• Title/Summary/Keyword: Box-type passing

Search Result 15, Processing Time 0.028 seconds

Flowability of High Flowable Concrete with Fly Ash and Lime Powder (플라이 애시와 석회석 미분말을 혼용한 고유동 콘크리트의 유동 특성)

  • Cho Il-Ho;Sung Chan-Yong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.48 no.4
    • /
    • pp.23-30
    • /
    • 2006
  • This study is performed to evaluate flowability of high flowable concrete using ordinary portland cement, crushed coarse aggregate, crushed sand, sea sand, fly ash, lime powder and superplasticizer. The slump flow and air content are increased with increasing the content of lime powder. But, the O-type funneling time and Box-type passing are decreased with increasing the content of lime powder. The slump flow, air content, O-type funneling time, Box-type passing and L-type filling of target compressive strength 21-27 MPa and 35-42 MPa at curing age 28 days are 47-50 cm and 56-60 cm, 4.2-5.5% and 4.0-5.7%, 8-12s and 5-10s, 4.3-5.0 cm and 3.4-5.0 cm, and excellent, respectively. These concrete can be used for high flowable concrete.

Flow Properties of Polypropylene Fiber Reinforced High flow Concrete (폴리프로필렌 섬유보강 고유동 콘크리트의 유동 특성)

  • Noh, Kyung-Hee;Sung, Chan-Yong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.46 no.4
    • /
    • pp.57-63
    • /
    • 2004
  • This study was performed to evaluate flow properties of polypropylene fiber reinforced high flow concrete. Test results were showed that the slump, slump flow and L-type compacting were decreased with increasing the content of polypropylene fiber. But, the Box-type passing and air content were increased with increasing the content of polypropylene fiber. The slump was $25.5{\sim}27.5cm$, the slump flow was $60{\sim}65cm$, the Box-type passing was $2{\sim}6cm$, the L-type compacting was excellent and air content was $2.7{\sim}3.2cm%$ by the polypropylene fiber content 0.2%, respectively. This concrete can be used for high flow concrete.

Engineering Properties of Steel Fiber Reinforced High Performance Concrete

  • Kim Young Ik;Sung Chan Yong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.46 no.7
    • /
    • pp.55-67
    • /
    • 2004
  • In this paper, the flowability, strengths, impact resistance and sulfuric acid resistance of steel fiber reinforced high performance concrete (SFHPC) for the steel fiber content and fly ash and blast furnace slag as admixtures were presented. For evaluating flowability particularly, tests of slump flow, box-type passing ability and L-type filling ability were performed. The slump flow of SFHPC was some decreased with increase of the steel fiber content. At the box-type passing ability, the difference of box height of SFHPC is greatly increased with increasing the fiber content. The L-type filling ability of SFHPC was not excellent above $0.75\% of the steel fiber content. Also, the compressive strength of SFHPC was decreased with increase of the steel fiber content, but the flexural strength of SFHPC was much higher than that of the concrete without the steel fiber. At the impact resistance, drop number of SFHPC for reaching final fracture was increased with increase of the fiber content. Also, the drop number for reaching initial fracture of lmm was increased with increase of the fiber content. At the sulfuric acid resistance, 4-week weight change of SFHPC with the steel fiber was almost similarity that of HPC without the steel fiber and was in the range of 73.6 to 81.5.

Piping Analysis of Reservoir Embankment due to Leakage of Buried Box Culvert (저수지 제체 내 배수통관의 누수로 인한 파이핑 분석)

  • Kim, Han il;Yang, Hak Young;Kim, Young Muk
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.5
    • /
    • pp.787-799
    • /
    • 2017
  • Although the long-term leakage between the box culvert and the soil contact surface is one of the main causes of the failure in the embankment of the reservoir, there is a little studies on this matter. If a leakage occurs by the structure such as the buried box culvert of reservoir embankment is partially damaged, it is difficult to observe and there is a possibility of damage caused by piping. For these reasons, more research is necessary. In this study, the embankment type of the reservoir is divided into the core type and the homogeneous type when the damaged box culvert passing through the embankment of the reservoir is leaked due to the differential behavior of materials like differential settlement. In view of the condition, the seepage analysis of 2D was performed according to the water level change. The result of the study shows that the possibility of piping increases at the upper part rather than the bottom part of the box culvert when the leakage occurs to the box culvert passing through the embankment of the reservoir. Particularly, it is considered that the presence of the core helps to maintain the seepage stability of the embankment in case where the leakage occurs at the downstream side of the embankment. Also, if there is a drastic decrease on the internal pore water pressure in the embankment of reservoir, it is necessary to consider the possibility of piping.

Flowing Ability and Mechanical Properties of Polypropylene Fiber Reinforced High Performance Concrete

  • Kim, Young-Ik;Sung, Chan-Yong
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.7
    • /
    • pp.27-37
    • /
    • 2003
  • This study was performed to examine the flowing ability and filling ability of polypropylene fiber reinforced high performance concrete. The slump flow was decreased with increasing the polypropylene fiber content, rapidly. At the box-type filling ability, the difference of box height was increased with increasing the fiber content and the box-type passing ability was closed in fiber content 1 %. The final flowing distance of L-type was decreased with increasing the fiber content. Also, it was decreased above 0.75% of polypropylene fiber content, rapidly. The filling ability of L-type was badly showed above polypropylene fiber content 0.75%. Also, the compressive strength was decreased with increasing the fiber content, but the flexural strength was shown higher than that of the concrete without fiber. At the impact resistance, drop numbers for reaching in final fracture were increased with increasing the fiber content. Also, the drop numbers for reaching initial fracture of 1mm were increased with increasing the fiber content. At the acid resistance, the percent of original mass was decreased with increasing the fiber content.

