• Title/Summary/Keyword: Breakdown test

Search Result 474, Processing Time 0.036 seconds

A Robust Test for Location Parameters in Multivariate Data (다변량 자료에서 위치모수에 대한 로버스트 검정)

  • So, Sun-Ha;Lee, Dong-Hee;Jung, Byoung-Cheo
    • The Korean Journal of Applied Statistics
    • /
    • v.22 no.6
    • /
    • pp.1355-1364
    • /
    • 2009
  • This work propose a robust test for location parameters in multivariate data based on MVE and MCD with the affine equivariance and the high-breakdown properties. We consider the hypothesis testing satisfying high efficiency and high test power simultaneously to bring in the one-step reweighting procedure upon high-breakdown estimators, which generally suffer from the low efficiency and, as a result, usually used only in the exploratory analysis. Monte Carlo study shows that the suggested method retains nominal significance levels and higher testing power without regard to various population distributions than a Hotelling's $T^2$ test. In an example, a data set containing known outliers does not make an influence toward our proposal, while it renders a Hotelling's $T^2$ useless.

An Experimental Study on the Fire Investigation to the Broken Plane Types of Glass (유리 파단면의 화재감식에 관한 실험적 연구)

  • Mun, Yong-Soo;Kong, Ha-Sung
    • Journal of the Korea Safety Management & Science
    • /
    • v.10 no.4
    • /
    • pp.105-109
    • /
    • 2008
  • The purpose of this study is to distinguish the causes of broken glass on doors or windows when it is originally kept among the remains on the floor in fire site - whether it was broken due to heating or outer power-through test and characteristics of the broken plane including the pattern on the plane. Addition to it, the study tries to find characteristics to judge the point and direction of breakdown through the analysis of glass broken by outer power. With two assumed causes - a) breakdown due to heating and b) breakdown due to outer power-3 pieces of glass plates ($30cm{\times}30cm{\times}5mm$) were tested for each case, getting the results as following: First, for the glass broken due to the change of temperature, the broken plane is of slow and smooth curve without any pattern. Second, for the glass broken due to outer power, with the impact point as the center, the glass shows breakdown of radial type and the side shows breakdown of near-perpendicular type. The far the broken piece is from the impact point, the bigger the size is. The broken piece at the impact point is of long triangle type and the two long planes of the triangle shows semi-arc with the center of breakdown point and the other plane shows opposite pattern. Third, when glass that is damaged by outer power is heated, damaged forms and side patterns of the glass that is damaged by outer power are heated and disappeared.

A Study on the Electrical Breakdown Characteristics of Air according to Electrode Gap (전극 간격에 따른 공기의 절연파괴 특성에 관한 연구)

  • Kang, Jong O;Lee, Onyou;Kim, Junil;Bang, Seungmin;Lee, Hongseok;Lee, Jong Doug;Kang, Hyoungku
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.4
    • /
    • pp.301-306
    • /
    • 2014
  • Recently in accordance with the rapid development of the industrial society, the accidents caused by dielectric breakdown have been increasing in power grid. It is important to prevent the dielectric breakdown of a high voltage apparatus to reduce the damage from electrical hazards. To establish an electrically reliable database of insulation design criteria for high voltage apparatus, a study on dielectric characteristics test is indispensable. In this study, dielectric characteristics according to field utilization factors (${\xi}$) which are represented as the ratio of mean electric field to maximum electric field are investigated. the dielectric breakdown experiments by using several kinds of electrode systems made with stainless steel are performed by AC breakdown voltage under air-insulation. Also, the experimental results are analyzed by the Weibull distribution. As a result, it is found that the dielectric characteristics of air-insulation are determined by ${\xi}$ as well as arrangement of electrode systems. It is considered that the results of this study would be applicable to designing the air-insulated high voltage apparatuses.

