• Title/Summary/Keyword: Body images

Search Result 1,267, Processing Time 0.023 seconds

$^{99m}Tc$-HMPAO-labelled Leucocyte Scintigraphy in the Diagnosis of Infection after Total Knee Replacement Arthroplasty (인공슬관절 전치환술 환자에서 $^{99m}Tc$-HMPAO-백혈구 스캔을 이용한 인공관절 감염의 진단)

  • Park, Dong-Rib;Kim, Jae-Seung;Ryu, Jin-Sook;Moon, Dae-Hyuk;Bin, Seong-Il;Cho, Woo-Shin;Lee, Hee-Kyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.4
    • /
    • pp.413-421
    • /
    • 1999
  • Purpose: This study was performed to evaluate the usefulness of $^{99m}Tc$-HMPAO-labelled leucocyte scintigraphy for diagnosing prosthetic infection after total knee replacement arthroplasty without the aid of following bone marrow scintigraphy Materials and Methods: The study subjects were 25 prostheses of 17 patients (one man and 16 women, mean age. 65 years) who had total knee replacement arthroplasty. After injection of $^{99m}Tc$-HMPAO-labelled leucocyte, the whole body planar and knee SPECT images were obtained in all patients. The subjects were classified into three groups according to clinical suspicion of prosthetic infection. Group A (n=11) with high suspicion of infection; Group B (n=6) with equivocal suspicion of infection, and Group C (n=8) with asymptomatic contralateral prostheses. Final diagnosis of infection was based on surgical, histological and bacteriological data and clinical follow-up. Results: Infection was confirmed in 13 prostheses (11 in Group A and 2 in Group B). All prostheses in Group A were true positive. There were two true positives, one false positive and three true negatives in Group B, and six true negatives and two false positives in Group C. Overall sensitivity, specificity, and accuracy for diagnosis of the infected knee prosthesis were 100%, 75% and 88%, respectively Conclusion: $^{99m}Tc$-HMPAO-labelled leucocyte scintigraphy is a sensitive method for the diagnosis of infected knee prosthesis. However, false positive uptakes even in asymptomatic prosthesis suggest that bone marrow scintigraphy may be needed to achieve improved specificity.

  • PDF

Comparison of the SNR in the MR images on dental implant material (치아 임플란트 재료에 따른 자기공명영상의 SNR 비교)

  • Kim, Dong-Hyun;Ko, Seong-Jin;Ye, Soo-Young
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.16 no.4
    • /
    • pp.149-155
    • /
    • 2015
  • Tooth implant is located in oral cavity and affects neck, skull base, and facail image. These magnetic inhomogeneities are usually frequency encoding direction which cause artifacts due to change of signal strength and geometric distortion. First, to evaluate signal to noise ratio (SNR) of magnetic resonance image caused by tooth implant this study uses meat phantom which is similar to human body and is consisted with fat, muscle, and water to measure signal to noise ratio. Second, signal to noise ratio by using custom-made fixed phantom is measured, and then signal to noise ratio size of different tooth implant types is compared and analyzed. The measured signal to noise ratio values of Brushite, HSA, Metal, and RBM for meat phantom were 2.76, 2.22, 1.88, and 1.57 on T1 SE, 1.88, 1.78, 1.65, and 1.79 on T2 FLAIR, 2.28, 2.25, 2.88, and 2.05 on T2 FSE, and 2.74, 1.94, 1.67, and 1.48 on T2 GRE. The measured signal to noise ratio values of Brushite, HSA, Metal, and RBM for fixed water phantom were 1.2, 1.06, 1.12, and 1.22 on DWI, 1.93, 1.87, 1.93, and 2.06 T1 SE, 1.83, 1.76, 1.82, and 1.92 on T2 FLAIR, 1.85, 1.79, 7.86, and 1.97 on T2 FSE, and 1.97, 1.93, 1.99, and 2.06 on T2 GRE. By considering through the results, patients and dentists need to consider some impacts from testing many aspects although their main purpose of having tooth implants is a dental restoration. Moreover, depending on the tooth implant characteristics of individual patients this study results can be used as baseline data when choosing test protocol.

