The effect of low-speed drilling without irrigation on heat generation: an experimental study

  • Oh, Ji-Hyeon;Fang, Yiqin;Jeong, Seung-Mi;Choi, Byung-Ho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제42권1호
    • /
    • pp.9-12
    • /
    • 2016
  • Objectives: In this study we evaluated heat generation during the low-speed drilling procedure without irrigation. Materials and Methods: Ten artificial bone blocks that were similar to human D1 bone were used in this study. The baseline temperature was $37.0^{\circ}C$. We drilled into 5 artificial bone blocks 60 times at the speed of 50 rpm without irrigation. As a control group, we drilled into an additional 5 artificial bone blocks 60 times at the speed of 1,500 rpm with irrigation. The temperature changes during diameter 2 mm drilling were measured using thermocouples. Results: The mean maximum temperatures during drilling were $40.9^{\circ}C$ in the test group and $39.7^{\circ}C$ in the control group. Even though a statistically significant difference existed between the two groups, the low-speed drilling did not produce overheating. Conclusion: These findings suggest that low-speed drilling without irrigation may not lead to overheating during drilling.

Self-drilling 방식의 마이크로임플란트 식립에 의해 발생하는 피질골 스트레인의 유한요소해석 (Finite element analysis of cortical bone strain induced by self-drilling placement of orthodontic microimplant)

  • 박진서;유원재;경희문;권오원
    • 대한치과교정학회지
    • /
    • 제39권4호
    • /
    • pp.203-212
    • /
    • 2009
  • 골밀도가 높고 두꺼운 피질골에 마이크로임플란트를 self-drilling 방식으로 식립하는 경우 과도한 수준의 골부하 (bone loading)가 발생할 위험이 있으며 이는 인접골의 정상적인 골개형(bone remodeling)에 장애를 초래할 수 있다. 이에, 본 연구에서는 유한요소해석으로 두께 1.0 mm의 피질골에 Absoanchor SH1312-7 마이크로임플란트((주)덴토스, 대구, 대한민국)가 self-drilling 방식으로 식립되는 과정(10회전, 식립깊이 5 mm)을 모사(simulation)하였으며 식립 단계별로 피질골에 발생되는 스트레인을 조사하였다. 식립중 마이크로임플란트 첨부의 절삭연(cutting flute)에 의한 골삭제로 생기는 나사길(threaded groove)의 치수를 얻기 위하여 가토 경골에 마이크로임플란트를 식립/제거한 후 Micro CT (Explore Locus RS, GE Healthcare, Ontario, Canada)를 이용하여 기하형상을 측정하였으며 이를 치밀골의 유한요소모델에 반영하였다. 해석결과, 치밀골에 발생되는 스트레인은 임플란트 식립깊이에 따라 증가하였고, 초기단계에서 나사산에 인접한 골에 국한되던 과부하 부위(스트레인이 4,000${\mu}$-strain을 상회하는 영역)가 식립깊이 증가에 따라 인접골 전체, 즉 나사산 인접부는 물론 골(valley) 부위에 접하는 모든 영역으로 확장되었다. 본 연구를 통해, self-drilling 방식으로 마이크로임플란트를 식립할 때 치밀골에 발생하는 스트레인 크기는 생리적인 골개형을 저해할 수 있는 수준임을 확인할 수 있었다.

임플랜트 식립부위 형성시 골조직의 온도변화에 관한 연구 (A STUDY ON THE TEMPERATURE CHANGES OF BONE TISSUES DURING IMPLANT SITE PREPARATION)