Electrical Properties of the Epoxy Nano-composites according to Additive

  • Shin, Jong-Yeol;Park, Hee-Doo;Choi, Kwang-Jin;Lee, Kang-Won;Lee, Jong-Yong;Hong, Jin-Woong
    • Transactions on Electrical and Electronic Materials
    • /
    • v.10 no.3
    • /
    • pp.97-101
    • /
    • 2009
  • The use of a filler material in epoxy composite materials is an essential condition for reducing the unit cost of production and reinforcing mechanical strength. However, the dielectric strength of insulators decreases rapidly due to interactions between the epoxy resin and filler particles. In contrast to existing composite materials, nano-composite materials have superior dielectric strength, mechanical strength, and enduring chemical properties due to an increase in the bond strength of the polymer and nano material, It is reported that nano-fillers provide new characteristics different from the properties of the polymer material. This study is to improve the insulation capability of epoxy resins used in the insulation of a power transformer apparatus and many electronic devices mold. To accomplish this, the additional amount of nano-$SiO_2$ to epoxy resin was changed and the epoxy/$SiO_2$ nano composite materials were made, and the fundamental electrical properties were investigated using a physical properties and an analysis breakdown test. Using allowable breakdown probability, the optimum breakdown strength for designing an electrical apparatus was determined. The results found that the electrical characteristics of the nano-$SiO_2$ content specimens were superior to the virgin specimens. The 0.4 wt% specimens showed the highest electrical properties among the specimens examined with an allowable breakdown probability of 20 %, which indicates stable breakdown strength in insulating machinery design.

A study on the identification of the causes according to the broken plane types of glass (유리 파단면의 형태 식별에 따른 파손원인 감정에 대한 연구)

  • Mun, Yong-Su;Sa, Sang-Yeol;Choe, Min-Seok;Choe, Jae-Ho;Kim, Yong-Su
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.3 no.1
    • /
    • pp.12-15
    • /
    • 2003
  • The purpose of this study is to distinguish the causes of broken glass from doors or windows when it is found being originally kept among the remains on the floor in fire site - whether it was broken due to heating or by outer power through test and the properties of the broken plane including the pattern on the plane. Addition to it, the study tries to find characteristics for judging the point and direction of breakdown through the analysis of glass broken by outer power. With two causes assumed - a. breakdown due to heating and b. breakdown due to outer power - 3 pieces of glass plates $(30cm{\times}30cm{\times}5mm)$ for each case were tested, getting the results as following: 1. For the glass broken due to the change of temperature The broken plane is of slow curve and smooth without any pattern. 2. For the broken due to outer power With the impact point as the center, the shows breakdown of radial type and the side shows breakdown of near-perpendicular type. The far the broken piece is from the impact point, the bigger the size is. The broken piece at the impact point is of long triangle type and the two long planes of the triangle shows semi-arc with the center of breakdown point and the other plane shows opposite pattern 3. Change of the pattern and type of the glass due to outer power The pattern and type of the glass due to outer power shows change due to heatihg.

  • PDF

Judgement Criterion of Insulation Deterioration in 4.16kV and 6.6kV Motor Stator Windings (4.16kV 및 6.6kV 전동기 고정자 권선의 절연열화 판정기준)

  • Kim, Hee-Dong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.4
    • /
    • pp.788-794
    • /
    • 2009
  • To assess the condition of stator insulation, nondestructive tests were performed on twenty five coil groups and twenty six motors. The stator windings has nominal ratings of 6.6kV and are classified into five coil groups ;one group with healthy insulation and four groups with four different types of artificial defects. After completing nondestructive tests, the AC voltage applied to the stator windings was gradually increasing until insulation failure in order to obtain the breakdown voltage. No.1, No.2 and No.6 of 6.6kV motors failed near rated voltage of 14kV, 8.7kV and 14kV, respectively. The breakdown voltage of three motors was lower that expected for good quality coils(14.2kV) in 6.6kV motors. No.3 and No.6 of 4.16kV motors failed near rated voltage of 5.6kV and 4.2kV, respectively. Almost all of failures were located in a line-end coil at the exit from the core slot. The breakdown voltages and the types of defects showed strong relation to the stator insulation tests such as in the case of AC current, dissipation factor(tan${\delta}$) and partial discharge magnitude.

