• 제목/요약/키워드: Blockage Factor

검색결과 44건 처리시간 0.024초

단관 환형배플 시스템의 전열성능에 대한 수치해석 (A Numerical Study on the Heat Transfer Performance of Single-Tube Annular Baffle System)

  • 홍정아;전용두;이금배
    • 설비공학논문집
    • /
    • 제24권8호
    • /
    • pp.621-626
    • /
    • 2012
  • A new baffle configuration, an annular baffles, are considered in the present study as an alternative to reduce the excessive pressure drop associated with the conventional segmental ones in typical operating conditions. The heat transfer and pressure drops are numerically simulated for a single tube shell-and-tube model and compared against the conventional-baffle cases. Baffle blockage ratio and number of baffles are considered as the major variables for the present study specifying a fixed baffle spacing. It is found that the heat transfer increases 1.4~2.2 times without significant pressure loss compared to the bare tube cases and the goodness factor increases 1.35 times compared to the conventional-baffle model.

원자로 부수로내 혼합날개를 지나는 삼차원 열유동 해석 (Numerical Analyses of Three-Dimensinal Thermo-Fluid Flow through Mixing Vane in A Subchannel of Nuclear Reactor)

  • 최상철;김광용
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2002년도 춘계 학술대회논문집
    • /
    • pp.79-87
    • /
    • 2002
  • The present work analyzed the effect of mixing vane shape on the flow structure and heat transfer downstream of mixing vane in a subchannel of fuel assembly, by obtaining velocity and pressure fields, turbulent intensity, flow-mixing factors, heat transfer coefficient and friction factor using three-dimensional RANS analysis. NJl5, NJ25, NJ35, NJ45, which were designed by the authors, were tested to evaluate the performances in enhancing the heat transfer. Standard $\kappa-\epsilon$ model is used as a turbulence closure model, and, periodic and symmetry conditions are set as boundary conditions. The flow blockage ratio is kept constant, but the twist angle of mixing vane is changed. The results with three turbulence models( $\kappa-\epsilon$, $\kappa-\omega$, RSM) were compared with experimental data.

  • PDF

원심다익송풍기의 미끄럼 계수에 대한 연구 (Study on The Slip Factor Model for Multi-Blades Centrifugal Fan)

  • 구오엔민;김광용;서성진
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2002년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.111-115
    • /
    • 2002
  • The objective of this work is to develop improved slip factor model and correction method to predict flow through impeller in forward-curved centrifugal fan by investigating the validity of various slip factor models. Both steady and unsteady three-dimensional CFD analyses were performed with a commercial code tn validate the slip factor model and the correction method. The results show that the improved slip factor model presented in this paper could provide more accurate predictions for forward-curved centrifugal impeller than the other slip factor models since the presented model takes into account the effect of blade curvature. The comparison with CFD results also shows that the improved slip factor model coupled with the present correction method provides accurate predictions for mass-averaged absolute circumferential velocity at the exit of impeller near and above the flow rate of peaktotal pressure coefficient.

  • PDF

LOx와 Kerosene을 추진제로 하는 1열 핀틀 분사기의 고압 연소성능 특성에 관한 연구 (Study on the High Pressure Combustion Performance Characteristics of the 1st Row Pintle Injector using LOx-Kerosene as Propellant)

  • 강동혁;김종규;유철성;고영성
    • 항공우주시스템공학회지
    • /
    • 제16권5호
    • /
    • pp.17-25
    • /
    • 2022
  • 액체로켓엔진의 중요한 특성인 연소 안정성, 연소효율 및 넓은 범위의 추력 조절 등에서 장점이 많은 핀틀 분사기를 설계 및 제작하여 초임계 조건에서 연소시험을 수행하였다. 핀틀 분사기는 추력 제어 및 제작성을 고려하여 직사각형의 1열 형상의 오리피스를 갖는 핀틀 분사기로 제작하였다. 핀틀 분사기의 연소성능 및 상용 분사기로써의 가능성을 검증하기 위해 TMR(Total Momentum Ratio)과 BF(Blockage Factor)를 변화하여 연소 특성을 분석하였다. 연소시험 결과 열유속은 TMR 증가에 따라 증가하는 경향이 나타났으며, 특성속도 효율은 TMR보다 BF에 영향을 받는 것으로 확인되었다. 따라서 TMR 변화에 둔감한 효율 특성을 갖는 1열 핀틀 분사기는 낮은 연료 차압 조건에서 높은 효율을 달성할 수 있다면, 가변 핀틀 분사기 설계 유연성이 높아질 수 있다.

