• 제목/요약/키워드: Blowing Rate

검색결과 98건 처리시간 0.03초

벼 상온통풍건조시설의 송풍특성 (Airflow Characteristics of Natural Air Drying for Rough Rice)

  • 이효재;김훈;한재웅
    • 한국지역사회생활과학회지
    • /
    • 제24권3호
    • /
    • pp.391-397
    • /
    • 2013
  • This study was conducted to define the characteristics of the fan according to the bed depth of rough rice for the silo used in South Korea. In this study, the characteristics like air flow resistance and air flow rate of the fan were investigated for an independent blowing system with 1 fan and the serial blowing system with 2 fans. In the experiment, the depth of rough rice was determined by 0, 1, 2, 3.2 and 4.5 m for an independent blowing system and the depth of rough rice was 4.5 m for the serial blowing system. The air flow resistances of the blowing fan and the suction fan in an independent blowing system were 55 mmAq and 88 mmAq respectively. In addition, the air flow resistance of the serial blowing system was 61% lower than the blowing fan and 28% lower than the suction fan of the independent blowing system. The air flow rates of the blowing fan and the suction fan in the serial blowing system were 516 $m^3/min$, 570 $m^3/min$, respectively. The former was 22% higher than the blowing fan while the latter was 29% higher than the suction fan in the independence blowing system. In other words, the serial blowing system was superior to the independent blowing system in blowing characteristics because the air flow rate was lower and air flow resistance was higher than the independent blowing system. However, the fan power consumption of the serial blowing system was more than 100% comparing with the independent blowing system.

Navier-Stokes 방법을 이용한 Blowing이 무딘물체 주위의 표면 열전달에 미치는 효과 연구 (A Numerical Study of Blowing Effect on Wall Heat Trasfer Rate over Blunt-bodies Using Naver-Stokes Method)

  • 권창오;송동주
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 1997년도 추계 학술대회논문집
    • /
    • pp.92-98
    • /
    • 1997
  • A finite-difference method based on characteristic upwind flux difference splitting has been studied on the blowing effect on the wall heat transfer over blunt-bodies. As the blowing rates increased, the wall heat transfer rate decreased and the temperature gradient also decreased compared with no blowing case. The heat trasfer rate at Mach No. 20 was almost twice higher than that of Mach No. 15 at 50km altitude. The surface blowing can be an effective mechanism to reduce the surface heat transfer rate at hypersonic flight condition.

  • PDF

온풍난방기 성능 개선 연구 (I) - 송풍방식에 따른 송풍성능 비교 - (Improvement of Space Heater (I) - Comparison of Blowing Performance for Blowing Type -)

  • 권순홍;정성원;이승기
    • 한국산업융합학회 논문집
    • /
    • 제3권3호
    • /
    • pp.245-250
    • /
    • 2000
  • This study was carried out to investigate blowing performance for blowing type in space heater. This paper present that power requirement, static pressure, total pressure and static pressure efficiency were increased in proportion to air flow rate. And in the Korean space heater, side ward blowing type was effected than downward blowing type.

  • PDF

자세교정훈련이 거북목증후군의 폐기능에 미치는 영향 (Effects of Posture Correction Training on Pulmonary Function with Turtle Neck Syndrome)

  • 장철
    • 대한통합의학회지
    • /
    • 제9권1호
    • /
    • pp.183-192
    • /
    • 2021
  • Purpose : The purpose of this study was to investigate the impact of postural correction training on pulmonary function on 28 college students suspected of turtle neck syndrome, and the following conclusions were obtained. Methods : Turtle neck syndrome suspicion 28 person were randomly divided into a posture training group (n = 14) and group that does not perform posture training (n = 14). Respiratory function was measured by SPIROVIT SP-1 and respiratory gas analyzer. The posture training group performed balloon blowing and stair climbing after 20 minutes of posture training, and the group without posture training carried out balloon blowing training and stair climbing. Five times a week and for two weeks. Results : 1. The comparison of the FVC before and after experiments caused by balloon blowing showed a higher level of effortful pulmonary function in the control group than in the experimental group. 2. Comparison of PEFs before and after the experiment by balloon blowing showed that the experimental group's peak flow rate was higher than that of the control group. 3. Comparison of the FIVC before and after experiments with balloon blowing showed that the comparison of the FIVC showed a higher level of effortless intake pulmonary function in the control group than in the experimental group. 4. The comparison of the maximum ventilation volume(VE) before and after the experimental gas measurement showed that the maximum ventilation rate of the experimental group was higher than that of the control group. 5. The comparison of pre-test and post-test heart rate(HR) by breath gas measurement showed that the heart rate of the control group was higher than that of the experimental group. Conclusion : the results of this study showed that postural correction training, balloon blowing training, and stair climbing could have a positive impact on improving pulmonary function. However, the two-week experiment conducted five times a week showed an increase in pulmonary function, but it was difficult to see the effect due to the short study period. Therefore, it is hoped that later studies will be conducted more systematically on the effects of breathing exercises on improving pulmonary function after post-postural correction training for patients with pulmonary function problems.

