• 제목/요약/키워드: Bridge Mode

검색결과 641건 처리시간 0.022초

Extraction of bridge information based on the double-pass double-vehicle technique

  • Zhan, Y.;Au, F.T.K.;Yang, D.
    • Smart Structures and Systems
    • /
    • 제25권6호
    • /
    • pp.679-691
    • /
    • 2020
  • To identify the bridge information from the response of test vehicles passing on it (also known as the indirect approach) has aroused the interest of many researchers thanks to its economy, easy implementation and less disruption to traffic. The surface roughness of bridge remains an obstacle for such method as it contaminates the vehicle response severely and thereby renders many vehicle-response-based bridge identification methods ineffective. This study aims to eliminate such effect with the responses of two different test vehicles. The proposed method can estimate the surface profile of a bridge based on the acceleration data of the vehicles running on the bridge successively, and obtain the normalized contact point response, which proves to be relatively immune to surface roughness. The frequencies and mode shapes of bridge can be further extracted from the normalized contact point acceleration with spectral analysis and Hilbert transform. The effectiveness of the proposed method is verified numerically with a three-span continuous bridge. The influence of measurement noise is also examined.

모니터링 시스템의 계측자료를 기반으로 한 닐슨아치 교량의 내풍 안정성 평가 (Estimation of Wind Resistance Capacity of Nielsen Arch Bridge Based on Measured Data From Monitoring System)

  • 이덕근;임성순
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제17권3호
    • /
    • pp.56-64
    • /
    • 2013
  • 200m 이하의 아치 교량에서 동적 내풍 안정성은 일반적으로 일본의 Wind Resistant Design Manual for Highway Bridges에 따라 검토된다. 또한 내풍 안정성 검토는 모드 형상에 관계없이 1차 연직 진동수를 적용한다. 일본의 매뉴얼에 따라 설계된 경간장 183m의 닐슨 아치 교량에서 예상치 못한 와류 진동이 발생하였으며 이는 태풍시 교량의 모니터링 시스템에 의해 계측되었다. 본 논문에서는 태풍 발생시에 계측된 풍속, 풍향, 진동 변위와 가속도를 기반으로 닐슨 아치교량의 와류진동 특성을 분석하였다. 분석 결과 1차 연직 진동 모드가 역대칭 형상이고 2차 연직 진동 모드가 대칭 형상인 닐슨 아치교의 경우 와류 진동이 2차 연직 모드에서 지배적이다. 따라서 본 논문에서는 2차 연직 진동 모드가 대칭 형상인 닐슨 아치교의 내풍 안정성 평가시에는 1차 보다 2차 연직 진동 모드가 중요한 설계 요소임을 제시하였다.

Mode identifiability of a cable-stayed bridge under different excitation conditions assessed with an improved algorithm based on stochastic subspace identification

  • Wu, Wen-Hwa;Wang, Sheng-Wei;Chen, Chien-Chou;Lai, Gwolong
    • Smart Structures and Systems
    • /
    • 제17권3호
    • /
    • pp.363-389
    • /
    • 2016
  • Deficient modes that cannot be always identified from different sets of measurement data may exist in the application of operational modal analysis such as the stochastic subspace identification techniques in large-scale civil structures. Based on a recent work using the long-term ambient vibration measurements from an instrumented cable-stayed bridge under different wind excitation conditions, a benchmark problem is launched by taking the same bridge as a test bed to further intensify the exploration of mode identifiability. For systematically assessing this benchmark problem, a recently developed SSI algorithm based on an alternative stabilization diagram and a hierarchical sifting process is extended and applied in this research to investigate several sets of known and blind monitoring data. The evaluation of delicately selected cases clearly distinguishes the effect of traffic excitation on the identifiability of the targeted deficient mode from the effect of wind excitation. An additional upper limit for the vertical acceleration amplitude at deck, mainly induced by the passing traffic, is subsequently suggested to supplement the previously determined lower limit for the wind speed. Careful inspection on the shape vector of the deficient mode under different excitation conditions leads to the postulation that this mode is actually induced by the motion of the central tower. The analysis incorporating the tower measurements solidly verifies this postulation by yielding the prevailing components at the tower locations in the extended mode shape vector. Moreover, it is also confirmed that this mode can be stably identified under all the circumstances with the addition of tower measurements. An important lesson learned from this discovery is that the problem of mode identifiability usually comes from the lack of proper measurements at the right locations.

