를 구비함으로서 프로파일을 낮추고 전력밀도를 높일 수 있다. 250 W (48 V / 5.2 A) 회로 설계 및 실험을 통하여 제안된 컨버터의 성능을 $90 \;V_{rms}$ 교류 입력 전압에 대하여 입증하였다.

Novel Zero-Voltage-Switching Bridgeless PFC Converter

  • Haghi, Rasool;Zolghadri, Mohammad Reza;Beiranvand, Reza
    • Journal of Power Electronics
    • /
    • 제13권1호
    • /
    • pp.40-50
    • /
    • 2013
  • In this paper, a new zero-voltage-switching, high power-factor, bridgeless rectifier is introduced. In this topology, an auxiliary circuit provides soft switching for all of the power semiconductor devices. Thus the switching losses are reduced and the highest efficiency can be achieved. The proposed converter has been analyzed and a design procedure has been introduced. The control circuit for the converter has also been developed. Based on the given approach, a 250 W, 400 Vdc prototype converters has been designed at 100 kHz for universal input voltage (90-264 Vrms) applications. A maximum efficiency of 94.6% and a power factor correction over 0.99 has been achieved. The simulation and experimental results confirm the design procedure and highlight the advantages of the proposed topology.

Semi-bridgeless 정류기를 사용한 IPT 시스템의 PDM 제어 적용에 따른 출력특성 분석 및 시스템 설계 (Output Characteristic Analysis and Design of IPT System with Semi-Bridgeless Rectifier Applying PDM Control)

  • 이재한;손원진;안상준;이병국
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 전력전자학술대회
    • /
    • pp.81-83
    • /
    • 2018
  • 본 논문에서는 inductive power transfer (IPT) 시스템 2차측 semi-bridgeless 정류기에 pulse density modulation (PDM) 제어를 적용하기 위한 시스템 설계 방안을 제안한다. LCCL-S 토폴로지를 사용한 IPT 시스템에 PDM 제어를 적용하였을 때 나타나는 출력특성을 기존의 SS 토폴로지를 사용한 시스템의 출력특성과 비교 분석한다. 분석 결과를 바탕으로, 실제 전기자동차 배터리 충전사양을 고려하여 3.3 kW 급 IPT 시스템을 설계하고 설계 결과를 시뮬레이션을 통해 검증한다.

  • PDF

Semi-bridgeless 정류기를 적용한 IPT 시스템의 PDM 제어에 따른 전류 리플 저감을 위한 공진 네트워크 설계 (Resonance Network Design for Current Ripple Reduction in IPT System with Semi-Bridgeless Rectifier Applying PDM Control)

  • 이재한;손원진;안상준;변종은;이병국
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 추계학술대회
    • /
    • pp.77-79
    • /
    • 2018
  • 본 논문에서는 inductive power transfer (IPT) 시스템 2차측 semi-bridgeless 정류기에 pulse density modulation (PDM) 제어를 적용하였을 때 1차측에 나타나는 영향을 최소화하기 위한 공진 네트워크 설계 방안을 제안한다. PDM 제어를 적용하였을 때 2차측 전류 리플이 증가하는 문제를 해결하기 위해 2차측 수신 인덕턴스를 증가시킴으로써 전류 리플을 저감하여 1차측 영향을 최소화한다. 이를 위해 적절한 설계 조건을 구하는 방안에 대하여 제시하고, 방안의 적용에 따른 1차측 영향을 시뮬레이션을 통해 분석한다.

  • PDF

효율을 고려한 새로운 AC/DC 컨버터 (A novel energy-efficient bridgeless boost AC to DC converter)

  • 윤경국;김성환;김덕기
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제40권3호
    • /
    • pp.223-227
    • /
    • 2016
  • 다이오드를 이용한 정류기는 산업현장에서 널리 응용되고 있다. 그러나 입력전류에 많은 저차고조파가 포함되어 공급전압을 왜곡시켜 전력의 품질을 저하시키므로 이를 완화시킬 수 있는 적절한 설비가 필요하다. 또한 고조파 전류는 전력계통의 전압 왜곡, 가열 및 소음 등을 유발하여 효율을 떨어뜨린다. 고조파를 감소시키고 역률을 상승시키기 위하여 입력전류가 연속적이 되도록 하는 부스트 컨버터가 등장하였다. 본 논문에서는 입력전류에 포함된 고조파 전류를 감소시키고, 역률을 증가시킬 수 있을 뿐 아니라 전체 정류기 효율을 상승시키는 부스트 컨버터를 제안하였다. 이는 기존의 부스트 컨버터에 비해 전류가 통과하는 반도체의 개수가 감소하여 효율의 상승을 기대할 수 있다. 또한, 소프트웨어 PSIM을 활용하여 제안된 변환기의 유효성을 입증하였다.