• 제목/요약/키워드: Bracket bonding

검색결과 99건 처리시간 0.026초

도재브라켓 접착면의 처리방식이 전단결합강도에 미치는 영향 (EFFECTS OF THE DIFFERENT CERAMIC BRACKET BASES ON SHEAR BOND STRENGTH)

  • 김진오;이기수
    • 대한치과교정학회지
    • /
    • 제24권4호
    • /
    • pp.957-967
    • /
    • 1994
  • The purpose of this study was to evaluate the effects of different bases of ceramic brackets on shear bond strength and to observe failure patterns of bracket bondings. Lower bicuspid brackets whose bases designed for the macromechanical and silane treated chemical bonding those for silane treated chemical bonding, those for micromechanical bonding, and those for macromechanical bonding were tested as experimental groups, and foil mesh-backed metal brackets as a control group. All the brackets were bonded with $Mono-Lok\;2^{(TM)}$ on the labial surface of extracted human lower bicuspids after etching the enamel with $38\%$ phosphoric acid solution for 60 seconds. The shear bond strengths were measured on the universal test machine after 24 hours passed in the $37^{\circ}C$ water bath. The gathered data were evaluated and tested by ANOVA and Duncan's multiple range test, and those results were as follows. The shear bond strengths of brackets for macromechanical and chemical bonding, those for chemical bonding, and those for micromechanical bonding were not different (p>0.05), but showed statistically higher than those of metal bracket and those of ceramic bracket for micromechanical bonding(p<0.05). The shear bond strengths of ceramic bracket for micromechanical bonding showed statistically lower than those of metal bracket(p<0.05). The enamel fractures and/or ceramic bracket fractures were observed in the cases of higher bond strength than that of metal bracket. These results supported that silane treated base of ceramic bracket show higher shear bond strength than that of metal bracket, and suggested that micromechanical form of ceramic bracket bases show higher shear bond strength than that of macromechanical form.

  • PDF

접착술식에 따른 전단강도 및 Bracket위치의 비교 (THE COMPARISON OF SHEAR STRENGTH AND BRACKET PLACEMENT BETWEEN BONDING TECHNIQUES)

  • 박윤경;국윤아;김상철
    • 대한치과교정학회지
    • /
    • 제21권3호
    • /
    • pp.513-520
    • /
    • 1991
  • The purpose of this study was to compare the bracket placement and the shear bond strength of indirect-bonded brackets with those of direct-bonded ones. Forty eight extracted human teeth were collected and attached with brackets and tested on shear bond strength, using Instron. Fourteen patients from Wonkwang University Dental Hospital were selected for direct bonding of brackets and their teeth were measured on bracket angulation and bracket height. The obtained results were as follows: 1. The shear bond strengths of incisors were higher in direct-bonding,group, rather than in-direct-bonding group. But, the shear bond strength of premolars showed no significant differences between groups. 2. The bracket angulations of indirect-bonding group were preciser than those of direct-bonding group, especially in upper first premolars, lower lateral incisors, canines, premolars. 3. In bracket height, there were no significant differences between groups.

  • PDF

도재 브라켓의 전단접착강도에 관한 실험적 연구 (IN VITRO SHEAR BOND STRENGTH OF CERAMIC BRACKETS)

