• Title/Summary/Keyword: Bone screw

Search Result 441, Processing Time 0.028 seconds

A LIGHT AND ELECTRON MICROSCOPIC STUDY OF CHANCES IN INTERMAXILLARY SUTURE DURING THE RAPID MAXILLARY EXPANSION OF YOUNG ADULT DOGS (유성견 급속정중이개시 정중구개봉합부위의 조직학적 변화에 대한 연구)

  • Lee, Doo-Hee;Chung, Kyu-Rhim
    • The korean journal of orthodontics
    • /
    • v.26 no.2 s.55
    • /
    • pp.153-162
    • /
    • 1996
  • Rapid maxillary expansion is widely used for the correction of anteroposterior discrepancies, constriction of the maxillary arch, etc. This experiment was undertaken to examine the serial changes in the osteogenesis as well as the collagen fiber bundles in the intermaxillary suture during the rapid maxillary expansion treatment. Four young female dogs aged 6 to 8 months old and not showing menarche yet were used for the experiment. The maxillary impression of dogs were taken, expansion device cast and Hyrax screw soldered at the midline in the 1st premolar area. RME device was delivered to the dogs and the activation of 0.25 mm per quarter-turn was done 2 times per day for 10 days until 5 mm separation was made. Separation of the maxilla was confirmed by X-ray. The animals were sacrificed on 0, 15, 30, 60 days from the finish of maxillary separation and preparations for light microscopy and surface electron microscopy were made. The sutures were cut into frontal serial sections for examination of the histological reactions. The following results were obtained and the conclusions made. 1. The edges of the two palatal plates bordering the midpalatal suture which at the beginning of the retention period were mainly composed of compact bone, underwent extensive resorption followed by new bone formation and gradually became spongy bone rich in bone marrow which in the 60 day retention animal became the compact bone with short intermaxillary suture space. During this transformation, newly formed trabecular bone tissues were added to the original margin. 2. Throughout the expansion period, the collagen fibers underwent successive changes such as stretching, loss of polarity, and finally fibrillogenesis. Towards the end of the expansion procedure, sharpey's fiber formation in newly formed bones were observed. 3. Bony spicules were found in the initial stage of retention on occlusal topographic X-rays, which later were confirmed to have ossified. 4. Judging from the histological changes occuring during the experimental expansion, excessive expansion will cause an excessive bleeding, and retard the remodeling of intermaxillary suture. According to the above results, the bone remodeling after rapid maxillary expansion was preceded by the migration of migratory cells into the intermaxillary suture area. The bone remodeling phenomena were on-going during the 2 months retention sample.

  • PDF

THE BONE FORMATION AROUND ANODIC OXIDIZED TITANIUM IMPLANTS IN THE TINBIAE OF OVARECTOMIZED RATS (양극산화 표면처리한 티타늄 임플랜트를 난소절제한 백서 경골에 매식 후 주위 골형성에 관한 연구)

  • Park, Sung-Hwan;Jung, Suk-Young;Lee, Jae-Yeol;Kim, Gyoo-Cheon;Shin, Sang-Hun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.34 no.3
    • /
    • pp.306-318
    • /
    • 2008
  • Anodic spark deposition method(ASD) surface treated titanium implant possesses a considerable osteoconductive potential that promoting a high level of implant osseointegration in normal bone. The purpose of this study was to observe the ASD implant's osseointegration in the osteoporosis-induced animal model. Twenty four rats, 10 weeks of age, were ovarectomized and 5 weeks later divided into two groups : ASD implant group and control implant group. Titanium screw implants (diameter; 2.0 mm, length, 3.5 mm; pitch-height, 0.4 mm) were designed for this study. Experimental implants were ASD treated and no treatment on control implants. ASD implants and control implants were placed in to left tibiae of rats. The rats were sacrificed at different time interval(1, 2, 4 and 8 weeks after implantation) for histopathologic observation and immunohisto-chemistrical observation, with collagen type Ⅰ, fibronectin, integrin ${\alpha}_2{\beta}_1$ and integrin ${\alpha}_5{\beta}_1$ antibodies. The results obtained from this study were as follow: 1. Histopathologic findings, overall tissue response and the pattern of bone formation in both groups were similar. In ASD group, more newly formed bone was seen at 1 week and 2weeks than control group. 2. The levels of type Ⅰ collagen and fibronectin expression were the most abundant at 2weeks and decreased gradually in both groups. Fibronectin and type Ⅰ collagen expression in ASD group were stronger than control group but no significance. 3. The levels of integrin ${\alpha}_2{\beta}_1$ and Integrin ${\alpha}_5{\beta}_1$ expression were most abundant at 2 weeks and decreased gradually in both groups. No significant difference was observed in both groups. From this results, anodic oxidized titanium implants were more advantages in early stage of bone formation than control group, but have no significance in tissue responses and late bone formations. It could be stated that although anodic oxidized titanium implant possesses considerable osteoconductive potential but in osteoporotic bone condition dental implant procedure should performed after improving or treating the osteoporotic bone condition.