Characteristics of the Electro-Optical Camera(EOC) (다목적실용위성탑재 전자광학카메라(EOC)의 성능 특성)

  • Seunghoon Lee;Hyung-Sik Shim;Hong-Yul Paik
    • Korean Journal of Remote Sensing
    • /
    • v.14 no.3
    • /
    • pp.213-222
    • /
    • 1998
  • Electro-Optical Camera(EOC) is the main payload of the KOrea Multi-Purpose SATellite(KOMPSAT) with the mission of cartography to build up a digital map of Korean territory including a Digital Terrain Elevation Map(DTEM). This instalment which comprises EOC Sensor Assembly and EOC Electronics Assembly produces the panchromatic images of 6.6 m GSD with a swath wider than 17 km by push-broom scanning and spacecraft body pointing in a visible range of wavelength, 510~730 nm. The high resolution panchromatic image is to be collected for 2 minutes during 98 minutes of orbit cycle covering about 800 km along ground track, over the mission lifetime of 3 years with the functions of programmable gain/offset and on-board image data storage. The image of 8 bit digitization, which is collected by a full reflective type F8.3 triplet without obscuration, is to be transmitted to Ground Station at a rate less than 25 Mbps. EOC was elaborated to have the performance which meets or surpasses its requirements of design phase. The spectral response, the modulation transfer function, and the uniformity of all the 2592 pixel of CCD of EOC are illustrated as they were measured for the convenience of end-user. The spectral response was measured with respect to each gain setup of EOC and this is expected to give the capability of generating more accurate panchromatic image to the users of EOC data. The modulation transfer function of EOC was measured as greater than 16 % at Nyquist frequency over the entire field of view, which exceeds its requirement of larger than 10 %. The uniformity that shows the relative response of each pixel of CCD was measured at every pixel of the Focal Plane Array of EOC and is illustrated for the data processing.

Polarization-sensitive Optical Coherence Tomography Imaging of Pleural Reaction Caused by Talc in an ex vivo Rabbit Model (생체 외 토끼 모델에서의 탈크에 의해 유발되는 흉막 반응의 편광 민감 광 결맞음 단층촬영 이미징)

  • Park, Jung-Eun;Xin, Zhou;Oak, Chulho;Kim, Sungwon;Lee, Haeyoung;Park, Eun-Kee;Jung, Minjung;Kwon, Daa Young;Tang, Shuo;Ahn, Yeh-Chan
    • Korean Journal of Optics and Photonics
    • /
    • v.31 no.1
    • /
    • pp.1-6
    • /
    • 2020
  • The chest wall, an organ directly affected by environmental particles through respiration, consists of ribs, a pleural layer and intercostal muscles. To diagnose early and treat disease in this body part, it is important to visualize the details of the chest wall, but the structure of the pleural layer cannot be seen by chest computed tomography or ultrasound. On the other hand, optical coherence tomography (OCT), with a high spatial resolution, is suited to observe pleural-layer response to talc, one of the fine materials. However, intensity-based OCT is weak in providing information to distinguish the detailed structure of the chest wall, and cannot distinguish the reaction of the pleural layer from the change in the muscle by the talc. Polarization-sensitive OCT (PS-OCT) takes advantage of the fact that specific tissues like muscle, which have optical birefringence, change the backscattered light's polarization state. Moreover, the birefringence of muscle associated with the arrangement of myofilaments indicates the muscle's condition, by measuring retardation change. The PS-OCT image is interpreted from three major perspectives for talc-exposure chest-wall imaging: a thickened pleural layer, a separation between pleural layer and muscle, and a phase-retardation measurement around lesions. In this paper, a rabbit chest wall after talc pleurodesis is investigated by PS-OCT. The PS-OCT images visualize the pleural layer and muscle, respectively, and this system shows different birefringence of normal and damaged lesions. Also, an analyisis based on phase-retardation slope supports results from the PS-OCT image and histology.