Large-Scale Vortical Structure of Turbulent Separation Bubble Affected by Unsteady Wake (비정상 후류가 난류박리기포의 응집구조에 미치는 영향)

  • Jeon, Se-Jong;Seong, Hyeong-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.9
    • /
    • pp.1218-1225
    • /
    • 2002
  • Large-scale vortical structure of a turbulent separation bubble affected by unsteady wake is essential to understand flow mechanisms in various fluid devices. A spoked-wheel type of wake generator provides unsteady wake, which modifies the turbulent separation bubble significantly by changing rotation directions and passing frequencies. A detailed mechanism of vortex shedding from the separation bubble with unsteady wake is analyzed by taking a conditional average with spatial box filtering, which spatially integrates measured signals at pre-determined wavelength. A convecting nature of the large-scale vortical structure is analyzed carefully. Spatial evolution of the large-scale vortical structure with frequency variance is also exemplified.

Fluidity of Super Flow Concrete Using Recycled Coarse Aggregate (재생굵은골재를 사용한 초유동 콘크리트의 유동성)

  • Sung, Chan-Yong;Park, Il-Soon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.47 no.2
    • /
    • pp.55-61
    • /
    • 2005
  • This study was performed to evaluate fluidity of super flow concrete using recycled coarse aggregate. The unit weight was $2,246{\sim}2,344\;kg/m^3$, the unit weights of these concrete were decreased with increasing the content of fly ash and recycled coarse aggregate. The slump flow was $58{\sim}63\;cm$, the Box type passing was $3.4{\sim}6.8\;cm$, respectively. The L type compacting was excellent in the fly ash content $10\%\;and\;20\%$, but, it was showed in good in the fly ash content $30\%$. The super flow concretes using recycled coarse aggregate were improved by substitution in the range of less than the fly ash content $20\%$ and recycled coarse aggregate content $75\%$. This recycled coarse aggregate can be used for super flow concrete.

Experimental Study on the Effect of the Amount of Cellulose type Viscosity Agent on the Physical Properties of High-Fluidity Concrete Using Low-Binder (셀룰로스계 증점제의 첨가량이 고유동 저분체 콘크리트의 물리적 특성에 미치는 영향에 관한 실험적 연구)

  • Ko, Hye-Bin;Cho, In-Sung;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.129-130
    • /
    • 2021
  • For the development of high-fluidity concrete using low-binder, The effect of the use of the developed acrylic viscosity agent on the physical properties of concrete evaluated. The amount acrylic viscosity agent used was 0.28%, 0.29% and 0.30% based on the binder amount of 350kg/m3, and slump flow test, air volume measurement, U-Box passing test and strength compressive were conducted to determine the effect of the physical properties of concrete. it was judged that 0.29% of the cellulose type viscosity agent used in high-fluidity concrete using low-binder was most suitable.

  • PDF

Dynamic Characteristics of High-speed Railway Steel Bridges (고속철도 강교량의 진동특성 분석)

  • Lee, Jung-Whee;Kim, Sung-Il;Kwark, Jong-Won;Lee, Pil-Goo;Yoon, Tae-Yang
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.7 s.124
    • /
    • pp.632-637
    • /
    • 2007
  • The dynamic behavior of two steel bridges crossed by the Korean High Speed Train(KHST) has been investigated experimentally and the results are compared with the specification requirement of BRDM and other typical PSC Box bridge's responses. The investigated bridges are a 2-girder steel bridge of 1@40m span length(E-Won Bridge), 2@50m span length (Ji-Tan Bridge), and a PSC Box girder bridge of 2@40m span length (Yeon-Jae Bridge). A set of experimental tests were performed during operation of KHST, and a number of accelerometers, LVDTs and ring-type displacement transducers were utilized for measurement of three kinds of dynamic responses (acceleration, deflection, and end-rotation angle). Measured responses show that the vertical deflections and end-rotation angles of the three bridges are all satisfying the spec. requirement with large margin, but it was also found acceleration responses which are very close or exceed the limit value. Most of the excessive acceleration responses were found when the passing velocity of the KHST is close to the critical velocity ($V_{cr}$) which causes resonance. No noticeable differences of dynamic responses due to the different materials(steel or concrete) could be found within these experimental results.

Reduction of train-induced vibrations on adjacent buildings

  • Hung, Hsiao-Hui;Kuo, Jenny;Yang, Yeong-Bin
    • Structural Engineering and Mechanics
    • /
    • v.11 no.5
    • /
    • pp.503-518
    • /
    • 2001
  • In this paper, the procedure for deriving an infinite element that is compatible with the quadrilateral Q8 element is first summarized. Enhanced by a self mesh-expansion procedure for generating the impedance matrices of different frequencies for the region extending to infinity, the infinite element is used to simulate the far field of the soil-structure system. The structure considered here is of the box type and the soils are either homogeneous or resting on a bedrock. Using the finite/infinite element approach, a parametric study is conducted to investigate the effect of open and in-filled trenches in reducing the structural vibration caused by a train passing nearby, which is simulated as a harmonic line load. The key parameters that dominate the performance of wave barriers in reducing the structural vibrations are identified. The results presented herein serve as a useful guideline for the design of open and in-filled trenches concerning wave reduction.