• 제목/요약/키워드: Bone Implant Contact

검색결과 256건 처리시간 0.029초

Histomorphometric Study of Implants Initially Stabilized through Bone Graft Packing into the Osteotomy before Implant Placement in Case of Wide Defects

  • Lee, Wang-Jae;Hong, Ki-Seok
    • Journal of Korean Dental Science
    • /
    • 제4권2호
    • /
    • pp.67-72
    • /
    • 2011
  • Purpose: This study sought to evaluate the effects of bone graft wedging on the initial stability of implants in bone sites of unfavorable quality. Materials and Methods: Three male beagle dogs were used in this study. Osteotomies were performed with parallel drills (${\O}4.1{\times}10mm$), and fixtures (${\O}3.3{\times}8mm$) were placed. The control group was given implants without bone graft. Experiment group A was given implants with minimal initial stability using autobone grafts, whereas experiment group B was given xenografts. Groups were also divided by healing times at 4, 8, and 12 weeks. Results: All implants in the control group failed to osseointegrate. On the other hand, all implants in the experiment groups were clinically well-maintained during the entire experiment period. After 4, 8, and 12 weeks, bone-to-implant contact (BIC) ratio and implant stability quotient (ISQ) increased in the experiment groups. The differences between experiment groups A and B were not statistically significant, however. Conclusion: In unfavorable bone regions for dental implants, bone graft packing into the osteotomy prior to implant placement secured minimal initial stability and showed reasonable BIC ratios and ISQ values throughout the study period.

표면처리가 다른 5종 임플랜트의 안정성에 관한 연구 (A STUDY ON THE STABILITY OF 5 DIFFERENT SURFACE TREATMENT METHODS TO DENIAL IMPLANT USING RESONANCE FREQUENCY AND HISTOMORPHOMETRIC ANALYSIS)

  • 김선종;신상완;정성민;류재준
    • 대한치과보철학회지
    • /
    • 제43권1호
    • /
    • pp.78-94
    • /
    • 2005
  • Purpose. The purpose of this study was to compare the effects of various surface treatments by measuring resonance frequency and histomorphometric analyses. Material and methods. In 5 adult dogs, the mandibular premolar were extracted. Six months later, 30 screw titanium implants (Dentium Co., Seoul, Korea) 6mm in length and 3.4mm in diameter, were placed in the mandibles of 5 dogs. Implants were divided into five groups following to surface treatment methods ; Group 1 is machined controls, Group 2 is sandblasted with large grit and acid-etched (SLA), Group 3 is anodized (Autoelectric Co., Korea, 660Hz, Duty10), Group 4 is hydroxyapatite(HA) coated by ion beam assisted deposition(E-beam), Group 5 is hydroxyapatite(HA) coated with Sol-gel coating process. Resonance frequency was measured implant placement immediately, and 3, 6 weeks and 10 weeks of healing perods. With the animal subject's sacrifice 10 weeks after implantation, implants were removed on bloc and histologic and computer-based histomorphometric analyses were performed. Histomorphometric analysis involved quantification of the entire bone to metal contact around the implants. Statistical analyses were performed using the SPSS for Windows (ver. 9.0 SPSS Inc.) Statistical differences were considered significant at P<0.05. Results. The results were as follows : 1) In five groups, mean value of resonance frequency analysis(RFA) were highest in group 5 (Sol-gel implant) at implantation and those of group 4 (E-beam)was highest at 10 weeks . but there was no correlation between surface treatments and RFA. 2) In all surface treatment groups, the RFA values of implants decreased until 3 weeks and increased to 10 weeks. 3) The percentage of direct bone-to-implant contact (BIC) had statistical significance between five groups in cancellous bone, (P<0.05) the percentage of bone density inside the thread had no statistical significance between five groups. (P>0.05) 4) There was a significant difference between cortical bone and cancellous bone in BIC. (P<0.05) and bone density. (P<0.05) 5) There was a correlation between the RFA value of implants at 10 weeks and BIC in cancellous bone, and between the RFA value of implants at 10 weeks and bone density in cortical bone. (P<0.05). Conclusions. These results indicate that surface treatment does not affect the implant stability in case of good bone quality.