A Study on the "Holing-Bowl(받침그릇, 承盤) for the Jung-Byoung(정병, 淨甁)" or The Sacred Water-pot (정병 받침그릇(淨甁 承盤) 살핌 -고려불화(佛畵)-수월관음그림(水月觀音圖)으로 -)

  • Ghang, soon-hyoung
    • Korean Journal of Heritage: History & Science
    • /
    • v.34
    • /
    • pp.124-136
    • /
    • 2001
  • Among many different types of wares, we have amazing Sacred Water-pot(따르개, 注子) from Goryo-period(고리, 高麗, 918-1392). The stylistic peculiarity of Jung-Byoung(정병, 淨甁) is described in "Goryo-Dhogyoung, 고리도경, 高麗圖經", the classical design canon. It is said, "A sharpened mouth with narrow and prolonged neck is attached upon the broad mouth with thicker and even longer neck of the pot whose body intimates to the shape of melon." One could find this Jung-Byoung similar to the Indian drinking water jar, Kundika, which has been. even today, an everyday article in houses as well as in temples. In the early Buddhist cult, the object had been adopted as personal belonging of the Bodhisattvas(보살, 菩薩), especially of the Bodhisattva Avalokitesvara(관세음보살,觀世音菩薩). In short, the purifying character of water is met by the sacred ware to deliver the refreshing Sweet-Water(Holy-Water, 깨맑물, 단물, 단이슬물, 정수, 감로, 감로수, 성수, 淨水, 甘露, 甘露水, 聖水): For the holy purpose of fulfilling the thirst of people, of symbolozing the virtuous dharma. Thus, Ggamslkh-Byoung(깨맑병,淨水), the literal Korean name, denotes purifying and clarifying and clarifying water-pot to us. Among many other Asian countries, India, China, Korea, and Japan have a profound cult of the sacred water-pot(Ggamalkh-Byoung, Jung-Byoung, 깨맑병, 정병, 정수병, 감로병, 감로수병, 淨甁, 淨水甁, 甘露甁, 甘露水甁). Therefore, this charming holy object drew much attention not only from master artisans to shape and deliver them to people but also from painters and sculptors for their endowment of the sacred images dedicated to Buddha(부처,佛,佛陀). In China, the sacred water pot emerged in the period of Tang(당, 唐, 618~907)-Period and underwent much sophistication later on, I. e., from earthenware, ceramic-porcelain, bronze, and silver. However, the following represents a challenge to the well-known Goryo-Thangka(고리불화, 高麗佛畵) Painting of Bodhisattva Avalokitesvara to our speculation on the Sacred Water-pot(정병, 淨甁). The image suggests, when examined closely, that the Sacred Water-pot has been accompanied by, or placed in, a transparent glasswere(유리그릇) or crystalbowl(수정그릇)! We have no other physical proof of the existence of such a Holding-Bowl(받침그릇, 承盤), except for in this particular painting. This Holding-Bowl would have not been a mere elaboration on the practicality of controling the drips from the mouth of the pot. As in the chapter on Tang-ho(탕호, 湯壺), or thermal bowl, in the "Goryo-Dhogyoung" it advises readers that this style of bowl is to be filled with hot water, and thus function as a preserver of heat in the water inside the pot. As an offering to the Buddha, the Sacred Water-pot could have been used for serving him hot tea. Hence the sacred bottle is to contain the refreshing water, the water transcends to nectar, and the nectar is prepared as a nectar tea to offer the Buddha. For both the Holding-Bowl of Ggamalkh-Byoung(Jung-Byoung)and the Celestial-Robe(날개옷, 天衣) of the Bodhisattva Avalokitesvara, whose specified character is the Water-Moon(수월, 水月) in this particular Thangka(불화, 佛畵) painting, the transparency is essential. This is to refer to the purity and the lucid clarity of Bodhisattva Avalokitesvara and at a deeper level, to refer to the world of Buddhas-the Tushita(Paradise, Heaven, Eden, 극락, 불세계, 極樂, 佛世界). Howerver, without the discovery of an actual Holding-Bowl, accompanied by a Sacred Water-pot, such speculation will necessarily remain hypothetical. Nevertheless, there is an abundance of evidence of our ancient craftsmanship in jade and ctystal, dating back to the Bronze Age(1000~2B.C.) in Korea. By the time of the Three Kingdom-Period(삼국시대, 三國時代, 57B.C.~935A.D.), and especially the Silla(신라, 新羅, 57B.C.~935A.D.)-Empire, the jade and crystal ornamentation had become very intricate indeed. By the Goryo-Period(918~1392) and Chosun-Period(조선, 朝鮮,1392~1910),crystal-ware and jade art were popular in houses and Buddhist temples, whose master artsanship was heightened in the numerous Sarira-Cases(사리그릇, 舍利器), containing relics and placed inside Stupas(탑, 투, 搭)! Therefore, discovering a tiny part of the crystal or jade Holding-Bowl for the Sacred Water-pot and casting full light on this subject, would not be totally impossible. Lastly the present article shares the tiny hope for a sudden emergence of such a Holding-Bowl.

