• Title/Summary/Keyword: Breast imaging

Search Result 415, Processing Time 0.023 seconds

Computer Assisted EPID Analysis of Breast Intrafractional and Interfractional Positioning Error (유방암 방사선치료에 있어 치료도중 및 분할치료 간 위치오차에 대한 전자포탈영상의 컴퓨터를 이용한 자동 분석)

  • Sohn Jason W.;Mansur David B.;Monroe James I.;Drzymala Robert E.;Jin Ho-Sang;Suh Tae-Suk;Dempsey James F.;Klein Eric E.
    • Progress in Medical Physics
    • /
    • v.17 no.1
    • /
    • pp.24-31
    • /
    • 2006
  • Automated analysis software was developed to measure the magnitude of the intrafractional and interfractional errors during breast radiation treatments. Error analysis results are important for determining suitable planning target volumes (PTV) prior to Implementing breast-conserving 3-D conformal radiation treatment (CRT). The electrical portal imaging device (EPID) used for this study was a Portal Vision LC250 liquid-filled ionization detector (fast frame-averaging mode, 1.4 frames per second, 256X256 pixels). Twelve patients were imaged for a minimum of 7 treatment days. During each treatment day, an average of 8 to 9 images per field were acquired (dose rate of 400 MU/minute). We developed automated image analysis software to quantitatively analyze 2,931 images (encompassing 720 measurements). Standard deviations ($\sigma$) of intrafractional (breathing motion) and intefractional (setup uncertainty) errors were calculated. The PTV margin to include the clinical target volume (CTV) with 95% confidence level was calculated as $2\;(1.96\;{\sigma})$. To compensate for intra-fractional error (mainly due to breathing motion) the required PTV margin ranged from 2 mm to 4 mm. However, PTV margins compensating for intefractional error ranged from 7 mm to 31 mm. The total average error observed for 12 patients was 17 mm. The intefractional setup error ranged from 2 to 15 times larger than intrafractional errors associated with breathing motion. Prior to 3-D conformal radiation treatment or IMRT breast treatment, the magnitude of setup errors must be measured and properly incorporated into the PTV. To reduce large PTVs for breast IMRT or 3-D CRT, an image-guided system would be extremely valuable, if not required. EPID systems should incorporate automated analysis software as described in this report to process and take advantage of the large numbers of EPID images available for error analysis which will help Individual clinics arrive at an appropriate PTV for their practice. Such systems can also provide valuable patient monitoring information with minimal effort.

  • PDF

Adaptive Image Rescaling for Weakly Contrast-Enhanced Lesions in Dedicated Breast CT: A Phantom Study (약하게 조영증강된 병변의 유방 전용 CT 영상의 대조도 개선을 위한 적응적 영상 재조정 방법: 팬텀 연구)

  • Bitbyeol Kim;Ho Kyung Kim;Jinsung Kim;Yongkan Ki;Ji Hyeon Joo;Hosang Jeon;Dahl Park;Wontaek Kim;Jiho Nam;Dong Hyeon Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.6
    • /
    • pp.1477-1492
    • /
    • 2021
  • Purpose Dedicated breast CT is an emerging volumetric X-ray imaging modality for diagnosis that does not require any painful breast compression. To improve the detection rate of weakly enhanced lesions, an adaptive image rescaling (AIR) technique was proposed. Materials and Methods Two disks containing five identical holes and five holes of different diameters were scanned using 60/100 kVp to obtain single-energy CT (SECT), dual-energy CT (DECT), and AIR images. A piece of pork was also scanned as a subclinical trial. The image quality was evaluated using image contrast and contrast-to-noise ratio (CNR). The difference of imaging performances was confirmed using student's t test. Results Total mean image contrast of AIR (0.70) reached 74.5% of that of DECT (0.94) and was higher than that of SECT (0.22) by 318.2%. Total mean CNR of AIR (5.08) was 35.5% of that of SECT (14.30) and was higher than that of DECT (2.28) by 222.8%. A similar trend was observed in the subclinical study. Conclusion The results demonstrated superior image contrast of AIR over SECT, and its higher overall image quality compared to DECT with half the exposure. Therefore, AIR seems to have the potential to improve the detectability of lesions with dedicated breast CT.

