• Title/Summary/Keyword: Body contouring

Search Result 32, Processing Time 0.028 seconds

Polyostotic Fibrous Dysplasia of Cranio-Maxillofacial Area (두개 악안면 부위에 발생한 다골성 섬유성이형성증)

  • Han Jin-Woo;Kwon Hyuk-Rok;Lee Jin-Ho;Park In-Woo
    • Imaging Science in Dentistry
    • /
    • v.30 no.2
    • /
    • pp.149-154
    • /
    • 2000
  • Fibrous dysplasia is believed to be a hamartomatous developmental lesion of unknown origin. This disease is divided into monostotic and polyostotic fibrous dysplasia. Polyostotic type can be divided into craniofacial type, Lichtenstein-Jaffe type, and McCune-Albright syndrome. In this case, a 31-year-old female presented spontaneous loss of right mandibular teeth before 5 years and has shown continuous expansion of right mandibular alveolus. Through the radiographic view, the coarse pattern of the mixed radiopaque-lucent lesion was seen on the right mandibular body, and there was diffuse pattern of the mixed radiopaque-lucent lesion with ill-defined margin in the left mandibular body. In the right calvarium, the lesion had cotton-wool appearance. Partial excision for contouring, multiple extraction, and alveoloplasty were accomplished under general anesthesia for supportive treatment. Finally we could conclude this case was polyostotic fibrous dysplasia of cranio-maxillofacial area based on the clinical, radiologic finding, and histopathologic examination.

  • PDF

Experiences of Abdominoplasty without Undermining (박리없는 복부성형술의 경험)

  • Sim, Hyung Bo;Yoon, Sang Yup
    • Archives of Plastic Surgery
    • /
    • v.33 no.3
    • /
    • pp.303-307
    • /
    • 2006
  • No one technique provides an optimal outcome for all body contouring patients. There are many surgical options for abdominoplasty. Among these, this abdominoplasty without undermining consists of liposuction around abdominal subcutaneous fatty tissue, excision of lower abdominal flap. The procedure allows aggressive thinning and sculpting of abdominal flap. This operation minimizes the dead space, which often leads to postoperative complications, and preserves neurovascular supply to the abdominal skin. From 1999 to 2004, 18 patients underwent the abdominoplasty without undermining, resulting in high satisfaction rates with no significant complications, such as, pulmonary embolism and deep vein thrombosis. Patients could return to normal activity within a week. This abdominoplasty without undermining is an effective and safe alternative with low complication rate and enhances aesthetic results compared to traditional abdominal surgery.

Observing Children's Body Movement in Daily Activities : An Example of OWAS Application (활동 내에서의 유아 몸 움직임에 대한 관찰 : OWAS 인간공학 측정법의 적용 사례)

  • Yun, Eunju
    • Korean Journal of Childcare and Education
    • /
    • v.8 no.2
    • /
    • pp.139-155
    • /
    • 2012
  • This study aimed to glean lessons for desirable early childhood physical education programs by contouring the current paradigms on body or physical activities in the area of early education for young children. It also aimed to analyze their postures while participating in daily activities. The research method for analysis of children's postures while doing daily activities was OWAS(Ovako Working Posture Analysing System) which has been extensively used in ergonomics. Components of data analysis have been redesigned on the basis of information gathered from OWAS with the help of ergonomic experts. The results showed different percentages of children's movements according to activities such as whole class meeting, small group activity and outdoor activity. Small group and outdoor activities can be considered the most desirable physical activities not only for cognitive and social development but also for physical development. And it is recommended to reconstruct the quality and nature of whole class meetings in order to coordinate the physical nature of young children.

