• 제목/요약/키워드: Bridge Arm

검색결과 57건 처리시간 0.024초

A Comparative Study of Two Diagnostic Methods Based on the Switching Voltage Pattern for IGBT Open-Circuit Faults in Voltage-Source Inverters

  • Wang, Yuxi;Li, Zhan;Xu, Minghui;Ma, Hao
    • Journal of Power Electronics
    • /
    • 제16권3호
    • /
    • pp.1087-1096
    • /
    • 2016
  • This paper reports an investigation conducted on two diagnostic methods based on the switching voltage pattern of IGBT open-circuit faults in voltage-source inverters (VSIs). One method was based on the bridge arm pole voltage, and the other was based on bridge arm line voltage. With an additional simple circuit, these two diagnostic methods detected and effectively identified single and multiple open-circuit faults of inverter IGBTs. A comparison of the times for the diagnosis and anti-interference features between these two methods is presented. The diagnostic time of both methods was less than 280ns in the best case. The diagnostic time for the method based on the bridge arm pole voltage was less than that of the method based on the bridge arm line voltage and was 1/2 of the fundamental period in the worst case. An experimental study was carried out to show the effectiveness of and the differences between these two methods.

교각운동시 팔의 보상작용에 따른 몸통 및 하지근육 활성도 분석 (Analysis of trunk and lower extremity muscle activity according to the compensation of arm during bridge exercise)

  • 오규빈;김세희;김예은;안준성;유시연;정상진;조예빈;주진한;조기훈
    • 대한물리치료과학회지
    • /
    • 제29권3호
    • /
    • pp.12-20
    • /
    • 2022
  • Background: The purpose of this study was to investigate the changes of trunk and lower extremity muscle activity according to the compensation of arm during bridge movement of healthy subject. Design: Cross-sectional Study. Methods: Twenty healthy subjects participated in this study. The subjects performed bridge exercise with 3 different arm positions(arm abduction 45°, 90° and cross-arms) and measured the muscle activity of the trunk and lower extrimity. During bridge exercise with 3 different arm positions, trunk (rectus abdominis, erector spinae) and lower extrimity muscle activity (gluteus medius, biceps femoris, tibialis anterior) were measured using wireless surface EMG. Results: Rectus abdominis and gluteus medius muscle were most activated during bridge exercise with arm abduction 90° and erector spinae and biceps femoris muscle were most activated during bridge exercise with arm abduction 45°. In addition, tibialis anterior muscle was most activated during bridge exercise with arm cross. However, these difference in muscle activity according to the arm position was not statistically significant. Conclusion: As a result of this study, we think that the change in arm position does not induce sufficient instability to increase the muscle activity of the trunk and lower extremity muscles. Therefore, various approaches for inducing instability of the support surface for increasing muscle activity when applying bridge movement in clinical practice should be explored.

Central Arm을 이용한 Full-Bridge 단상 인버터 (A Single Phase Inverter Using the Central Arm)

  • 이호;이화춘;김승룡;박성준
    • 전기학회논문지
    • /
    • 제60권1호
    • /
    • pp.78-84
    • /
    • 2011
  • In this paper, the switching frequency and THD for the reduction instead of traditional single phase inverter using a new type of central arm of the single phase inverter is proposed. The proposed single phase inverter topology, the existing one to add a arm by two-way central switch 3-level output voltage can be raised and, central arm, especially one or two of the switches by using a switch to the diode current switching algorithm was simplified. During the dead time because of this, depending on the direction of the current level does not appear in any other existing level compared to the inverter output voltage level of the THD has the advantage that less can be. The simulation and experimental results verified the validity of the proposed topology.

선박의 회전거동을 고려한 3자유도 충돌모델 (3 DOFs bridge-vessel collision model considering with rotation behaviors of the vessel)

  • 이계희;이성로
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2008년도 정기 학술대회
    • /
    • pp.380-385
    • /
    • 2008
  • 3 DOFs model for the collision analysis of a bridge super-structure and a super-structure of the navigating vessels were proposed and analyzed. The collision event between the super-structure of vessel and the super-structure of bridge are different from the normal collision event that collided at sub-structure of bridge. Because of its moment arm, the stability force of vessel could affect to the collision behaviors. To consider this effect, 3 DOFs model including two translation DOFs and one rotational DOF were introduced. The restoration forces of the collision system were considered as nonlinear springs. The equations of motion were derived if form of differential equations and numerically solved by 4th order Runge-Kutta method. The accuracy and the feasibility of this model were verified by the numerical example with parameter of moment arm length.

  • PDF

유도형 전압 분할기의 비 교정용 브리지 개발 (Development of a Ratio Calibration Bridge for Inductive Voltage Dividers)

  • 강전홍;한상옥;김한준
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권5호
    • /
    • pp.217-221
    • /
    • 2005
  • A inductive voltage divider(IVD) is widely used as a ratio arm of precise impedance measurement bridges at low frequencies of audio frequency range and a well fabricated IVD has ratio error of $10^{-7}$ order without any calibration. Recently, the order of $10^{-8}$ of the best measurement uncertainty is needed for calibration and maintenance of impedance standards as national standards. In order to achieve that uncertainty, the IVD which is used for a ratio arm of precise impedance measurement bridge should be calibrated within the uncertain of order of $10^{-8}$ For this purpose, a ratio calibration bridge for IVDs has been developed. The measurement uncertainties of both inphase and quadrature of the bridge are analyzed less then $3{\times}10^{-8}$ respectively at 1 kHz and 25 V.

