Chest Wall Reconstruction with a Transverse Rectus Abdominis Musculocutaneous Flap in an Extremely Oversized Heart Transplantation

  • Yim, Ji Hong;Eom, Jin Sup;Kim, Deok Yeol
    • Archives of Reconstructive Microsurgery
    • /
    • 제23권2호
    • /
    • pp.89-92
    • /
    • 2014
  • An 8-year-old girl diagnosed with dilated cardiomyopathy and Russell-Silver syndrome was admitted to our pediatric intensive care unit due to low cardiac output and multiple-organ dysfunction. The patient was placed on the heart transplant waiting list and extracorporeal membrane oxygenation was performed as a bridge to transplantation. After 17 days, heart transplantation was performed. The donor was a 46-year-old female (weight, 50 kg; height, 150 cm). The donor:recipient weight ratio was 3.37:1. Because the dimension and volume of the recipient's thoracic cage were insufficient, the sternum could not be closed. Nine days after transplantation, the patient underwent delayed sternal closure. To obtain adequate space, we left the sternum 4.5 cm apart from each margin using four transverse titanium plates. A transverse rectus abdominis musculocutaneous flap was chosen to cover the wound. Due to the shortage of donors, a size-mismatched pediatric heart transplantation is sometimes unavoidable. Closure of the opened sternum of a transplant recipient can be challenging. Sternal reconstruction after an extremely oversized heart transplantation with transverse titanium plate fixation and a musculocutaneous flap can effectively achieve sternal closure and stability.

전기-기계식 이식형 좌심실 보조 시스템의 개발 및 평가 (Development and Evaluation of a Novel Electro-mechanical Implantable Ventricular Assist System)

  • 조한상;김원곤;이원용;곽승민;김삼성;김재기;김준택;류문호;류은숙
    • 대한의용생체공학회:의공학회지
    • /
    • 제22권4호
    • /
    • pp.349-358
    • /
    • 2001
  • A novel electro-mechanical implantable ventricular assist system is developed as a bridge to transplantation or recovery for patients with end-stage heart failure. The developed system is composed of an implanted blood pump, an external monitoring system which stores data, and a wearable system including a portable external driver and a portable power supply system. The blood pump is designed to be implanted into the left upper abdominal space and provides blood flow from the left ventricular apex to the aorta. The pulsatile blood flow is generated by a double cylindrical cam. There was mo excessive heat emission from the blood pump into the temperature-controlled chamber in the heat test and no stagnated flow within the blood sac by the observation in the flow visualization test. Animal experiments were performed using sheep and calves. The maximum assist flow rate reached 7.85L/min in the animal experiment. The evaluation results showed that the developed system was feasible for the implantable ventricular assist system. The long-term in vitro durability test and mid-term in vivo experiments are in progress and mow the modified next model is under development.

  • PDF

Pediatric Mechanical Circulatory Support

  • Wilmot, Ivan;Lorts, Angela;Morales, David
    • Journal of Chest Surgery
    • /
    • 제46권6호
    • /
    • pp.391-401
    • /
    • 2013
  • Mechanical circulatory support (MCS) in the pediatric heart failure population has a limited history especially for infants, and neonates. It has been increasingly recognized that there is a rapidly expanding population of children diagnosed and living with heart failure. This expanding population has resulted in increasing numbers of children with medically resistant end-stage heart failure. The traditional therapy for these children has been heart transplantation. However, children with heart failure unlike adults do not have symptoms until they present with end-stage heart failure and therefore, cannot safely wait for transplantation. Many of these children were bridged to heart transplantation utilizing extracorporeal membranous oxygenation as a bridge to transplant which has yielded poor results. As such, industry, clinicians, and the government have refocused interest in developing increasing numbers of MCS options for children living with heart failure as a bridge to transplantation and as a chronic therapy. In this review, we discuss MCS options for short and long-term support that are currently available for infants and children with end-stage heart failure.