CHOBUN, Understanding the Double Burial Custom in Korea from a Jungian Perspective : Focusing on Putrefaction and Reduction to Bones (초분, 한국 이중장제의 분석심리학적 고찰 : 부패와 뼈로의 환원을 중심으로)

  • Jahyeon Cho
    • Sim-seong Yeon-gu
    • /
    • v.31 no.2
    • /
    • pp.113-150
    • /
    • 2016
  • Chobun refers to a temporary grave covered with straw thatch that contains a corpse until its flesh is gone. When all the flesh has rotted away, the straw grave is disassembled and only the bones are retrieved. Therefore, Chobun is an example of a secondary burial custom (German : Doppel Bestattung) that is composed of a first temporary funeral for processing the corpse's flesh, and a second permanent burial of the final remains (bones or ashes). The duration of the temporary burial is determined by the time needed for decomposing the flesh of the deceased. Building a Chobun progresses putrefaction and reduction to bone. In the literature of alchemy, putrefaction and new life occur simultaneously. The purpose of rotting is to make the flesh disappear, leaving only its essence. It is making the physical body enter a spiritual state, so that the dead can enter into a different world. One must endure the unstable rotting process until the smell of flesh has faded. The rotting process is the attitude of accepting the terrible, polluted aspect of the corpse, while maintaining a helpless, passive posture, in order to allow new possibilities. When we try to approach an archetypal aspect of the unconscious, it is often experienced in threatening, aggressive ways. In the individuation process, the unconscious offers us the blessing of a new spiritual awakening and renewed sense of life, only when we have the courage to see this terrifying and contaminated side of our psyche. This is exactly what putrefaction means. Bone and skeleton symbolize the indestructible, imperishable, and essential elements of life. Bone is the minimum unit and foundation for regeneration, where new life can grow. Reduction to bone is moving back to the origin of life, to the womb. Psychologically, it means discarding one's ego-centeredness and allowing the Self to lead the entire process of individuation. Going through the painful process of reduction to a skeleton for the purpose of further development is a declaration of the death of the ego, aiming at the liberation from perishable flesh and acquisition of the spiritual, regenerative, and immortal elements of life. Chobun also denotes the yearly decay and revival of life, especially of vegetal life. In Chobun, this symbolic meaning of the vegetal cycle of life is emphasized to represent the part of life that survives even after death. Vegetation related to Chobun deals with the continuity of life and psychologically with the Self. Images of vegetation are closely related to the existence of life beyond death, which is the existence of the Self, the source of energy that constantly renews and rejuvenates the consciousness.

