• Title/Summary/Keyword: Breast imaging

Search Result 415, Processing Time 0.02 seconds

Acquisition of Monochromatic X-ray using Graded Multilayer Mirror (Graded 다층박막거울을 이용한 단색 엑스선 획득)

  • Ryu, Cheolwoo;Choi, Byoungjung;Son, Hyunhwa;Kwon, Youngman;Kim, Byoungwook;Kim, Youngju;Chon, Kwonsu
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.4
    • /
    • pp.205-211
    • /
    • 2015
  • At a recent medical imaging technology, the major issue of X-ray diagnosis in breast cancer is the early detection of breast cancer and low patient's exposure dose. As one of studies to acquire a monochromatic X-ray, Technologies using multilayer mirror had been preceded. However, a uniform multilayer mirror that consists of uniform thin-film thickness can acquire a monochromatic X-ray only in the partial area corresponds to angle of incidence of white X-ray, so there are limits for X-ray imaging technology applications. In this study, we designed laterally graded multilayer mirror(below GML) that reflects same monochromatic X-ray over the entire area of thin-film mirror, which have the the thickness of the linear gradient that correspond to angle of incidence of white X-ray. By using ion-beam sputtering system added the mask control system we fabricated a GML which has size of $100{\times}100mm^2$. The GML is designed to achieve the monochromatic X-ray of 17.5kev energy and has thin-film thickness change from 4.62nm to 6.57nm(3.87nm at center). It reflects the monochromatic X-ray with reflectivity of more than 60 percent, FWHM of below 2.6keV and X-ray beam width of about 3mm. The monochromatic X-ray corresponded to 17.5keV using GML would have wide application in development of mammography system with high contrast and low dose.

Analysis of Factors Related to Pain Relief on Modified Mammography (변형 유방촬영술시 통증완화에 따른 요인 분석)

  • Jang, Myung Mi;Kim, Hwa Sun
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.5
    • /
    • pp.413-421
    • /
    • 2017
  • Mammography, the basic test for finding and treating increased breast cancer, gives the anxiety of cancer and radiation exposure to most women. In addition, it gave very severe compression pain, so we studied the degree of pain and tried to reduce the pain. The purpose of this study is to compare and analyze the modified imaging technique and the basic imaging technique based on clinical experience, respectively. The subjects of this study were 160 women from 30 to 60 years old who visited to Seoul Boramae Hospital operated by Seoul National University Hospital from February to March 2017 for breast screening. Modified 80 persons and 80 persons were divided into two groups, and each group was asked to fill out questionnaires sequentially without knowing the subjects. The first method is a modified method in which an automatic pedal is divided into four or more presses, a manual pressure is used together, and an attitude is described in detail. Secondly, we used only the automatic pedal compression method and press it within 1-3 times. In the mean of the pain distribution, the experimental group (modified method) was 2.49 and the control group (basic method) had an average of 4.86, which showed 48.8% less pain. In this modified method, the pain scores of the experimental group were lower than those of the control group, and the degree of the pain was statistically significant.

Ultrafast MRI and T1 and T2 Radiomics for Predicting Invasive Components in Ductal Carcinoma in Situ Diagnosed With Percutaneous Needle Biopsy