ENGINEERING A BIOARTIFICIAL LIVER DEVICE

  • 박재성
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1419-1426
    • /
    • 2008
  • Fulminant hepatic failure is a clinical syndrome associated with a high mortality rate. Orthotopic liver transplantation is the only clinically proven effective treatment for patients with end-stage liver disease who do not respond to medical management. A major limitation of this treatment modality is the scarcity of donor organs available, resulting in patients dying while waiting for a donor liver. An extracorporeal bioartificial liver (BAL) device containing viable hepatocytes has the potential to provide temporary hepatic support to liver failure patients, serving as a bridge to transplantation while awaiting a suitable donor. In some patients, providing temporary hepatic support may be sufficient to allow adequate regeneration of the host liver, thereby eliminating the need for a liver transplant. Although the BAL device is a promising technology for the treatment of liver failure, there are several technical challenges that must be overcome in order to develop systems with sufficient processing capacity and of manageable size. In this overview, the authors describe the critical issues involved in developing a BAL device. They also discuss their experiences in hepatocyte culture optimization within the context of a microchannel flat-plate BAL device.

  • PDF

최소 절개술에 의한 반월상 연골 동종이식 수술기법 (Technical Note of Meniscal Allograft Transplantation using Minimal Incision)

  • 민병현;김호성;장동욱;강신영
    • 대한관절경학회지
    • /
    • 제3권1호
    • /
    • pp.54-61
    • /
    • 1999
  • 광범위한 반월상 연골 손상에 대한 최근의 치료는 수많은 연구와 임상적 접근을 통해 정상적인 반월상 연골의 기능을 회복하기에 이르렀다. 냉동 보관된 반월상 연골의 동종이식은 연골의 정상적인 회복을 위한 유용한 방법중 하나이다. 저자들의 첫 4례의 동종연골이식은 관절경의 도움으로 시행하였고, 이후 22 예에서는 최소한의 관절 절개를 이용하였다. 또한 모든 동종 연골 이식에서 반월상 연골의 안정성과 회복을 위해 반월상 연골에 골교를 부착하여 고정하였다. 전방 십자 인대 재건술은 반월상 연골 동종이식술시 동시에 시행하였다. 내측 반월상 연골은 일명 Key-hole technique을 사용하여 골터널에 의한 관절 연골의 침습을 최소화하려 하였다. 우선 반월상 연골의 골교를 원통형으로 만들고 수혜자의 슬관절의 전방 십자 인대의 내측연을 따라 골 터널을 만들어 반월상 연골의 골교를 press-fit하도록 한다. 삽입된 반월상 연골은 일반적인 반월상 연골 봉합술로 관절경을 이용하여 봉합한다. 외측 반월상 연골은 내측 반월상 연골과는 달리 반월상 연골의 골교를 반원통 모앙으로 만들고 수혜자의 슬관절의 전방 십자 인대의 외측연을 따라 반원통 모양의 골 요지를 만든다. 반월상 연골을 골 요지에 얻고 인도 봉합사를 경골의 전면으로 뽑아내 이를 묶음으로써 고정을 한다. 삽입된 반월상 연골은 내측 반월상 연골이식술과 같은 방법으로 봉합한다. 저자들은 이와 같은 방법으로 관절 연골의 침습을 최소화하고 비교적 정확한 위치에 반월상 연골을 이식할 수 있었다.

  • PDF

Critical Care before Lung Transplantation

  • Lee, Jin Gu;Park, Moo Suk;Jeong, Su Jin;Kim, Song Yee;Na, Sungwon;Kim, Jeongmin;Paik, Hyo Chae
    • Acute and Critical Care
    • /
    • 제33권4호
    • /
    • pp.197-205
    • /
    • 2018
  • Lung transplantation is widely accepted as the only viable treatment option for patients with end-stage lung disease. However, the imbalance between the number of suitable donor lungs available and the number of possible candidates often results in intensive care unit (ICU) admission for the latter. In the ICU setting, critical care is essential to keep these patients alive and to successfully bridge to lung transplantation. Proper management in the ICU is also one of the key factors supporting long-term success following transplantation. Critical care includes the provision of respiratory support such as mechanical ventilation (MV) and extracorporeal life support (ECLS). Accordingly, a working knowledge of the common critical care issues related to these unique patients and the early recognition and management of problems that arise before and after transplantation in the ICU setting are crucial for long-term success. In this review, we discuss the management and selection of candidates for lung transplantation as well as existing respiratory support strategies that involve MV and ECLS in the ICU setting.

