• 제목/요약/키워드: Breaking Capacity

검색결과 93건 처리시간 0.036초

수계 장용 정제 코팅에 관한 공정개선 및 효과 (Process Improvement and Effect for Enteric Tablet Coating Using Aqueous System)

  • 정노희;신강현
    • 한국응용과학기술학회지
    • /
    • 제22권3호
    • /
    • pp.234-240
    • /
    • 2005
  • In this study, we have prepared three kinds of enteric tablet coating formulations for prevention the crack incidence and enhanced process improvement of enteric tablet using aqueous system. we determined the mechanical strength of three formulatons on the enteric film-coating process. The compared experiment of one-layer and two-layer (A), (B) coating treated having placebo tablets without breakline and logo. In result, the breaking force time of two-layer (B) film strength was found to increase 0.8min than two-layer (A). We confirmed the half reduction of working hour and the simplification in the one-layer coating process, and the coating troubles was solved as setting up a dehumidifier in inlet of coater. In result, we recovered that optimum running capacity(g/kg) of dehumidifier is 10g/kg and below.

154kV 이상 수전고객 고장전류 차단용량 부족 차단기 교체비용 지원 검토 (Study on supporting replacement cost to the insufficient breaking capacity breaker for 154kV customer)

  • 황종영;박진홍;원영진;안광원;김재훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.153-154
    • /
    • 2008
  • 우리나라 전력수요의 지속적인 증가는 발전설비 및 송전망의 동반 성장으로 전력계통 규모가 꾸준히 확장되어 왔다. 그러나 이로 인해 전력계통 고장전류가 증가하는 문제가 발생하여, 그에 대한 대책으로 차단기 교체 등을 시행하고 있다. 이와 관련하여 고객서비스차원에서 한국전력은 전원 측 계통확장으로 인한 차단용량 부족 154kV 이상 수전고객에 대해서 차단기를 교체하도록 차단기 교체을 지원하기로 하였다. 이에 본 논문에서는 한국전력에서 시행하고자 하는 대용량고객 차단기 교체 지원내용에 대하여 알아보고자 한다.

  • PDF

차단용량 향상을 위한 신소호 구조 (New Arc Chamber to Improve Breaking Capacity)

  • 박진영;조해용
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제36권2호
    • /
    • pp.321-326
    • /
    • 2012
  • 배선용 차단기(MCCB)를 구성하는 개폐기구부, 아크(Arc)소호부, 트립(Trip)부는 차단기의 성능을 결정짓는 중요한 요소들이다. 그 중 아크소호부는 차단시 발생한 아크를 소호실 안쪽으로 유도하여 여러개의 짧은 아크로 분할시키며 아크를 냉각, 소멸시켜 차단을 빠르게 하는 구조이다. 본 연구에서는 새로운 소호구조를 제안하였고, 차단 성능이 우수한 변수에 대한 최적화 실험을 하였으며, 이를 토대로 실제 실험제품에 적용하여 성능 향상에 대한 연구를 수행하였다.

800kV, 50kA 차단기의 전절연 검증을 위한 시험방법 검토 (Review about test method for the full-insulation verification of circuit breaker rated on 800kV, 50kA)

  • 박승재;서윤택;윤학동;김용식;김맹현;고희석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.569-571
    • /
    • 2005
  • In case of dead-tank circuit breaker with the earthed enclosure, the dielectric performance for phase to ground should be verified under the hot-gas condition produced by the current interruption. This test condition is required in breaking test duties with the rated short-circuit current and rated voltage. And, KERI has completed the reinforcement of the synthetic testing facilities and these facilities have the testing capacity which enables the full-pole testing for 800kV circuit breaker by adopting the series voltage injection method. So, this paper introduced the test circuit and procedures about the full-pole and the multi-part testing method which was devised to estimate the full -insulation of phase-to-ground for the multi-pole and dead-tank circuit breaker.

  • PDF

Weil-Dobke 합성단락시험로의 최적화 연구 (A Study on Optimization of the Weil-Dobkes Synthetic Short-Circuit Tests)

  • 김맹현;고희석
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권6호
    • /
    • pp.287-292
    • /
    • 2001
  • This paper deals with the configuration, operating principles, systematic calculation method of parameter and optimization method of test circuit for parallel current injection method, series voltage injection method and hybrid synthetic test method as the method for performance test of circuit breaker with extra high interrupting capacity. The test method depicted above is applied to short-circuit making and breaking test (operating sequence :Os CdOs, Od-CdOs) and out-of-phase tests(operating sequence :Os, CdOs) for performance test of the newly-developed 420kV, 50kA and 800kV 50kV puffer-type gas circuit-breaker according to IEC 60056 and IEC 60427. The testing results, evaluation of equivalence for test and analyzed results are also presented in this paper.