The clinical usefulness of fat suppression by chemical shift selective(CHESS) pulse in MRI (MRI에서 화학적 이동 선택(CHESS) pulse에 의한 지방소거의 임상적 유용성)

  • Han, Man-Seok;Yang, Hae-Sool;Jin, Kyung-Soo;Eo, Ik-Soo;Cho, Dong-Heon
    • The KIPS Transactions:PartB
    • /
    • v.14B no.6
    • /
    • pp.431-436
    • /
    • 2007
  • Magnetic Resonance Imaging(MRI) has chemical shift phenomenon between fat and water, and the phenomenon has influence on structure enclosed by fat. Strong signals emitted from fat often generate false artefact, which reflects the importance of fat suppression techniques. There have been a number of researches on fat suppression techniques, but using fat suppression method alone in MRI can cause difficultproblems in diagnosis. This paper aims to study a fat suppression method by Chemical Shift Selective saturation(CHESS). This research describes the theoretical background and the experiment on water and fat phantom with MR instruments. In the experiment, CHESS pulse was designed by utilising Matlap program, and the pulse diagram was generated for the Pre-saturation process. The experiment using water and fat phantom was applied to C-spine, L-spine and Breast, and produced successful fat suppression results. This experiment has proved that the CHESSpulse fat suppression is a very helpful technique in diagnosing medical imaging. This method is a robust and useful technique for both clinical and basic investigators..(Experiment with Chungnam national university hospital G.E 1.5T MR)

Detection of Brain Metastatses Using Limited Brain MR Imaging : Usefulness of Limited Contrast-Enhanced MR Imaging in Brain Metastasis (뇌전이암 진단을 위한 제한적 뇌 자기공명영상의 유용성에 관한 연구)

  • Kwon, Sun Jung;Lee, Yun Sun;An, Jin Yong;Park, Hee Sun;Jung, Sung Soo;Kim, Ju Ock;Kim, Jin Hwan;Song, Chang Joon;Kim, Sun Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.55 no.5
    • /
    • pp.499-505
    • /
    • 2003
  • Background : The brain is a common site of a metastasis in lung cancer patients. If left untreated, the patients succumb to progressive neurological deterioration with a lower survival rate than with other metastases sites. Contrast-enhanced MR imaging in the absence of symptoms or clinical signs is not recommended for identifying a cerebral metastasis in lung cancer patients because of management effectiveness. This pilot study was performed to estimate whether or not limited brain MR imaging, which has a lower cost, could be used to replace conventional brain MR imaging. Method : Between April 1999 and March 2001, 43 patients with a primary lung cancer and the others (breast cancer, stomach cancer, colon cancer, malignant melanoma etc), who had neurological symptoms and signs, were examined using conventional brain MR imaging to examine brain metastases. The control group involved four patients who had no evidence of brain metastases the sensitivity, specificity and correlation of limited brain MR imaging were compared with conventional brain MR imaging. Results : All the 43 patients who were examined with conventional brain MR imaging showed evidence of brain metastases, whereas limited brain MR imaging indicated that 42 patients had brain metastases(sensitivity=97.67%). One patient in whom limited brain MR imaging showed no brain metastasis had a metastasis in the cerebellum, as shown by the contrast-enhanced T1 weighted axial view using conventional brain MR imaging. The conventional brain MR imaging and the limited brain MI imaging of the 4 control patients both indicated no brain metastases (specificity=100 %). The Pearson Correlation of the two groups was 0.884(Confidence Interval : 99%) observed. Conclusion : Limited brain MR imaging can detect a brain metastasis with the same accuracy. In addition, it is cost-effective (229,000 won, 180$) compared to conventional brain MR imaging(529,000 won, 480$) when patients had neurological symptoms and signs or staging.

Extracardiac Uptake of Thallium-201 during Myocardial Perfusion Imaging with Pharmaeologic Vasodilation (심근관류 스캔중에 나타난 Thallium-201의 심장외 국소적 섭취)

  • Choi, Chung-Il;Kwak, Dong-Suk;Chung, Byung-Cheon;Park, Moo-Keun;Lee, Jae-Tae;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.1
    • /
    • pp.65-71
    • /
    • 1992
  • Myocardial perfusion imaging with $^{201}Tl-chloride$ following exercise or vasodilator-induced hyperemia has been effective in detecting the presence of coronary artery disease. An increased lung uptake of thallium has been reported as a sensitive marker of severe and extensive coronary artery disease and associated with poor prognosis. Thallium has also been noted to concentrate in a variety of malignant lesions. We report 5 cases of extracardiac uptake of thallium during myocardial perfusion scan with pharmacologic vasodilation. Accumulation of thallium was found in the lesions of a breast cancer, a lung cancer, a Castleman's disease and 2 cases of thymoma. We believe that the presence of focal extracardiac uptake of thallium during myocardial perfusion scan should suggest the need for further clinical evaluation to detect the tumor and must differentiate the increased lung uptake of thallium due to left ventricular dysfunction in coronary artery disease.

  • PDF

What Is the Problem in Clinical Application of Sentinel Node Concept to Gastric Cancer Surgery?