  • Min Young Kim;Heera Yoen;Hye Ji;Sang Joon Park;Sun Mi Kim;Wonshik Han;Nariya Cho
    • Korean Journal of Radiology
    • /
    • v.24 no.12
    • /
    • pp.1190-1199
    • /
    • 2023
  • Objective: This study aimed to investigate the feasibility of ultrafast magnetic resonance imaging (MRI) and radiomic features derived from breast MRI for predicting the upstaging of ductal carcinoma in situ (DCIS) diagnosed using percutaneous needle biopsy. Materials and Methods: Between August 2018 and June 2020, 95 patients with 98 DCIS lesions who underwent preoperative breast MRI, including an ultrafast sequence, and subsequent surgery were included. Four ultrafast MRI parameters were analyzed: time-to-enhancement, maximum slope (MS), area under the curve for 60 s after enhancement, and time-to-peak enhancement. One hundred and seven radiomic features were extracted for the whole tumor on the first post-contrast T1WI and T2WI using PyRadiomics. Clinicopathological characteristics, ultrafast MRI findings, and radiomic features were compared between the pure DCIS and DCIS with invasion groups. Prediction models, incorporating clinicopathological, ultrafast MRI, and radiomic features, were developed. Receiver operating characteristic curve analysis and area under the curve (AUC) were used to evaluate model performance in distinguishing between the two groups using leave-one-out cross-validation. Results: Thirty-six of the 98 lesions (36.7%) were confirmed to have invasive components after surgery. Compared to the pure DCIS group, the DCIS with invasion group had a higher nuclear grade (P < 0.001), larger mean lesion size (P = 0.038), larger mean MS (P = 0.002), and different radiomic-related characteristics, including a more extensive tumor volume; higher maximum gray-level intensity; coarser, more complex, and heterogeneous texture; and a greater concentration of high gray-level intensity. No significant differences in AUCs were found between the model incorporating nuclear grade and lesion size (0.687) and the models integrating additional ultrafast MRI and radiomic features (0.680-0.732). Conclusion: High nuclear grade, larger lesion size, larger MS, and multiple radiomic features were associated with DCIS upstaging. However, the addition of MS and radiomic features to the prediction model did not significantly improve the prediction performance.

Changes in Breast-tumor Blood Flow in Response to Hypercapnia during Chemotherapy with Laser Speckle Flowmetry

  • Kim, Hoonsup;Lee, Youngjoo;Lee, Songhyun;Kim, Jae Gwan
    • Current Optics and Photonics
    • /
    • v.3 no.6
    • /
    • pp.555-565
    • /
    • 2019
  • Development of a biomarker for predicting tumor-treatment efficacy is a matter of great concern, to reduce time, medical expense, and effort in oncology therapy. In a preclinical study, we hypothesized that the blood-flow parameter based on laser speckle flowmetry (LSF) could be a potential indicator to estimate the efficacy of breast-cancer treatment. To verify this hypothesis, a 13762-MAT-B-III rat breast tumor was grown in a dorsal skinfold window chamber applied to a nude mouse, and the change in blood flow rate (BFR) - or the speckle flow index (SFI) is used together as the same meaning in this manuscript - was longitudinally monitored during tumor growth and metronomic cyclophosphamide treatment. Based on the daily LSF angiogram, several BFR parameters (baseline SFI, normalized SFI, and △rBFR) were compared to tumor size in the normal, treated, and untreated tumor groups. Despite the incomplete tumor treatment, we found that the daily changes in all BFR parameters tended to have partially positive correlation with tumor size. Moreover, we observed that the changes in baseline SFI and normalized SFI responded one day earlier than the tumor shrinkage during chemotherapy. However, daily variations in the hypercapnia-induced △rBFR lagged tumor shrinkage by one day. This study would contribute not only to evaluating tumor vascular response to treatment, but also to monitoring blood-flow-mediated diseases (in brain, skin, and retina) by using LSF in preclinical settings.

Performance Indices of Needle Biopsy Procedures for the Assessment of Screen Detected Abnormalities in Services Accredited by BreastScreen Australia