해안경관 관리를 위한 건축물 경관요소 분석에 관한 연구 - 제주시 애월 해안도로변 건축물을 중심으로 - (A Study on Analysis of the Building Landscape Elements for Coastal Landscape Management - Focused on Buildings along the Coastal Road in Aeowal, Jeju -)

  • 박혜정;박철민
    • 한국농촌건축학회논문집
    • /
    • 제19권4호
    • /
    • pp.77-85
    • /
    • 2017
  • In order to preserve beautiful coastal areas landscapes of Jeju Island's the landscape resource, Jeju Special Self-Governing Province is dedicated to protecting the landscape through legal regulations and deliberations. However, the Coastal Landscape of Jeju Island was continuously damaged by due to increased tourist and high development pressure. Based on buildings along the Coastal Road in Aeowal of Jeju Island, this study focused on Management Status of Coastal Areas Landscapes through the Analysis of Building Landscape Elements. As a result, 1) It was effective to limit the use and scale of buildings through legal regulations such as Use zoning. 2) The result of analysis on the physical landscape elements of buildings showed some of the them have the damage values despite passing the review of Architecture Committee. Therefore Landscape Policies required institutional maintenance. 3) As physical landscape Elements of buildings is a minimum quantitation criterion of not less than 1.5 for D/H, or less than a factor of $27^{\circ}$ for angle of elevation and not less than 7.8m for elevation blockage ratio was presented as a criterion for preventing damage to the minimum Coastal Landscape.

Numerical Study of Important Factors for a Vortex Shedder using Automated Design Cycle

  • Nyein, Su Myat;Xu, He
    • International Journal of Fluid Machinery and Systems
    • /
    • 제8권3호
    • /
    • pp.124-131
    • /
    • 2015
  • The good performance of a vortex shedder is defined by strong and stable vortex generated under the condition of most linearity in Strouhal number and low power loss. In this paper, the flow past a bluff body of circular cylinder with a slit normal to the flow has been analyzed focusing on drag coefficient, linearity of Strouhal number and flow resistance (K-factor). The ANSYS/FLUENT package is used for flow simulation and the integration method of computational code to iSIGHT platform is employed for automated design cycle. This study results the design with (0.20~0.267) blockage ratio and 0.10 slit ratio as the best shedder for vortex flowmeter and this results are in well agreement with the experiment. As the combination of GAMBIT, FLUENT, and iSIGHT substitutes the design parameters automatically according to the input data, this method designs effectively the vortex shedder with less design cycle time and low manufacturing cost eliminating the human intervention bottleneck.

Capillary Hysteresis Model in Unsaturated Flow : State of the Art

  • Park, Chan-Kun;Sonu, Jun-Ho
    • Korean Journal of Hydrosciences
    • /
    • 제4권
    • /
    • pp.33-49
    • /
    • 1993
  • The Purpose of this study is to classify existing hysteresis models and to discuss a possibility of a new type of the hysteresis model. The existing hysteresis models are classified into three types: the interpolation model, the scaling model and the domain model, of which only domain model is to simulate hysteresis curves based on the theoretical approach, It is useful to develop a hysteresis model that requires only one branch of hysteresis curves for the model calibration because obtaining hysteresis curves by experiments is expensive and time-concept by many investigators, however their models are not successful to accurately simulate real data of Rubicon Sandy Loam and Dune Sand. There is a possibility that a new model is based on the dependent domain concept considering the weighting factor, $P_a$($\theta$), which accounts for the pore blockage effect against air entry. Conclusively, a new model where the weighting factor $P_a$($\theta$) in Model III-1 (Mualem, 1984) reduces to a known variable through an appropriate method is an alternative model which required only one branch of main curves for the model calibration.

