• Title/Summary/Keyword: Breast, mammography

Search Result 336, Processing Time 0.021 seconds

A Study on Compression Paddle Materials to Reduce Radiation Exposure Dose During Mammography; PC and PMMA and Carbon (유방촬영 시 피폭선량을 줄이기 위한 압박대 재질의 PC, PMMA, Carbon에 대한 연구)

  • Hong, Dong-Hee;Jung, Hong-Ryang
    • Journal of radiological science and technology
    • /
    • v.38 no.2
    • /
    • pp.81-87
    • /
    • 2015
  • This study was designed the band material in order to reduce the exposure pressure of the breast and the material was measured of Radiolucent and radiation properties with a radiation materials of PC, PMMA, Carbon. Also the image quality by image analysis to obtain the following results are below: Unfors Xi dosimetry using radiation transmittance when the results of 8.353mGy is measured after removal of the cuff, the PC 6.308mGy, PMMA 6.223mGy, Carbon 7.218mGy were measured respectively. Semi-layer PC 0.375mmAl, PMMA 0.370mmAl, with Carbon 0.360mmAl Carbon, PC, PMMA was higher radiation properties and transparency in order. InLight / OSL NanoDotTM dosimeter was used in the cuff and then removed by placing the dosimeter measured results center on 1.143mGy, at the edge 12.56mGy, on the central PC 8.990mGy, at the edge 10.291mGy, PMMA center on 8.391mGy, the edge 9.654mGy, on Carbon center 9.581mGy, 11.313 mGy were measured at the edge of Carbon, PC, PMMA showed a high permeability in order. Image Pixel average J is then removed from the cuff 976.655, PC 831.032, PMMA 819.069, Carbon 897.118 Carbon, PC, PMMA was measured by high order.

A Study on the Image Enhancement Method of Digital Mammogram in the Wavelet Domain (웨이블렛 영역에서 디지털 맘모그램의 영상향상 방법에 관한 연구)

  • Jeon, Geum-Sang;Jang, Boo-Hwan;Kim, Sang-Hee
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.13 no.1
    • /
    • pp.6-11
    • /
    • 2012
  • Digital mammogram is effective for detecting the micro-calcification that is early symptom of breast cancer. In the digital mammogram, many image processing techniques have been studied for accurate diagnosis and efficient treatment of micro-calcification lesion. The wavelet based multi-scale method was mainly used to enhance the image contrast. This paper presents an advanced mammography enhancement method which is based both on the brightness and the contrast enhancement in the wavelet domain. The proposed method normalizes a dynamic range using histogram of the image. The brightness is enhanced by modifying coefficients of low frequency components, and the contrast is enhanced by coefficients of high frequency component based on the multi-scale contrast measure. The experiment results show that the proposed method yields better performance of the image enhancement over the existing methods.

A Study on the Sasang Constitutional Characteristics of Obese Middle-Aged Women (중년비만여성의 사상체질별 특성에 관한 연구)

  • Lim, Jinny;Lee, In-Soon;Koh, Byung-Hee;Song, Il-Byung;Lee, Soo-Kyung
    • Journal of Sasang Constitutional Medicine
    • /
    • v.16 no.3
    • /
    • pp.59-69
    • /
    • 2004
  • 1. Objectives This research is to ascertain relations between the Sasang Constitution and characteristics of the eating attitudes, mental state, body composition, various examination results of obese middle-aged women. 2. Methods The subjects were 31 female patients whose BMI(Body Mass Index) was over $25kg/m^2$ and age was 35~55. It was analysed statistically the results of EAT(The Eating Attitudes Test), DEBQ(Dutch Eating Behavior Questionnaire), BDI(Beck Depression Inventory), STAI(State-Trait Anxiety Inventory), body composition analyser, biochemistry, abdominal ultrasonography, mammography which was surveyed from them. 3. Results and Conclusions 1)There was no relation between the Sasang Constitution and the eating attitudes, eating behaviors. But Taeumin got statistically lower score than Non-Taeumin in 23rd question for emotional eating and 33rd question for environmental eating of DEBQ 2)On the mental state, Taeumin got statistically lower score than Non-Taeumin in BDI, STAI-S 3)On the body composition, Taeumin got statistically higher value than Non-Taeumin in BMI. Soyangin got statistically lower value than Non-Soyangin in BMI, left upper limb water, soft lean mass, body water, trunk water. 4)On the various examinations, Taeumin got statistically lower value than Non-Taeumin in serum albumin. Soyangin got statistically lower value in BMI and higher frequency in gallstone, breast nodule than Non-Soyangin. 5)It was thought that Taeumin's obesity is managed by controling physical factor such as excessive 'Gathering Qi(吸聚之氣)' rather than eating attitudes and psychological factor.