  • Miyashiro, Isao
    • Journal of Gastric Cancer
    • /
    • v.12 no.1
    • /
    • pp.7-12
    • /
    • 2012
  • More than ten years have passed since the sentinel node (SN) concept for gastric cancer surgery was first discussed. Less invasive modified surgical approaches based on the SN concept have already been put into practice for malignant melanoma and breast cancer, however the SN concept is not yet placed in a standard position in gastric cancer surgery even after two multi-institutional prospective clinical trials, the Japan Clinical Oncology Group trial (JCOG0302) and the Japanese Society for Sentinel Node Navigation Surgery (SNNS) trial. What is the problem in the clinical application of the SN concept to gastric cancer surgery? There is no doubt that we need reliable indicator(s) to determine with certainty the absence of metastasis in the lymph nodes in order to avoid unnecessary lymphadenectomy. There are several matters of debate in performing the actual procedure, such as the type of tracer, the site of injection, how to detect and harvest, how to detect metastases of SNs, and learning period. These issues have to be addressed further to establish the most suitable procedure. Novel technologies such as indocyanine green (ICG) fluorescence imaging and one-step nucleic acid amplification (OSNA) may overcome the current difficulties. Once we know what the problems are and how to tackle them, we can pursue the goal.

A Study on the PET/CT Fusion Imaging (PET/CT 결합영상진단 검사에 관한 연구)

  • Kim, Jong Gyu
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.36 no.2
    • /
    • pp.193-198
    • /
    • 2004
  • PET/CT combines the functional information from a positron emission tomography (PET) exam with the anatomical information from a computed tomography (CT) exam into one single exam. A CT scan uses a combination of x-rays and computers to give the radiologist a non-invasive way to see inside your body. One advantage of CT is its ability to rapidly acquire two-dimensional pictures of your anatomy. Using a computer these 2-D images can be presented in 3-D for in-depth clinical evaluation. A PET scan detects changes in the cellular function - how your cells are utilizing nutrients like sugar and oxygen. Since these functional changes take place before physical changes occur, PET can provide information that enables your physician to make an early diagnosis. The PET exam pinpoints metabolic activity in cells and the CT exam provides an anatomical reference. When these two scans are fused together, your physician can view metabolic changes in the proper anatomical context of your body. PET/CT offers significant advantages including more accurate localization of functional abnormalities, and the distinction of pathological from normal physiological uptake, and improvements in monitoring treatment. A PET/CT scan allows physicians to measure the body's abnormal molecular cell activity to detect cancer (such as breast cancer, lung cancer, colorectal cancer, lymphoma, melanoma and other skin cancers), brain disorders (such as Alzheimer's disease, Parkinson's disease, and epilepsy), and heart disease (such as coronary artery disease).

  • PDF

Herlyn-Werner-Wunderlich Syndrome with Central Precocious Puberty: A Case Report

  • Han, Jeeho;Lee, Jae Man;Kim, Geon Hee;Kim, Su Jin
    • Childhood Kidney Diseases
    • /
    • v.23 no.2
    • /
    • pp.124-127
    • /
    • 2019
  • Herlyn-Werner-Wunderlich (HWW) syndrome is a rare congenital anomaly of the genitourinary tract comprising uterus didelphys, obstructed hemivagina, and ipsilateral renal agenesis. Patients with HWW syndrome usually present symptoms such as dysmenorrhea, abdominal pain, pelvic mass, and purulent vaginal discharge. If not treated at an appropriate time, complications such as infertility, endometriosis, pyosalpinx, and subsequent pelvic adhesions may occur. Here, we report a case of HWW syndrome in a 7-year-old-girl who was also diagnosed as having central precocious puberty. She was brought to the pediatric department with chief complaints of lump in her breast and vaginal discharge. When she was around 2 months old, she was confirmed to have a single kidney on ultrasonography. We checked her past medical history and diagnosed her as having HWW syndrome based on the results of imaging studies, including abdominal ultrasonography and pelvic magnetic resonance imaging. She underwent treatment with gonadotropin-releasing hormone analogue for 2 years. During 24 months of follow-up, she showed no serious problems or complications. If renal anomalies are identified immediately after birth or in infancy, further screening tests should be conducted prior to menstruation for determining congenital abnormalities of the reproductive tract and vice versa.