  • 김평일;김영수;장경수;김창회
    • 대한치과보철학회지
    • /
    • 제40권1호
    • /
    • pp.1-17
    • /
    • 2002
  • The purpose of this study is to examine the possibility of thermal injury to bone tissues during an implant site preparation under the same condition as a typical clinical practice of $Br{\aa}nemark$ implant system. All the burs for $Br{\aa}nemark$ implant system were studied except the round bur The experiments involved 880 drilling cases : 50 cases for each of the 5 steps of NP, 5 steps of RP, and 7 steps of WP, all including srew tap, and 30 cases of 2mm twist drill. For precision drilling, a precision handpiece restraining system was developed (Eungyong Machinery Co., Korea). The system kept the drill parallel to the drilling path and allowed horizontal adjustment of the drill with as little as $1{\mu}m$ increment. The thermocouple insertion hole. that is 0.9mm in diameter and 8mm in depth, was prepared 0.2mm away from the tapping bur the last drilling step. The temperatures due to countersink, pilot drill, and other drills were measured at the surface of the bone, at the depths of 4mm and 8mm respectively. Countersink drilling temperature was measured by attaching the tip of a thermocouple at the rim of the countersink. To assure temperature measurement at the desired depths, 'bent-thermocouples' with their tips of 4 and 8mm bent at $120^{\circ}$ were used. The profiles of temperature variation were recorded continuously at one second interval using a thermometer with memory function (Fluke Co. U.S.A.) and 0.7mm thermocouples (Omega Co., U.S.A.). To simulate typical clinical conditions, 35mm square samples of bovine scapular bone were utilized. The samples were approximately 20mm thick with the cortical thickness on the drilling side ranging from 1 to 2mm. A sample was placed in a container of saline solution so that its lower half is submerged into the solution and the upper half exposed to the room air, which averaged $24.9^{\circ}C$. The temperature of the saline solution was maintained at $36.5^{\circ}C$ using an electric heater (J. O Tech Co., Korea). This experimental condition was similar to that of a patient s opened mouth. The study revealed that a 2mm twist drill required greatest attention. As a guide drill, a twist drill is required to bore through a 'virgin bone,' rather than merely enlarging an already drilled hole as is the case with other drills. This typically generates greater amount of heat. Furthermore, one tends to apply a greater pressure to overcome drilling difficulty, thus producing even greater amount heat. 150 experiments were conducted for 2mm twist drill. For 140 cases, drill pressure of 750g was sufficient, and 10 cases required additional 500 or 100g of drilling pressure. In case of the former. 3 of the 140 cases produced the temperature greater than $47^{\circ}C$, the threshold temperature of degeneration of bone tissue (1983. Eriksson et al.) which is also the reference temperature in this study. In each of the 10 cases requiring extra pressure, the temperature exceeded the reference temperature. More significantly, a surge of heat was observed in each of these cases This observations led to addtional 20 drilling experiments on dense bones. For 10 of these cases, the pressure of 1,250g was applied. For the other 10, 1.750g were applied. In each of these cases, it was also observed that the temperature rose abruptly far above the thresh old temperature of $47^{\circ}C$, sometimes even to 70 or $80^{\circ}C$. It was also observed that the increased drilling pressure influenced the shortening of drilling time more than the rise of drilling temperature. This suggests the desirability of clinically reconsidering application of extra pressures to prevent possible injury to bone tissues. An analysis of these two extra pressure groups of 1,250g and 1,750g revealed that the t-statistics for reduced amount of drilling time due to extra pressure and increased peak temperature due to the same were 10.80 and 2.08 respectively suggesting that drilling time was more influenced than temperature. All the subsequent drillings after the drilling with a 2mm twist drill did not produce excessive heat, i.e. the heat generation is at the same or below the body temperature level. Some of screw tap, pilot, and countersink showed negative correlation coefficients between the generated heat and the drilling time. indicating the more the drilling time, the lower the temperature. The study also revealed that the drilling time was increased as a function of frequency of the use of the drill. Under the drilling pressure of 750g, it was revealed that the drilling time for an old twist drill that has already drilled 40 times was 4.5 times longer than a new drill The measurement was taken for the first 10 drillings of a new drill and 10 drillings of an old drill that has already been used for 40 drillings. 'Test Statistics' of small samples t-test was 3.49, confirming that the used twist drills require longer drilling time than new ones. On the other hand, it was revealed that there was no significant difference in drilling temperature between the new drill and the old twist drill. Finally, the following conclusions were reached from this study : 1 Used drilling bur causes almost no change in drilling temperature but increase in drilling time through 50 drillings under the manufacturer-recommended cooling conditions and the drilling pressure of 750g. 2. The heat that is generated through drilling mattered only in the case of 2mm twist drills, the first drill to be used in bone drilling process for all the other drills there is no significant problem. 3. If the drilling pressure is increased when a 2mm twist drill reaches a dense bone, the temperature rises abruptly even under the manufacturer-recommended cooling conditions. 4. Drilling heat was the highest at the final moment of the drilling process.

Drilling force and speed for mandibular trabecular bone in oral implant surgery

  • bin Kamisan, Mohammad Aimaduddin Atiq;Yokota, Kenichiro;Ueno, Takayuki;Kinoshita, Hideaki;Homma, Shinya;Yajima, Yasutomo;Abe, Shinichi;Takano, Naoki
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • 제3권1호
    • /
    • pp.15-26
    • /
    • 2016
  • Based on a survey done recently in Japan, 30 percent of the serious accidents occurred in oral implant surgery were concerned with the mandibular canal and 3/4 of them were related to drilling. One of the reasons lies in the lack of the education system. To overcome this problem, a new educational system focusing on drilling the mandibular trabecular bone has been developed mainly for dental college students in the form of an oral implant surgery training simulator that enables student to sense the reaction force during drilling. On the other hand, the conventional system uses polymeric model. Based on these systems, two approaches were proposed; the evaluation by experienced clinicians using the simulator, and experimental works on the polymeric model. Focusing on the combination of the drilling force sensed and drilling speed obtained through both approaches, the results were compared. It was found that the polymeric models were much softer especially near the mandibular canal. In addition, the study gave us an insight of the understanding in bone quality through tactile sensation of the drilling force and speed. Furthermore, the clinicians positively reviewed the simulator as a valid tool.