THE EFFECT OF REPETITIVE DISTRACTION AND COMPRESSION ON NEW BONE FORMATION DURING DISTRACTION (골신장술시 반복적인 압축과 신장 방법이 골형성에 미치는 영향)

  • Yoon, Byung-Wook;Kim, Yeo-Gab;Oh, Jung-Hwan
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.5
    • /
    • pp.407-416
    • /
    • 2008
  • Purpose: The aim of the present study is to evaluate the effect of repetitive distraction and compression on new bone formation during distraction period. Materials and methods: Sixteen healthy rabbits, weighing about 2.5kg, were used in this experiment. A unilateral mandibular osteotomy was performed in the left mandible and the distractor(Track 1 $plus^{(R)}$, Gebruder Martin $GmbH^{(R)}$, Germany) was fixed with four screws (Cross driver screw $TI^{(R)}$, Gebruder Martin $GmbH^{(R)}$, Germany). After 4 days, the mandibles were distracted at a rate of 0.6mm/day for 10 days to obtain the amount of 6mm distraction in the control group(n=4). In the experimental group A(n=6), they were distracted at a rate of 1.2mm/day for 5 days and then compression of 0.6mm length and distraction of 0.6mm per 12 hours were carried out as counter direction for 5 days, relatively. In the experimental group B(n=6), distraction of 1.2mm length and compression of 0.6mm length per 12 hours were repeated for 10 days to obtain the amount of 6mm distraction finally. The experimental animals were sacrificed at 2 and 4 weeks after surgery and block specimens were obtained. With histologic and histomorphometric analysis, we observed the histologic changes of the cells and bone formation after H-E and Masson- Trichrome staining and then, measured Bone Deposition Rate with TOMORO $ScopeEye^{TM}$ ver. 3.5(Olympus, Japan), Results: Histologically, new bone formation was examined in all experimental groups and the control. But, the ability of bone formation of the experimental group A was somewhat better than any other groups. On the histomorphometric analysis, Bone Deposition Rate was higher in the experimental group A$(50.67{\pm}4.36%)$ than in the control group$(45.94{\pm}3.97%)$ and in the experimental group B$(42.68{\pm}5.70%)$. These data showed significant differences statistically(p<0.05). Conclusion: These results show that the distraction osteogenesis using repetitive compression and distraction force in the early consolidation period may be effective for new bone formation.

EFFECT OF CALCIUM AND VITAMIN D SUPPLEMENTATION ON BONE FORMATION AROUND TITANIUM IMPLANT (칼슘과 비타민 D 섭취가 티타늄 임플랜트 주위의 골 형성에 미치는 영향)

  • Park, Kwang-Il;Lee, Jae-Yeol;Hwang, Dae-Seok;Kim, Yong-Deok;Kim, Gyoo-Cheon;Shin, Sang-Hun;Kim, Uk-Kyu;Chung, In-Kyo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.33 no.2
    • /
    • pp.131-138
    • /
    • 2007
  • The purpose of this study was to observe the effect of calcium and vitamin D to the titanium implant osseointegration in animal model. 32 rats, 10 weeks of age, were divided into two group: additional calcium and vitamin D supplementation group and a control group. Titanium screw implant(diameter, 2.0mm; length, 3.5mm; pitch-height 0.4mm) were placed into tibia of 32 rats, 16 in the control group and 16 in the experimental group. The rats were sacrificed at different time interval(1, 2, 4, and 8 weeks after implantation) for histopathologic observation, histomorphometric analysis and immunohistochemistry with osteocalcin and osteopontin antibody. Histopathologically findings, newly formed bone was seen at 1 weeks and became lamellar bone at 2 weeks, and mature trabecullar bone was seen at 4 weeks experimental group. In control group, thickness of regenerated bone increased till 4 weeks gradually and trabecullar bone was seen at 8 weeks. By histomorphometric analysis, bone marrow density was increased significantly at 1 and 2 weeks in experimental group compared to control group. Osteocalcin immunoreactivity was strong at 1 week experimental group and reduced after 4 weeks gradually. But it was continuously weakly from 1 to 4 weeks in control group. Osteopontin immunoreactivity was very strong in newly formed bone from 2 to 8 weeks experimental group. And the amount of osteopontin expression was more abundant in experimental group. The results of this study suggest that calcium and vitamin D supplementation promotes bone healing around dental implants

