• Title/Summary/Keyword: Breast image

Search Result 287, Processing Time 0.027 seconds

Correlation analysis of radiation therapy position and dose factors for left breast cancer (좌측 유방암의 방사선치료 자세와 선량인자의 상관관계 분석)

  • Jeon, Jaewan;Park, Cheolwoo;Hong, Jongsu;Jin, Seongjin;Kang, Junghun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.1
    • /
    • pp.37-48
    • /
    • 2017
  • Purpose: The most basic conditions of radiation therapy is to prevent unnecessary exposure of normal tissue. The risk factors that are important o evaluate the dose emitted to the lung and heart from radiation therapy for breast cancer. Therefore, comparing the dose factors of a normal tissue according to the radion treatment position and Seeking an effective radiation treatment for breast cancer through the analysis of the correlation relationship. Materials and Methods: Computed tomography was conducted among 30 patients with left breast cancer in supine and prone position. Eclipse Treatment Planning System (Ver.11) was established by computerized treatment planning. Using the DVH compared the incident dose to normal tissue by position. Based on the result, Using the SPSS (ver.18) analyzed the dose in each normal tissue factors and Through the correlation analysis between variables, independent sample test examined the association. Finally The HI, CI value were compared Using the MIRADA RTx (ver. ad 1.6) in the supine, prone position Results: The results of computerized treatment planning of breast cancer in the supine position were V20, $16.5{\pm}2.6%$ and V30, $13.8{\pm}2.2%$ and Mean dose, $779.1{\pm}135.9cGy$ (absolute value). In the prone position it showed in the order $3.1{\pm}2.2%$, $1.8{\pm}1.7%$, $241.4{\pm}138.3cGy$. The prone position showed overall a lower dose. The average radiation dose 537.7 cGy less was exposured. In the case of heart, it showed that V30, $8.1{\pm}2.6%$ and $5.1{\pm}2.5%$, Mean dose, $594.9{\pm}225.3$ and $408{\pm}183.6cGy$ in the order supine, prone position. Results of statistical analysis, Cronbach's Alpha value of reliability analysis index is 0.563. The results of the correlation analysis between variables, position and dose factors of lung is about 0.89 or more, Which means a high correlation. For the heart, on the other hand it is less correlated to V30 (0.488), mean dose (0.418). Finally The results of independent samples t-test, position and dose factors of lung and heart were significantly higher in both the confidence level of 99 %. Conclusion: Radiation therapy is currently being developed state-of-the-art linear accelerator and a variety of treatment plan technology. The basic premise of the development think normal tissue protection around PTV. Of course, if you treat a breast cancer patient is in the prone position it take a lot of time and reproducibility of set-up problems. Nevertheless, As shown in the experiment results it is possible to reduce the dose to enter the lungs and the heart from the prone position. In conclusion, if a sufficient treatment time in the prone position and place correct confirmation will be more effective when the radiation treatment to patient.

  • PDF

Evaluation of Ovary Dose of Childbearing age Woman with Breast cancer in Radiation therapy (가임기 여성의 방사선 치료 시 난소 선량 평가)