Scientific review of the aesthetic uses of botulinum toxin type A

  • Park, Mee Young;Ahn, Ki Young
    • Archives of Craniofacial Surgery
    • /
    • v.22 no.1
    • /
    • pp.1-10
    • /
    • 2021
  • Botulinum toxin type A (BoNT-A), onabotulinumtoxinA (Botox) was approved by the United States Food and Drug Administration for temporary improvement of glabellar lines in patients 65 years and younger in 2002, and has also been used widely for aesthetic purposes such as hyperhidrosis, body shape contouring, and other noninvasive facial procedures. BoNT-A inhibits presynaptic exocytosis of acetylcholine (ACh)-containing vesicles into the neuromuscular junction at cholinergic nerve endings of the peripheral nervous system, thereby paralyzing skeletal muscles. ACh is the most broadly used neurotransmitter in the somatic nervous system, preganglionic and postganglionic fibers of parasympathetic nerves, and preganglionic fibers or postganglionic sudomotor nerves of sympathetic nerves. The scientific basis for using BoNT-A in various cosmetic procedures is that its function goes beyond the dual role of muscle paralysis and neuromodulation by inhibiting the secretion of ACh. Although the major target organs for aesthetic procedures are facial expression muscles, skeletal body muscles, salivary glands, and sweat glands, which are innervated by the somatic or autonomic nerves of the peripheral cholinergic nerve system, few studies have attempted to directly explain the anatomy of the areas targeted for injection by addressing the neural physiology and rationale for specific aesthetic applications of BoNT-A therapy. In this article, we classify the various cosmetic uses of BoNT-A according to the relevant component of the peripheral nervous system, and describe scientific theories regarding the anatomy and physiology of the cholinergic nervous system. We also review critical physiological factors and conditions influencing the efficacy of BoNT-A for the rational aesthetic use of BoNT-A. We hope that this comprehensive review helps promote management policies to support long-term, safe, successful practice. Furthermore, based on this, we look forward to developing and expanding new advanced indications for the aesthetic use of BoNT-A in the future.

Dosimetric Effects of Air Pocket during Magnetic Resonance-Guided Adaptive Radiation Therapy for Pancreatic Cancer

  • Jin, Hyeongmin;Kim, Dong-Yun;Park, Jong Min;Kang, Hyun-Cheol;Chie, Eui Kyu;An, Hyun Joon
    • Progress in Medical Physics
    • /
    • v.30 no.4
    • /
    • pp.104-111
    • /
    • 2019
  • Purpose: Online magnetic resonance-guided adaptive radiotherapy (MRgART), an emerging technique, is used to address the change in anatomical structures, such as treatment target region, during the treatment period. However, the electron density map used for dose calculation differs from that for daily treatment, owing to the variation in organ location and, notably, air pockets. In this study, we evaluate the dosimetric effect of electron density override on air pockets during online ART for pancreatic cancer cases. Methods: Five pancreatic cancer patients, who were treated with MRgART at the Seoul National University Hospital, were enrolled in the study. Intensity modulated radiation therapy plans were generated for each patient with 60Co beams on a ViewrayTM system, with a 45 Gy prescription dose for stereotactic body radiation therapy. During the treatment, the electron density map was modified based on the daily MR image. We recalculated the dose distribution on the plan, and the dosimetric parameters were obtained from the dose volume histograms of the planning target volume (PTV) and organs at risk. Results: The average dose difference in the PTV was 0.86Gy, and the observed difference at the maximum dose was up to 2.07 Gy. The variation in air pockets during treatment resulted in an under- or overdose in the PTV. Conclusions: We recommend the re-contouring of the air pockets to deliver an accurate radiation dose to the target in MRgART, even though it is a time-consuming method.

Feasibility of Improving the Accuracy of Dose Calculation Using Hybrid Computed Tomography Images: A Phantom Study

  • Jeon, Hosang;Kim, Dong Woon;Joo, Ji Hyeon;Ki, Yongkan;Kim, Wontaek;Park, Dahl;Nam, Jiho;Kim, Dong Hyeon
    • Progress in Medical Physics
    • /
    • v.32 no.1
    • /
    • pp.18-24
    • /
    • 2021
  • Purpose: Kilovoltage computed tomography (kV-CT) is essential for radiation treatment planning. However, kV-CT images are significantly distorted by artifacts when a metallic prosthesis is present in the patient's body. Thus, the accuracies of target delineation and treatment dose calculation are inevitably lowered. We evaluated the accuracy of the calculated doses using an image restoration method with hybrid CT, which was introduced in our previous study. Methods: A cylindrical phantom containing four metals, namely, silver, copper, tin, and tungsten, was scanned using kV-CT and megavoltage CT to produce hybrid CT images. We created six verification plans for three head and neck patients on kV-CT and hybrid CT images of the phantom and calculated their doses. The actual doses were measured with film patches during beam delivery using tomotherapy. We used the gamma evaluation method to compare dose distribution between kV-CT and hybrid CT with three gamma criteria, namely, 3%/3 mm, 2%/2 mm, and 1%/1 mm. Results: The gamma pass rates decreased as the gamma criteria were strengthened, and the pass rate of hybrid CT was higher than that of kV-CT in all cases. When the 1%/1 mm criterion was used, the difference in gamma pass rates between them was up to 13%p. Conclusions: According to our findings, we expect that the use of hybrid CT can be a suitable approach to avoid the effect of severe metal artifacts on the accuracy of dose calculation and contouring.