  • Farshid, Gelareh;Sullivan, Thomas;Jones, Simeon;Roder, David
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.24
    • /
    • pp.10665-10673
    • /
    • 2015
  • Background: We wished to analyse patterns of use of needle biopsy procedures by BreastScreen Australia (BSA) accredited programs to identify areas for improvement. Design: BSA services provided anonymous data regarding percutaneous needle biopsy of screen detected lesions assessed between 2005-2009. Results: 12 services, from 5 of 7 Australian states and territories provided data for 18212 lesions biopsied. Preoperative diagnosis rates were 96.84% for lesion other than microcalcification (LOTM) and 93.21% for microcalcifications. At surgery 97.9% impalpable lesions were removed at the first procedure. Of 11548 Microcalcification (LOTM) biopsied, 46.9% were malignant. The final diagnosis was reached by conventional core biopsy (CCB) in 72.46%, FNAB in 21.33%, VACB in 1.69% and open biopsy in 4.52% of lesions. FNA is being limited to LOTM with benign imaging After FNAB, core biopsy was required for 38% of LOTM. In LOTM the mean false positive rate (FPR) was 0.36% for FNAB, 0.06% for NCB and 0% for VACB. Diagnostic accuracy was 72.75% for FNAB and 92.1% for core biopsies combined. Of 6441 microcalcifications biopsied 2305 (35.8%) were malignant. Microcalcifications are being assessed primarily by NCB but 6.57% underwent FNAB, 45.6% of which required NCB. False positive diagnoses were rare. FNR was 5% for NCB and 1.53% for VACB. Diagnostic accuracy was 73.52% for FNAB, 86.29% for NCB and 88.63% for VACB. Only 8 of 12 services had access to VACB facilities. Conclusions: BSA services are selecting lesions effectively for biopsy and are achieving high preoperative diagnosis rates. Gaps in the present accreditation standards require further consideration.

Convergence of the Image Evaluation by BI-RADS Classification in Accordance with Algorithms in DR Mammography (디지털 유방촬영술에서 BI-RADS의 구분에 따른 알고리즘별 영상의 융복합적 평가)

  • Lee, Mi-Hwa
    • Journal of Digital Convergence
    • /
    • v.13 no.9
    • /
    • pp.489-495
    • /
    • 2015
  • Image availability evaluated by the degree of agreement and sensitive using the process improve visualization according to the Algorithm modification in Image Post-Processing. Reliability measured by the Breast Imaging Reporting and Data System. 172 patients visit same period divided by BI-RADS, category five stages, and contents of breast parenchyma into Calcification, Nodule and Mass. Evaluated the TE/PV image reliability, visualization sensitive, agreement of diagnosis. Convergence analysis was an in various fields. According to the result of this research, PV has higher sensitive and accuracy about lesions than TE visual and there is a difference insensitive by contents of breast parenchyma. Therefore, practical use of Algorithm Modification(Tissue Equalization: TE, Premium View: PV) is expected to improve more accurate, useful diagnosis, which has not been easy until now.

Analysis of Radiation Protection, Awareness and Attitude of Radiological Technologist in Mammography Room (유방촬영실에 근무하는 방사선사의 방사선 방어, 인식 및 태도에 관한 분석)

  • Hong, Dong-Hee
    • Journal of radiological science and technology
    • /
    • v.40 no.4
    • /
    • pp.557-565
    • /
    • 2017
  • This study was conducted to investigate the radiation protection, awareness, and attitude of radiological technologists in the mammography room due to the low energy use of breast imaging. Data collection was performed by 222 independent radiological technologists in the breast and breast clinic of six hospitals except Jeju Island. The independent sample t-test and oneway variance analysis were performed. As a result, it was found that the lower the number of men(p<0.05), the age of 30s(p<0.05), the marriage(p<0.05), the work experience of more than 10 years(p<0.05), the working hours of 8 hours(p<0.01), the less the impact of radiation(p<0.01), the more important it was to radiation defense. appear. This is thought to be influenced by the work specificity and work environment of the mammography room, and it will be used as a basic data to raise awareness and act on the exposure through analysis with other factors.