타이타늄 임프란트 골유착시 TGF-$\beta$와 IGF-I의 발현 (EXPRESSION OF TGF-$\beta$ AND IGF-I DURING OSSEOINTEGRATION OF TITANIUM IMPLANT)

  • 이인웅;송현철;지유진
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제27권2호
    • /
    • pp.123-130
    • /
    • 2005
  • Many of the molecular and genotypic events taking place at the osteoblast cell level during bone-implant integration are still largely unknown. The objective of this study was to examine expression patterns of TGF-$\beta$ and IGF-I related genes during bone-implant integration. Titanium implants with machined surface were placed into 8 rabbit tibias. At 3rd, 7th, 14th, 28th day after implantation, the expression pattern of TGF-$\beta$ and IGF-I genes in bone with or without implant was examined using reverse transcriptase-polymerase chain reaction (RT-PCR). At the same time, histomorphometric analysis was evaluated, respectively. The bone-to-implant contacts (BIC) of experimental groups were 5.2%, 6.2%, 6.6%, 24.6% at 3rd, 7th, 14th, 28th day. This indicated that newly formed bone increased at the implant surface in bone marrow space after implantation. The expressions of TGF-$\beta$ and IGF-I were higher in implantation groups than untreated control groups during all experimental days. The increased expression of TGF-$\beta$ and IGF-I genes may be associated with the increased bone-to-implant contact. This result provided the evidence for existing biologic differences in tissue response after implantation and helped us to understand molecular biologic processes in tissue-implant integration.

임프란트 식립시 이식된 탈회골기질을 함유한 이식재의 골형성에 대한 연구 (A STUDY ON THE BONE FORMATION OF GRAFT MATERIAL CONTAINING DEMINERALIZED BONE MATRIX WITH A SIMULTANEOUS INSTALLATION OF IMPLANT)

  • 김여갑;윤병욱;류동목;이백수;오정환;권용대
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제31권6호
    • /
    • pp.481-491
    • /
    • 2005
  • Purpose: The aim of the present study is to evaluate the effect of autogenous bone and allograft material coverd with a bioresorbable membrane on bone regeneration after a simultaneous installation of implant. Materials and methods: Twelve healthy rabbits, weighing about $3{\sim}4$ kg, were used in this experiment. Following impalnt(with 3.25 mm diameter and 8 mm length) site preparation by surgical protocol of $Oraltronics^{(R)}$, artificial bony defect, 5mm sized in height and depth, was created on femoral condyle using trephine drill(with 5 mm diameter and 5 mm length). Then implant was inserted. In the experimental group A, the bony defect was filled with autogenous particulated bone and coverd with $Lyoplant^{(R)}$ resorbable membrane. In the experimental group B, the bony defect was filled with allograft material(Orthoblast $II^{(R)}$) containing demineralized bone matrix and covered with $Lyoplant^{(R)}$. In the control group, without any graft materials, the bony defect was covered with $Lyoplant^{(R)}$. The experimental group A and B were divided into each 9 cases and control group into 3 cases. The experimental animals were sacrificed at 3, 6 and 8 weeks after surgery and block specimens were obtained. With histologic and histomorphometric analysis, we observed the histologic changes of the cells and bone formation after H-E staining and then, measured BIC and bone density with KAPPA Image $Base^{(R)}$ system. Results: As a result of this experiment, bone formation and active remodeling process were examined in all experimental groups and the control. But, the ability of bone formation of the experimental group A was somewhat better than any other groups. Especially bone to-implant contact fraction ranged from 12.7% to 43.45% in the autogenous bone group and from 9.02% to 29.83% in DBM group, at 3 and 8 weeks. But, bone density ranged from 15.67% to 23.17% in the autogenous bone group and from 25.95% to 46.06% in DBM group at 3 and 6 weeks, respectively. Although the bone density of DBM group was better than that of autogenous bone group at 3 and 6weeks, the latter was better than the former at 8 weeks, 54.3% and 45.1%, respectively. Therefore these results showed that DBM enhanced the density of newly formed bone at least initially.

Benefits of mineralized bone cortical allograft for immediate implant placement in extraction sites: an in vivo study in dogs

  • Orti, Valerie;Bousquet, Philippe;Tramini, Paul;Gaitan, Cesar;Mertens, Brenda;Cuisinier, Frederic
    • Journal of Periodontal and Implant Science
    • /
    • 제46권5호
    • /
    • pp.291-302
    • /
    • 2016
  • Purpose: The aim of the present study was to evaluate the effectiveness of using a mineralized bone cortical allograft (MBCA), with or without a resorbable collagenous membrane derived from bovine pericardium, on alveolar bone remodeling after immediate implant placement in a dog model. Methods: Six mongrel dogs were included. The test and control sites were randomly selected. Four biradicular premolars were extracted from the mandible. In control sites, implants without an allograft or membrane were placed immediately in the fresh extraction sockets. In the test sites, an MBCA was placed to fill the gap between the bone socket wall and implant, with or without a resorbable collagenous membrane. Specimens were collected after 1 and 3 months. The amount of residual particles and new bone quality were evaluated by histomorphometry. Results: Few residual graft particles were observed to be closely embedded in the new bone without any contact with the implant surface. The allograft combined with a resorbable collagen membrane limited the resorption of the buccal wall in height and width. The histological quality of the new bone was equivalent to that of the original bone. The MBCA improved the quality of new bone formation, with few residual particles observed at 3 months. Conclusions: The preliminary results of this animal study indicate a real benefit in obtaining new bone as well as in enhancing osseointegration due to the high resorbability of cortical allograft particles, in comparison to the results of xenografts or other biomaterials (mineralized or demineralized cancellous allografts) that have been presented in the literature. Furthermore, the use of an MBCA combined with a collagen membrane in extraction and immediate implant placement limited the extent of post-extraction resorption.