Effect of Human Implantable Medical Devices on Dose and Image Quality during Chest Radiography using Automatic Exposure Control (자동노출제어를 적용한 흉부 방사선 검사 시 인체 이식형 의료기기가 선량과 화질에 미치는 영향)

  • Kang-Min Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.3
    • /
    • pp.257-265
    • /
    • 2024
  • In this study, we applied AEC(Auto Exposure Control), which is used in many chest examinations, to evaluate whether medical devices inserted into the body affect the dose and image quality of chest images. After attaching three HIMD(Human implantable medical devices) to the ion chamber, the Monte Carlo methodology-based program PCXMC(PC Program for X-ray Monte Carlo) 2.0 was applied to measure the effective dose by inputting the DAP(Dose Ares Product) value derived from the Pacemaker and CRT and Chemoport Additionally, to evaluate image quality, we set three regions of interest and one noise region on the chest and measured SNR and CNR. The final study results showed significant differences in DAP and Effective dose. There was a significant difference between Pacemaker and CRT when AEC was applied and not applied. (p<0.05) When applied, the dose increased by 37% for Pacemaekr and 52% for CRT. Chemoport showed a 10% increase in effective dose depending on whether AEC was applied, but there was no significant difference. (p>0.05) In the image quality evaluation, there was no significant difference in image quality between all HIMD insertions and AEC applied or not. (p>0.05) Therefore, when the HIMD was inserted into the chest during a chest x ray and overlapped with the ion chamber sensor, the effective dose increased, and there was no difference in image quality even at a low dose without AEC. Therefore, when performing a chest X-ray examination of a patient with a HIMD inserted, it is considered that performing the examination without applying AEC is a method that can be considered to reduce the patient's radiation exposure.

The Effect of Partially Used High Energy Photon on Intensity-modulated Radiation Therapy Plan for Head and Neck Cancer (두경부암 세기변조방사선치료 계획 시 부분적 고에너지 광자선 사용에 따른 치료계획 평가)

  • Chang, Nam Joon;Seok, Jin Yong;Won, Hui Su;Hong, Joo Wan;Choi, Ji Hun;Park, Jin Hong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.1
    • /
    • pp.1-8
    • /
    • 2013
  • Purpose: A selection of proper energy in treatment planning is very important because of having different dose distribution in body as photon energy. In generally, the low energy photon has been used in intensity-modulated radiation therapy (IMRT) for head and neck (H&N) cancer. The aim of this study was to evaluate the effect of partially used high energy photon at posterior oblique fields on IMRT plan for H&N cancer. Materials and Methods: The study was carried out on 10 patients (nasopharyngeal cancer 5, tonsilar cancer 5) treated with IMRT in Seoul National University Bundang Hospital. CT images were acquired 3 mm of thickness in the same condition and the treatment plan was performed by Eclipse (Ver.7.1, Varian, Palo Alto, USA). Two plans were generated under same planing objectives, dose volume constraints, and eight fields setting: (1) The low energy plan (LEP) created using 6 MV beam alone, (2) the partially used high energy plan (PHEP) created partially using 15 MV beam at two posterior oblique fields with deeper penetration depths, while 6 MV beam was used at the rest of fields. The plans for LEP and PHEP were compared in terms of coverage, conformity index (CI) and homogeneity index (HI) for planning target volume (PTV). For organs at risk (OARs), $D_{mean}$ and $D_{50%}$ were analyzed on both parotid glands and $D_{max}$, $D_{1%}$ for spinal cord were analyzed. Integral dose (ID) and total monitor unit (MU) were compared as addition parameters. For the comparing dose to normal tissue of posterior neck, the posterior-normal tissue volume (P-NTV) was set on the patients respectively. The $D_{mean}$, $V_{20Gy}$ and $V_{25Gy}$ for P-NTV were evaluated by using dose volume histogram (DVH). Results: The dose distributions were similar with regard to coverage, CI and HI for PTV between the LEP and PHEP. No evident difference was observed in the spinal cord. However, the $D_{mean}$, $D_{50%}$ for both parotid gland were slightly reduced by 0.6%, 0.7% in PHEP. The ID was reduced by 1.1% in PHEP, and total MU for PHEP was 1.8% lower than that for LEP. In the P-NTV, the $D_{mean}$, $V_{20Gy}$ and $V_{25Gy}$ of the PHEP were 1.6%, 1.8% and 2.9% lower than those of LEP. Conclusion: Dose to some OARs and a normal tissue, total monitor unit were reduced in IMRT plan with partially used high energy photon. Although these reduction are unclear how have a clinical benefit to patient, application of the partially used high energy photon could improve the overall plan quality of IMRT for head and neck cancer.