PCB Instrumentation with Lubboe Bone in Anterior Cervical Interbody Fusion (PCB 기구와 이종골을 이용한 경추체간 전방 유합술)

  • Park, Jeong Hyun;Oh, Seong Hoon;Yi, Hyeong Joong;Kim, Ju Heon;Kim, Young Soo;Ko, Yong;Kim, Kwang Myung;Oh, Suck Jun
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.11
    • /
    • pp.1284-1290
    • /
    • 2001
  • Objective : PCB cervical instrument is a newly introduced fusion device which comprises cervical plate, cage (spacer) and screw system. It is developed to enhance fusion rate and stability, as well as to reduce complications related to hardware failure. We investigated the efficacy of clinical and radiological results of PCB instrument and Lubboc bone. Methods : From August, 1998 to October, 1999, authors performed 54 cases of anterior cervical interbody fusion with PCB instrument and Lubboc bone. Retrospective analysis was undertaken based on clinical and radiological findings. Clinical improvement was evaluated according to Odom's criteria. Cervical plain films and tomography were taken every 2 months to evaluate the degree of interbody fusion and disc height changes. Results : Bone fusion was observed in 36 cases(90%) over 6 months after operation, and during which time there was no significant interval change. There were 3 cases of hardware dislodgement. Disc height was increased significantly and preserved in all cases. Clinical outcome over good degree was seen more than 94% of patients. Conclusion : Longer follow-up period and comparative studies to similar instrument appear to be necessary, but this instrumentation system has shown high fusion rate and fewer adverse effects in our series. We believe this system might be indicated for the treatment of cervical trauma and degenerative disease in selective cases.

  • PDF

Pathologic Fracture of Calcaneus in a Child -A Case Report- (소아 종골에 발생한 병적 골절을 동반한 단순 골낭종 - 1 예 보고 -)

  • Park, Tae-Woo;Cho, Sung-Do;Cho, Young-Sun;Kim, Bum-Soo;Suh, Jae-Hee;Lew, Sog-U;Hwang, Su-Yeon
    • Journal of Korean Foot and Ankle Society
    • /
    • v.5 no.2
    • /
    • pp.156-159
    • /
    • 2001
  • Unicameral bone cysts are benign solitary lesions that occur in the first two decades of life and with a greater frequency in the humerus and femur. The cyst is usually asymptomatic unless a fracture or impending fracture is present. The traditional method of treating unicameral cysts has been curettage with bone graft or steroid injection. Also, pathologic fractures in the calcaneus, unlike in other bones, are reported especially in the children to be nonexistent. In general, closed treatment was recommended for most of the calcaneal fractures in children, but suggested open reduction when joint displacement was severe. We report a case of displaced intraarticular fracture of the calcaneus with unicameral bone cyst in a child treated by classic curettage, allograft and open reduction with screw fixation.

  • PDF

An Anterior Approach to Entire Length of Humerus and to Distal Shaft for Fracture Fixation

  • Lee, Chul-Hyung;Choi, Hyun;Kim, Tae-In;Kim, Jun Beom;Shin, Sang Yeop;Rhee, Seung-Koo
    • Clinics in Shoulder and Elbow
    • /
    • v.19 no.4
    • /
    • pp.223-228
    • /
    • 2016
  • Background: The aim of study was to confirm the clinical effectiveness and results of wide and single anterior approach for fractures occurring along length of humerus. Methods: A total of 23 patients with humeral fracture were enrolled into our study who were able to participate in at least one year of follow-up. Seven patients had segmental comminuted humeral fractures and 16 patients had distal humeral fractures. We made various tractions of the muscles to expose the proximal and the middle third humerus between the biceps and brachialis and the distal humerus by partial splitting of lateral side of biceps through a single incision. Postoperatively, we measured the Mayo elbow performance index (MEPI). Results: we achieved bone union in all 23 patients. Solid union of the bone was achieved at an average 13.9 weeks. Postoperatively, two complications were observed screw loosening and nonunion. Revision surgery was performed in both patients. The patient with bone nonunion was treated using bone grafts. No postoperative infections or peripheral neuropathies were observed. At the final follow-up (average 20 months), we found that the average MEPI functional score of the patients was 91.7 points regardless of the fracture site. Conclusions: Our whole humerus with a single incision was effective for the treatment of segmental comminuted and distal fractures. we believe it is a useful alternative to preexisting methods of fracture fixation.