기능적 부하 후 임플란트 주변의 골 흡수에 대한 방사선학적 연구 (STUDY ON RADIOGRAPHIC EVALUATION OF MARGINAL BONE LOSS AROUND OSSEOINTEGRATED IMPLANT AFTER FUNCTIONAL LOADING)

  • 최수진;지영덕;고세욱
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제35권4호
    • /
    • pp.240-247
    • /
    • 2009
  • Purpose: The purpose of this study was to evaluate marginal bone loss to the bone crest functionally loaded for up to eighteen months and also with regard to other variables of interest. Material and Methods: 135 endosseous implants(GS II, Osstem, South Korea) were placed in 35 patients. The design of GS II implant is straight with the microthread. Radiographic examinations were conducted at baseline (implant loading) and 3, 6, 9, 12 and 18 months after loading. Marginal bone level measurement was made from the reference point to the lowest observed point of contact of the marginal bone with the fixture. The reference point of the fixture was the border between the blasted surface and machined surface of the fixture. Results: Implants were on function for a mean 12.7 months(range, 3?18 months). For the 56 maxillary and 79 mandibular implants, mean marginal bone loss was 0.68 mm and 0.70 mm. Implants placed maxillary posterior area displayed more crestal bone loss than the other position. The difference between mesial and distal bone levels was statistically significant (p<0.05) with respective means of 0.51 mm and 0.62 mm. Also, The difference between bone graft group and no-bone graft group was statistically significant(p<0.05) with respective means of 0.38 mm and 0.66 mm. But no statistically significant influence of sex, type of surgery(one or two stage surgery), the implant length was observed(p>0.05). Conclusion: This study indicates the amount of marginal bone loss around implant has maintained a relative stable during follow-up periods.

임플란트 매식시 골형성단백질 및 탈회동종골 사용에 따른 골재생 및 계면에 대한 연구 (EVALUATION OF THE INTERFACES BETWEEN IMPLANTS AND REGENERATED BONE USING BONE MORPHOGENETIC PROTEIN AND DEMINERALIZED FREEZE-DRIED BONE)

  • 강상규;이종호;김명진
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제26권1호
    • /
    • pp.24-39
    • /
    • 2000
  • Various methods and graft materials have been used to fill in the defect adjacent to the implants and considered as clinically acceptable. But it is not clear whether the regenerated bone increases the implant-bone contact and supports the implant. The purpose of this study is to evaluate regenerated bone surrounding implants using bone morphogenetic protein(BMP) and demineralized freeze-dried bone(DFDB), and the interfaces between implants and regenerated bone. bBMP was extracted and partially purified from the bovine bone matrix using heparine chromatography. Demineralized freeze-dried bone was made from the dog. Inactive insoluble collagenous bone matrix(IBM) of dog was used as carrier of bBMP. Interfaces of titanium coated epoxy resin implants were processed for demineralized section for transmission electron microscopy(TEM) and those of screw type implants were for nondemineralized section for light and fluoromicroscopic examination. Implants were inserted in the inferior border of mandible of adult dogs and artificial bony defects($3{\times}3{\times}4mm$) were made at the mesial and distal side of implants. Defects were filled with BMP(BMP group) and DFDB(DFDB group). For the fluoromicroscopic examination, the fluorescent dyes(oxytetracycline, calcein green, alizarin red) were injected 2, 4, 6, 8, 12 weeks after implantation. The experimental animals were sacrificed at the 6th and the 12th week and their mandible were extirpated and processed for examination with light microscopy, fluoromicroscopy and TEM. The obtained results were as follows : 1. By the light microscopic findings, the defects were filled with woven bone at the 6th week and compact bone at the 12th week, and the osseointegrations were seen in both groups. There was no histological difference between them. 2. On the basis of the histomorphometric analysis, BMP group(6th week: 40.25%, 12th week: 56.04%) had higher bony contact ratio than DFDB group(38.37%, 42.63%). There was significant difference between two groups at the 12th week(p<0.05). 3. The amount of bone formation in BMP group was more prominent than in DFDB group. Significant difference was noted among two groups at the 6th and the 8th week(p<0.05). 4. By the transmission electron microscopic findings, $0.4-2{\mu}m$ soft tissue layer was found in adjacent to the interfaces and over the collagen fibrils of bone at the 6th week. However, about 100nm amorphous layer was noted at the interface or collagen fibrils directly extended to the titanium surface at the 12th week. There was no significant difference between two groups. 5. These results suggest that BMP and DFDB can be used as good graft materials in the regeneration of bone adjacent to implant, and BMP is more valuable as a bone inducer than DFDB.

