• Title/Summary/Keyword: Bridge Arm

Search Result 57, Processing Time 0.023 seconds

A Comparative Study of Two Diagnostic Methods Based on the Switching Voltage Pattern for IGBT Open-Circuit Faults in Voltage-Source Inverters

  • Wang, Yuxi;Li, Zhan;Xu, Minghui;Ma, Hao
    • Journal of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.1087-1096
    • /
    • 2016
  • This paper reports an investigation conducted on two diagnostic methods based on the switching voltage pattern of IGBT open-circuit faults in voltage-source inverters (VSIs). One method was based on the bridge arm pole voltage, and the other was based on bridge arm line voltage. With an additional simple circuit, these two diagnostic methods detected and effectively identified single and multiple open-circuit faults of inverter IGBTs. A comparison of the times for the diagnosis and anti-interference features between these two methods is presented. The diagnostic time of both methods was less than 280ns in the best case. The diagnostic time for the method based on the bridge arm pole voltage was less than that of the method based on the bridge arm line voltage and was 1/2 of the fundamental period in the worst case. An experimental study was carried out to show the effectiveness of and the differences between these two methods.

Analysis of trunk and lower extremity muscle activity according to the compensation of arm during bridge exercise (교각운동시 팔의 보상작용에 따른 몸통 및 하지근육 활성도 분석)

  • Oh, Gku Bin;Kim, Se Hee;Kim, Ye Eun;An, Jun Sung;You, Si Yeon;Jung, Sang Jin;Cho, Ye Bin;Ju, Jin Han;Cho, Ki Hun
    • Journal of Korean Physical Therapy Science
    • /
    • v.29 no.3
    • /
    • pp.12-20
    • /
    • 2022
  • Background: The purpose of this study was to investigate the changes of trunk and lower extremity muscle activity according to the compensation of arm during bridge movement of healthy subject. Design: Cross-sectional Study. Methods: Twenty healthy subjects participated in this study. The subjects performed bridge exercise with 3 different arm positions(arm abduction 45°, 90° and cross-arms) and measured the muscle activity of the trunk and lower extrimity. During bridge exercise with 3 different arm positions, trunk (rectus abdominis, erector spinae) and lower extrimity muscle activity (gluteus medius, biceps femoris, tibialis anterior) were measured using wireless surface EMG. Results: Rectus abdominis and gluteus medius muscle were most activated during bridge exercise with arm abduction 90° and erector spinae and biceps femoris muscle were most activated during bridge exercise with arm abduction 45°. In addition, tibialis anterior muscle was most activated during bridge exercise with arm cross. However, these difference in muscle activity according to the arm position was not statistically significant. Conclusion: As a result of this study, we think that the change in arm position does not induce sufficient instability to increase the muscle activity of the trunk and lower extremity muscles. Therefore, various approaches for inducing instability of the support surface for increasing muscle activity when applying bridge movement in clinical practice should be explored.

A Single Phase Inverter Using the Central Arm (Central Arm을 이용한 Full-Bridge 단상 인버터)

  • Lee, Ho;Lee, Hwa-Choon;Kim, Seung-Ryong;Park, Sung-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.1
    • /
    • pp.78-84
    • /
    • 2011
  • In this paper, the switching frequency and THD for the reduction instead of traditional single phase inverter using a new type of central arm of the single phase inverter is proposed. The proposed single phase inverter topology, the existing one to add a arm by two-way central switch 3-level output voltage can be raised and, central arm, especially one or two of the switches by using a switch to the diode current switching algorithm was simplified. During the dead time because of this, depending on the direction of the current level does not appear in any other existing level compared to the inverter output voltage level of the THD has the advantage that less can be. The simulation and experimental results verified the validity of the proposed topology.

3 DOFs bridge-vessel collision model considering with rotation behaviors of the vessel (선박의 회전거동을 고려한 3자유도 충돌모델)

  • Lee, Gye-Hee;Lee, Seong-Lo
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2008.04a
    • /
    • pp.380-385
    • /
    • 2008
  • 3 DOFs model for the collision analysis of a bridge super-structure and a super-structure of the navigating vessels were proposed and analyzed. The collision event between the super-structure of vessel and the super-structure of bridge are different from the normal collision event that collided at sub-structure of bridge. Because of its moment arm, the stability force of vessel could affect to the collision behaviors. To consider this effect, 3 DOFs model including two translation DOFs and one rotational DOF were introduced. The restoration forces of the collision system were considered as nonlinear springs. The equations of motion were derived if form of differential equations and numerically solved by 4th order Runge-Kutta method. The accuracy and the feasibility of this model were verified by the numerical example with parameter of moment arm length.