  • PDF

고장계산 및 보호협조 판정 소프트웨어 개발 (A Development of Software about Short-circuit Calculation and Protective-coordination)

  • 박성찬;최장흠;서정민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.159-162
    • /
    • 2002
  • A software, called touch-one, is developed about the determination of short-circuit values and protective co-ordination in power system. The used solution algorithm reviewed intensively, and the protective co-ordination determination technique presented by using the circuit-breaker's current-limitation characteristic. The protective coordination concerns the behaviour of two devices placed in series in an electrical network, with a short-circuit downstream circuit-breaker. It has two basic principles: First, discrimination which is an increasing requirement of low voltage electrical distribution systems. Second, which is less well known: cascading, which consists of installing a device, whose breaking capacity is less than the three-phase short-circuit current at its terminals and helped by main circuit-breaker. With this software, we can construct a electric-power system which is reliable and economic according to user's purpose.

  • PDF

가스절연 개폐장치 투입저항의 동특성 해석 (Dynamic Characteristics Analysis of Closing Resistors of Gas Insulated Switchgear)

  • 조해용;이성호;임성삼;이기정;김민우
    • 한국정밀공학회지
    • /
    • 제22권11호
    • /
    • pp.104-110
    • /
    • 2005
  • GIS(Gas Insulated Switchgear) is used in electric power system, to insure non conductivity, breaking capacity and operating reliability. The commercial dynamic analysis code COSMOS MOTION and 3-D modeling program SOLID WORKS were used to simulate dynamic analysis of the closing resistors of the GIS in this paper. To reduce chatter vibration of closing resistors, the motion of moving and fixed parts of closing resistors were simulated by varying the spring constant, the damping coefficient and the mass of moving and fixed parts. The simulated results were compared with experimental results. As a result, chatter vibration of closing resistors of the GIS could be reduced by using the results. These data can be used to determine the spring constant, the damping coefficient and mass of a moving part to reduce chatter vibration when the next model is developed.

조선시대 복식규제를 통해서 본 사치풍조의 제 요인과 복식변화 - 17.18세기를 중심으로 - (The Factors of Luxury Trend and Fashion Changes as Result of Costume Regulations during Choson Dynasty: 17th and 18th Century)

  • 이민주
    • 복식문화연구
    • /
    • 제11권4호
    • /
    • pp.551-561
    • /
    • 2003
  • The regulations for costume were set to improve people's moral fiber and cultural standards. In the 17th and 18th century, the main aim of this regulation was to prohibit luxury. But being the turning point to a modem state, with breaking social status and development of commerce, industry, and the mind of imitation, regulation for luxury wasn't enforced, but rather it brought many revolutionary changes in costume. Restraining human impulse to express beauty was no longer subject to regulation. Therefore, people started to recognize the human figure with shorter Jegory(저고리) and strengthened ceremonial capacity by broadening po's(포) sleeves. The silk fabrics were the most popular fabric during this era, special patterns were added for decoration and also for blessings. Complementary colors were used for contrast on the collar (깃), cuffs (끝동), Gyotrnagi (곁마기), and sash (고름). This color composition gave a younger and more active look. And with red stripes on the sleeves, it emphasized the beauty of the color arrangements as well as providing protection from the devil.

  • PDF

소호 재료에 따른 기중 아크 차단 현상의 실험적 연구 (Experimental Study on Air Arcs Interruption Phenomena with Arc Quenching Materials)

  • 이상엽;연영명;박홍태;오일성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1751-1753
    • /
    • 2002
  • Arc phenomena occur in the air, must be more diverse than vacuum and SF6. An air arc interruption method has been used in low rated voltage circuit breakers such as ACB, MCCB and MCB. Most of them have the arc chamber composed of arc chutes and lateral walls that made of many kinds of materials. Therefore, the criterion of material selection is necessary for breaking capacity improvement. So, we selected some contact and lateral wall materials, and carried out short circuit tests. Especially, some parameters of arc plasma properties were very different each polymeric wall material.

  • PDF

아크 소호재의 종류 및 입도에 따른 휴즈의 차단 특성에 관한 연구 (Interrupting Characteristics of Fuses Element in Different Fillers)

  • 김인성;한동희;장문순;이세현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.900-902
    • /
    • 1999
  • This paper deals with the interrupting characteristics of fuses element in different media of arc extinguisher. Aluminum hydro-oxide, boron nitride, silica and there size have been investigated here for their prospects as filling media in heavy current, high breaking capacity fuses. The result of these study are compared with those on silica sand at high current. This study demonstrates that silica sand is far superior filler in fuses for heavy current interrupting then the compound tested.