  • 이승진;장영일
    • 대한치과교정학회지
    • /
    • 제22권2호
    • /
    • pp.449-474
    • /
    • 1992
  • The purpose of this study was to evaluate the in vitro shear bond strengths to enamel and the failure sites of three ceramic brackets and one metal bracket in combination with light cured orthodontic adhesive. The brackets were divided into four groups. Each ceramic bracket group had different bonding mechanisms with adhesive. Group A; metal bracket with foil-mesh base (control group) Group B; ceramic bracket with micromechanical retention Group C; ceramic bracket with chemical bonding Group D; ceramic bracket with mechanical retention and chemical bonding. Forty extracted human lower first premolars were prepared for bonding and 10 brackets for each group were bonded to prepared enamel surfaces with $Transbond^{\circledR}$ light cured ortho dontic adhesive. Twenty four hours after bonding, the Instron universal testing machine was used to test the shear bond strength of brackets to enamel. After debonding, brackets and enamel surfaces were examined under stereoscopic microscope to determine the failure sites, Statistical analysis of the data was carried out with ANOVA test and $Scheff\acute{e}$ test using SPSS PC+. The results were as follows. 1 . There were statistically significant differences in mean shear bond strengths of three ceramic bracket groups (p < 0.05). Shear bond strengths of group C and D were significantly higher than that of group B and shear bond strength of group C was significantly higher than that of group D. 2. Group C and D both had significantly higher shear bond strengths than metal bracket (group A), but there were no significant differences in shear bond strengths between group A and B (p < 0.05). 3. The failure sites of four bracket groups were also different. Group C and D failed primarily at enamel-adhesive interface, but group A and B failed primarily at bracket base-adhesive interface. 4. Among all ceramic bracket groups, group B was very similar to metal bracket in the aspect of shear bond strength and failure site.

  • PDF

Direct-bonding bracket 의 인장강도(引張?度) (TENSILE STRENGTH OF DIRECT-BONDING BRACKETS)

  • 권오원
    • 대한치과교정학회지
    • /
    • 제12권2호
    • /
    • pp.139-144
    • /
    • 1982
  • 저자(著者)는 3가지 종류(種類)의 bracket을 교정(矯正)을 위(爲)해서 발치(拔齒)한 20개(個)씩의 소구치(小臼齒)에 접착(接着)하여 24시간(時問) 후(後)에 인장강도(引張?度)를 측정(測定)한 결과(結果) 다음과 같은 결론(結論)을 얻었다. foil-mesh base bracket과 photo-etched base bracket의 평균인장강도(平均引張强度)는 통계학적(統計學的)으로 유의(有意)한 차(差)가 없으며, plastic bracket은 인장강도(引張强度) 측정(測定) 시(時) wing의 변형(變形)에 의(依)해서 정확(正確)한 측정(測定) 결과(結果)를 얻을 수 없 었다. 접착제(接着劑)가 떨어진 양상(樣相)은 foil-mesh base bracket과 photo-etched base bracket에서 접착제(接着劑)가 치아(齒牙)와 bracket 에 부분적(部分的)으로 붙어서 떨어진 것이 각기(各其) 50%로 가장 많았고, 접착제(接着劑)가 치아(齒牙)에만 붙어서 떨어진 것 (30%, 35%), 접착제(接着劑)가 bracket에만 붙어서 떨어진 것 (20%, 15%) 순(順)으로 나타났다.

  • PDF

3Y-$ZrO_2$ 세라믹과 교정용 브라켓계에서 세라믹의 표면 조건에 따른 접착 거동의 변화 (Effect of Surface Condition on the Bonding Characteristics of 3Y-$ZrO_2$-Metal Bracket System)

  • 오선미;김진성;이채현
    • 대한치과기공학회지
    • /
    • 제33권1호
    • /
    • pp.47-54
    • /
    • 2011
  • Purpose: To investigate shear bonding strength between dental zirconia ceramics with different surface treatment and metal bracket. Methods: Zirconia ceramics(LAVA, 3M ESPE, USA) were divided to 4 groups according to their surface treatment; no surface treatment(G1), sand blasting(G2), silane coating(G3), and sand blasting+silane coating(G4). Specimens were bonded to metal bracket using resin bond($Transbond^{TM}XT$, 3M Unitek, USA). Shear bond strength was measured using universal test machine(3366 INSTRON. U.S.A) with cross head speed of 1 mm/min. Microstructural investigation for fracture surface was performed after shear test. Results: Shear bonding strengths of single surface treatment groups (G2 and G3) were higher than no treatment group(G1). Combined Treatment Group (G4) showed the highest shear bond strength of 9.15MPa. Microstructural observation shows that higher shear bonding strength was obtained when debonding was occurred at metal bracket/resin interface rather than zirconia ceramic/resin interface. Conclusion: Surface treatment of zirconia is necessary to obtain higher bonding strength. Combined treatment can be more effective when surface the surfaces are kept clean and homogeneous.

