• Title/Summary/Keyword: Bone support

Search Result 299, Processing Time 0.026 seconds

Evaluation of accuracies of genomic predictions for body conformation traits in Korean Holstein

  • Md Azizul Haque;Mohammad Zahangir Alam;Asif Iqbal;Yun Mi Lee;Chang Gwon Dang;Jong Joo Kim
    • Animal Bioscience
    • /
    • v.37 no.4
    • /
    • pp.555-566
    • /
    • 2024
  • Objective: This study aimed to assess the genetic parameters and accuracy of genomic predictions for twenty-four linear body conformation traits and overall conformation scores in Korean Holstein dairy cows. Methods: A dataset of 2,206 Korean Holsteins was collected, and genotyping was performed using the Illumina Bovine 50K single nucleotide polymorphism (SNP) chip. The traits investigated included body traits (stature, height at front end, chest width, body depth, angularity, body condition score, and locomotion), rump traits (rump angle, rump width, and loin strength), feet and leg traits (rear leg set, rear leg rear view, foot angle, heel depth, and bone quality), udder traits (udder depth, udder texture, udder support, fore udder attachment, front teat placement, front teat length, rear udder height, rear udder width, and rear teat placement), and overall conformation score. Accuracy of genomic predictions was assessed using the single-trait animal model genomic best linear unbiased prediction method implemented in the ASReml-SA v4.2 software. Results: Heritability estimates ranged from 0.10 to 0.50 for body traits, 0.21 to 0.35 for rump traits, 0.13 to 0.29 for feet and leg traits, and 0.05 to 0.46 for udder traits. Rump traits exhibited the highest average heritability (0.29), while feet and leg traits had the lowest estimates (0.21). Accuracy of genomic predictions varied among the twenty-four linear body conformation traits, ranging from 0.26 to 0.49. The heritability and prediction accuracy of genomic estimated breeding value (GEBV) for the overall conformation score were 0.45 and 0.46, respectively. The GEBVs for body conformation traits in Korean Holstein cows had low accuracy, falling below the 50% threshold. Conclusion: The limited response to selection for body conformation traits in Korean Holsteins may be attributed to both the low heritability of these traits and the lower accuracy estimates for GEBVs. Further research is needed to enhance the accuracy of GEBVs and improve the selection response for these traits.

Hip Resurfacing Arthroplasty after Failure of Tantalum Rod Insertion in Patients with Osteonecrosis of the Femoral Head

  • Yoon Je Cho;Kee Hyung Rhyu;Young Soo Chun;Hyun Gon Gwak
    • Hip & pelvis
    • /
    • v.34 no.4
    • /
    • pp.219-226
    • /
    • 2022
  • Purpose: The purpose of this study was to examine the clinical outcomes and efficacy of hip resurfacing arthroplasty (HRA) in patients with osteonecrosis of the femoral head after the failure of porous tantalum rod insertion without rod removal. Materials and Methods: Conversion to hip resurfacing arthroplasty was performed in 10 patients (11 hips) with a mean period of 14.9 months after the primary surgery. The mean follow-up period was 73.7 months. Analysis of pre and postoperative range of motion (ROM), University of California at Los Angeles (UCLA) activity score, modified Harris hip score, and visual analog scale (VAS) pain score was performed. Radiographic analysis of component loosening and osteolysis was performed. Results: The postoperative ROM showed significant improvement (P<0.05), excluding flexion contracture. The modified Harris hip score showed improvement from 65.82 to 96.18, the UCLA score showed improvement from 4.18 to 8.00, and the VAS pain score was reduced from 6.09 to 1.80. All scores showed statistically significant improvement (P<0.05). No component loosening or osteolysis was detected by radiographic analysis. Conclusion: Satisfactory results were obtained from conversion hip resurfacing arthroplasty after failure of porous tantalum rod insertion without rod removal. The findings of this study demonstrate the advantages of HRA, including no risk of trochanteric fracture and no bone loss around the tantalum rod. In addition, the remaining porous tantalum rod provided mechanical support, which reduced the potential risk of femoral neck fracture or loosening. This technique can be regarded as a favorable treatment option.