  • PDF

The Effect of Brand Extension of Private Label on Consumer Attitude - a focus on the moderating effect of the perceived fit difference between parent brands and an extended brand - (PL의 브랜드확장이 소비자태도에 미치는 영향에 관한 연구 : 모브랜드 적합도 인식 차이의 조절효과를 중심으로)

  • Kim, Jong-Keun;Kim, Hyang-Mi;Lee, Jong-Ho
    • Journal of Distribution Research
    • /
    • v.16 no.4
    • /
    • pp.1-27
    • /
    • 2011
  • Introduction: Sales of private labels(PU have been growing m recent years. Globally, PLs have already achieved 20% share, although between 25 and 50% share in most of the European markets(AC. Nielson, 2005). These products are aimed to have comparable quality and prices as national brand(NB) products and have been continuously eroding manufacturer's national brand market share. Stores have also started introducing premium PLs that are of higher-quality and more reasonably priced compared to NBs. Worldwide, many retailers already have a multiple-tier private label architecture. Consumers as a consequence are now able to have a more diverse brand choice in store than ever before. Since premium PLs are priced higher than regular PLs and even, in some cases, above NBs, stores can expect to generate higher profits. Brand extensions and private label have been extensively studied in the marketing field. However, less attention has been paid to the private label extension. Therefore, this research focuses on private label extension using the Multi-Attribute Attitude Model(Fishbein and Ajzen, 1975). Especially there are few studies that consider the hierarchical effect of the PL's two parent brands: store brand and the original PL. We assume that the attitude toward each of the two parent brands affects the attitude towards the extended PL. The influence from each parent brand toward extended PL will vary according to the perceived fit between each parent brand and the extended PL. This research focuses on how these two parent brands act as reference points to one another in the consumers' choice consideration. Specifically we seek to understand how store image and attitude towards original PL affect consumer perceptions of extended premium PL. How consumers perceive extended premium PLs could provide strategic suggestions for retailer managers with specific suggestions on whether it is more effective: to position extended premium PL similarly or dissimilarly to original PL especially on the quality dimension and congruency with store image. There is an extensive body of research on branding and brand extensions (e.g. Aaker and Keller, 1990) and more recently on PLs(e.g. Kumar and Steenkamp, 2007). However there are no studies to date that look at the upgrading and influence of original PLs and attitude towards store on the premium PL extension. This research wishes to make a contribution to this gap using the perceived fit difference between parent brands and extended premium PL as the context. In order to meet the above objectives, we investigate which factors heighten consumers' positive attitude toward premium PL extension. Research Model and Hypotheses: When considering the attitude towards the premium PL extension, we expect four factors to have an influence: attitude towards store; attitude towards original PL; perceived congruity between the store image and the premium PL; perceived similarity between the original PL and the premium PL. We expect that all these factors have an influence on consumer attitude towards premium PL extension. Figure 1 gives the research model and hypotheses. Method: Data were collected by an intercept survey conducted on consumers at discount stores. 403 survey responses were attained (total 59.8% female, across all age ranges). Respondents were asked to respond to a series of Questions measured on 7 point likert-type scales. The survey consisted of Questions that measured: the trust towards store and the original PL; the satisfaction towards store and the original PL; the attitudes towards store, the original PL, and the extended premium PL; the perceived similarity of the original PL and the extended premium PL; the perceived congruity between the store image and the extended premium PL. Product images with specific explanations of the features of premium PL, regular PL and NB we reused as the stimuli for the Question response. We developed scales to measure the research constructs. Cronbach's alphaw as measured each construct with the reliability for all constructs exceeding the .70 standard(Nunnally, 1978). Results: To test the hypotheses, path analysis was conducted using LISREL 8.30. The path analysis for verification of the model produced satisfactory results. The validity index shows acceptable results(${\chi}^2=427.00$(P=0.00), GFI= .90, AGFI= .87, NFI= .91, RMSEA= .062, RMR= .047). With the increasing retailer use of premium PLBs, the intention of this research was to examine how consumers use original PL and store image as reference points as to the attitude towards premium PL extension. Results(see table 1 & 2) show that the attitude of each parent brand (attitudes toward store and original pL) influences the attitude towards extended PL and their perceived fit moderates these influences. Attitude toward the extended PL was influenced by the relative level of perceived fit. Discussion of results and future direction: These results suggest that the future strategy for the PL extension needs to consider that positive parent brand attitude is more strongly associated with the attitude toward PL extensions. Specifically, to improve attitude towards PL extension, building and maintaining positive attitude towards original PL is necessary. Positioning premium PL congruently to store image is also important for positive attitude. In order to improve this research, the following alternatives should also be considered. To improve the research model's predictive power, more diverse products should be included in study. Other attributes of product should also be included such as design, brand name since we only considered trust and satisfaction as factors to build consumer attitudes.

