• 제목/요약/키워드: Blood flow rates

검색결과 124건 처리시간 0.026초

미소안면침이 안면 피부 온도와 혈류량에 미치는 영향 (Changes of Facial Temperature and Blood Flow Rates by Treatment of Miso Facial Rejuvenation Acupuncture)

  • 김태연;박종필;김용민
    • 동의생리병리학회지
    • /
    • 제27권4호
    • /
    • pp.481-486
    • /
    • 2013
  • To investigate the effects of facial temperature and blood flow rates generated by Miso Facial Rejuvenation Acupuncture treatment. Ten women in their twenties to fifties with no skin diseases were recruited. Miso Facial Rejuvenation Acupuncture(MFRA) was performed on the both sides of their face. We measured their facial temperature using Digital Infrared Thermal Imaging(DITI) and blood flow rates using Laser Doppler Perfusion Imaging(LDPI) at pre-treatment, immediately, twenty and sixty minutes after treatment. We analyzed data using student's t-test(p<0.05). After MFRA treatment, facial temperature on the measurement area increased immediately from $30.5{\pm}1.0^{\circ}C$ to $31.5{\pm}1.0^{\circ}C$, a statistically significant increase. Sixty minutes after treatment, facial temperature on the measurement area decreased a little bit($30.2{\pm}0.6^{\circ}C$), but there was no statistical significance. After MFRA treatment, facial blood flow rates on the measurement area increased immediately from $165.1{\pm}52.3$ PU to $342.7{\pm}51.3$ PU, a statistically significant increase. Sixty minutes after treatment, facial blood flow rates measurement area were recovered almost at the same level as before treatment. MFRA treatment could increase facial temperature and blood flow rates.

혈액투석 시 투석액 속도가 투석적절도와 피로에 미치는 효과 (The Effect of Dialysate Flow Rate on Dialysis Adequacy and Fatigue in Hemodialysis Patients)

  • 차선미;민혜숙
    • 대한간호학회지
    • /
    • 제46권5호
    • /
    • pp.642-652
    • /
    • 2016
  • Purpose: In this single repeated measures study, an examination was done on the effects of dialysate flow rate on dialysis adequacy and fatigue in patients receiving hemodialysis. Methods: This study was a prospective single center study in which repeated measures analysis of variance were used to compare Kt/V urea (Kt/V) and urea reduction ratio (URR) as dialysis adequacy measures and level of fatigue at different dialysate flow rates: twice as fast as the participant's own blood flow, 500 mL/min, and 700 mL/min. Thirty-seven hemodialysis patients received all three dialysate flow rates using counterbalancing. Results: The Kt/V ($M{\pm}SD$) was $1.40{\pm}0.25$ at twice the blood flow rate, $1.41{\pm}0.23$ at 500 mL/min, and $1.46{\pm}0.24$ at 700 mL/min. The URR ($M{\pm}SD$) was $68.20{\pm}5.90$ at twice the blood flow rate, $68.67{\pm}5.22$ at 500 mL/min, and $70.11{\pm}5.13$ at 700 mL/min. When dialysate flow rate was increased from twice the blood flow rate to 700 mL/min and from 500 mL/min to 700 mL/ min, Kt/V and URR showed relative gains. There was no difference in fatigue according to dialysate flow rate. Conclusion: Increasing the dialy-sate flow rate to 700 mL/min is associated with a significant increase in dialysis adequacy. Hemodialysis with a dialysate flow rate of 700 mL/min should be considered in selected patients not achieving adequacy despite extended treatment times and optimized blood flow rate.

20대 남성에서 최대운동이 뇌로가는 혈관인 총경동맥 혈류 속도에 미치는 영향 (Maximum exercise in 20 men Common carotid artery blood flow velocity impact)

  • 김지원
    • 한국방사선학회논문지
    • /
    • 제3권4호
    • /
    • pp.5-12
    • /
    • 2009
  • 총경동맥은 심장으로부터 혈액을 직접 대뇌로 전달하는 동맥 혈류 순환이 중요하며, 특히 동맥 혈관내의 혈액의 흐름을 방해하는 여러 변인들이 있다. 그 변인 중에서도 평균혈류속도, 맥박지수, 및 혈류 저항 변인 등이 있는데, 이중 맥박지수나 혈류저항지수는 최대 수축기와 이완기시 혈류속도와 관련이 되어있기 때문에 혈압과도 중요한 변인들이 된다, 이와 같은 뇌혈류 속도 변인들의 변화에 대해서 관찰하는 데는 비침습적인 초음파를 이용한 도플러 뇌혈류 측정법을 이용한다. 최대운동은 20대 남성에서 뇌로가는 혈류인 총경동맥의 혈류속도를 증가 시킬 수 있는 것으로 나타났다.