The effect of implant drilling speed on the composition of particle collected during site preparation

  • Jeong, Chang-Hee;Kim, Do-Young;Shin, Seung-Yun;Hong, Jong-Rak;Kye, Seung-Beom;Yang, Seung-Min
    • Journal of Periodontal and Implant Science
    • /
    • 제39권sup2호
    • /
    • pp.253-259
    • /
    • 2009
  • Purpose: This study was aimed to evaluate the effect of implant drilling speed on the composition of particle size of collected bone debris. Methods: $Br{\aa}nemark$ $System^{(R)}$ drills were used to collect bone debris from 10 drilling holes (1 unit) at 1,500 rpm (Group A) and 800 rpm (Group B) in bovine mandible. After separating particles by size into > 500 ${\mu}m$, between 250 ${\mu}m$ and 500 ${\mu}m$, and < 250 ${\mu}m$ fractions, particle wet volume, dry volume, and weight were measured and the proportion of 3 fractions of bone debris to total wet volume, dry volume and weight was calculated as wet volume % , dry volume % and weight %. Results: No significant differences were found between Group A and B in wet volume, dry volume, and weight. However, of >500 ${\mu}m$ fractions, Group B had significantly higher wet volume %(P = 0.0059) and dry volume %(P = 0.0272) than in Group A. Conclusions: The drilling speed influenced the composition of particle size in collected drilling bone debris. The drilling in 800 rpm produced the more percentage of large particles than in 1,500 rpm. However, the drilling speed didn't effect on total volume of and weight of bone debris.

치과 임플랜트 식립시 관주에 따른 골 천공 기구의 열 발생에 관한 연구 (A STUDY ON THE HEAT GENERATION OF BONE DRILLING BURS ACCORDING TO IRRIGATION DURING IMPLANTATION OF DENIAL IMPLANT)

  • 문은수;임헌송;조인호
    • 대한치과보철학회지
    • /
    • 제37권4호
    • /
    • pp.433-453
    • /
    • 1999
  • There are a lot of elements affecting the success of implant prosthesis. The quality of surgical procedure is considered as one of the key factors. To avoid the excess heat generation is an important element of successful osseointegration and it can be achieved by using a gentle surgical technique with a sharp instrument in bone drilling. This study was performed to measure and analyze comparatively the heat transmitted to sur-rounding bone at a distance of 0.5mm from the periphery of the drill hole in each drilling stage. The results were as follows. In standard system, the temperature of surrounding bone tissue ranged from $29.2^{\circ}C\;to\;48.3^{\circ}C$ with irrigation and from $34.6^{\circ}C\;to\;84.3^{\circ}C$ without irrigation. And in wide system, the temperature of surrounding bone tissue ranged from $29.5^{\circ}C\;to\;52.5^{\circ}C$ with irrigation and from $34.8^{\circ}C\;to\;87.8^{\circ}C$ without irrigation. And the temperature ranges exceeded the threshold without irrigation, while showing less than the threshold by the cooling effect of irrigation. In comparing standard system with wide system, although there was no significant difference, ${\phi}4.3mm$ pilot and ${\phi}4.3mm$ twist drill of wide system showed high value and wide system showed slightly high elevation of temperature in all depth in fixture installation. In the finite element analysis, the calculated value by the Fourier's cooling law were applied to the bone drilling surface. And through analysis using different irrigation temperatures at $28^{\circ}C,\;15^{\circ}C\;and\;5^{\circ}C$, and according to the time. The result was that the cooling water at least below $15^{\circ}C$ was required to maintain the temperature of surrounding bone less than threshold in bone drilling, the cooling water below $5^{\circ}C$ was required to gain more sufficient cooling effect, and cooling over 5 seconds was needed after bone drilling for sufficient effect.