Gluteal Region Reshaping of Massive Weight Loss Patients-A Decision-Making Strategy

  • Mahgoub, Mohamed Ali;Zeina, Ahmed Mahmoud;El-Din, Ahmed Mohamed Bahaa;El-Sabbagh, Ahmed Hassan;Bassetto, Franco;Vindigni, Vincenzo
    • Archives of Plastic Surgery
    • /
    • v.49 no.3
    • /
    • pp.289-295
    • /
    • 2022
  • Background Massive weight loss (MWL) is a very common presentation that you may face as a plastic surgeon. Each patient has his own individual criteria, so, you should work according to a well-organized plan, especially when such cases have concerns about their gluteal area contour that were neglected before by many surgeons. A decision-making strategy was used to give a personalized treatment for targeting gluteal region reshaping of MWL patients. Methods This study considered all patients with MWL subjected to buttock reshaping. There was no randomization in treatment; there was a case-by-case assessment. We analyzed the features of the buttocks, the type of surgery performed, the outcomes, and the complications. Results Fifty two patients were included (41 females and 11 males), ages ranged between 21 and 66 years. Demographic data, preoperative body mass index (BMI), duration of surgery, type of surgery, and postoperative complications were collected. Statistically significant improvements were observed in gluteal ptosis and patient satisfaction grades. Conclusion Aesthetic improvement of the buttocks involves either augmentation or contouring that may be obtained by liposculpture, surgical lifting, or combination. Patients with MWL have high expectations and are often treated with multiple procedures. Thus, an easy strategic approach personalized on each patient to treat multiple adjacent areas in one operation is necessary. Adipose tissue distribution, gluteal skin status, and BMI were the main factors that can forcefully affect our plan to guarantee reduction of unpleasant results and complications and improve patient satisfaction.

The Effectiveness of 448-kHz Capacitive Resistive Monopolar Radiofrequency for Subcutaneous Fat Reduction in a Porcine Model

  • Kwon, Tae-Rin;Lee, Sung-Eun;Kim, Jong Hwan;Jeon, Yong Jae;Jang, You Na;Yoo, Kwang Ho;Kim, Beom Joon
    • Medical Lasers
    • /
    • v.8 no.2
    • /
    • pp.64-73
    • /
    • 2019
  • Background and Objectives The effectiveness of many physiotherapy modalities in reducing subcutaneous fat has been investigated in numerous previous studies. However, to the best of our knowledge, there have been no attempts to determine the effectiveness of physiotherapy modalities in body contouring. The present report determined the effect of 448-kHz capacitive resistive monopolar radiofrequency (CRMRF) in a porcine model. Materials and Methods This study investigated the effect of selective destruction of the subcutaneous fat layer in abdominal fat tissue using CRMRF. The effects of two types of CRMRF (capacitive electric transfer (CET) and resistive electric transfer (RET)) treatment were evaluated using regular digital photography in addition to thermal imaging evaluation, ultrasound measurement, hematological evaluation, and histologic analyses (H&E (hematoxylin and eosin), Oil red O, and immunohistochemistry staining). Results Preclinical evaluation was performed to obtain the data for comparison of the safety and efficacy of the subcutaneous fat reduction after applying CRMRF using CET and RET. After treatment, the thermal transmission was effective, and a 42-47℃ temperature change was observed in the fat layer while an approximately temperature of 42℃ was confirmed on the skin surface. Moreover, after the application of both types of CRMRF treatment, fibrotic septa were observed in the adipose tissue induced by heat at the treatment sites. TUNEL staining was also performed to confirm the process of apoptosis in the adipocytes. Conclusion These results suggest that both CET and RET for CRMRF treatment are safe and effective for subcutaneous fat reduction in a porcine model.