  • Park, Sung Jun;Lee, Yeong Cheol;Kim, Seon Myeong;Kim, Young Bum
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.145-153
    • /
    • 2021
  • Purpose: The purpose of this study is to evaluate the ovarian dose during radiation therapy for breast cancer in women of childbearing age through an experiment. The ovarian dose is evaluated by comparing and analyzing between the calculated dose in the treatment planning system according to the treatment technique and the measured dose using a thermoluminescence dosimeter (TLD). The clinical usefulness of lead (Pb) apron is investigated through dose analysis according to whether or not it is used. Materials and Methods: Rando humanoid phantom was used for measurement, and wedge filter radiation therapy, 3D conformal radiation therapy, and intensity modulated radiation therapy were used as treatment techniques. A treatment plan was established so that 95% of the prescribed dose could be delivered to the right breast of the Rando humanoid phantom 3D image obtained using the CT simulator. TLD was inserted into the surface and depth of the virtual ovary of the Rando hunmanoid phantom and irradiated with radiation. The measurement location was the center of treatment and the point moved 2 cm to the opposite breast from the center of the Rando hunmanoid phantom, 5cm, 10cm, 12.5cm, 15cm, 17.5cm, 20cm from the boundary of the right breast to the center of treatment and downward, and the surface and depth of the right ovary. Measurements were made at a total of 9 central points. In the dose comparison of treatment planning systems, two wedge filter treatment techniques, three-dimensional conformal radiotherapy, and intensity-modulated radiation therapy were established and compared. Treatments were compared, and dose measurements according to the use of lead apron were compared and analyzed in intensity-modulated radiation therapy. The measured value was calculated by averaging three TLD values for each point and converting using the TLD calibration value, which was calculated as the point dose mean value. In order to compare the treatment plan value with the actual measured value, the absolute dose value was measured and compared at each point (%Diff). Results: At Point A, the center of treatment, a maximum of 201.7cGy was obtained in the treatment planning system, and a maximum of 200.6cGy was obtained in the TLD. In all treatment planning systems, 0cGy was calculated from Point G, which is a point 17.5cm downward from the breast interface. As a result of TLD, a maximum of 2.6cGy was obtained at Point G, and a maximum of 0.9cGy was obtained at Point J, which is the ovarian dose, and the absolute dose was 0.3%~1.3%. The difference in dose according to the use of lead aprons was from a maximum of 2.1cGy to a minimum of 0.1cGy, and the %Diff value was 0.1%~1.1%. Conclusion: In the treatment planning system, the difference in dose according to the three treatment plans did not show a significant difference from 0.85% to 2.45%. In the ovary, the difference between the Rando humanoid phantom's treatment planning system and the actual measured dose was within 0.9%, and the actual measured dose was slightly higher. This did not accurately reflect the effect of scattered radiation in the treatment planning system, and it is thought that the dose of scattered radiation and the dose taken by CBCT with TLD inserted were reflected in the actual measurement. In dosimetry according to the with or without a lead apron, when a lead apron was used, the closer the distance from the treatment range, the more effective the shielding was. Although it is not clinically appropriate for pregnancy or artificial insemination during radiotherapy, the dose irradiated to the ovaries during treatment is not expected to significantly affect the reproductive function of women of childbearing age after radiotherapy. However, since women of childbearing age have constant anxiety, it is thought that psychological stability can be promoted by presenting the data from this study.

Comparison of Tc-99m-Tetrofosmin and Tc-99m-MIBI Scintimammography in Differential Diagnosis of Breast Mass (유방종양의 감별진단에서 Tc-99m-Tetrofosmin과 Tc-99m-MIBI 유방신티그라피의 비교)

  • Park, Jung-Mi;Choi, Joon-Young;Lee, Kyung-Han;Choi, Yong;Choe, Yearn-Seong;Kim, Sang-Eun;Kim, Byung-Tae;Nam, Seok-Jin;Yang, Jeong-Hyun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.5
    • /
    • pp.393-402
    • /
    • 2000
  • Purpose: Tc-99m-MIBI (MIBI) and Tc-99m-Tetrofosmin (TF) are commonly used for scintimammog (SMM). We compared the diagnostic ability of SMM using Tc-99m-MIBI and Tc-99m-TF for the diagnosis of breast mass. Materials and Methods: The study subjects were comprised of 123 breast lesior 86 normal breasts of 114 patients who underwent SMM. Bilateral prone images and anterior supine images obtained at 5 minutes and 1 or 3 hours after intravenous injection of 740 MBq of either MIBI or TF. of tumors were not significantly different between the MIBI and TF groups. First, two observers read the SMM without clinical information (1st interpretation), then read again with information about location (2nd interpretation). Sensitivity and specificity of each radiopharmaceutical for the diagnosis of cancer were evaluated in terms of image acquisition time, tumor size, and location. Results: The SMM a good agreement between two observers for 1st and 2nd interpretation, except for TF SMM at 3 hr. first interpretation, the sensitivities at 5 min, 1 hr, and 3 hr were not significantly different between MIBI TF SMM (81.6%, 80.0%, 60.9% in MIBI vs. 88.9%, 80.6%, 42.9% in TF), although the sensitivities of images were significantly lower than 5 min images in both MIBI and TF SMM. The specificity of TF at was superior to that of MIBI (81.5%, 90.0%, 82.9% in MIBI vs. 96.7%, 100%, 90.0% in TF, p<0.01 MIBI TF at 5 min). For the second interpretation with information of mass location, the sensitivities at 3 hr were significantly lower than 5 min images (86.8%, 86.7%, 78.3% in MIBI vs. 88.9%, 93.5%, 57.1% between MIBI and TF SMM. However, there was no significant difference in the specificity (60.0%, 75.0% for MIBI vs. 86.7%, 100%, 100% for TF). MIBI and TF SMM showed lower sensitivities for the with less than 1 cm than tumors with more than 1 cm. However, the location of tumors did not sensitivity and specificity between MIBI and TF SMM. Conclusion: The ability for the differential of breast tumor is similar between MIBI and TF SMM, and delayed image is not necessary. TF may be than MIBI considering the specificity of SMM without clinical information and labeling convenience.