  • PDF

Comparison of Shear-Thinning Blood Flow Characteristics between Longitudinal and Transverse Vibration

  • Choi, Sung-Ho;Shin, Se-Hyun;Lee, Kyung-Tae
    • Journal of Mechanical Science and Technology
    • /
    • 제18권12호
    • /
    • pp.2258-2264
    • /
    • 2004
  • This article described the numerical investigation of shear-thinning blood flow characteristics when subjected to longitudinal and transverse vibrations and delineated the underlying mechanisms of the flow rate enhancements, respectively. In order to fully consider the mechanical vibrations of the capillary, a moving wall boundary condition was adopted. The present numerical results showed that the longitudinal vibration caused a significant increase of wall shear rates, which resulted in a decrease of viscosity and the subsequent increase of flow rates. However, the shear rate for the transverse vibration was slightly increased and the calculated flow rate was underestimated comparing with the previous experimental results.

Micro PIV 를 기반한 혈액 점도 측정 기법 (Microfluidic Method for Measurement of Blood Viscosity based on Micro PIV)

  • 홍현지;정미림;염은섭
    • 한국가시화정보학회지
    • /
    • 제15권3호
    • /
    • pp.14-19
    • /
    • 2017
  • Increase of blood viscosity significantly changes the flow resistance and wall shear stress which are related with cardiovascular diseases. For measurement of blood viscosity, microfluidic method has proposed by monitoring pressure between sample and reference flows in the downstream of a microchannel with two inlets. However, it is difficult to apply this method to unknown flow conditions. To measure blood viscosity under unknown flow conditions, a microfluidic method based on micro particle image velocimetry(PIV) is proposed in this study. Flow rate in the microchannel was estimated by assuming velocity profiles represent mean value along channel depth. To demonstrate the measurement accuracy of flow rate, the flow rates measured at the upstream and downstream of a T-shaped microchannel were compared with injection flow rate. The present results indicate that blood viscosity could be reasonably estimated according to shear rate by measuring the interfacial width and flow rate of blood flow. This method would be useful for understanding the effects of hemorheological features on the cardiovascular diseases.

주자독서환의 뇌기능 활성 및 신경세포 보호효과 (The Effects of Jujadokseo-hwan on the Activation of Brain and Neuroprotactive Effects)

  • 이유경;채중원
    • 대한한방소아과학회지
    • /
    • 제23권3호
    • /
    • pp.241-262
    • /
    • 2009
  • Objectives This study is designed to investigate the effects of Jujadokseo-hwan on the brain ability and inducing oxidative stresses. Methods We measured the changes of regional cerebral blood flow and mean arterial blood pressure. Then we analyzed histological examination, immunohistochemistric response and anti-oxidant activity of Jujadokseo-hwan. Results 1. Treatment of Jujadokseo-hwan significantly increased regional cerebral blood flow but decreased mean arterial blood pressure. 2. Treatment of Jujadokseo-hwan-induced increase of regional cerebral blood flow was significantly inhibited by pretreatment with indomethacin (1 mg/kg, i.p.), an inhibitor of cyclooxygenase. 3. In histological examination through TTC stain, group I was no change, but group II showed that discolored in the most cortical part. Group III showed that decreased discolor in the cortical part. 4. In immunohistochemistric response of BDNF, group II showed that lower response effect. Group III showed that increase response effect. 5. Treatment of Jujadokseo-hwan increased proliferation rates of Glial cell effectively 6. Treatment of Jujadokseo-hwan accelerated proliferation rates of C6 cells in vitro. In addition, protective effects on cell death induced by paraquat, rotenone and hydrogen peroxide. In addition, activity of SOD were increased by treatment with Jujadokseo-hwan. Conclusions In conclusion, Jujadokseo-hwan can improve of the brain ability, learning ability, memory ability and induce ischemic brain injuries.