Antioxidation Effect of Leg Bone Extracts and Enzyme Hydrolysates from Jeju Crossbred Horses (Jeju Native Horse×Thoroughbred) (제주 재래마와 더러브렛종과의 교잡종인 한라마 사골추출물과 효소분해물의 항산화 효과)

  • Kim, Dongwook;Pak, Jae-In;Chae, Hyun-Seok;Kim, Young-Boong;Jang, Aera
    • Journal of Life Science
    • /
    • v.23 no.9
    • /
    • pp.1147-1154
    • /
    • 2013
  • This study was conducted to evaluate the antioxidation activity of Jeju crossbred horse (Jeju native horse ${\times}$ thoroughbred) leg bone extracts (HLBE) and its enzyme hydrolysates by determination of 1,1-diphenyl-2picryl-hydrazyl (DPPH), 2,2-azino-bis(3-ethylbenzo thiazoline-6-sulfonic acid) diammonium salt (ABTS) radical scavenging activity, ferric reducing/antioxidant power (FRAP), and oxygen radical absorbance capacity (ORAC). HLBE was extracted with hot water for 24 hr and lyophilized. The lyophilized HLBE was hydrolyzed using multifect PR6L (MP), pepsin (PS), and a pepsin and pancreatin mixture (PSPC) for 4 hr at 60, 50, and $50^{\circ}C$, respectively. The hydrolysates were separated by a molecular weight of 3 kDa more or less. When the yield of HLBE was 100%, the yield of hydrolysates less than 3 kDa of MP, PS, and PSPC was 10.86, 3.26, and 8.00%, respectively. Enzyme hydrolysates with low molecular weight less than 3 kDa in MP and PSPC showed significantly higher DPPH, ABTS radical scavenging activity, and ORAC compared to HLBE and its hydrolysates with more than 3 kDa. However, the FRAP of the hydrolysates less than 3 kDa in PS was significantly higher than in MP. These results suggest that low molecular weight enzyme hydrolysates less than 3 kDa have more powerful antioxidation activity, especially when they are hydrolyzed by MP and PSPC rather than PS. Therefore, low molecular weight enzyme hydrolysates of HLBE hydrolyzed with MP and PSPC have significant potential as antioxidants in the food industry. Further in vivo studies are required to support the antioxidation activities of the hydrolysates in vitro.

Study of heat transfer to the implant-bone interface induced by grinding of occlusal surface of implant gold prosthesis (금 합금 보철물의 교합면 삭제로 인한 임플란트-골 계면으로의 열전달에 관한 연구)

  • Jo, Jae-Young;Kang, Sun-Nyo;Jeong, Chang-Mo;Yun, Mi-Jung;Huh, Jung-Bo;Jeon, Young-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.1
    • /
    • pp.29-35
    • /
    • 2012
  • Purpose: The purpose of this study was to analyze temperature change along the implant-bone interface induced by grinding the occlusal surface of implant gold prosthesis and to compare the temperature generated by grinding of prosthesis with different cooling methods. Materials and methods: The experimental gold prostheses were fabricated with dental gold alloy and castable abutment. The prostheses had 3 cylindrical protrusions on the occlusal surface with 1mm in height. Temperature was measured using 16 thermocouple wires attached to the implant fixture surface and the fixture was embedded in an acrylic resin block inside the $37^{\circ}C$ water bath. Cylinders were grinded for a period of 30 second with a low-speed handpiece with green stone point. One cylindrical protrusion was grinded without cooling, the second one was grinded with air blow, and the third one was grinded with water-spray. Results: The mean maximum temperature was measured more than $47^{\circ}C$ of the implant and the maximum temperature was measured at the cervical portion of the implant in the group without cooling. There was statistically significant difference between the group without cooling and the groups with cooling (P<.05). However, there was no significant difference at all portion of implant in the groups with cooling (P>.05). Conclusion: The results of this study support that the grinding of implant gold prosthesis without cooling may damage the peri-implant tissue. The continuous use of air blow and water-spray adjacent to prosthesis during the grinding of implant gold prosthesis may prove to be beneficial for cooling of the implant.