  • PDF

Comparison of the Imaging Features of Lobular Carcinoma In Situ and Invasive Lobular Carcinoma of the Breast (유방의 소엽상피내암과 침윤성 소엽암의 영상의학적 소견 비교)

  • Ga Young Yoon;Joo Hee Cha;Hak Hee Kim;Min Seo Bang;Hee Jin Lee;Gyungyub Gong
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.5
    • /
    • pp.1231-1245
    • /
    • 2021
  • Purpose To investigate the usefulness of imaging features for differentiating between small lobular carcinoma in situ (LCIS) and invasive lobular carcinoma (ILC). Materials and Methods It included 52 female with LCISs (median 45 years, range 32-67 years) and 180 female with ILCs (median 49 years, range 36-75 years), with the longest diameter of ≤ 2 cm, who were evaluated between January 2012 and December 2016. All the female underwent mammography and ultrasonography. Twenty female with LCIS and 150 female with ILC underwent MRI. The clinical and imaging features were compared, and multivariate analysis was performed to identify the independent predictors of LCIS. Female with LCIS were also sub-grouped by lesion size and compared with the female with ILC. Results Multivariate analysis showed that younger age (odds ratio [OR] = 1.100), smaller lesion size (OR = 1.103), oval or round shape (OR = 4.098), parallel orientation (OR = 5.464), and isoechotexture (OR = 3.360) were significant independent factors predictive of LCIS. The area under the receiver operating characteristic curve for distinguishing LCIS from ILC was 0.904 (95% confidence interval, 0.857-0.951). Subgroup analysis showed that benign features were more prevalent in female with smaller LCISs (≤ 1 cm) than in those with ILC. Conclusion Small LCISs tend to demonstrate more benign features than small ILCs. Several imaging features are independently predictive of LCIS.

Acquisition of Monochromatic X-ray using Graded Multilayer Mirror (Graded 다층박막거울을 이용한 단색 엑스선 획득)

  • Ryu, Cheolwoo;Choi, Byoungjung;Son, Hyunhwa;Kwon, Youngman;Kim, Byoungwook;Kim, Youngju;Chon, Kwonsu
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.4
    • /
    • pp.205-211
    • /
    • 2015
  • At a recent medical imaging technology, the major issue of X-ray diagnosis in breast cancer is the early detection of breast cancer and low patient's exposure dose. As one of studies to acquire a monochromatic X-ray, Technologies using multilayer mirror had been preceded. However, a uniform multilayer mirror that consists of uniform thin-film thickness can acquire a monochromatic X-ray only in the partial area corresponds to angle of incidence of white X-ray, so there are limits for X-ray imaging technology applications. In this study, we designed laterally graded multilayer mirror(below GML) that reflects same monochromatic X-ray over the entire area of thin-film mirror, which have the the thickness of the linear gradient that correspond to angle of incidence of white X-ray. By using ion-beam sputtering system added the mask control system we fabricated a GML which has size of $100{\times}100mm^2$. The GML is designed to achieve the monochromatic X-ray of 17.5kev energy and has thin-film thickness change from 4.62nm to 6.57nm(3.87nm at center). It reflects the monochromatic X-ray with reflectivity of more than 60 percent, FWHM of below 2.6keV and X-ray beam width of about 3mm. The monochromatic X-ray corresponded to 17.5keV using GML would have wide application in development of mammography system with high contrast and low dose.

Atypical Ductal Hyperplasia: Risk Factors for Predicting Pathologic Upgrade on Excisional Biopsy (침생검 조직검사에서 진단된 비정형 관상피증식증: 수술적 절제 생검에서 악성으로 진단될 가능성을 예측할 수 있는 위험인자들)

  • Ko Woon Park;Boo-Kyung Han;Sun Jung Rhee;Soo Youn Cho;Eun Young Ko;Eun Sook Ko;Ji Soo Choi
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.3
    • /
    • pp.632-644
    • /
    • 2022
  • Purpose To determine the incidence of atypical ductal hyperplasia (ADH) in needle biopsy and the upgrade rate to carcinoma, and to evaluate difference in findings between the upgrade and non-upgrade groups. Materials and Methods Among 9660 needle biopsies performed over 48 months, we reviewed the radiologic and histopathologic findings of ADH and compared the differences in imaging findings (mammography and breast US) and biopsy methods between the upgrade and non-upgrade groups. Results The incidence of ADH was 1.7% (169/9660). Of 112 resected cases and 30 cases followed-up for over 2 years, 35 were upgraded to carcinoma (24.6%, 35/142). The upgrade rates were significantly different according to biopsy methods: US-guided core needle biopsy (USCNB) (40.7%, 22/54) vs. stereotactic-vacuum-assisted biopsy (S-VAB) (16.0%, 12/75) vs. USguided VAB (US-VAB) (7.7%, 1/13) (p = 0.002). Multivariable analysis showed that only US-CNB (odds ratio = 5.19, 95% confidence interval: 2.16-13.95, p < 0.001) was an independent predictor for pathologic upgrade. There was no upgrade when a sonographic mass was biopsied by US-VAB (n = 7) Conclusion The incidence of ADH was relatively low (1.7%) and the upgrade rate was 24.6%. Surgical excision should be considered because of the considerable upgrade rate, except in the case of US-VAB.