  • PDF

Performance Evaluation of Siemens CTI ECAT EXACT 47 Scanner Using NEMA NU2-2001 (NEMA NU2-2001을 이용한 Siemens CTI ECAT EXACT 47 스캐너의 표준 성능 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.259-267
    • /
    • 2004
  • Purpose: NEMA NU2-2001 was proposed as a new standard for performance evaluation of whole body PET scanners. in this study, system performance of Siemens CTI ECAT EXACT 47 PET scanner including spatial resolution, sensitivity, scatter fraction, and count rate performance in 2D and 3D mode was evaluated using this new standard method. Methods: ECAT EXACT 47 is a BGO crystal based PET scanner and covers an axial field of view (FOV) of 16.2 cm. Retractable septa allow 2D and 3D data acquisition. All the PET data were acquired according to the NEMA NU2-2001 protocols (coincidence window: 12 ns, energy window: $250{\sim}650$ keV). For the spatial resolution measurement, F-18 point source was placed at the center of the axial FOV((a) x=0, and y=1, (b)x=0, and y=10, (c)x=70, and y=0cm) and a position one fourth of the axial FOV from the center ((a) x=0, and y=1, (b)x=0, and y=10, (c)x=10, and y=0cm). In this case, x and y are transaxial horizontal and vertical, and z is the scanner's axial direction. Images were reconstructed using FBP with ramp filter without any post processing. To measure the system sensitivity, NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves were scanned at the center of transaxial FOV and 10 cm offset from the center. Attenuation free values of sensitivity wire estimated by extrapolating data to the zero wall thickness. NEMA scatter phantom with length of 70 cm was filled with F-18 or C-11solution (2D: 2,900 MBq, 3D: 407 MBq), and coincidence count rates wire measured for 7 half-lives to obtain noise equivalent count rate (MECR) and scatter fraction. We confirmed that dead time loss of the last flame were below 1%. Scatter fraction was estimated by averaging the true to background (staffer+random) ratios of last 3 frames in which the fractions of random rate art negligibly small. Results: Axial and transverse resolutions at 1cm offset from the center were 0.62 and 0.66 cm (FBP in 2D and 3D), and 0.67 and 0.69 cm (FBP in 2D and 3D). Axial, transverse radial, and transverse tangential resolutions at 10cm offset from the center were 0.72 and 0.68 cm (FBP in 2D and 3D), 0.63 and 0.66 cm (FBP in 2D and 3D), and 0.72 and 0.66 cm (FBP in 2D and 3D). Sensitivity values were 708.6 (2D), 2931.3 (3D) counts/sec/MBq at the center and 728.7 (2D, 3398.2 (3D) counts/sec/MBq at 10 cm offset from the center. Scatter fractions were 0.19 (2D) and 0.49 (3D). Peak true count rate and NECR were 64.0 kcps at 40.1 kBq/mL and 49.6 kcps at 40.1 kBq/mL in 2D and 53.7 kcps at 4.76 kBq/mL and 26.4 kcps at 4.47 kBq/mL in 3D. Conclusion: Information about the performance of CTI ECAT EXACT 47 PET scanner reported in this study will be useful for the quantitative analysis of data and determination of optimal image acquisition protocols using this widely used scanner for clinical and research purposes.