  • PDF

The Effects of Imagery Therapy on Coping Mechanism and Type C Personality in the Women with Mastectomy (심상치료가 유방 절제 여성의 성격특성과 대처전략에 미치는 효과)

  • Kim, Eun-Sim;Pai, Hang-Ja
    • Asian Oncology Nursing
    • /
    • v.3 no.2
    • /
    • pp.103-111
    • /
    • 2003
  • The purpose of this study was to identify the effect of imagery therapy on "coping mechanism and type C personality of the women with mastectomy. To achieve this purpose, 2 hours sessions of imagery therapy were given to the patients with breast cancer twice a week for 6 weeks. The period of data collection was from July, 7th to August, 12th 2002. The participants were 30 patients, 15 experimental group, 15 control group who were treated at the G University hospital in J City. This study was designed using a quasi-experimental approach with non-equivalent Pre test-Post test Design. The themes for the Imagery Therapy Program were composed of Leuner's(1969) 12 Imagery Themes: flower, green-field, stream, mountain, house, woods, significant figures, rose, lion, ideal self-image, cave and volcano. The data were analyzed with ${\chi}2-test$ and MANOVA using the SPSS program. The course of image change of the 12 imagery themes was analyzed by content analysis. The results of this study are as follows: First Hypothesis, 'The score of type C personality in the women with mastectomy who received imagery therapy will be significantly lower than that of the control group' was supported(p<.05). Second Hypothesis, 'The score of coping mechanism' in the women with mastectomy who received imagery therapy will be significantly higher than that of the control group' was rejected. In conclusion, imagery therapy is suggested as an effective nursing intervention to change type C personality of the women with mastectomy, but not effective to improve coping mechanism. Therefore, the program for the women with mastectomy should be developed to change their coping mechanism, method of problem solving and Quality of life.

  • PDF

Validation of Electrical Impedance Tomography Qualitative and Quantitative Values and Comparison of the Numeric Pain Distress Score against Mammography

  • Juliana, Norsham;Shahar, Suzana;Chelliah, Kanaga Kumari;Ghazali, Ahmad Rohi;Osman, Fazilah;Sahar, Mohd Azmani
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.14
    • /
    • pp.5759-5765
    • /
    • 2014
  • Electrical impedance tomography (EIT) is a potential supplement for mammogram screening. This study aimed to evaluate and feasibility of EIT as opposed to mammography and to determine pain perception with both imaging methods. Women undergoing screening mammography at the Radiology Department of National University of Malaysia Medical Centre were randomly selected for EIT imaging. All women were requested to give a pain score after each imaging session. Two independent raters were chosen to define the image findings of EIT. A total of 164 women in the age range from 40 to 65-year-old participated and were divided into two groups; normal and abnormal. EIT sensitivity and specificity for rater 1 were 69.4% and 63.3, whereas for rater 2 they were 55.3% and 57.0% respectively. The reliability for each rater ranged between good to very good (p<0.05). Quantitative values of EIT showed there were significant differences in all values between groups (ANCOVA, p<0.05). Interestingly, EIT scored a median pain score of $1.51{\pm}0.75$ whereas mammography scored $4.15{\pm}0.87$ (Mann Whitney U test, p<0.05). From these quantitative values, EIT has the potential as a health discriminating index. Its ability to replace image findings from mammography needs further investigation.