화학적(化學的)으로 재생(再生)된 금속(金屬) bracket의 접착(接着) 강도(强度)와 slot폭경(幅徑) 변화(變化)에 관(關)한 연구(硏究) (A STUDY OF BONDING STRENGTH AND CHANGE OF BRACKET SLOT WIDTH OF CHEMICALLY RECYCLED METAL BRACKETS)

  • 고영삼;이동주
    • 대한치과교정학회지
    • /
    • 제20권2호
    • /
    • pp.283-291
    • /
    • 1990
  • The purpose of this study was to measure and compare tensile and shear strength for 4 types of new direct-bonding brackets and same brackets after recycling and to evaluate the change of bracket slot width after recycling. Four types of new direct-bond brackets were bonded to recently extracted human premolar teeth and the tensile and shear strength was measured by Universal Testing Machine. The brackets were recycled by chemical process and the tensile and shear test was repeated. To evaluate the change of the bracket slot width, slot width was measured by the Topcon Universal Measuring Microscope before and after recycling. Following results were obtained: 1. There was no satistically significant difference between the tensile and shear strength of recycled brackets and those of new brackets. 2. In both new and recycled brackets, the tensile and shear strength of perforated base bracket was lower than those of photoetched, foilmesh and contou-lok mesh base brackets. (P<0.01) 3. There was no statistically significant difference in bonding strengths of control group bonded only once and two times. 4. There was no statistically significant difference in the change of the bracket slow width after recycling process. 5. Of the failure, the combination type (58%) in the tensile strength and the tooth adhesive interface (65%) in the shear strength was the most common type.

  • PDF

Plasma arc light를 이용한 bracket 부착시의 전단결합강도와 파절양상의 유형 (Shear bond strength and adhesive failure pattern in bracket bonding with plasma arc light)

  • 유형석;오영근;이승연;박영철
    • 대한치과교정학회지
    • /
    • 제31권2호통권85호
    • /
    • pp.261-270
    • /
    • 2001
  • 본 연구의 목적은 bracket 부착시 광조사시간을 획기적으로 감소시킬 수 있는 plasma arc light의 임상적 유용성을 visible light 중합시의 전단결합강도와 접착파절양상과 비교해 봄으로써 평가해 보는데 있다. 사람의 상하악 소구치를 포매하여 만든 레진블럭시편에 광중합 접착제인 Transbond$^{\circledR}$를 사용하여 수종의 bracket을 각각의 조건에 따라 부착한 후 만능 물성시험기를 이용하여 전단결합강도를 측정하고, 접착파절양상을 stereoscope을 이용하여 관찰하여 다음과 같은 결과를 얻었다. 1. Plasma arc light를 이용한 수종의 bracket 접착시 metal bracket과 ceramic bracket의 전단결합강도는 임상적으로 사용하기에 충분한 값을 나타내었으며, resin bracket 경우 다른 bracket 비해 전단결합강도가 현저히 작은 값을 나타내었지만 임상적으로 사용이 가능한 값을 나타내었다. 2. Visible light를 이용한 metal bracket의 광중합시 광조사시간에 따른 전단결합강도는 광조사 시간에 따른 유의한 차이를 보이지 않았으며, 임상적으로 사용하기에 충분한 강도를 나타내었다. 3. Plasma arc light를 이용한 수종의 bracket 접착시 접착제 잔류지수를 통해 접착파절양상을 관찰한 결과, metal bracket과 resin bracket 경우 bracket기저면에 접착제가 반 이상 남아 있지 않은 경우가 많았으며, ceramic bracket의 경우 bracket기저면에 접착제가 반 이상 남아 있는 경우가 많았다. 4. Metal bracket의 부착시 plasma arc light를 2초간 광조사한 군과 visible light를 10초간 광조사한 군의 전단결합강도와 접착파절양상을 비교시 유의한 차이를 보이지 않았다. 6. Plasma arc light를 이용한 광중합시 광조사 거리에 따른 전단결합강도는 거리가 증가할수록 감소하였다. 이상의 실험 결과는 plasma arc light를 이용한 bracket의 접착시 전단결합강도 저하의 우려 없이 임상적으로 사용 가능함을 시사한다.