  • PDF

하악골의 치조골 골삭제를 위한 동적 제약 기구부의 성능에 관한 연구 (A Study on the Performance of Dynamic Restraint Manipulator for Drilling Alveolar Bone in Mandible)

  • 김광호;이동운;정상화
    • 한국기계가공학회지
    • /
    • 제19권12호
    • /
    • pp.105-112
    • /
    • 2020
  • The increase in the edentulous jaw which occurs in the aged population has led to personal dental health concerns. In the case of dental implant surgery, the duration of a patient's recovery depends on the surgical plan and their physicical ability. A device may be required to assist a physician in controlling vibration reduction of free-hand drilling and prescribing a good treatment plan that is suitable for the patient's condition. In this work, an artificial tooth-root implant assistant manipulator was studied. The structure and the vibration analysis of the dynamic restraint manipulator that is for drilling the alveolar bone in the mandible bone were performed, and the structural stability was analyzed. Further, a virtual prototype of an artificial tooth-root implant assisted manipulator was fabricated and tested. Hence, the state of the Remote Center of Motion (RCM) point and the driving state of the manipulator were confirmed. Furthermore, the drilling experiments were performed by using materials similar to a human jawbone in order to evaluate the performance of the drilling process that is operated using the assistant manipulator.

Self drilling과 Self-tapping microscrew implants의 조직학적 및 생역학적인 비교 (Histologic and biomechanical characteristics of orthodontic self-drilling and self-tapping microscrew implants)

  • 박효상;슈엔;정성화
    • 대한치과교정학회지
    • /
    • 제36권4호
    • /
    • pp.295-307
    • /
    • 2006
  • 이 연구의 목적은 교정용 고정원으로 사용된 self-drilling과 self-tapping microscrew implants를 조직학적 및 생역적으로 비교하는 것이다. 28 마리의 가토에 112개의 microscrew implants (56개의 self-drilling microscrew implants 와 56개의 self-tapping microscrew implants)를 식립하였다. Self-tapping microscrew implants는 0.9 mm 드릴로서 홈을 형성한 후 식립하였고 self-drilling microscrew implants는 홈을 형성하지 않고 바로 식립하였다. 교정력은 식립 직후 바로 NiTi coil spring을 연결하여 가하였으며 일부는 교정력을 가하지 않았고 일부는 100 gm정도의 약한 교정력을 일부는 200 gm정도의 강한 교정력을 가하였다. 실험동물은 3주 혹은 5주에 희생하였으며 72개의 비탈회 표본을 만들어 전반적인 조직학적 관찰과 조직 계측을 시행하였다. 토크 게이지로 최대 식립 토크와 최대 제거 토크를 측정하였다. 모든 microscrew implants는 실험기간 동안 안정되게 유지되었고 최대 제거 토크의 측정에는 self-drilling과 self-tapping microscrew implants 사이에 통계학적으로 유이한 차이가 없었다. 조직 관찰에서 self-tapping microscrew implants에서 골 임프란트 계면에 골결손이 더 많았고 5주에서는 새로이 형성된 미성숙 골이 더 많았다. Self-drilling microscrew implants에서 골표면 혹은 골내막으로의 골 형성이 많이 관찰되었으나 5주에서는 흡수되는 양상을 보였다. 3주에서는 self-drilling microscrew implants가 더 많은 골접촉을 보였으나 5주에서는 두 군사이에 차이가 관찰되지 않았다. 이 결과는 두 방법이 모두 microscrew implant의 식립에 사용될 수 있음을 시사하나 self-tapping microscrew implants의 경우 초기에는 약한 힘을 가하는 것이 좋을 것으로 생각된다.

Bone cutting capacity and osseointegration of surface-treated orthodontic mini-implants

  • Kim, Ho-Young;Kim, Sang-Cheol
    • 대한치과교정학회지
    • /
    • 제46권6호
    • /
    • pp.386-394
    • /
    • 2016
  • Objective: The objective of the study was to evaluate the practicality and the validity of different surface treatments of self-drilling orthodontic mini-implants (OMIs) by comparing bone cutting capacity and osseointegration. Methods: Self-drilling OMIs were surface-treated in three ways: Acid etched (Etched), resorbable blasting media (RBM), partially resorbabla balsting media (Hybrid). We compared the bone cutting capacity by measuring insertion depths into artificial bone (polyurethane foam). To compare osseointegration, OMIs were placed in the tibia of 25 rabbits and the removal torque value was measured at 1, 2, 4, and 8 weeks after placement. The specimens were analyzed by optical microscopy, scanning electron microscopy (SEM), and energy dispersive X-ray spectroscopy (EDS). Results: The bone cutting capacity of the etched and hybrid group was lower than the machined (control) group, and was most inhibited in the RBM group (p < 0.05). At 4 weeks, the removal torque in the machined group was significantly decreased (p < 0.05), but was increased in the etched group (p < 0.05). In the hybrid group, the removal torque significantly increased at 2 weeks, and was the highest among all measured values at 8 weeks (p < 0.05). The infiltration of bone-like tissue surface was evaluated by SEM, and calcium and phosphorus were detected via EDS only in the hybrid group. Conclusions: Partial RBM surface treatment (hybrid type in this study) produced the most stable self-drilling OMIs, without a corresponding reduction in bone cutting capacity.