The evaluation of contralateral breast's dose and shielding efficiency by breast size about breast implant patient for radiation therapy (인공 유방 확대술을 받은 환자의 유방암 치료 시 크기에 따른 반대 측 유방의 피폭 선량 및 차폐 효율 평가)

  • Kim, Jong Wook;Woo, Heon;Jeong, Hyeon Hak;Kim, Kyeong Ah;Kim, Chan Yong;Yoo, Suk Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.329-336
    • /
    • 2014
  • Purpose : To evaluate the dose on a contralateral breast and the usefulness of shielding according to the distance between the contralateral breast and the side of the beam by breast size when patients who got breast implant receive radiation therapy. Materials and Methods : We equipped 200 cc, 300 cc, 400 cc, and 500 cc breast model on the human phantom (Rando-phantom), acquired CT images (philips 16channel, Netherlands) and established the radiation treatment plan, 180 cGy per day on the left breast (EclipseTM ver10.0.42, Varian Medical Systems, USA) by size. We set up each points, A, B, C, and D on the right(contralateral) breast model for measurement by size and by the distance from the beam and attached MOSFET at each points. The 6 MV, 10 MV and 15 MV X-ray were irradiated to the left(target) breast model and we measured exposure dose of contralateral breast model using MOSFET. Also, at the same condition, we acquired the dose value after shielding using only Pb 2 mm and bolus 3 mm under the Pb 2 mm together. Results : As the breast model is bigger from 200 cc to 500 cc, The surface of the contralateral breast is closer to the beam. As a result, from 200 cc to 500 cc, on 180 cGy basis, the measurement value of the scattered ray inclined by 3.22 ~ 4.17% at A point, 4.06 ~ 6.22% at B point, 0.4~0.5% at C point, and was under 0.4% at D point. As the X-ray energy is higher, from 6 MV to 15 MV, on 180 cGy basis, the measurement value of the scattered ray inclined by 4.06~5% at A point, 2.85~4.94% at B point, 0.74~1.65% at C point, and was under 0.4% at D point. As using Pb 2 mm for shield, scattered ray declined by average 9.74% at A and B point, 2.8% at C point, and is under 1% at D point. As using Pb 2 mm and bolus together for shield, scattered ray declined by average 9.76% at A and B point, 2.2% at C point, and is under 1% at D point. Conclusion : Commonly, in case of patients who got breast implant, there is a distance difference by breast size between the contralateral breast and the side of beam. As the distance is closer to the beam, the scattered ray inclined. At the same size of the breast, as the X-ray energy is higher, the exposure dose by scattered ray tends to incline. As a result, as low as possible energy wihtin the plan dose is good for reducing the exposure dose.

Anti-cancer Effects by Saussurea lappa Clarke in Highly-metastatic MDA-MB-231 Breast Cancer Cells (전이성 유방암 세포주에 대한 당목향의 항암효과탐색)

  • Kim, Chi-Hong;Choi, Youn-Kyung;Kim, Woo-Young;Shin, Yong-Cheol;Ko, Seong-Gyu
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.25 no.6
    • /
    • pp.968-974
    • /
    • 2011
  • Saussurea lappa Clarke is a well-known transitional medicine in Asia including Korea, China and Japan. It has been reported that Clarke has diverse effects such as anti-viral, anti-inflammatory, anti-cancer in human gastric cells and human prostate cancer cells. However, the anti-cancer effects and the mechanism of actions of Saussurea lappa Clarke are still unknown in breast cancer. In this study, we observed that Saussurea lappa Clarke inhibits the cell growth in a dose- and time-dependent manner in highly-metastatic MDA-MB-231 breast cancer cells. In order to examine whether Saussurea lappa Clarke suppresses cell growth inducing apoptosis cell death or cell cycle arrest, we analyzed DNA contents and cell cycle distribution using a flow cytometer and western blotting in MDA-MB-231 cells. We suggest that Saussurea lappa Clarke dose not induced apoptosis and induced G2/M phase cell cycle arrest. Moreover, Saussurea lappa Clarke also decreased the expression level of metastasis-angiogenesis releated protein such as VEGF. However, dose not changed the expression level of metastasis related protease MMP-1 in highly-metastatic MDA-MB-231 breast cancer cells. Therefore, Saussurea lappa Clarke might be good and useful chemotherapy agent highly-metastatic breast cancer patients.