Types and Expression Characteristics of Model Poses in Modern Fashion Photographs -Focused on Patrick Demarchelier's Fashion Photos-

  • Kim, Young-Min;Kim, Jang-Hyeon;Kim, Young-Sam
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.38 no.5
    • /
    • pp.769-782
    • /
    • 2014
  • This study considers the correlation between model pose and clothes in Patrick Demarchelier's fashion photos as well as expression characteristics. The conclusions of the study are as follows. The type of model pose in Patrick Demarchelier's fashion photos can be categorized into five types: maximized type of upper and lower body part, minimized type of upper and lower body part, maximized type of upper body and minimized type of lower body part, minimized type of upper body and maximized type of lower body part, basic type of upper and lower body part. In case of having examined the correlation between body movement and costume, the clothes in the model pose included in the maximization of the body were formed mainstream by silhouette, which was formed by decorative elements or full drapery. In the model poses included in the reduction of the body, the costume tended to expose many parts of the body to provide a simple or structural silhouette form. The costume was expressed in colorful form and poses assumed without body movements. The expression characteristics of the model poses in Patrick Demarchelier's fashion photos were sensuality, dynamicity, and simplicity. First, sensuality was expressed as feminine sensuality accompanying an erotic mood by naturally emphasizing a woman's breast or leg by reducing the body. Second, dynamicity provided a vividness to the image as if directly living and moving by highlighting the rhythmic aspect of the body. Simplicity aroused the effect of paying attention to clothes or other incidental elements rather than the image expressed by the body of a model by excluding body movement.

Use of Weight-control or Health Functional Foods, Associated Weight-control Behavior and Perception among University Students in Cheongju (청주지역 일부 대학생의 체중조절 식품 및 건강기능식품 사용 실태와 관련 인식 연구)

  • Kim, Gayong;Pae, Munkyong
    • Korean Journal of Community Nutrition
    • /
    • v.26 no.1
    • /
    • pp.23-36
    • /
    • 2021
  • Objectives: This study sought to assess the prevalence and duration of weight-control or health functional food use, associated weight-control behavior, perception, and knowledge among university students. Methods: The subjects were 442 university students in Cheonju, Korea, and data was collected by a self-administered questionnaire. Both χ2 and t-tests were conducted for categorical and mean comparisons. Results: An estimated 62.7% (female 69.0%, male 54.8%) had ever attempted weight-control. Among these, an estimated 59.2% of females and 38.9% of males had used weight-control or health functional foods with significant gender difference. The weight-control foods commonly used included chicken breast, protein powder, low-fat milk and soymilk, and meal replacement drinks, while garcinia cambogia extract and green tea extract were frequently used as health functional foods. One of 10 (10.3%) consumers of weight-control foods reported ≥ 7 months use, with less frequent long-term consumption of health functional foods (4.2%). The average degree of satisfaction was 3.24 ± 0.92 for weight-control foods and 2.72 ± 0.97 for health functional foods on a 5-point scale, meaning 'slightly satisfied' and 'slightly dissatisfied', respectively. Females or students with an experience of weight-control reported poorer perceptions of their health and body image as well as a higher need for weight control. Besides, both male and female subjects felt a high need for correct information regarding weight-control methods. Conclusions: Our results provide a better understanding of the characteristics associated with the use of weight-control or health functional foods among university students and will be useful in developing a nutrition education program by incorporating correct body image, knowledge, and practical yet desirable practices for weight control.

