• 제목/요약/키워드: Bottom Floor

Search Result 179, Processing Time 0.023 seconds

A Study on Thickness Optimization of Bottom Floor for Container Ship (컨테이너선 Bottom Floor 두께 최적화에 대한 연구)

  • Lee, A-Mi;Ryu, Yeong-Ung;Lee, Joon-Hyuk;You, Yeong-Gyu
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2011.09a
    • /
    • pp.95-100
    • /
    • 2011
  • In general, thickness of bottom floor in fore/aft cargo hold region for container ship has been determined based on FEM analysis result of mid cargo hold region. But this approach has room for improvement because section shape and frame spacing in fore/aft cargo hold of container ship are quietly different from those of mid cargo hold. From this study, correlation between FEM result and grillage analysis result has been investigated and simple method for thickness determination of bottom floor in fore/aft cargo hold using newly improved grillage analysis is proposed.

  • PDF

Vibration Transmission of Railway Floor Structure due to Connecting Materials (연결재료에 따른 철도차량 바닥구조의 진동전달)

  • Shin, Bum-Sik;Chun, Kwang-Wook;Choi, Yeon-Sun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.11
    • /
    • pp.1320-1325
    • /
    • 2009
  • The sources of the vibration of railway vehicles in the cabin are usually bogie, axle, and wheel. The vibrations are transmitted through the floor structures of railway vehicle. The floor structure is the combination of bottom plate, plywood, and rubber. In this research the vibration transmission is measured experimentally and analyzed numerically to find the transmission characteristics of the vehicle floor structures. The result shows that the vibration characteristic of soft rubber is better than hard rubber or wood as the connecting material between the bottom plate and the plywood.

A Study of Application Characteristic Evaluation Research of Flexible FRP Resin on the Roof and Floor of Parking Area (연질 FRP수지의 옥상주차장바닥 적용성 평가 연구)

  • Lee, Hyung-Jun;Kim, Sung-Sik;Ahn, Sang-Ku;Cho, Ah-Hyung;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2007.11a
    • /
    • pp.129-132
    • /
    • 2007
  • From this research the construction civil official is simple with the parking floor finishing material, it improves the durability of the parking floor it uses the flexible FRP it will be able to secure the drainage quality it is excellent and it presents the efficient application plan from the construction site. The performance appraisal only efficiency with of result floor of parking area material bay it knows, the result where also the performance appraisal portion re-with roof bottom finishing is satisfied it showed. The flexible FRP it applies the material to the building as to diminish the damage of the bottom finishing material due to the deterioration and the conduct and the external force of the building it is exposed to the external environment, secures the quality of the material from the construction site and will contribute to the stability against the bottom finishing material.

  • PDF

Thermal performance prediction of amorphous steel fibers mixed into the floor heating system (비정질 강섬유 혼입 바닥난방시스템의 열성능 평가)

  • Cho, Hyun;Pang, Seung-Ki
    • Journal of Energy Engineering
    • /
    • v.25 no.3
    • /
    • pp.130-135
    • /
    • 2016
  • The thermal performance of amorphous steel fibers mixed floor heating system was evaluated. Analysis of results, depending on the hot water supply temperature changes, the average temperature of the bottom of the hot water supply temperature is an amorphous steel fiber floor heating system is about 2~4% higher. The average temperature of the floor surface to 1.5m air amorphous steel fiber system is 1~2% higher. The amount of heat supplied to indoor air (1.5m) from the bottom surface of amorphous steel fiber floor heating system is about 7~8% higher

Evaluation of Natural Ventilation Performance using the Multi-Functional Floor Heating System (다기능온돌시스템을 이용한 자연환기성능 평가)

  • Cho, Dong-Woo;Yu, Ki-Hyung;Yu, Jung-Yeon;Jung, Hae-Kwon
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.105-112
    • /
    • 2007
  • Recently developed raised floor heating system is not only capable of basic function to reduce noise between floors, but also is a multi-functional floor heating system enabling natural ventilation. The procedure of this system for natural ventilation is to import outdoor air through bottom space of the floor heating system, circulate indoor space and discharge it out of ceiling. In winter, powerless natural ventilation is possible with buoyancy effect caused by temperature difference between outdoor and indoor. And it also allows saving of energy by importing pre-heated air in bottom space of the floor heating system. To evaluate ventilation performance of this system, on-site measurement was conducted in 2 test laboratories, and the nominal air change rate was satisfied as 0.4$\sim$0.8 h-1 under the condition of outdoor temperature $5^{\circ}C{\sim}-5^{\circ}C$, which was evaluated as highly possible to be applied as a natural ventilation system in multi-family houses.

  • PDF

Comparative Evaluation of Electric Power and LNG Load according to Floor level of Tower-Type Apartments (탑상형 아파트의 층별 전기와 가스 부하량 비교평가)

  • Kim, Jun Hyun;Choi, Jin Ho;Um, Jung-Sup
    • Journal of Environmental Impact Assessment
    • /
    • v.20 no.4
    • /
    • pp.465-475
    • /
    • 2011
  • It is known that energy consumption in bottom floor of typical Korean-style apartment is the highest. Previous studies for energy consumption in accordance with floor level appear to be very limited due to the dependence on single energy variable such as electric power or LNG separately, based on past flat type of apartment. Acknowledging these constraints, an empirical study for a tower type emerged recently as new style of apartment in South Korea was conducted to demonstrate how a comprehensive evaluation for both electric power and LNG consumption can be used to assist in monitoring the total energy consumption in terms of floor specific settings. It was possible to identify that energy consumption in bottom floor is lesser than that of top floor, to the contrary, fact known from previous study. Also electric power consumption in top floor was identified as 15% higher than that of floor in the least. It is anticipated that this integrated utilization of electric power and LNG data would present more scientific and objective evidence for the energy load among floor level of tower type apartment by overcoming serious constraints suffered from the past single variable investigation. Ultimately, the result in this paper could be used as a valuable reference to providing priority for energy saving activities in top floor such as cool roof or green roof.