Liver dose reduction by deep inspiration breath hold technique in right-sided breast irradiation

  • Haji, Gunel;Nabizade, Ulviye;Kazimov, Kamal;Guliyeva, Naile;Isayev, Isa
    • Radiation Oncology Journal
    • /
    • v.37 no.4
    • /
    • pp.254-258
    • /
    • 2019
  • Purpose: Deep inspiration breath hold (DIBH) is a well-established technique that enables efficient cardiac sparing in patients with left-sided breast cancer. The aim of the current study was to determine if DIBH is effective for reducing radiation exposure of of liver and other organs at risk in right breast radiotherapy (RT). Materials and Methods: Twenty patients with right-sided breast cancer were enrolled in this study. Three-dimensional conformal RT plans were generated for each patient, with two different computed tomography scans of free breathing (FB) and DIBH. Nodes were contoured according to the Radiation Therapy Oncology Group contouring guidelines. Dose-volume histograms for the target volume coverage and organs at risk were evaluated and analyzed. Results: DIBH plans showed significant reduction in mean liver dose (5.59 ± 2.07 Gy vs. 2.54 ± 1.40 Gy; p = 0.0003), V20Gy (148.38 ± 73.05 vs. 64.19 ± 51.07 mL; p = 0.0003) and V10Gy (195.34 ± 93.57 vs. 89.81 ± 57.28 mL; p = 0.0003) volumes compared with FB plans. Right lung doses were also significantly reduced in DIBH plans. Heart and left lung doses showed small but statistically significant improvement with application of the DIBH technique. Conclusion: We report that the use of DIBH for right-sided breast cancer significantly reduces the radiation doses to the liver, lungs, and heart.

Effect of [6]-Gingerol on Bcl-2 and Bax Expression in MDA-MB-231 Human Breast Cancer Cell Line ([6]-Gingerol이 인체 유방암세포 MDA-MB-231에서 Bcl-2와 Bax 발현에 미치는 영향)

  • Seo, Eun-Young;Kim, Woo-Kyung
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.35 no.6
    • /
    • pp.671-676
    • /
    • 2006
  • We investigated the effect of gingerol (Zingiber officinale Roscoe, Zingiberaceae) on Bcl-2 and Bax expression in MDA-MB-231 human breast cell lines. The oleoresin from rhizomes of ginger contains [6]-gingerol (1-[4'-hydroxy-3'-methoxyphenyl]-5-hydroxy-3-decanone). We previously reported that [6]-gingerol inhibits cell proliferation in MDA-MB-231 human breast cancer cell lines. In this study, we examined protein and mRNA expression associated with cell apoptosis in MDA-MB-231 human breast cancer cell lines. We cultured MDA-MB-231 cells in presence of various concentrations 0, 2.5, 5 and $10\;{\mu}M$ of [6]-gingerol. Bcl-2 protein and its mRNA levels were decreased dose-dependently in cells treated with [6]-gingerol, but Bax protein and its mRNA levels were unchanged by [6]-gingerol treatment. Bcl-2/Bax ratio was decreased in a dose dependent manner treated with [6]-gingerol. Caspase-3 activity was significantly increased dose-dependently in cell treated with [6]-gingerol (p<0.05). In conclusion, we have shown that [6]-gingerol induces apoptosis in MDA-MB-231 human breast cancer cell lines.