Time-Dependent Dielectric Breakdown Characteristics of Thin $SiO_2$ Films and Their Correlation to Defects in the Oxide (얇은 산화막의 TDDB 특성과 막내의 결함과의 상관성)

  • Sung, Yung-Kwon;Choi, Jong-Ill;Kim, Sang-Yung;Han, Sung-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1988.11a
    • /
    • pp.147-150
    • /
    • 1988
  • Since the integration level of VLSI circuits progresses very quickly, a highly reliable thin $SiO_2$ film is required to fabricate a small-geometry MOS device. In the present study we have attempted to eliminate the failure-causing defects that develop in thin oxide films during the oxidation step by performing a long-time preoxidation and postoxidation annealing. The TDDB test and the copper decoration method were used to calculate the oxide defects density of MOS device. The dielectric reliability of high-quality thin oxides have been studied by using the time-zero-dielectric-breakdown (ramp-voltage-stressed I-V) and time-dependent-dielectric -breakdown (Constant-stressed I-V) tests. Failure times against temperature and electric field are examined and acceleration factors are abtained for each parameter. Based on the data obtained, breakdown wearout limitation for thin oxide films is estimated.

  • PDF

Properties of Electrical Breakdown in the Interface between XLPE / EPDM (XLPE/EPDM 계면에서의 절연파괴 특성)

  • Jo, J.H.;Han, S.K.;Lee, C.J.;Kim, S.K.;Choi, Y.S.;Park, K.S.;Suh, K.S.;Park, D.H.;Han, S.O.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1469-1471
    • /
    • 1996
  • In this paper, We intended to evaluate the characteristics of XLPE/EPDM interface which exists in the cable joint. The fault of practical cable was mainly occurred in this interface. Thus we looked into the electrical characteristics through the conduction current and the breakdown test. Through the experiment, we obtained the result that the conduction current in this interface flowed less than other dielectric materials, that the breakdown strength was higher and that the pressure dependance of the breakdown strength was higher.

  • PDF

Breakdown Characteristics and Survival Probability of Turn-to- Turn Models for a HTS Transformer

  • Cheon H.G.;Baek S.M.;Seong K.C.;Kim H.J.;Kim S.H.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.7 no.2
    • /
    • pp.21-26
    • /
    • 2005
  • Breakdown characteristics and survival probability of turn-to-turn models were investigated under ac and impulse voltage at 77K. For experiments, two test electrode models were fabricated: One is point contact model and the other is surface contact model. Both are made of copper wrapped by O.025mm thick polyimide film(Kapton). The experimental results were analyzed statistically using Weibull distribution in order to examine the wrapping number effects on voltage-time characteristics under ac voltage as well as under impulse voltage in LN$_{2}$. Also survival analysis were performed according to the Kaplan-Meier method. The breakdown voltages of surface contact model are lower than that of point contact model, because the contact area of surface contact model is wider than that of point contact model. Besides, the shape parameter of point contact model is a little bit larger than that of surface contact model. The time to breakdown t$_{50}$ is decreased as the applied voltage is increased, and the lifetime indices slightly are increased as the number of layers is increased. According to the increasing applied voltage and decreasing wrapping number, the survival probability is increased.

Dielectric Strength of $SF_6/CF_4$ Mixture Under Standard Lightning Impulse Voltages in Non-Uniform Field (불평등 전계에서 표준 뇌 임펄스 전압의 $SF_6/CF_4$ 혼합 가스의 절연 내력)

  • Huh, Chang-Su;Sung, Heo-Gyung;Park, Shin-Woo;Hwang, Cheong-Ho;Kim, Nam-Ryul
    • Proceedings of the KIEE Conference
    • /
    • 2007.11a
    • /
    • pp.165-166
    • /
    • 2007
  • In these days $SF_6$ mixtures and alternative gas have been studied because of global warming and liquefying at low temperature and high pressure. At present work the breakdown characteristics of $SF_6/CF_4$ mixture in non-uniform field was performed. The experiments were carried out under positive and negative standard lightning impulse (SLT) voltages. The point-plane electrode was used with 3 mm gap distance in the test chamber. The $SF_6/CF_4$ mixture which contain 20% of $SF_6$ was compared with pure $SF_6$ and $CF_4$ gas. Experimental gas pressure ranged from 0.1 to 0.4 MPa. The breakdown voltage under negative SLI is higher than the breakdown voltage under positive voltage. And the breakdown voltage of $SF_6$ 20%, $CF_4$ 80% mixture is similar to that of pure $SF_6$.

  • PDF