  • PDF

Development of a Ratio Calibration Bridge for Inductive Voltage Dividers (유도형 전압 분할기의 비 교정용 브리지 개발)

  • Kang Jeon Hong;Han Sang Ok;Kim Han Jun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.5
    • /
    • pp.217-221
    • /
    • 2005
  • A inductive voltage divider(IVD) is widely used as a ratio arm of precise impedance measurement bridges at low frequencies of audio frequency range and a well fabricated IVD has ratio error of $10^{-7}$ order without any calibration. Recently, the order of $10^{-8}$ of the best measurement uncertainty is needed for calibration and maintenance of impedance standards as national standards. In order to achieve that uncertainty, the IVD which is used for a ratio arm of precise impedance measurement bridge should be calibrated within the uncertain of order of $10^{-8}$ For this purpose, a ratio calibration bridge for IVDs has been developed. The measurement uncertainties of both inphase and quadrature of the bridge are analyzed less then $3{\times}10^{-8}$ respectively at 1 kHz and 25 V.

Reducing Switching Device of the HBML Inverter using the Transformers (변압기를 이용한 HBML 인버터의 스위칭소자 저감)

  • Lee H.C;Lee S.H.;Song S.G.;Cho S.E.;Park S.J.;Lee M.H
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.1
    • /
    • pp.95-101
    • /
    • 2005
  • In this paper, we proposed the electric circuit using one common arm of H-Bridge Inverters to reduce the number of switching component in multi-level PWM inverter combined with H-Bridge Inverters and Transformers. and we proposed the switching method that can be same rate of usage at each transformer. Also, we tested the proposed prototype inverter to clarify the proposed electric circuit and reasonableness of control signal.

A Study on a Single-Phase Module UPS using a Three-Arm Converter/Inverter

  • Choi Y.K.;Ko T.G.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.987-993
    • /
    • 2003
  • The module UPS can flexibly implement expansion of power system capacities. Furthermore, it can be used to build up the parallel redundant system to improve the reliability of power system operation. To realize the module UPS, load sharing without interconnection among parallel connecting modules as well as a small scale and lightweight topology is necessary. In this paper, the three-arm converter/inverter is compared with the general full-bridge and half-bridge topology from a practical point of view and chosen as the module UPS topology. The switching control approaches based on a pulse width modulation of the converter and inverter of the system are presented independently The frequency and voltage droop method is applied to parallel operation control to achieve load sharing. Two prototype 3kVA modules are designed and implemented to confirm the effectiveness of the proposed approaches. Experimental results show that the three-arm UPS system has a high power factor, a low distortion of output voltage and input current, and good load sharing characteristic.

  • PDF

A Study on a Single-Phase Module UPS using a Three-Arm Converter/Inverter

  • Koo, Tae-Geun;Byun, Young-Bok;Joe, Ki-Yeon;Kim, Dong-Hee;Kim, Chul-U
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.3B no.1
    • /
    • pp.44-51
    • /
    • 2003
  • The module UPS can flexibly implement expansion of power system capacities. Further-more, it can be used to build up the parallel redundant system to improve the reliability of power system operation. To realize the module UPS, load sharing without interconnection among parallel connecting modules as well as a small scale and lightweight topology is necessary. In this paper, the three-arm converter/inverter is compared with the general full-bridge and half-bridge topology from a practical point of view and chosen as the module UPS topology. The switching control approaches based on a pulse width modulation of the converter and inverter of the system are presented independently. The frequency and voltage droop method is applied to parallel operation control to achieve load sharing. Two prototype 3㎸A modules are designed and implemented to confirm the effectiveness of the pro-posed approaches. Experimental results show that the three-arm UPS system has a high power factor, a low distortion of output voltage and input current, and good load sharing characteristics.

Transmission Characteristics on Wire-Driven Links of a Bridge Transported Servo Manipulator for the ACP Equipment Maintenance (사용후핵연료 차세대관리 공정장치 유지보수용 천정이동 서보 매니퓰레이터 와이어 구동부 동작특성)

  • 박병석;진재현;송태길;김성현;윤지섭
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.2 no.3
    • /
    • pp.189-199
    • /
    • 2004
  • A bridge transported servo manipulator (BTSM) system for the advanced spent fuel conditioning process (ACP) has been developed to overcome the limitation of access, which is a drawback of mechanical master-slave manipulators (MSM) for the equipment maintenance. The servo manipulator is composed of a slave manipulator attached to the telescoping tubesets equipped with the overhead bridge installed at a hot cell and a master manipulator installed at an out-of-hot cell. Each manipulator has 7 degrees-of-freedom (DOF): a body rotation, an upper-arm tilt, a lower-arm tilt, a lower-arm rotation, a wrist pan & tilt, and a grasp motion. A wire-driven mechanism for a lower-arm rotation, a wrist pan and tilt, and a grasp motion of the manipulator has been adopted to increase the handling capacity compared to the manipulator weight and decrease the friction. The main disadvantage of the wire-driven mechanism is that if one link is in motion, other links can be affected. In this paper, the transmission characteristics among the wire-driven links have been formulated to overcome this drawback. The unexpected behaviors are confirmed by analyses of transmission characteristics as well as experiments. Also, the experimental results show that the unexpected behaviors are greatly decreased by the proposed compensation equations.

  • PDF