Feasibility Study of Docetaxel and Cyclophosphamide Six- Cycle Therapy as Adjuvant Chemotherapy for Japanese Human Epidermal Growth Factor Receptor 2-Negative Breast Cancer Patients

  • Abe, Hajime;Mori, Tsuyoshi;Kawai, Yuki;Tomida, Kaori;Kubota, Yoshihiro;Umeda, Tomoko;Tani, Tohru
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.8
    • /
    • pp.4835-4838
    • /
    • 2013
  • Background: We compared treatment completion rates and safety of docetaxel and cyclophosphamide sixcycle therapy (TC6) with docetaxel followed by 5FU, epirubicin and cyclophosphamide (T-FEC) therapy in Japanese patients with human epidermal growth factor receptor 2 (HER2)-negative breast cancer. Materials and Methods: We administered TC6 q3w or T-FEC q3w to HER2-negative breast cancer patients. The primary endpoint of this trial was toxicity. As second endpoints, the treatment completion rate and relative dose intensity were evaluated. Results: The TC6 and T-FEC group consisted of 22 and 21 patients, respectively. Concerning hematological toxicity, grade 3 or higher adverse reactions included neutropenia and febrile neutropenia. As non-hematological adverse events, exanthema and peripheral neuropathy were frequently reported in the TC6 group, whereas more patients of the T-FEC group reported nausea and vomiting. In TC6, the treatment completion rate was 86.4% and the relative dose intensity of docetaxel was 93.2%. In T-FEC, the values were 95.2% and 98.9%, respectively. Conclusions: These results suggest that TC6 is tolerable in Japanese, and that this regimen can also be performed in outpatient clinics. However, with the TC6 regimen, the compliance was slightly lower than with the T-FEC regimen, and supportive therapy needs to be managed appropriately.

Dose-Dependent Associations between Wine Drinking and Breast Cancer Risk - Meta-Analysis Findings

  • Chen, Jia-Yan;Zhu, Hong-Cheng;Guo, Qing;Shu, Zheng;Bao, Xu-Hui;Sun, Feng;Qin, Qin;Yang, Xi;Zhang, Chi;Cheng, Hong-Yan;Sun, Xin-Chen
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.3
    • /
    • pp.1221-1233
    • /
    • 2016
  • Purpose: To investigate any potential association between wine and breast cancer risk. Materials and Methods: We quantitatively assessed associations by conducting a meta-analysis based on evidence from observational studies. In May 2014, we performed electronic searches in PubMed, EmBase and the Cochrane Library to identify studies examining the effect of wine drinking on breast cancer incidence. The relative risk (RR) or odds ratio (OR) were used to measure any such association. Results: The analysis was further stratified by confounding factors that could influence the results. A total of twenty-six studies (eight case-control and eighteen cohort studies) involving 21,149 cases were included in our meta-analysis. Our study demonstrated that wine drinking was associated with breast cancer risk. A 36% increase in breast cancer risk was observed across overall studies based on the highest versus lowest model, with a combined RR of 1.0059 (95%CI 0.97-1.05) in dose-response analysis. However, 5 g/d ethanol from wine seemed to have protective value from our non-linear model. Conclusions: Our findings indicate that wine drinking is associated with breast cancer risk in a dose-dependent manner. High consumption of wine contributes to breast cancer risk with protection exerted by low doses. Further investigations are needed for clarification.

Relationship of Compressed Breast Thickness and Average Glandular Dose According to Focus/Filter (초점/필터에 따른 유방 압박 두께와 평균 유선 선량의 관계)

  • Lee, In-Ja
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.261-270
    • /
    • 2009
  • The study examined the relationship between the compressed breast thickness and Average Glandular Dose (AGD) among 1,969 outpatients who went through breast X-ray in a university hospital for 10 months from July 1st, 2007 to April 30th, 2008. Then it analyzed the result acquired from 3,900 cases of Cranio-Caudal (CC) view, especially, when the breasts were compressed (13-15daN). The following is the conclusion driven from the relationship analysis. 1. The subjects aged in 40s and 50s were 2,679 out of 3,900 cases and this figure was 68.69% in all. 2. In terms of distribution depending on focus/filter, 41.0% was Mo/Mo, 34.8% was Mo/Rh, and 24.2% was Rh/Rh. 3. In terms of compressed breast thickness depending on focus/filter, the average thickness was 26.91 mm at Mo/Mo, 38.84 mm at Mo/Rh, and 48.80 mm at Rh/Rh. The average thickness of the entire cases was shown to be 36.27 mm. 4. AGD depending on focus/filter was 1.27 mGy at Mo/Mo, 1.55 mGy at Mo/Rh, and 1.42 mGy at Rh/Rh. The average glandular dose of the entire cases was shown to be 1.43 mGy. 5. The relationship of AGD depending on compressed breast thickness at Mo/Mo was y=0.0318x + 0.470 while it was y=0.0206x + 0.709 at Mo/Rh and y=0.0248x + 0.335 at Mo/Rh. It was highly influenced by the compressed breast thickness, however, more variation was detected at Mo/Mo depending on breast thickness.