나선형 홈에 의한 하이브리드 로켓 고체연료의 연소율 증가 특성 (The Increase in Regression Rate due to Helical Grain in Solid Fuel of Hybrid Rocket)

  • 황영춘;이창진
    • 한국항공우주학회지
    • /
    • 제34권12호
    • /
    • pp.59-66
    • /
    • 2006
  • 하이브리드 로켓 연료의 연소율 향상을 위한 나선형 홈이 유동 특성에 미치는 영향을 규명하기 위하여 난류 증가와 선회 유동 발생에 대한 수치계산을 수행하였다. 나선형 튜브의 열전달 관계식을 이용하여 여러 형상의 나선형 홈이 있는 연료의 열전달 향상을 예측하였으며 연소율 측정값과 비교하여 상호 연관성을 확인하였다. 실험 결과와 열전달 향상 예측 값은 동일한 경향을 나타내더라도 수치는 큰 차이를 나타냈는데 이것은 연료가 연소하기 위하여 기화할 때 발생하는 분출속도가 존재하기 때문이다. 분출효과를 고려하여 RANS 계산을 수행한 결과, 난류에너지는 상당히 증가한 반면 선회 수는 조금 증가하는 결과를 보여 주었다. 그럼에도 불구하고 나선형 홈에 의한 난류 증가 또는 선회유동 생성은 연소율을 증가시키는 중요한 메커니즘임이 밝혀졌다. 그러나 분출로 인하여 난류에너지가 증가되어도 열전달 향상에 기여하지 못하는 것으로 확인되었는데 이것은 분출 속도가 표면의 경계층을 밀어내어 대류 열전달이 증가되는 것을 차단하기 때문인 것으로 밝혀졌다.

축류형 흡배송 송풍기의 성능에 관한 실험적연구 (A Experimental Study on the Performance of an Axial-Type Suction-Blowing Fan)

  • 최형준;박영하;안국영;조수용
    • 한국유체기계학회 논문집
    • /
    • 제14권4호
    • /
    • pp.19-24
    • /
    • 2011
  • An experimental study was conducted to examine the effectiveness of a suction-blowing fan that could not only remove polluted air by suction but also create the air-curtain by blowing. In order to create the air-curtain, rotors were installed on the surface of the shroud. These blows fresh air into the polluted region. The fresh air is spouted backward 45o on the basis of the axial direction using a double-ducted bellmouth. In the same suction operating condition, the suction region was extended by increasing the blowing velocity. However, the increasing rate of suction region was reduced when the blowing velocity was increased steadily. Thus, an efficient blowing velocity should be determined depending on the suction operating condition. In addition, the blowing requires additional input power. In a fixed suction operating condition, the input power was linearly increased in proportion to the blowing flowrate. When the suction-blowing fan was operated in the same input power as the suction fan, the suction region was increased more than 30% based on the 0.6m/sec velocity.

터빈 블레이드 선단에서의 샤워헤드 막냉강 - 국소분사율 측정 및 유동의 가시화 - (Shower-Head Film Cooling on the Leading Edge of a Turbine Blade: Measurements of Local Blowing Ratio and Flow Visualizations)

  • 정철희;이상우
    • 대한기계학회논문집B
    • /
    • 제23권3호
    • /
    • pp.419-430
    • /
    • 1999
  • Measurements of local blowing ratio and ammonia-diazo flow visualizations have been conducted for a shower-head film cooling on a first-stage turbine stator. In this study, six rows of normal holes are drilled symmetrically on the semicircular leading edge of a simulated blunt body. The measurements show that for an average blowing ratio based on freestream velocity, M, of 0.5, local average mass flow rate through the first two rows of the holes is less than those through the second and third two rows of the holes, and the fraction of mass flow rate through the first two rows to total mass flow rate has a tendency to increase with the increment of M. The flow visualizations reveal that the injection through the first two row results in inferior film coverage even In the case of M = 0.5, meanwhile the row of holes situated at farther downstream location provides higher film-cooling performances for all tested M. This is because film-cooling effectiveness depends on local mainflow velocity at the hole location as well as the mass flow rate through each row.