변압기를 이용한 HBML 인버터의 스위칭소자 저감 (Reducing Switching Device of the HBML Inverter using the Transformers)

  • 이희창;이상훈;송성근;조수억;박성준;이만형
    • 전력전자학회논문지
    • /
    • 제10권1호
    • /
    • pp.95-101
    • /
    • 2005
  • 본 연구에서는 H-Bridge 인버터와 변압기 조합에 의한 다중레벨 인버터로 구성함에 있어 스위칭 소자수를 저감하기 위해 각 H-Bridge 인버터의 한 암을 공통으로 사용할 수 있는 전력회로를 제안한다. 또한 각 인버터에 연결된 변압기의 이용률을 동일하게 할 수 있는 스위칭 방식의 제안으로 각 변압기의 용량을 동일하게 하였다. 제안된 전력회로 및 제어신호의 타당성을 입증하기 위해 프로토 타입 인버터에 대하여 실험을 행하였다

A Study on a Single-Phase Module UPS using a Three-Arm Converter/Inverter

  • Choi Y.K.;Ko T.G.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.987-993
    • /
    • 2003
  • The module UPS can flexibly implement expansion of power system capacities. Furthermore, it can be used to build up the parallel redundant system to improve the reliability of power system operation. To realize the module UPS, load sharing without interconnection among parallel connecting modules as well as a small scale and lightweight topology is necessary. In this paper, the three-arm converter/inverter is compared with the general full-bridge and half-bridge topology from a practical point of view and chosen as the module UPS topology. The switching control approaches based on a pulse width modulation of the converter and inverter of the system are presented independently The frequency and voltage droop method is applied to parallel operation control to achieve load sharing. Two prototype 3kVA modules are designed and implemented to confirm the effectiveness of the proposed approaches. Experimental results show that the three-arm UPS system has a high power factor, a low distortion of output voltage and input current, and good load sharing characteristic.

  • PDF

A Study on a Single-Phase Module UPS using a Three-Arm Converter/Inverter

  • Koo, Tae-Geun;Byun, Young-Bok;Joe, Ki-Yeon;Kim, Dong-Hee;Kim, Chul-U
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제3B권1호
    • /
    • pp.44-51
    • /
    • 2003
  • The module UPS can flexibly implement expansion of power system capacities. Further-more, it can be used to build up the parallel redundant system to improve the reliability of power system operation. To realize the module UPS, load sharing without interconnection among parallel connecting modules as well as a small scale and lightweight topology is necessary. In this paper, the three-arm converter/inverter is compared with the general full-bridge and half-bridge topology from a practical point of view and chosen as the module UPS topology. The switching control approaches based on a pulse width modulation of the converter and inverter of the system are presented independently. The frequency and voltage droop method is applied to parallel operation control to achieve load sharing. Two prototype 3㎸A modules are designed and implemented to confirm the effectiveness of the pro-posed approaches. Experimental results show that the three-arm UPS system has a high power factor, a low distortion of output voltage and input current, and good load sharing characteristics.

사용후핵연료 차세대관리 공정장치 유지보수용 천정이동 서보 매니퓰레이터 와이어 구동부 동작특성 (Transmission Characteristics on Wire-Driven Links of a Bridge Transported Servo Manipulator for the ACP Equipment Maintenance)

  • 박병석;진재현;송태길;김성현;윤지섭
    • 방사성폐기물학회지
    • /
    • 제2권3호
    • /
    • pp.189-199
    • /
    • 2004
  • 기계식 마스터-슬레이브 매니퓰레이터의 결점인 접근 지역의 제한을 극복하기 위해 차세대관리 공정장치 원격 유지보수용 천정이동 서보 매니퓰레이터(Bridge Transported Servo Manipulator, BTSM) 시스템을 개발하고 있다. 서보 매니퓰레이터는 핫셀 내 천정이동 브릿지(bridge)에 부착되는 슬레이브 매니퓰레이터와 핫셀 밖 운전지 역에 설치되는 마스터 매니퓰레이터로 구성된다. 각각의 매니퓰레이터는 몸체 회전, 상부 팔 틸트(tilt), 하부 팔 틸트, 하부 팔 회전, 손목 팬/틸트(pan & tilt) 및 잡는 운동(grasp motion)의 7 자유도를 갖는다. 하부 팔 회전, 손목 팬/틸트 및 잡는 운동은 매니퓰레이터의 무게에 비해 취급 용량을 크게 하고, 마찰을 작게 하기 위하여 와이어 구동 메카니즘을 채택하였다. 그러나, 와이어 구동 메카니즘은 한 축이 움직일 때 다른 축도 영향을 받을 수 있는 단점이 있다. 본 논문에서는 이와 같은 단점을 극복하기 위해 와이어 구동 링크(link) 사이의 전달 특성을 수식화 하였다. 와이어구동 링크들간의 전달특성 분석 및 실험을 통해서 이들의 기대하지 않은 동작 특성을 확인하였다. 또한, 제안한 보상식을 통해서 기대하지 않은 동작을 크게 줄일 수 있음을 확인하였다.

  • PDF