  • PDF

Improved Breast Irradiation Techniques Using Multistatic Fields or Three Dimensional Universal Compensators (Multistatic Field또는 3차원 공용보상체를 사용한 유방의 방사선 조사법의 평가)

  • Han Youngyih;Cho Jae Ho;Park Hee Chul;Chu Sung Sil;Suh Chang-Ok
    • Radiation Oncology Journal
    • /
    • v.20 no.1
    • /
    • pp.24-33
    • /
    • 2002
  • Purpose : In order to improve dose homogeneity and to reduce acute toxicity in tangential whole breast radiotherapy, we evaluated two treatment techniques using multiple static fields or universal compensators. Materials and Methods : 1) Multistatic field technique : Using a three dimensional radiation treatment planning system, Adac Pinnacle 4.0, we accomplished a conventional wedged tangential plan. Examining the isodose distributions, a third field which blocked overdose regions was designed and an opposing field was created by using an automatic function of RTPS. Weighting of the beams was tuned until an ideal dose distribution was obtained. Another pair of beams were added when the dose homogeneity was not satisfactory. 2) Universal compensator technique : The breast shapes and sizes were obtained from the CT images of 20 patients who received whole breast radiation therapy at our institution. The data obtained were averaged and a pair of universal physical compensators were designed for the averaged data. DII (Dose Inhomogeneity Index : percentage volume of PTV outside $95\~105\%$ of the prescribed dose) $D_{max}$ (the maximum point dose in the PTV) and isodose distributions for each technique were compared. Results : The multistatic field technique was found to be superior to the conventional technique, reducing the mean value of DII by $14.6\%$ (p value<0.000) and the $D_{max}$ by $4.7\%$ (p value<0.000). The universal compensator was not significantly superior to the conventional technique since it decreased $D_{max}$ by $0.3\%$ (p value=0.867) and reduced DII by $3.7\%$ (p value=0.260). However, it decreased the value of DII by maximum $18\%$ when patients' breast shapes fitted in with the compensator geometry. Conclusion : The multistatic field technique is effective for improving dose homogeneity for whole breast radiation therapy and is applicable to all patients, whereas the use of universal compensators is effective only in patients whose breast shapes fit inwith the universal compensator geometry, and thus has limited applicability.

Evaluation of Ovary Dose of Childbearing age Woman with Breast cancer in Radiation therapy (가임기 여성의 방사선 치료 시 난소 선량 평가)