Ethylene Vinyl Acetate Copolymer 발포체의 발포특성 및 물리적 특성 (Foaming Characteristics and Physical Properties of Ethylene Vinyl Acetate Copolymer Foams)

  • 김진태;손우정;안병현;김원호
    • Elastomers and Composites
    • /
    • 제36권1호
    • /
    • pp.52-60
    • /
    • 2001
  • 발포체의 물성은 발포체의 밀도, 사용된 폴리머의 기계적 물성과 열린 셀(open cell) 함량, 셀 크기, 셀 크기 분포, 셀 형태, 격벽의 두께 등을 포함하는 셀 구조에 의존하며 이러한 발포체의 밀도는 사용된 폴리머의 종류와 가교제의 농도, 발포제의 농도 그리고 가공 기술 및가공 조건 같은 다양한 원료물질과 가교조건에 영향을 받는다. Ethylene vinyl acetate coplymer (EVA) 발포체는 가교 발포체로서 가교속도와 발포제의 분해속도에 의해 발포특성에 영향을 받으며 이에 따라 발포체 물성에도 영향을 미친다. 본 연구에서는 가공 온도인 $155^{\circ}C$에서의 시간에 따른 발포제의 분해 속도 차이와 이에 따른 발포특성과 발포체의 물성에 대한 영향을 평가하였다. 발포제 분해 속도가 보다 느린 경우, 발포제 분해속도가 빠른 경우와 비교하여 낮은 밀도를 보여주었으며, 우수한 충격흡수성을 나타내었고 발포체의 셀 크기는 보다 균일하였다.

  • PDF

Experimental Study of Film Cooling Behaviors at a Cylindrical Leading Edge

  • Kim S. M.;Kim Youn-J.
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2002년도 추계학술대회 논문집
    • /
    • pp.81-84
    • /
    • 2002
  • Dispersion of coolant jets in a film cooling flow field is the result of a highly complex interaction between the film cooling jets and the mainstream. In order to investigate the effect of blowing ratios on the film cooling of turbine blade, cylindrical body model was used. Mainstream Reynolds number based on the cylinder diameter was $7.1\;\times\;10^4$. The free-stream turbulence intensity kept at $5.0\%$ by using turbulence grid. The effect of coolant flow rates was studied for blowing ratios of 0.9, 1.3 and 1.6, respectively. The temperature distribution of the cylindrical model surface is visualized by infrared thermography (IRT). Results show that the film-cooling performance may be significantly improved by controlling the blowing ratio. As blowing ratio increases, the adiabatic film cooling effectiveness is more broadly distributed and the area protected by coolant increases. The mass flow rate of the coolant through the first-row holes is less than that through the second-row holes due to the pressure variation around the cylinder surface.

  • PDF

Effects of Blowing and Nucleating Agents on the Foaming Properties of Nylon 6

  • Jung-soo Kim;Sung Yeol Kim
    • Elastomers and Composites
    • /
    • 제58권2호
    • /
    • pp.65-69
    • /
    • 2023
  • To reduce the weight of the engineering plastic Nylon 6 resin, two high-temperature foaming agents, p-toluenesulfonyl semicarbazide (PTSS) and 5-phenyltetrazole (5-PT) (0-10 phr), were added and foamed without other additives. We investigated the effects of the foaming agent type and content on the foam density (g/cm3) and percent weight reduction rate of the Nylon 6 foam, and 5-PT exhibited better foaming performance than PTSS. In the case of 5-PT, the weight reduction rate was above 36% when the blowing agent content was 1.5 phr or higher, indicating that 5-PT is an effective blowing agent for reducing the Nylon 6 foam weight. Additionally, we studied the effect of the nucleating agent Talc content (0-0.4 phr) on Nylon 6 foaming, and the nucleating agent Talc considerably reduced foaming.