  • PDF

비글견 경골에서 임플란트 식립 시 혈소판 농축 혈장이 골형성에 미치는 영향 (The effect of platelet rich plasma in bone formation on implant installation in the tibia of beagle dogs)

  • 국민석;정승곤;심경미;강성수;박홍주;유선열;오희균
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제36권2호
    • /
    • pp.71-77
    • /
    • 2010
  • Introduction: The purpose of this study is to evaluate the effect of platelet rich plasma in bone formation and osseointegration of implant installed in the bone marrow space. Materials and Methods: Five beagle dogs were used as experimental animals. Two implants were installed on each tibia in the dogs. Implants of the control group were installed with no additional graft. Those of the experimental group 1 were installed with autogenous bone graft from the ilium autogenous bone. Platelet rich plasma (PRP) alone was used in experimental group 2 and the mixture of PRP and autogenous bone was used in experimental group 3. The animals were sacrificed at 8 weeks after implantation. The parts of tibia containing implant were harvested and radiographs were taken for radiographic examination. The specimens were prepared for histological examination and histomorphometric analysis of implant-bone contact ratios. Results: 1. All implants showed sufficient osseointegration in the cortical bone radiographically and histologically, but osseointergration in the marrow space was not satisfactory. 2. Histomorphometrically, the implant-bone contact ratios in the bone marrow was sequentially high in the experimental group 3 (autogenous bone + PRP group), group 1 (autogenous bone group), group 2 (PRP group), and control group (non-additive). 3. It was verified that there was statistical significance between two experimental groups (group 1 and 3) and the other groups (group 2 and control group). (P<0.005) 4. However, there was no statistical significance between group 3 and group 1, also group 2 and control group respectively. Conclusion: These results suggest that platelet rich plasma is effective to osseointegration in the implant installation but there is no statistical significance.

The effect of fibronectin-coated implant on canine osseointegration

  • Kim, Sung-Tae;Myung, Woo-Chun;Lee, Jung-Seok;Cha, Jae-Kook;Jung, Ui-Won;Yang, Hyeong-Cheol;Lee, In-Seop;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • 제41권5호
    • /
    • pp.242-247
    • /
    • 2011
  • Purpose: The purpose of this study was to characterize the osseointegration of the fibronectin-coated implant surface. Methods: Sand-blasted, large-grit, acid-etched (SLA) surface implants, with or without a thin calcium phosphate and fibronectin coating, were placed in edentulous mandibles of dogs 8 weeks after extraction. All dogs were sacrificed forhistological and histomorphometric evaluation after 4- and 8-week healing periods. Results: All types of implants were clinically stable without any mobility. Although the bone-to-implant contact and bone density of the SLA implants coated with calcium phosphate (CaP)/fibronectin were lower than the uncoated SLA implants, there were no significant differences between the uncoated SLA surface group and the SLA surface coated with CaP/fibronectin group. Conclusions: Within the limits of this study, SLA surfaces coated with CaP/fibronectin were shown to have comparable bone-to-implant contact and bone density to uncoated SLA surfaces.

Biologic stability of plasma ion-implanted miniscrews

  • Cho, Young-Chae;Cha, Jung-Yul;Hwang, Chung-Ju;Park, Young-Chel;Jung, Han-Sung;Yu, Hyung-Seog
    • 대한치과교정학회지
    • /
    • 제43권3호
    • /
    • pp.120-126
    • /
    • 2013
  • Objective: To gain basic information regarding the biologic stability of plasma ion-implanted miniscrews and their potential clinical applications. Methods: Sixteen plasma ion-implanted and 16 sandblasted and acid-etched (SLA) miniscrews were bilaterally inserted in the mandibles of 4 beagles (2 miniscrews of each type per quadrant). Then, 250 - 300 gm of force from Ni-Ti coil springs was applied for 2 different periods: 12 weeks on one side and 3 weeks contralaterally. Thereafter, the animals were sacrificed and mandibular specimens including the miniscrews were collected. The insertion torque and mobility were compared between the groups. The bone-implant contact and bone volume ratio were calculated within 800 mm of the miniscrews and compared between the loading periods. The number of osteoblasts was also quantified. The measurements were expressed as percentages and analyzed by independent t-tests (p < 0.05). Results: No significant differences in any of the analyzed parameters were noted between the groups. Conclusions: The preliminary findings indicate that plasma ion-implanted miniscrews have similar biologic characteristics to SLA miniscrews in terms of insertion torque, mobility, bone-implant contact rate, and bone volume rate.