CLINICAL & RADIOGRAPHIC EVALUATION FOLLOWING DELAYED IMPLANTATION USING REGULAR DIAMETER IMPLANTS IN THE POSTERIOR REGION (구치부에 발치 후 지연 식립된 표준 직경의 임플란트에 대한 임상적, 방사선학적 평가)

  • Choi, Jung-Yong;Lee, Sang-Hwa;Yoon, Hyun-Joong
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.35 no.5
    • /
    • pp.335-339
    • /
    • 2009
  • The purpose of this study was to evaluate clinical and radiographic changes of regular diameter implants placed in the posterior region. A total of 47 standard diameter implants were consecutively placed in the posterior region of 20 partially edentulous patients. The diameters of the implants were 4.1mm (N=35, 74%) and 4.3mm (N=12, 26%), respectively. Peri-implant bone loss and clinical parameters such as mobility, suppuration, swelling, bleeding on probing (BOP) were evaluated at the baseline and?the final follow-up visit. The age of the patients ranged between 24~82 years (mean age: 54.7 years). The cumulative survival rate of the regular diameter implants loaded for a period of 3-24 months (Mean: $11.7{\pm}7.9$ month) was 100%. The average bone loss over the follow-up was $0.36{\pm}0.67\;mm$. Success rate was 95.7%. Only two implants failed (bone loss exceeding 1mm after 1 year of placement). Some prosthetic complications occurred, such as screw loosening (N=1) and dissolution of cementation material (N=2). The present study describes successful outcome following the use of standard-diameter-implants placed in the posterior region, and further comprehensive maintenance practices and follow-up schedules are required.

THE STRESS ANALYSIS OF SUPPORTING TISSUE AND IMPLANT ACCORDING TO CROWN RESTORATIVE MATERIALS AND TYPE OF IMPLANT (수복재료와 임플랜트 종류에 따른 임플랜트 및 지지조직의 응력분포)

  • Choi Chang-Hwan;Oh Jong-Suk;Vang Mong-Sook
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.1
    • /
    • pp.53-67
    • /
    • 2002
  • This study was aimed to analyze the stress distribution of implant and supporting tissue in single tooth implant restoration using Branemark $system^{(R)}$(Nobel Biocare, Gothenberg, Sweden) and Bicon system(Bicon Dental Implants, Boston, MA). Two dimensional finite element analysis model was made at mandibular first premolar area As a crown materials porcelain, ceromer, ADA type III gold alloy were used. Tests have been performed at 25Kgf vertical load on central fossa of crown portion and at 10Kgf load with $45^{\circ}$ lateral direction on cusp inclination. The displacement and stresses of implant and supporting structures were analyzed to investigate the influence of the crown material and the type of implant systems by finite element analysis. The results were obtained as follows : 1. The type of crown material influenced the stress distribution of superstructure, but did not influence that of the supporting alveolar bone. 2. The stress distribution of ceromer and type III gold alloy and porcelain is similar. 3. Stress under lateral load was about twice higher than that of vertical load in all occlusal restorative materials. 4. In Bicon system, stress concentration is similar in supporting bone area but CerOne system generated about 1.5times eater stress more in superstructure material. 5. In Branemark models, if severe occlusal overload is loaded in superstvucture. gold screw or abutment will be fractured or loosened to buffer the occlusal overload but in Bicon models such buffering effect is not expected, so in Bicon model, load can be concentrated in alveolar bone area.

Effects of recycling on the biomechanical characteristics of retrieved orthodontic miniscrews

  • Yun, Soon-Dong;Choi, Sung-Hwan;Cha, Jung-Yul;Yu, Hyung-Seog;Kim, Kwang-Mahn;Kim, Jin;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.47 no.4
    • /
    • pp.238-247
    • /
    • 2017
  • Objective: The aim of this study was to compare recycled and unused orthodontic miniscrews to determine the feasibility of reuse. The comparisons included both miniscrews with machined surfaces (MS), and those with etched surfaces (ES). Methods: Retrieved MS and ES were further divided into three subgroups according to the assigned recycling procedure: group A, air-water spray; group B, mechanical cleaning; and group C, mechanical and chemical cleaning. Unused screws were used as controls. Scanning electron microscopy, energy-dispersive X-ray spectrometry, insertion time and maximum insertion torque measurements in artificial bone, and biological responses in the form of periotest values (PTV), bone-implant contact ratio (BIC), and bone volume ratio (BV) were assessed. Results: Morphological changes after recycling mainly occurred at the screw tip, and the cortical bone penetration success rate of recycled screws was lower than that of unused screws. Retrieved ES needed more thorough cleaning than retrieved MS to produce a surface composition similar to that of unused screws. There were no significant differences in PTV or BIC between recycled and unused screws, while the BV of the former was significantly lower than that of the latter (p < 0.05). Conclusions: These results indicate that reuse of recycled orthodontic miniscrews may not be feasible from the biomechanical aspect.