전류모드로 제어되는 영전압 스위칭 하프 브리지 PWM 컨버터의 해석 (Analysis of Current Mode Controlled Zero Voltage Switching Half Bridge PWM Converter)

  • 정영석;권순재
    • 전력전자학회논문지
    • /
    • 제8권1호
    • /
    • pp.64-69
    • /
    • 2003
  • 전류모드 제어시 전류루프에는 표본화 효과에 의해 저주파 모델로는 예측하기 어려운 고주파 성분이 존재한다. 본 논문에서는 영전압 스위칭 하프 브리지 컨버터의 정상상태에서의 출력전압 관계식을 구한다 또 이를 바탕으로 전류모드로 제어할 때 전류루프에 존재하는 표본화 효과를 고려하여 저주파 소신호 모델이 예측하기 어려운 고주파 성분의 특성을 표본화 이득을 통하여 더욱 정확히 예측할 수 있는 방법을 제시한다.

모드분해기법을 이용한 현수교의 변위응답추정 (Estimation of displacement responses of a suspension bridge by using mode decomposition technique)

  • 장성진;김남식;김호경
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.320-325
    • /
    • 2009
  • In this study, a method to estimate the suspension bridge deflection is developed using mode decomposition technique. In order to examine the suspension bridge stability against these dynamic loadings, the prediction of displacement response is very important to evaluate bridge stability. However, it is recognized that any measurement of movement for suspension bridges may be difficult for the absence of proper methods to measure the displacement response on site. This study aims at suggesting a method to estimate the displacement response from the measured strain signals in an indirect way to predict the displacement response, not a direct way to measure the displacement response. Additionally, by applying the FBG sensors with multi-point measurements not influenced by electric noise, it can be expected that the technique would be applicable to infrastructures.

  • PDF

디스플레이용 스위칭모드 전원장치의 단락 고장분석 검출기법 (Techniques to Diagnose Short-Circuit Faults in the Switching Mode Power Supply for Display)

  • 이재원;전태원
    • 전기학회논문지
    • /
    • 제65권7호
    • /
    • pp.1186-1192
    • /
    • 2016
  • This paper proposes techniques to diagnose short-circuit faults of both the diodes and power FET in switching mode power supply (SMPS) by using a simple analog tester. The diodes in full-bridge rectifier, power FET, switching transformer, and some sensors are modelled with resistor. The total resistance value measured at the input terminal of a SMPS is analyzed when the short-circuit faults of diodes in a full bridge rectifier or power FET are occurred. The short-circuit faults of one or two diodes in a full bridge rectifier, power FET, and both the diodes in a full bridge rectifier and power FET can be detected by a range of total resistance, which is measured by the analog tester. Through experiments, the theoretical analysis for total resistance under short-circuit faults can be verified.

Feasibility study on an acceleration signal-based translational and rotational mode shape estimation approach utilizing the linear transformation matrix

  • Seung-Hun Sung;Gil-Yong Lee;In-Ho Kim
    • Smart Structures and Systems
    • /
    • 제32권1호
    • /
    • pp.1-7
    • /
    • 2023
  • In modal analysis, the mode shape reflects the vibration characteristics of the structure, and thus it is widely performed for finite element model updating and structural health monitoring. Generally, the acceleration-based mode shape is suitable to express the characteristics of structures for the translational vibration; however, it is difficult to represent the rotational mode at boundary conditions. A tilt sensor and gyroscope capable of measuring rotational mode are used to analyze the overall behavior of the structure, but extracting its mode shape is the major challenge under the small vibration always. Herein, we conducted a feasibility study on a multi-mode shape estimating approach utilizing a single physical quantity signal. The basic concept of the proposed method is to receive multi-metric dynamic responses from two sensors and obtain mode shapes through bridge loading test with relatively large deformation. In addition, the linear transformation matrix for estimating two mode shapes is derived, and the mode shape based on the gyro sensor data is obtained by acceleration response using ambient vibration. Because the structure's behavior with respect to translational and rotational mode can be confirmed, the proposed method can obtain the total response of the structure considering boundary conditions. To verify the feasibility of the proposed method, we pre-measured dynamic data acquired from five accelerometers and five gyro sensors in a lab-scale test considering bridge structures, and obtained a linear transformation matrix for estimating the multi-mode shapes. In addition, the mode shapes for two physical quantities could be extracted by using only the acceleration data. Finally, the mode shapes estimated by the proposed method were compared with the mode shapes obtained from the two sensors. This study confirmed the applicability of the multi-mode shape estimation approach for accurate damage assessment using multi-dimensional mode shapes of bridge structures, and can be used to evaluate the behavior of structures under ambient vibration.