Bridge to Transplantation with a Left Ventricular Assist Device

  • Jung, Jae-Jun;Sung, Ki-Ick;Jeong, Dong-Seop;Kim, Wook-Sung;Lee, Young-Tak;Park, Pyo-Won
    • Journal of Chest Surgery
    • /
    • 제45권2호
    • /
    • pp.116-119
    • /
    • 2012
  • A 61-year-old female patient was diagnosed with dilated cardiomyopathy with severe left ventricle dysfunction. Two days after admission, continuous renal replacement therapy was performed due to oliguria and lactic acidosis. On the fifth day, an intra-aortic balloon pump was inserted due to low cardiac output syndrome. Beginning 4 days after admission, she was supported for 15 days thereafter with an extracorporeal left ventricular assist device (LVAD) because of heart failure with multi-organ failure. A heart transplant was performed while the patient was stabilized with the LVAD. She developed several complications after the surgery, such as cytomegalovirus pneumonia, pulmonary tuberculosis, wound dehiscence, and H1N1 infection. On postoperative day 19, she was discharged from the hospital with close follow-up and treatment for infection. She received follow-up care for 10 months without any immune rejection reaction.

Outcome of Extracorporeal Ventricular Assist Device for Cardiogenic Shock as a Bridge to Transplantation

  • Kim, Hyo-Hyun;Shin, Jung-Hoon;Kim, Jung-Hwan;Youn, Young-Nam
    • Journal of Chest Surgery
    • /
    • 제53권6호
    • /
    • pp.368-374
    • /
    • 2020
  • Background: The extracorporeal ventricular assist device (e-VAD) system is designed for left ventricular support using a permanent life support console. This study aimed to determine the impact of temporary e-VAD implantation bridging on posttransplant outcomes. Methods: We reviewed the clinical records of 6 patients with the Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) profile 1, awaiting heart transplantation, who were provided with temporary e-VAD from 2018 to 2019. The circuit comprised a single centrifugal pump without an oxygenator. The e-VAD inflow cannula was inserted into the apex of the left ventricle, and the outflow cannula was positioned in the ascending aorta. The median follow-up duration was 8.4±6.9 months. Results: After e-VAD implantation, lactate dehydrogenase levels significantly decreased, and Sequential Organ Failure Assessment scores significantly improved. Bedside rehabilitation was possible in 5 patients. After a mean e-VAD support duration of 14.5±17.3 days, all patients were successfully bridged to transplantation. After transplantation, 5 patients survived for at least 6 months. Conclusion: e-VAD may reverse end-organ dysfunction and improve outcomes in INTERMACS I heart transplant patients.

공압식 심실 보조기의 동물실험 (Animal Experiment of the Pneumatic Ventrivular Assist Device)

  • 박성식;김삼현;서필원;최창휴;이상훈;이혁수;황승옥;안혁
    • Journal of Chest Surgery
    • /
    • 제32권12호
    • /
    • pp.1065-1077
    • /
    • 1999
  • Background : Ventricular assist devices(VADs) are being used for patients in postcvardiotomy cardiogenic shock status bridge to cardiac transplant settings and in post-myocardial infarction cardiogenic shock. The VAD which was developed at the Deparment of medical engineering in Dankook University College of Medicine was a pneumatically driven device and can maintain pulsatile flow. The goal of this study is to develop animal experimental models using the VAD and to clarify the reliability and hemodynamic property adequacy of end organ perfusion durability and severity of thrombotic-hemolytic tendency of the device. Material and Method : The pneumatic VAD was applied to 8 adult female lambs, We examined some hemodynamic parameters such as arterial blood pressure pulmonary capillary wedge pressure(pcwp) pulmonary artery pressure(PAP) left atrial pressure hour urine output cardiac index VAD flow EKG to determine the reliability of the VAD and hemodynamic compatibility of the experimental animals within 24 hours of experiment. We also observed the end organ perfusion durability of the VAD and thrombotic-hemolytic property of the VAD after 24 hours of VAD insertion. Result: We could monitor all hemodynamic parameters including pcwp PAP cardiac index EKG, adn hour urine as true clinical settings. We observed that the reliability of the VAD was excellent and the hemodynamic property of the experimental animal and end organ perfusion were adequate within 24 hours of experiment. In four lambs surviving 24 hours after insertion the reliability of the VAD and end organ perfusion were excellent and no thrombotic-hemolytic tendency was noted. However after 15 days of experiment the diaphragm of the VAD was torn and it was recommende that the durability of the VAD should be extended. Conclusion : e conclude that the pneumatic VAD developed at Dankook University Biomedical Engineering has good hemodynamic property and low thromboembolic tendency and presents adequate end organ perfusion but we noted that the durability of the device should be expanded further. It will be possible to do more reliable experiment in the future according to the animal experimental method developed in this study especially with the heart failure models.

  • PDF