Effect of the Number and Location of Implants on the Stress Distribution in Three-unit Fixed Partial Denture: A Three-Dimensional Finite Element Analysis (임플란트 고정성 보철물에서 수와 식립위치 변화에 따른 골과 임플란트에서의 응력분포에 관한 3차원 유한요소법적 연구)

  • Lee, Woo-Hyun;Lim, Jong-Hwa;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.3
    • /
    • pp.221-239
    • /
    • 2010
  • Bone loss may occur depending on the loading conditions. careful treatment planning and prosthetic procedures are very important factors for the proper distribution of stress. Evaluate the stress distributions according to numbers and location of implants in three-unit fixed partial dentures. A mandible missing the right second premolar, first molar and second molar was modeled. Using the CT data. we modeled a mandible with a width of 15mm, a height of 20mm and a length of 30mm, 2mm-thickness cortical bone covering cancellous bone mallow. An internal type implant and A solid type abutment was used. A model with 3 implants placed in a straight line, offset 1.5 mm buccally, offset 1.5 mm lingually and another model with 3 implants offset in the opposite way were prepared. And models with 2 implants were both end support models, a mesial cantilever model and a distal cantilever model. Three types of loading was applied; a case where 155 N was applied solely on the second premolar, a case where 206 N was applied solely on the second molar and a case where 155 N was applied on the first premolar and 206 N was applied on the first and second molar. For all the cases, inclined loads of 30 degrees were applied on the buccal cusps and vertical loads were applied on the central fossas of the teeth. Finite element analysis was carried out for each case to find out the stress distribution on bones and implants. This study has shown that prostheses with more implants caused lower stress on bones and implants, no matter what kind of load was applied. Furthermore, it was found out that inclined loads applied on implants had worse effects than vertical loads. Therefore, it is believed that these results should be considered when placing implants in the future.

The effects of tissue punch diameter on healing around implants in flapless implant surgery (무피판 임플란트 수술에서 연조직 펀치의 크기가 임플란트 주위 조직의 치유에 미치는 영향)

  • Lee, Du-Hyeong;Jeong, Seung-Mi;Choi, Byung-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.3
    • /
    • pp.301-311
    • /
    • 2009
  • Statement of problem: Flapless implant surgery using a soft tissue punch device requires a circumferential excision of the mucosa at the implant site. To date, Although there have been several reports on clinical outcomes of flapless implant surgeries, there are no published reports that address the appropriate size of the soft tissue punch for peri-implant tissue healing. Purpose: In an attempt to help produce guidelines for the use of soft tissue punches, this animal study was undertaken to examine the effect of soft tissue punch size on the healing of peri-implant tissue in a canine mandible model. Material and methods: Bilateral, edentulated, flat alveolar ridges were created in the mandibles of six mongrel dogs. After a three month healing period, three fixtures (diameter, 4.0 mm) were placed on each side of the mandible using 3 mm, 4 mm, or 5 mm soft tissue punches. During subsequent healing periods, the peri-implant mucosa was evaluated using clinical, radiological, and histometric parameters, which included Gingival Index, bleeding on probing, probing pocket depth, marginal bone loss, and vertical dimension measurements of the peri-implant tissues. Results: The results showed significant differences (P <0.05) between the 3 mm, 4 mm and 5 mm tissue punch groups for the length of the junctional epithelium, probing depth, and marginal bone loss during healing periods after implant placement. When the mucosa was punched with a 3 mm tissue punch, the length of the junctional epithelium was shorter, the probing depth was shallower, and less crestal bone loss occurred than when using a tissue punch with a diameter $\geq$ 4 mm. Conclusion: Within the limit of this study, the size of the soft tissue punch plays an important role in achieving optimal healing. Our findings support the use of tissue punch that 1 mm smaller than implant itself to obtain better peri-implant tissue healing around flapless implants.