FreeBSD 커널 기반의 침입 차단 시스템 성능 분석 (A Performance Analysis of Firewall on the FreeBSD Kernel)

  • 박창서
    • 한국정보통신학회논문지
    • /
    • 제7권8호
    • /
    • pp.1726-1731
    • /
    • 2003
  • 인터넷을 통해서 침입하는 해커나 침입자로부터 기관의 내부 정보시스템을 보호하기 위하여 침입 차단 시스템(firewall)의 사용이 보편화되고 있다. 하지만 사용자 입장에서는 침입 차단 시스템의 성능을 확인 할 수 없을 뿐 아니라, 동작 모드(브리지 모드(Bridge Mode), 게이트웨이 모드(Gateway Mode))에 따른 성능 차이를 알 수 없다. 이러한 문제를 해결하기 위하여 본 논문에서는 침입 차단 시스템의 운영체제(Windows 2000, Linux, FreeBSD) 환경에 따른 성능을 분석하였다. 끝으로 FreeBSD 커널 기반의 침입 차단 시스템을 서로 다른 동작 모드에서 성능을 비교하고 침입 차단 정책 수가 성능에 미치는 영향에 대하여 분석하였다.

Multi-variate Empirical Mode Decomposition (MEMD) for ambient modal identification of RC road bridge

  • Mahato, Swarup;Hazra, Budhaditya;Chakraborty, Arunasis
    • Structural Monitoring and Maintenance
    • /
    • 제7권4호
    • /
    • pp.283-294
    • /
    • 2020
  • In this paper, an adaptive MEMD based modal identification technique for linear time-invariant systems is proposed employing multiple vibration measurements. Traditional empirical mode decomposition (EMD) suffers from mode-mixing during sifting operations to identify intrinsic mode functions (IMF). MEMD performs better in this context as it considers multi-channel data and projects them into a n-dimensional hypercube to evaluate the IMFs. Using this technique, modal parameters of the structural system are identified. It is observed that MEMD has superior performance compared to its traditional counterpart. However, it still suffers from mild mode-mixing in higher modes where the energy contents are low. To avoid this problem, an adaptive filtering scheme is proposed to decompose the interfering modes. The Proposed modified scheme is then applied to vibrations of a reinforced concrete road bridge. Results presented in this study show that the proposed MEMD based approach coupled with the filtering technique can effectively identify the parameters of the dominant modes present in the structural response with a significant level of accuracy.

단독운전 모드 동작에서의 Triple-Active-Bridge 컨버터 제어 기법 및 소신호 모델을 기반으로 한 제어기 설계 (Control Technique of Triple-Active-Bridge Converter and Its Effective Controller Design Based on Small Signal Model for Islanding Mode Operation)

  • 전찬오;허경욱;류명효;정지훈
    • 전력전자학회논문지
    • /
    • 제27권3호
    • /
    • pp.192-199
    • /
    • 2022
  • In DC distribution systems, a TAB converter employing multiple transformers is one of the most widely used topologies due to its high power density, modularizability, and cost-effectiveness. However, the conventional control technique for a grid-connected mode in the TAB converter cannot maintain its reliability for an islanding mode under a blackout situation. In this paper, the islanding mode control technique is proposed to solve this issue. To verify the relative stability and dynamic characteristics of the control technique, small-signal models of both the grid connected and the islanding mode are derived. Based on the small-signal models, PI controllers are designed to provide suitable power control. The proposed control technique, the accuracy of small-signal models, and the performance of the controllers are verified by simulations and experiments with a 1-kW prototype TAB converter.