Parameter analysis for gas hydrate data of East sea using Geobit (지오빗을 이용한 동해 가스하이드레이트 탄성파 자료처리 매개변수 분석)

  • Kim, Young-Wan;Jang, Seong-Hyung;Kim, Hyun-Tae;Yoon, Wang-Joong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.377-381
    • /
    • 2006
  • A seismic survey for gas hydrate have performed over the East sea by the KIGAM since 1997. General indicator of gas hydrate in seismic data is commonly inferred from the BSR(Bottom Simulating Reflector) that occurred parallel to the sea floor, amplitude decrease at the top of the BSR, amplitude blanking at the bottom of the BSR, decrease of the interval velocity and the reflection phase reversal at the BSR. In this paper we had analyzed optimum parameters of the field data to detect the 9as hydrate. Shot delay correction is applied 95ms, spherical divergence correction is applied velocity library 3, bandpass filter is applied 25-30-115-120Hz deconvolution operator length is applied 60ms, lag is 6ms and accurate velocity analysis NMO correction, stack is performed. Geobit 2.11.0 developed by the KIGAM was used for all data processing. Processing results say that the BSR occurred parallel to the sea floor were shown at 3,150m/s of two way travel time from the sea floor through shot point 5,000-5,610, and identified the interval velocity decrease around BSR and the reflection phase reversal corresponding to the reflection at the sea floor.

  • PDF

Comparative Evaluation of Condensation by Type and Layer Around Built-in Furniture of Apartment Buildings (WUFI를 이용한 공동주택 붙박이가구의 층별·형태별 결로 생성 비교 평가)

  • Yoo, Jiwon;Chang, Seong Jin;Lee, Jongki;Wi, Seunghwan;Kim, Sumin
    • Journal of the Korea Furniture Society
    • /
    • v.29 no.1
    • /
    • pp.31-39
    • /
    • 2018
  • Recently, as the continuously increasing of the one-person households, builders were focusing on a built-in furniture development for efficiency. Through the dead space of the space can be reduced. Also, Condensation that occurs in a built-in furnitures installation space may result in different results depending on the room's direction, floor, finish, adjacent room effect, occupant's lifestyle. In this background, it can be considered in terms of functional aspect and morphological aspect by using WUFI2D simulation system. As a result, the tendency of occurrence of condensation was examined by comparing the water content and the growth potential of fungus graph which came from WUFI2D. Results of this study are as followings: Built-in furniture, both top & bottom open, is more stable to condensation than the built-in furniture with the top or bottom open. Also, Among from the top floor built-in furniture to the bottom of it, the bottom one is more stable to condensation.

  • PDF

Study on Corrosion Law of Large Crude Oil Storage Tank Floor and Risk-Based Inspection and Maintenance Technology

  • Luo, Fang-Wei;Ran, Ran;Wang, Lei
    • Corrosion Science and Technology
    • /
    • v.19 no.2
    • /
    • pp.66-74
    • /
    • 2020
  • In this paper, the author's team has carried out a comparative experimental study on the corrosion characteristics of Q235 steel commonly used in large-scale storage tanks under the specific bottom water environment found with Russian and Daqing crude oil. It was found that there is a certain degree of uniform or local corrosion on the tank floor depending on the kind of bottom water. The bottom water corrosion of Daqing crude oil is a uniform corrosion caused by carbon dioxide. While the Russian crude oil bottom water corrosion is clearly local corrosion caused by co-corrosion of carbon dioxide and hydrogen sulfide, here the corrosion rate is obviously higher than that caused by Daqing crude oil. There are two modes of storage tank inspection and maintenance that have been currently adopted by Chinese refining and chemical enterprises: a regular inspection mode and a API581-2016 risk-based detection mode. These modes have been effectively combined to form an intelligent tank inspection and maintenance mode, software tools to support this intelligent inspection and maintenance management have been developed.

The Characteristics of Waves on the Steep Sloping Sea Bottom (급경사 해저면에 대한 파랑의 반응특성)

  • Yeom, W.G.;Lee, J.W.
    • Journal of Korean Port Research
    • /
    • v.6 no.2
    • /
    • pp.43-64
    • /
    • 1992
  • This study discusses the interacting with deep water waves approaching from deep water based on the linear wave theory and steep sloping sea bottom floor by the numerical procedure. The results of particular interest are particle velocity and acceleration in x, y, z direction wave height amplification factor reflection coefficient and dimensionless pressure distribution on the steep sloping bottom with respect to the various incident wave angle. The wave loads relative to various bottom slopes, incident wave angles and wave periods on submerged breakwater and pipe are represented in comparison with mild sloping bottom the wave load parameters on the steep sloping bottom seemed to be influenced by variation of incident wave angle. In general the particle velocities and accelerations in x, y, z directions on the steep sloping bottom represented larger value or about two than those on the mild sloping bottom according to incident wave angle. However, the wave height amplification factors did not show distinct difference, but the slight variation with respect to the various incident angle showed on mild sloping bottom. The reflection coefficient increased with respect to increase of the incident angle on the steep sloping bottom the results also indicate that the very steep sloping beach produces a rather substantial amount of reflection as we expected. No significant variation of wave pressure was shown on the steep sloping bottom but it represented a certain amount of variation on the mild sloping bottom according to the various incident wave angle. The analysis at the OTEC site also showed similar results.

  • PDF