  • PDF

원자로 부수로내 혼합날개를 지나는 삼차원 열유동 해석 (Numerical Analyses of Three-Dimensional Thermo-fluid flow through Mixing Vane in A Subchannel of Nuclear Reactor)

  • 최상철;김광용
    • 대한기계학회논문집B
    • /
    • 제27권3호
    • /
    • pp.311-318
    • /
    • 2003
  • The present work evaluates the effects of mixing vane shape on the flow structure and heat transfer downstream of mixing vane in a subchannel of fuel assembly. by obtaining velocity and pressure fields. turbulent intensity. flow-mixing factors. heat transfer coefficient and friction factor using three-dimensional RANS analysis. Four different shapes of mixing vane. which were designed by the authors were tested to evaluate the performances in enhancing the heat transfer. Standard k-$\varepsilon$ model is used as a turbulence closure model. and. periodic and symmetry conditions are set as boundary conditions. The flow blockage ratio is kept constant. but the twist angle of mixing vane is changed. The results with three turbulence models were compared with experimental data.

Inhibitory Effect of Kaempferol on Apoptosis Induced by Phorbol Ester via the Reduction of ROS in Normal Human Dermal Fibroblast

  • Park, Su-Ji;Lee, Sei-Jung
    • 한국환경과학회:학술대회논문집
    • /
    • 한국환경과학회 2020년도 정기학술대회 발표논문집
    • /
    • pp.219-219
    • /
    • 2020
  • Kaempferol (3,4',5,7-tetrahydroxyflavone), a flavonoid found in beans, broccoli, garlic, etc., has been used in natural medicine as an anti-inflammatory and antioxidant. This experiment was carried out to evaluate the anti-apoptotic effect of kaempferol in 12-O-tetradecanoylphorbol 13-acetate (TPA)-treated Normal Human Dermal Fibroblast (NHDF). Kaempferol inhibited the production of intracellular Reactive Oxygen Species (ROS) induced by TPA in NHDF. Kaempferol significantly blocks the phosphorylation of extracellular signal-regulated kinase responsible for the activation of nuclear factor-kappa B. In addition, kaempferol significantly attenuated the expression of Bax and cleaved caspase-3 as regulated by the phosphorylation of nuclear factor-kappa B during its blockage of TPA-induced apoptotic cell death. These findings suggest that kaempferol protects the apoptotic signaling pathway induced by TPA through modulating intracellular ROS in NHDF.

  • PDF

교량에 집적된 유송잡물의 배수영향에 의한 홍수피해 분석 (Flood Damage Estimation causing Backwater due to the Blockage by Debris in the Bridges)

  • 김수전;정재학;이종설;김지태
    • 한국방재학회 논문집
    • /
    • 제7권4호
    • /
    • pp.59-66
    • /
    • 2007
  • 하천을 횡단하는 교량은 하천의 배수위를 증가시키는 중요한 요인으로 작용한다. 더욱이 산지하천에 시공된 교량은 유송잡물에 의한 폐색으로 인하여 교량 직상류부에 홍수피해를 가중시킨다. 본 연구에서는 교각에 집적되는 유송잡물의 영향으로 인해 발생할 수 있는 홍수피해 규모를 확인하고자 대상하천에 대한 HEC-RAS 모형과 HEC-GeoRAS 모형을 구축하여 모의하였다. 교각에 집적된 유송잡물에 의한 폐색이 하천의 범람을 일으키는 원인으로 가정하여 범람 시나리오 별로 부정류 모의를 실시한 결과 월류지점 및 홍수용량을 산정하였고, 이에 따라 대략적인 범람예상구역을 작성하였다. 그러나 범람구역의 침수면적과 침수심에 대하여 실제 분석결과를 제대로 반영하지 못하는 한계가 있었다. 따라서 수치지형도와 위성사진을 이용하여 범람예상구역을 재설정하고 수치고도자료 내에서 월류용량과 동일 용량의 침수면적과 침수심을 갖는 범람구역을 재작성하는 과정을 수행함으로써 좀 더 정확한 홍수피해 규모를 산정하였다.