Preservation through Cloning of Superior Canine Scent Detection Ability for Cancer Screening (복제를 통한 우수한 암탐지 능력의 보존)

  • Kim, Min-Jung;Park, Jung-Eun;Oh, Hyun-Ju;Hong, So-Gun;Kang, Jung-Taek;Rhim, Sang-Hyun;Lee, Dong-Won;Ra, Jung-Chan;Lee, yeong-Chun
    • Journal of Veterinary Clinics
    • /
    • v.32 no.4
    • /
    • pp.352-355
    • /
    • 2015
  • This study was conducted to ascertain whether the scent detection ability of a donor dog having extraordinary talent in cancer detection can be conserved through cloning. A specially trained dog for colorectal cancer detection was cloned, and she was trained and tested to detect breast cancers using breath samples collected from patients and healthy volunteers. Scent detection sensitivity of the clone was 93.3% and specificity was 99.5%, similar with those of donor (91% and 99%). Furthermore, the clone successfully detected early stage of breast cancers. Therefore, superior canine scent detection ability for cancer screening could be preserved through cloning.

Analysis of breast shielding rate of bismuth shield (비스무스 차폐체의 유방 차폐율 분석)

  • Kim, Jae Seok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.9
    • /
    • pp.1132-1137
    • /
    • 2020
  • In order to reduce unnecessary exposure doses generated when mammography is performed using a mammography device, a shielding ratio analysis was performed when a self-made shielding body made of bismuth was applied to the breast opposite to the imaging site. In order to determine the scattering dose of uncompressed breasts during CC and MLO tests when the right and left are compressed, the experiment is divided into when bismuth is not shielded (Not used: NU group) and when shielded (Used: U group). Proceeded. The average dose of the NU group was 9.568μSv, and the average dose of the U group was 1.038μSv. The average measured dose before and after the use of the bismuth shield was reduced by 89.15%. The use of a bismuth shield for mammography can shield scattered radiation and keep exposure to radiation to a minimum.

Reproducibility Evaluation of Deep inspiration breath-hold(DIBH) technique by respiration data and heart position analysis during radiation therapy for Left Breast cancer patients (좌측 유방암 환자의 방사선치료 중 환자의 호흡과 심장 위치 분석을 통한 Deep inspiration breath-hold(DIBH) 기법의 재현성 평가)

  • Jo, Jae Young;Bae, Sun Myung;Yoon, In Ha;Lee, Ho Yeon;Kang, Tae Young;Baek, Geum Mun;Bae, Jae Beom
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.297-303
    • /
    • 2014
  • Purpose : The purpose of this study is reproducibility evaluation of deep inspiration breath-hold(DIBH) technique by respiration data and heart position analysis in radiation therapy for Left Breast cancer patients. Materials and Methods : Free breathing(FB) Computed Tomography(CT) images and DIBH CT images of three left breast cancer patients were used to evaluate the heart volume and dose during treatment planing system( Eclipse version 10.0, Varian, USA ). The signal of RPM (Real-time Position Management) Respiratory Gating System (version 1.7.5, Varian, USA) was used to evaluate respiration stability of DIBH during breast radiation therapy. The images for measurement of heart position were acquired by the Electronic portal imaging device(EPID) cine acquisition mode. The distance of heart at the three measuring points(A, B, C) on each image was measured by Offline Review (ARIA 10, Varian, USA). Results : Significant differences were found between the FB and DIBH plans for mean heart dose (6.82 vs. 1.91 Gy), heart $V_{30}$ (68.57 vs. $8.26cm^3$), $V_{20}$ (76.43 vs. $11.34cm^3$). The standard deviation of DIBH signal of each patient was ${\pm}0.07cm$, ${\pm}0.04cm$, ${\pm}0.13cm$, respectively. The Maximum and Minimum heart distance on EPID images were measured as 0.32 cm and 0.00 cm. Conclusion : Consequently, using the DIBH technique with radiation therapy for left breast cancer patients is very useful to establish the treatment plan and to reduce the heart dose. In addition, it is beneficial to using the Cine acquisition mode of EPID for the reproducibility evaluation of DIBH.