Association of osteoarthritis and bone mineral density in women -The health and nutritional examination survey in Kuri- (여성의 골관절염과 골밀도간의 관련성 분석 -구리시민 건강.영양진단 조사결과를 바탕으로-)

  • Sheen, Seung-Soo;Lee, Soon-Young;Min, Byung-Hyun;Suh, Il
    • Journal of Preventive Medicine and Public Health
    • /
    • v.30 no.4 s.59
    • /
    • pp.669-685
    • /
    • 1997
  • Previous studies, reporting the inverse relationship between osteoarthritis and osteoporosis suggest the existence of possible pathophysiologic mechanisms between them. To examinine the hypothesis that 'bone mineral densities of women with osteoarthritis are significantly higher than that of women without osteoarthritis in Korea', subjects from the health and nutritional examination survey in Kuri city were sampled. Samples were selected through multi-stage sampling frame using established clusters in Kuri city. From August 18 to September 10,1997, the survey was conducted. Among the. total number of selected sample population (1,656 people), response .ate was 52.4 percent (348 men and 519 women). 420 women who took BMD measurement, radiologic exam, and anthropometric exam were selected for the analysis. The analytic results are as follows. 1. General characteristics: Mean BMD was $0.493g/cm^2$, mean age was 43.0, mean BMI was $23.9kg/m^2$. The number of women who experienced menopause was 106, hysterectomy was 19. There were 0 case of osteoarthritis of hip, 64 cases of osteoarthritis of knee, and 2 cases of osteoarthritis of hand. 2. Univariate analysis results: Mean BMD of women with the osteoarthritis of knee was significantly lower than that of women without the osteoarthritis of knee(0.4269 vs. $0.5057g/cm^2$). But, there were too few cases of osteoarthritis of hip and hand, so comparative studies of BMD in osteoarthritis of hip and hand could not be conducted. There were significant differences of BMD among pre-menopause group(0.5204), post-menopause group(0.4206), and hysterectomy group(0.4881). Additionally, there were significant differences of BMD among diabetes group(0.4297), impaired glucose tolerance group(0.4874), and normal group(0.5057). Furthermore, age, parity, BMI, bioimpedance were significantly related with BMD. 3. Multivariate analysis results: To examinine the relationship between osteoarthritis and BMD while controlling the other variables' effects which were significant in the univariate analyses, multiple linear regression analysis was done. But, it was found that osteoarthritis of knee was not a significant variable to BMD anymore. While age and menopause had significant negative relationship with BMD. Diabetes, parity, BMI, and bioimpedance did not have significant relationships with BMD. After stratification of subjects according to menopause, multiple linear regression analyses were done to each strata. Consequently, age in post-menopause group, age and osteoarthritis of knee in hysterectomy group showed significant negative relationship with BMD. The results did not support the many results of other previous studies done with white men and women. further studies of biological plausibility to Korean women are recommended. Also it is suggested that longitudinal study to verify the relationship between osteoarthritis and BMD will be valuable.

  • PDF

A Study of Guide System for Cerebrovascular Intervention (뇌혈관 중재시술 지원 가이드 시스템에 관한 연구)

  • Lee, Sung-Gwon;Jeong, Chang-Won;Yoon, Kwon-Ha;Joo, Su-Chong
    • Journal of Internet Computing and Services
    • /
    • v.17 no.1
    • /
    • pp.101-107
    • /
    • 2016
  • Due to the recent advancement in digital imaging technology, development of intervention equipment has become generalize. Video arbitration procedure is a process to insert a tiny catheter and a guide wire in the body, so in order to enhance the effectiveness and safety of this treatment, the high-quality of x-ray of image should be used. However, the increasing of radiation has become the problem. Therefore, the studies to improve the performance of x-ray detectors are being actively processed. Moreover, this intervention is based on the reference of the angiographic imaging and 3D medical image processing. In this paper, we propose a guidance system to support this intervention. Through this intervention, it can solve the problem of the existing 2D medical images based vessel that has a formation of cerebrovascular disease, and guide the real-time tracking and optimal route to the target lesion by intervention catheter and guide wire tool. As a result, the system was completely composed for medical image acquisition unit and image processing unit as well as a display device. The experimental environment, guide services which are provided by the proposed system Brain Phantom (complete intracranial model with aneurysms, ref H+N-S-A-010) was taken with x-ray and testing. To generate a reference image based on the Laplacian algorithm for the image processing which derived from the cerebral blood vessel model was applied to DICOM by Volume ray casting technique. $A^*$ algorithm was used to provide the catheter with a guide wire tracking path. Finally, the result does show the location of the catheter and guide wire providing in the proposed system especially, it is expected to provide a useful guide for future intervention service.

