• Title/Summary/Keyword: Branch loop

Search Result 62, Processing Time 0.028 seconds

Branch Loop Antenna for the Mobile Handset (휴대 단말기용 브랜치 루프안테나)

  • Son, Taeho
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.12 no.1
    • /
    • pp.58-65
    • /
    • 2013
  • It's introduced a BLA(Branch Loop Antenna) that is modified from conventional loop, and verified antenna performances for applying to mobile handset. Branch elements are added to a rectangular loop, and low resonance is obtained by the length of the branch line. When resonance frequency of a single loop is 2.5GHz, BLA had near 900 MHz under the same antenna size. Multiple resonances are established by the locations of branch connection and their lengths. By the implementation and measurement for the dual band BLA, it's showed 75MHz -10dB bandwidth and -3.03~-1.46dBi average gains with 49.73~71.39% efficiencies at GSM900 band, and 90MHz -6dB bandwidth and -8.14~-2.17dBi average gains with 15.34~60.62% efficiencies at DCS1900 band. And H-plane radiation patterns were omni-directional. These performances are good for the mobile handset antenna.

Thermal Cycling Screening Criteria to RCS Branch Lines in Domestic Nuclear Power Plant (국내 원전 RCS 분기배관에 대한 열피로 선정기준)

  • Park, Jeong Soon;Choi, Young Hwan;Lim, Kuk Hee;Kim, Sun Hye
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.6 no.2
    • /
    • pp.54-60
    • /
    • 2010
  • Piping failures due to thermal fatigue have been widely reported in normally stagnant non-isolable reactor coolant branch lines. Since the thermal fatigue due to thermal stratification was not considered in the piping fatigue design in old NPPs, it is important to evaluate the effect of thermal stratification on the integrity of branch lines. In this study, geometrical screening criteria for Up-horizontal branch lines in MRP-132 were applied to SI(Safety Injection) lines of KSNP 2-loop and WH 3-loop. Some computational fluid dynamic(CFD) analyses on the Reactor Coolant System(RCS) branch lines were also performed to develop the regulatory guidelines for screening criteria. As a result of applying MRP-132 screening criteria, KSNP 2-loop and WH 3-loop SI lines are determined to need further detailed evaluation. Results of CFD analyses show that both valve isolation and amount of leakage through valve can be used as technical bases for the screening criteria on the thermal fatigue analysis.

  • PDF

Complementary Analysis in Reduced Dimension (of Mutual Inductance Imbedded Network)

  • 이태원;안수길
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.10 no.5
    • /
    • pp.39-44
    • /
    • 1973
  • In general, solution of electric networks requires both node and loop analysis, in which node pair voltages and loop currents are treated as network variables, but the conjugate quantities of these variables (the branch currents and node pair voltages respectively) are to be obtained through additional solving operation. In case of networks with magnetic coupling, however, the coupling keeps the conjugate variables mutually dependent and its final solution requires further calculation. In this paper is analyzed the method of obtaining the conjugate quantities through treatment of the problrm in a subspace with dimensions of number of magnetically coupled branches.

  • PDF

Extended Loop Antenna for the Mobile Handset (휴대 단말기용 연장 루프안테나)

  • Son, Taeho;Ryu, Hwang
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.12 no.2
    • /
    • pp.30-37
    • /
    • 2013
  • An extended loop antenna, to be continued BLA(Branch Loop Antenna) in the previous volume, for the mobile handset is designed in this paper. It's introduced an ELA(Extended Loop Antenna) that is added extended loops to rectangular loop, and verified antenna performances for applying to mobile handset. Extended loops are located upside, left and right side of rectangular loop, and low resonance is obtained by the length of line. Multiple resonances are established by the extended loops, and obtained the desired service bands by the connection points and lengths. By the implementation and measurement for the multiband ELA, it's showed -3.0~-1.46dBi average gains with 50.15~71.41% efficiencies at CDMA/GSM frequency band, and -8.28~-1.7dBi average gains with 14.87~67.68% efficiencies at DCS/USPCS/WCDMA frequency band.

Current Source Disposition of Large-scale Network with Loop-reduction Drawing Technique (망축소작도법에 의한 대형회로망 전류원 처리)

  • Hwang, Jae-Ho
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.49 no.5
    • /
    • pp.278-286
    • /
    • 2000
  • A new large-scale network geometric analysis is introduced. For a large-scale circuit, it must be analyzed with a geometric diagram and figure. So many equations are induced from a geometric loop-node diagram. The results are arranged into a simple matrix, of course. In case of constructing a network diagram, it is not easy to handle voltage and current sources together. Geometric loop analysis is related to voltage sources, and node analysis is to current sources. The reciprocal transfer is possible only to have series or parallel impedance. If not having this impedance, in order to obtain equivalent circuit, many equations must be derived. In this paper a loop-reduction method is proposed. With this method current source branch is included into the other branch, and disappears in circuit diagram. So the number of independent circuit equations are reduced as much as that of current sources. The number is not (b-n+1), but (b-n+1-p). Where p is the number of current sources. The reduction procedure is verified with a geometric principle and circuit theory. A resultant matrix can be constructed directly from this diagram structure, not deriving circuit equations. We will obtain the last results with the help of a computer.