Retrospective Analysis of Neoadjuvant Chemotherapy for Breast Cancer in Turkish Patients

  • Duman, Berna Bozkurt;Afsar, Cigdem Usul;Gunaldi, Meral;Sahin, Berksoy;Kara, I. Oguz;Erkisi, Melek;Ercolak, Vehbi
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.8
    • /
    • pp.4119-4123
    • /
    • 2012
  • Background: Neoadjuvant systemic chemotherapy is the accepted approach for women with locally advanced breast cancer. Anthracycline- and taxane-based regimens have been extensively studied in clinical trials and consequently are widely used. In this study aimed to research the complete response (pCR) rates in different regimens for neoadjuvant setting and determine associated clinical and biological factors. Methods: This study included 63 patients diagnosed with breast carcinoma among 95 patients that had been treated with neoadjuvant chemotherapy between 2007 and 2010. TNM staging system was used for staging. The histologic response to neoadjuvant chemotherapy was characterized as a pCR when there was no evidence of residual invasive tumor in the breast or axillary lymph nodes. Biologic subclassification using estrogen receptor (ER), progesterone receptor (PR), HER2 were performed. Luminal A was defined as ER+, PR+, HER2-; Luminal B tumor was defined as ER+, PR-, HER2-; ER+, PR-, HER2+; ER-, PR+, HER2-; ER+, PR+, HER2+; HER2 like tumor ER-, PR+, HER2+; and triple negative tumor ER, PR, HER2 negative. Results: Patients median age was 54.14 (min-max: 30-75). Thirty-two patients (50.8%) were premenapousal and 31 (49.2%) were postmenapousal. Staging was performed postoperatively based on the pathology report and appropriated imaging modalities The TNM (tumor, lymph node, metastasis) system was used for clinical and pathological staging. Fifty-seven (90.5%) were invasive ductal carcinomas, 6 (9.5%) were other subtypes. Thirty nine (61.9%) were grade II and 24 (38.1%) were grade III. Seven (11.1%) patients were stage II and 56 (88.9) patients were stage III. The patients were classified for ER, PR receptor and HER2 positivity. Seventeen patients had complete response to chemotherapy. Forty patients (63.5%) were treated with dose dense regimen (cyclophosphamide 600 mg/m2 and doxorubicine 60 mg/m every two weeks than paclitaxel 175 mg/m2 every two weeks with filgrastim support) 40 patients (48%) were treated anthracycline and taxane containing regimens. Thirteen patients (76%) from 17 patients with pCR were treated with the dose dense regimen but without statistical significance (p=0.06). pCR was higher in HER2(-), ER(-), grade III, premenopausal patients. Conclusion: pCR rate was higher in the group that treated with dose dense regimen, which should thus be the selected regimen in neoadjuvant setting. Some other factors can predict pCR in Turkish patients, like grade, menopausal status, triple negativity, percentage of ER positivity, and HER2 expression.

The study of Breast Specific Gamma Imaging Protocol using Self-development Phantom (자체 제작된 팬텀을 적용한 Breast Specific Gamma Imaging 검사 프로토콜에 대한 고찰)

  • Lee, Hae-Jung;Lee, Juyoung;Lim, Kuen-Kyo;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.39-47
    • /
    • 2014
  • Purpose As breast cancer patients continue to increase every year, cases of BSGI are on the rise with a heavier reliance on it. However, BSGI protocol in hospitals was not studied enough despite it was covered by hospital's condition and recommendation of manufacturers. The objective of the study was an examination of methods to be applicable to BSGI protocols, putting the self-development phantom to use in quality assessment of the images. Materials and Methods Dilon 6800 (Dilon Technologies Inc, Newport News, USA) was used in the study and five different sizes of sphere were distinctively produced in the phantom. The study used $^{99m}TcO_4$. The cases were classified in to three categories that background radioactivity to region of interest as ratio of 2: 4: 8, They were acquired images for 5, 7, 10mins. The acquired image was set region of interest according to the size of sphere, and We analyzed quantitative and qualitative analysis. The acquired data statistically analyzed with SPSS ver.18.0. Results As the result of quantitative and qualitative analysis, count rate of each sphere in accordance with difference of injection dose showed that higher count rate as injection dose and sphere size increased (P<0.005). Count rate of each sphere in accordance with difference of acquisition time showed that higher count rate as acquisition time and sphere size increased (P<0.005). Contrast noise ratio of each sphere in accordance with difference of injection dose showed that higher contrast noise ratio as injection dose increased. Particularly, Contrast noise ratio of eight times ratio images was the highest among. Contrast noise ratio of each sphere in accordance with difference of acquisition time showed that higher contrast noise ratio as acquisition time increased. And, Contrast noise ratio of seven minute image was the highest among (P<0.005). Conclusion There was significant change of Contrast noise ratio through quantitative and qualitative analysis. Moreover, We found usefulness of phantom. If Institutions identified image through the phantom study and they made BSGI protocol, We expected to help the improvement of diagnostic value of the images.

  • PDF