Survey for the Understanding of Elderly Disease and Work Environment for Physical Therapists in Elderly Care Facilities (노인요양시설물리치료사들의 노인복지정책과 노인질환에 대한 이해도 및 직무 환경에 대한 조사)

  • Kim, Soon-Ja;Kim, Jeong-Seon
    • Journal of Korean Physical Therapy Science
    • /
    • v.14 no.1_4
    • /
    • pp.25-36
    • /
    • 2007
  • The results of researching on duties of physical therapist, understanding of elderly diseases and policies related with elderly welfare came out from the survey before beginning of education to physical therapists who attended National Elderly Welfare Physical Therapist Workshop during Sep. 11th to 14th, 2007. They have already understood about long-term elderly care insurance from the policy, and responded that those policies will bring more advantage to elders. On contrary, negative response had reason of low service quality. About elderly care system, there were positive answer of appropriate alternatives to support them, but also other critics had opinion of inevitable choice for living conservation. About understanding of elderly diseases, there were more comprehension of diseases as age gets higher, but most did not understand dementia and paralysis. Past experience and process of medical treatment for their disease were such arthritis, paralysis, broken bone, and dislocation of joint. Prognosis of technical training was mostly answered positively, but linking with other related disease programs were not welcomed. Most respondents thought that professional training were needed. The results of understanding diseases during senescent had high percentage of understanding as age and education was high, and it had eye upon statistics of the survey (p < 0.05) Most of those questioned responded that it is appropriate to have six working days per week and eight hours of daily work, however, present wage is not reasonable. Most of those questioned had negative response of work independence, and had an-swered that there should be certificates needed in related fields. For difficulties during work period, they had hardship instituting direction of treatment by lack of program, level of wage, and physical difficulties. Physical therapists averagely wished to have fewer than thirty patients per therapist. After the research, physical therapists who work in those facilities of elderly care systems agreed on policies, though it should not lower service quality. In addition, they were pros to have elderly care system, yet they are still inevitable option to maintain living. For work environment, the period of work was appropriate, but had different opinions for work independence and regular number of patients. Therefore, there should be more organized treatment program that also should be linked to other practical programs at this beginning point of the policy enforcement and the time that many therapists hope to work in elderly care system.

  • PDF

A CASE REPORT OF DENTINOGENESIS IMPERFECTA (상아질 형성 부전증에 대한 증례보고)

  • Kim, Jae-Gon;Lee, Doo-Cheol;Lee, Seung-Young;Lee, Seung-Ik;Baik, Byeoung-Ju
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.1
    • /
    • pp.1-6
    • /
    • 2000
  • Dentinogenesis imperfecta is an inherited disorder of dentin formation, usually exhibiting an autosomal dominant mode of transmission. Type I dentinogenesis imperfecta occurs in patients afflicted with osteogenesis imperfecta. Type II dentinogenesis imperfecta is not associated with osteogenesis imperfecta. Type III dentinogenesis imperfecta (Brandywine type) occurs in a racial isolate area in the state of Maryland. In all three types, teeth of both dentitions are affected with variable clinical appearances. The teeth are opalescent with the color ranging from bluish-gray to brown to yellowish. The dentin is abnormally soft, providing inadequate functional support to the overlying enamel. Although the enamel is normal, it fractures or chips away easily, exposing the occlusal and incisal dentin. The exposed soft dentin often undergoes rapid and severe functional attrition. The teeth exhibit bulb-shaped crowns with constricted cementoenamel junctions and thin roots. The teeth will exhibit varying stages of obliteration of the coronal and root pulpal chambers. The cementum, periodontal ligament and supporting alveolar bone appear normal. The enamel is normal. The mantle dentin remains nearly normal, whereas the remaining dentin is severely dysplastic. The dentinal tubules are disoriented, irregular, widely spaced, and usually larger than normal.

  • PDF