  • PDF

Effect of Spray System on Fission Product Distribution in Containment During a Severe Accident in a Two-Loop Pressurized Water Reactor

  • Dehjourian, Mehdi;Rahgoshay, Mohammad;Sayareh, Reza;Jahanfarnia, Gholamreza;Shirani, Amir Saied
    • Nuclear Engineering and Technology
    • /
    • v.48 no.4
    • /
    • pp.975-981
    • /
    • 2016
  • The containment response during the first 24 hours of a low-pressure severe accident scenario in a nuclear power plant with a two-loop Westinghouse-type pressurized water reactor was simulated with the CONTAIN 2.0 computer code. The accident considered in this study is a large-break loss-of-coolant accident, which is not successfully mitigated by the action of safety systems. The analysis includes pressure and temperature responses, as well as investigation into the influence of spray on the retention of fission products and the prevention of hydrogen combustion in the containment.

Reliability analysis of the switch installation in the main feeder and in the radial/loop lateral feeders in distribution system (간선 및 분기선의 개폐기 설치 효과 분석(II))

  • Cho, Nam-Hun;O, Jae-Hyeong;Lee, Heung-Ho;Ha, Bok-Nam
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.83-86
    • /
    • 2002
  • In this study, we evaluate the effectiveness of a switch installation between on the radial and loop lateral feeders to increase reliability by decreasing the duration of the outage. These results can help power utility to design the switch layouts on the radial and loop lateral feeder system.

  • PDF

Improved Delay-Locked Loop in a UWB Impulse Radio Time-Hopping Spread-Spectrum System

  • Zhang, Weihua;Shen, Hanbing;Kwak, Kyung-Sup
    • ETRI Journal
    • /
    • v.29 no.6
    • /
    • pp.716-724
    • /
    • 2007
  • As ultra-wideband impulse radio (UWB-IR) uses short-duration impulse signals of nanoseconds, even a small number of timing errors can cause a detrimental effect on system performance. A delay-locked loop (DLL) is proposed to synchronize and reduce timing errors. The design of the DLL is vital for UWB systems. In this paper, an improved DLL is introduced to a UWB-IR time-hopping spread-spectrum system. Instead of using only two central correlator branches as in a conventional DLL, the proposed system uses two additional correlator branches with different delay parameters and different weight parameters. The performance of the proposed schemes with the optimal parameters is compared with that of traditional schemes through simulation: the proposed four-branch DLLs achieves less tracking jitter or a longer mean time to lose lock (MTLL) than the conventional two-branch DLLs if proper parameters are chosen.

  • PDF

Optimal Scheduling of SAD Algorithm on VLIW-Based High Performance DSP (VLIW 기반 고성능 DSP에서의 SAD 알고리즘 최적화 스케줄링)

  • Yu, Hui-Jae;Jung, Sou-Hwan;Chung, Sun-Tae
    • The Journal of the Korea Contents Association
    • /
    • v.7 no.12
    • /
    • pp.262-272
    • /
    • 2007
  • SAD (Sum of Absolute Difference) algorithm is the most frequently executing routine in motion estimation, which is the most demanding process in motion picture encoding. To enhance the performance of motion picture encoding on a VLIW processor, an optimal implementation of SAD algorithm on VLIW processor should be accomplished. In this paper, we propose an implementation of optimal scheduling of SAD algorithm with conditional branch on a VLIW-based high performance DSP. We first transform the nested loop with conditional branch of SAD algorithm into a single loop with conditional branch which has a large enough loop body to utilize fully the ILP capability of VLIW DSP and has a conditional branch to make the escape from loop to be achieved as soon as possible. And then we apply a modulo scheduling technique to the transformed single loop. We test the proposed implementation on TMS320C6713, and analyze the code size and performance with respect to processing time. Through experiments, it is shown that the SAD implementation proposed in this paper has small code size appropriate for embedded applications, and the H.263 encoder with the proposed SAD implementation performs better than other H.263 encoder with other SAD implementations.

An Application of the Optimal Routing Algorithm for Radial Power System using Improved Branch Exchange Technique (개선된 선로교환 기법을 이용한 방사상 전력계통의 최적 라우팅 알고리즘의 적용)

  • Kim, Byeong-Seop;Sin, Jung-Rin;Park, Jong-Bae
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.6
    • /
    • pp.302-310
    • /
    • 2002
  • This paper presents an application of a improved branch exchange (IBE) algorithm with a tie branch power (TBP) flow equation to solve the Optimal Routing problem for operation of a radial Power system including power distribution system. The main objective of the Optimal Routing problem usually is to minimize the network real power loss and to improve the voltage profile in the network. The new BE algorithm adopts newly designed methods which are composed by decision method of maximum loss reduction and new index of loss exchange in loop network Thus, the proposed algorithm in this paper can search the optimal topological structures of distribution feeders by changing the open/closed states of the sectionalizing and tie switches. The proposed algorithm has been evaluated with the practical IEEE 32, 69 bus test systems and KEPCO 148 bus test system to show favorable performance gained.