  • PDF

혈액투석을 위한 동정맥류 조성술후 혈류량과 동정맥루 개존에 관한 임상적 고찰 (Clinical Analysis on Relation Between Blood Flow and Patency af Arteriovenous Fistula for Hemodialysis)

  • 김창회
    • Journal of Chest Surgery
    • /
    • 제24권12호
    • /
    • pp.1167-1172
    • /
    • 1991
  • Since March 1988 we have performed 133 arteriovenous fistulae for hemodialysis in 121 patients with chronic renal failure. Of the 133 cases of arteriovenous fistulae, follow-up evaluation was possible for 80 cases which performed in 69 patients. The relation between blood flow and patency rate and duration of arteriovenous fistula was examined. The overall 6 - 12 - 18 -, and 24 - month patency rates of arteriovenous fistulae were 82%, 64%a, 62%, and 57%, respectively. The maximum blood flow was 150 ~ 350ml /min[mean 217.1$\pm$44.27]. The patency duration was evaluated in patients divided into three groups owing to maximum blood flow through the fistulae. The range of maximum blood flow was 150 ~ 200ml /min for group A, 200 ~ 250ml /min for group B, and above 250ml /min for group C. The mean duration of the patency was 10.7$\pm$7.60 months in group A, 14.9$\pm$9.82 months in group B, and 21.6$\pm$11.16 months in group C[p<0 05]. With increased maximum blood flow, the duration of the patency was longer in group A than group B and C [r=0.39, p<0. 05]. The maintenance blood flow was 100 ~ 250ml /min[mean 179.2$\pm$37.26 ml/min]. When the maintenance blood flow was above 200ml /min, long-term patency rate was higher than the group below 200ml /min[r=0.48, p<0.01]. In the same range of blood flow, patency duration of the patients with using their own blood vessels were longer than the patients with using vascular graft for A-V fistula. We concluded that the patency of the arteriovenous fistulae was closely correlated with the blood flow through the fistulae.

  • PDF

시판 스포츠 컴프레션 웨어의 의복압이 혈류 및 주관적 감성에 미치는 영향 (Influence of Clothing Pressure on Blood Flow and Subjective Sensibility of Commercial Sports Compression Wear)

  • 김남임;이효정
    • 한국의류산업학회지
    • /
    • 제21권4호
    • /
    • pp.459-467
    • /
    • 2019
  • Compression wear provides clothing pressure and affects how blood flows. Facilitating a blood flow is one of the most important functions of compression wear. The wearer's sensibility should be considered when designing compression wear. This study instructed participants to put on 5 types of sport compression wear with different pressure levels (CP-1 to CP-5), measured clothing pressure, blood flow level, blood flow rate, and surface temperature, and examined the pressure level that influenced blood flow through a subjective sensibility assessment. An experiment measured the clothing pressure of compression wear available in the market and found that the pressure ranged 0.6-1.1 kPa for the ankle, 0.7-2.3 kPa for the calf, and 0.9-1.9 kPa for the thigh. Meanwhile, blood flow levels and rates significantly increased when participants wore CP-1, which had the highest clothing pressure level, and CP-2 and CP-4 with middle-level pressure. After exercise, CP-2's surface temperature was the highest and revealed that wearing CP-2 facilitated blood flow. CP-2 was evaluated as most positive in the sensibility assessment and showed a clothing pressure of 0.67-1.82 kPa; its pressure for the calf did not surpass 2.0 kPa. Considering positive physical effect of compression wear on blood flow and subjective psychological effect on participants, CP-2 (0.67-1.82 kPa) would have the most suitable clothing pressure level among other types of the wear in this study.

시메티딘이 간혈류량에 미치는 영향 - Rat에 있어서 Indocyanine Green의 체내 동태를 중심으로 - (Effect of Cimetidine on the Hepatic Blood flow -On the Basis of Pharmacokinetics of Indocvanine Green in Rats-)

  • 이용복;고익배
    • 한국임상약학회지
    • /
    • 제3권2호
    • /
    • pp.163-168
    • /
    • 1993
  • The influence of cimetidine pretreatment(100mg/kg, single i.p.) on the hepatic blood flow was investigated using pharmacokinetic parameters of indocyanine green(ICG) in the rat on the basis of hepacc perfusion-limited model. ICG(1mg/kg) was respectively administered via femoral and portal vein to the control and to the cimetidine-pretreated rats. The rate constant K12, K20 and the systemic clearance(CLt) of ICG were significantly(p<0.05) decreased ill the cimetidine-pretrea-to(B rats, but no significant diffirences were observed in hematocrit and liver weight. The biliary excretion rates of ICG were also decreased regardless of the route of administration in the cimetidine-pretreated rats. And also the hepatic blood flow in rats was decreased about $16\%$ by cimetidine. It may be concluded that the decreased hepatic blood flow with cimetidine mainly contributed to the decreased hepatic uptake and the decreased systemic clearance of ICG.

  • PDF