The Evaluation of Quantitative Accuracy According to Detection Distance in SPECT/CT Applied to Collimator Detector Response(CDR) Recovery (Collimator Detector Response(CDR) 회복이 적용된 SPECT/CT에서 검출거리에 따른 정량적 정확성 평가)

  • Kim, Ji-Hyeon;Son, Hyeon-Soo;Lee, Juyoung;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.2
    • /
    • pp.55-64
    • /
    • 2017
  • Purpose Recently, with the spread of SPECT/CT, various image correction methods can be applied quickly and accurately, which enabled us to expect quantitative accuracy as well as image quality improvement. Among them, the Collimator Detector Response(CDR) recovery is a correction method aiming at resolution recovery by compensating the blurring effect generated from the distance between the detector and the object. The purpose of this study is to find out quantitative change depending on the change in detection distance in SPECT/CT images with CDR recovery applied. Materials and Methods In order to find out the error of acquisition count depending on the change of detection distance, we set the detection distance according to the obit type as X, Y axis radius 30cm for circular, X, Y axis radius 21cm, 10cm for non-circular and non-circular auto(=auto body contouring, ABC_spacing limit 1cm) and applied reconstruction methods by dividing them into Astonish(3D-OSEM with CDR recovery) and OSEM(w/o CDR recovery) to find out the difference in activity recovery depending on the use of CDR recovery. At this time, attenuation correction, scatter correction, and decay correction were applied to all images. For the quantitative evaluation, calibration scan(cylindrical phantom, $^{99m}TcO_4$ 123.3 MBq, water 9293 ml) was obtained for the purpose of calculating the calibration factor(CF). For the phantom scan, a 50 cc syringe was filled with 31 ml of water and a phantom image was obtained by setting $^{99m}TcO_4$ 123.3 MBq. We set the VOI(volume of interest) in the entire volume of the syringe in the phantom image to measure total counts for each condition and obtained the error of the measured value against true value set by setting CF to check the quantitative accuracy according to the correction. Results The calculated CF was 154.28 (Bq/ml/cps/ml) and the measured values against true values in each conditional image were analyzed to be circular 87.5%, non-circular 90.1%, ABC 91.3% and circular 93.6%, non-circular 93.6%, ABC 93.9% in OSEM and Astonish, respectively. The closer the detection distance, the higher the accuracy of OSEM, and Astonish showed almost similar values regardless of distance. The error was the largest in the OSEM circular(-13.5%) and the smallest in the Astonish ABC(-6.1%). Conclusion SPECT/CT images showed that when the distance compensation is made through the application of CDR recovery, the detection distance shows almost the same quantitative accuracy as the proximity detection even under the distant condition, and accurate correction is possible without being affected by the change in detection distance.

  • PDF

Evaluation of Dose According to the Volume and Respiratory Range during SBRT in Lung Cancer (폐암의 정위적 체부 방사선치료 시 체적 설정과 호흡주기에 따른 선량평가)

  • Lee, Deuk-Hee;Park, Eun-Tae;Kim, Jung-Hoon;Kang, Se-Seik
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.391-397
    • /
    • 2016
  • Stereotactic body radiotherapy is effective technic in radiotherapy for low stage lung cancer. But lung cancer is affected by respiratory so accurately concentrate high dose to the target is very difficult. In this study, evaluated the target volume according to how to take the image. And evaluated the dose by photoluminescence glass dosimeter according to how to contour the volume and respiratory range. As a result, evaluated the 4D CT volume was 10.4 cm3 which was closest value of real size target. And in dose case is internal target volume dose was 10.82, 16.88, 21.90 Gy when prescribed dose was 10, 15, 20 Gy and it was the highest dose. Respiratory gated radiotherapy dose was more higher than internal target volume. But it made little difference by respiratory range. Therefore, when moving cancer treatment, acquiring image by 4D CT, contouring internal target volume and respiratory gated radiotherapy technic would be the best way.