  • Park, Sung Jun;Lee, Yeong Cheol;Kim, Seon Myeong;Kim, Young Bum
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.145-153
    • /
    • 2021
  • Purpose: The purpose of this study is to evaluate the ovarian dose during radiation therapy for breast cancer in women of childbearing age through an experiment. The ovarian dose is evaluated by comparing and analyzing between the calculated dose in the treatment planning system according to the treatment technique and the measured dose using a thermoluminescence dosimeter (TLD). The clinical usefulness of lead (Pb) apron is investigated through dose analysis according to whether or not it is used. Materials and Methods: Rando humanoid phantom was used for measurement, and wedge filter radiation therapy, 3D conformal radiation therapy, and intensity modulated radiation therapy were used as treatment techniques. A treatment plan was established so that 95% of the prescribed dose could be delivered to the right breast of the Rando humanoid phantom 3D image obtained using the CT simulator. TLD was inserted into the surface and depth of the virtual ovary of the Rando hunmanoid phantom and irradiated with radiation. The measurement location was the center of treatment and the point moved 2 cm to the opposite breast from the center of the Rando hunmanoid phantom, 5cm, 10cm, 12.5cm, 15cm, 17.5cm, 20cm from the boundary of the right breast to the center of treatment and downward, and the surface and depth of the right ovary. Measurements were made at a total of 9 central points. In the dose comparison of treatment planning systems, two wedge filter treatment techniques, three-dimensional conformal radiotherapy, and intensity-modulated radiation therapy were established and compared. Treatments were compared, and dose measurements according to the use of lead apron were compared and analyzed in intensity-modulated radiation therapy. The measured value was calculated by averaging three TLD values for each point and converting using the TLD calibration value, which was calculated as the point dose mean value. In order to compare the treatment plan value with the actual measured value, the absolute dose value was measured and compared at each point (%Diff). Results: At Point A, the center of treatment, a maximum of 201.7cGy was obtained in the treatment planning system, and a maximum of 200.6cGy was obtained in the TLD. In all treatment planning systems, 0cGy was calculated from Point G, which is a point 17.5cm downward from the breast interface. As a result of TLD, a maximum of 2.6cGy was obtained at Point G, and a maximum of 0.9cGy was obtained at Point J, which is the ovarian dose, and the absolute dose was 0.3%~1.3%. The difference in dose according to the use of lead aprons was from a maximum of 2.1cGy to a minimum of 0.1cGy, and the %Diff value was 0.1%~1.1%. Conclusion: In the treatment planning system, the difference in dose according to the three treatment plans did not show a significant difference from 0.85% to 2.45%. In the ovary, the difference between the Rando humanoid phantom's treatment planning system and the actual measured dose was within 0.9%, and the actual measured dose was slightly higher. This did not accurately reflect the effect of scattered radiation in the treatment planning system, and it is thought that the dose of scattered radiation and the dose taken by CBCT with TLD inserted were reflected in the actual measurement. In dosimetry according to the with or without a lead apron, when a lead apron was used, the closer the distance from the treatment range, the more effective the shielding was. Although it is not clinically appropriate for pregnancy or artificial insemination during radiotherapy, the dose irradiated to the ovaries during treatment is not expected to significantly affect the reproductive function of women of childbearing age after radiotherapy. However, since women of childbearing age have constant anxiety, it is thought that psychological stability can be promoted by presenting the data from this study.

Monitoring on Dose Index Analyzed in the Mammography (유방촬영검사에서 선량지표분석에 대한 모니터링)

  • Cho, Ji-Hwan;Lee, Hyo-Yeong;Im, In-Chul
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.7
    • /
    • pp.477-482
    • /
    • 2016
  • This study is tried to determine whether the management of medical radiation is well handled by comparison the guidelines of KFDA(korea food & drug administration) with analysis of dose indicator in mammography. As a method, it is analysed that kVp, exposure time, mAs, compressed breast thickness, average glandular dose and body mass index that were classified in the examination of both breasts by CC(cranio-caudal) and MLO(medio-lateral oblique) with EMR(electronic medical record) and dose report that were sent to the PACS(picture archiving communication system). As a result, in the site inspection according to the age, Compressed breast thickness in CC and MLO were the thickest of 45.6 mm and 49.6 mm in the 50-59 year old respectively. In the overall average compressed breast thickness, CC were 44.2 mm and MLO were 48.9 mm. MLO has more thick by 4.7 mm. In average glandular dose, CC were 1.05 mGy and MLO were 1.14 mGy. MLO has higher by 0.09 mGy than CC. As the compressed breast thickness increases 10mm, CC and MLO increases 0.15 mGy and 0.17 mGy respectively. When it was compared with the average glandular dose of 1.16 mGy per 1 film presented by KFDA, CC was showed 1.05 mGy. However, the 60 mm or more was found to exceed a 1.30 mGy. Also, As the compressed breast thickness was higher, body mass index showed high score. And in the case of 25 or more in the obese body index according to body mass index, it was showed obesity in case of the compressed breast thickness was more than 50mm.