Experiments of Individual Tree and Crown Width Extraction by Band Combination Using Monthly Drone Images (월별 드론 영상을 이용한 밴드 조합에 따른 수목 개체 및 수관폭 추출 실험)

  • Lim, Ye Seul;Eo, Yang Dam;Jeon, Min Cheol;Lee, Mi Hee;Pyeon, Mu Wook
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.24 no.4
    • /
    • pp.67-74
    • /
    • 2016
  • Drone images with high spatial resolution are emerging as an alternative to previous studies with extraction limits in high density forests. Individual tree in the dense forests were extracted from drone images. To detect the individual tree extracted through the image segmentation process, the image segmentation results were compared between the combination of DSM and all R,G,B band and the combination of DSM and R,G,B band separately. The changes in the tree density of a deciduous forest was experimented by time and image. Especially the image of May when the forests are dense, among the images of March, April, May, the individual tree extraction rate based on the trees surveyed on the site was 50%. The analysis results of the width of crown showed that the RMSE was less than 1.5m, which was the best result. For extraction of the experimental area, the two sizes of medium and small trees were extracted, and the extraction accuracy of the small trees was higher. The forest tree volume and forest biomass could be estimated if the tree height is extracted based on the above data and the DBH(diameter at breast height) is estimated using the relational expression between crown width and DBH.

A Study on Compression Paddle Materials to Reduce Radiation Exposure Dose During Mammography; PC and PMMA and Carbon (유방촬영 시 피폭선량을 줄이기 위한 압박대 재질의 PC, PMMA, Carbon에 대한 연구)

  • Hong, Dong-Hee;Jung, Hong-Ryang
    • Journal of radiological science and technology
    • /
    • v.38 no.2
    • /
    • pp.81-87
    • /
    • 2015
  • This study was designed the band material in order to reduce the exposure pressure of the breast and the material was measured of Radiolucent and radiation properties with a radiation materials of PC, PMMA, Carbon. Also the image quality by image analysis to obtain the following results are below: Unfors Xi dosimetry using radiation transmittance when the results of 8.353mGy is measured after removal of the cuff, the PC 6.308mGy, PMMA 6.223mGy, Carbon 7.218mGy were measured respectively. Semi-layer PC 0.375mmAl, PMMA 0.370mmAl, with Carbon 0.360mmAl Carbon, PC, PMMA was higher radiation properties and transparency in order. InLight / OSL NanoDotTM dosimeter was used in the cuff and then removed by placing the dosimeter measured results center on 1.143mGy, at the edge 12.56mGy, on the central PC 8.990mGy, at the edge 10.291mGy, PMMA center on 8.391mGy, the edge 9.654mGy, on Carbon center 9.581mGy, 11.313 mGy were measured at the edge of Carbon, PC, PMMA showed a high permeability in order. Image Pixel average J is then removed from the cuff 976.655, PC 831.032, PMMA 819.069, Carbon 897.118 Carbon, PC, PMMA was measured by high order.

Variation of Image Quality and Dose by Applying Multi-Leaf Collimator for Digital Mammography (디지털 유방촬영장치에서 다엽 조리개 적용으로 인한 화질과 선량의 변화)

  • Kwon, Soon Mu;Kim, Boo Soon;Park, Hyung Jun;Kang, Yeong Han
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.7
    • /
    • pp.535-540
    • /
    • 2015
  • Collimator has important functions with control primary X-ray that decrease radiation exposure dose for patients and reduce scatter ray and make better quality of image. But there are no regulations for X-ray mammography device of collimator, so widely used device adopt rectangularly controlled collimator. Though digital X-ray mammography device expand supply recently, rectangularly controlled collimator of film/screen mode still used. After searching for real condition of beam field with digital mammography, we made a multi-leaf collimator which is able to adjust the beam field in accordance with size and shape of breast, and we measuring up the transitions of image quality, average glandular dose(AGD) and, Dose area product(DAP). There are no significant differences between rectangularly controlled collimator and multi-leaf collimator, and DAP value decreased by 50.72%. As conclusion, there needs to expand the use of multi-leaf collimator for optimum adoption of beam field in digital mammography, and also need to develop an automatic regulation of beam field for reduce of exposure dose to patients.