  • PDF

Debonding forces of three different customized bases of a lingual bracket system

  • Sung, Jang-Won;Kwon, Tae-Yub;Kyung, Hee-Moon
    • 대한치과교정학회지
    • /
    • 제43권5호
    • /
    • pp.235-241
    • /
    • 2013
  • Objective: The purpose of this study was to investigate whether extension of the custom base is necessary for enhancement of bond strength, by comparing the debonding forces and residual adhesives of 3 different lingual bracket systems. Methods: A total of 42 extracted upper premolars were randomly divided into 3 groups of 14 each for bonding with brackets having (1) a conventional limited resin custom base; (2) an extended gold alloy custom base: Incognito${TM}$; and (3) an extended resin custom base: KommonBase${TM}$. The bonding area was measured by scanning the bracket bases with a 3-dimensional digital scanner. The debonding force was measured with an Instron universal testing machine, which applied an occlusogingival shear force. Results: The mean debonding forces were 60.83 N (standard deviation [SD] 10.12), 69.29 N (SD 9.59), and 104.35 N (SD17.84) for the limited resin custom base, extended gold alloy custom base, and extended resin custom base, respectively. The debonding force observed with the extended resin custom base was significantly different from that observed with the other bases. In addition, the adhesive remnant index was significantly higher with the extended gold alloy custom base. Conclusions: All 3 custom-base lingual brackets can withstand occlusal and orthodontic forces. We conclude that effective bonding of lingual brackets can be obtained without extension of the custom base.

Three-dimensional evaluation of the transfer accuracy of a bracket jig fabricated using computer-aided design and manufacturing to the anterior dentition: An in vitro study

  • Park, Jae-Hyun;Choi, Jin-Young;Kim, Seong-Hun;Kim, Su-Jung;Lee, Kee-Joon;Nelson, Gerald
    • 대한치과교정학회지
    • /
    • 제51권6호
    • /
    • pp.375-386
    • /
    • 2021
  • Objective: To evaluate the accuracy of a one-piece bracket jig system fabricated using computer-aided design and manufacturing (CAD/CAM) by employing three-dimensional (3D) digital superimposition. Methods: This in vitro study included 226 anterior teeth selected from 20 patients undergoing orthodontic treatment. Bracket position errors from each of the 40 arches were analyzed quantitatively via 3D digital superimposition (best-fit algorithm) of the virtual bracket and actual bracket after indirect bonding, after accounting for possible variables that may affect accuracy, such as crowding and presence of the resin base. Results: The device could transfer the bracket accurately to the desired position of the patient's dentition within a clinically acceptable range of ± 0.05 mm and 2.0° for linear and angular measurements, respectively. The average linear measurements ranged from 0.029 to 0.101 mm. Among the angular measurements, rotation values showed the least deviation and ranged from 0.396° to 0.623°. Directional bias was pronounced in the vertical direction, and many brackets were bonded toward the occlusal surface. However, no statistical difference was found for the three angular measurement values (torque, angulation, and rotation) in any of the groups classified according to crowding. When the teeth were moderately crowded, the mesio-distal, bucco-lingual, and rotation measurement values were affected by the presence of the resin base. Conclusions: The characteristics of the CAD/CAM one-piece jig system were demonstrated according to the influencing factors, and the transfer accuracy was verified to be within a clinically acceptable level for the indirect bracket bonding of anterior teeth.