• Title/Summary/Keyword: Block Factor

Search Result 556, Processing Time 0.023 seconds

Random Ordering of Experimental Design According to the Nested Factor, Block Factor and Repetition Types (지분인자, 블록인자와 되풀이 유형에 따른 실험계획의 랜덤화 순서)

  • Choi, Sung-Woon
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2009.04a
    • /
    • pp.177-183
    • /
    • 2009
  • The research develops random ordering methodology of experimental design by the use of nested factor, block factor and repetition types. The spreadsheets developed are useful for quality practioner to acquire the experimental characteristics according to the random ordering.

  • PDF

Review of Gauge R&R Studies by Restricted and Unrestricted Design in the Two-Factor Mixed Model (2인자 혼합모형의 제약과 비제약 설계에 의한 게이지 R&R 연구의 고찰)

  • Choi, Sung-Woon
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2009.11a
    • /
    • pp.657-665
    • /
    • 2009
  • The paper reviews gauge R&R studies by two-factor mixed models including random and fixed factors. The two-factor mixed models include restricted models and unrestricted models considering the interaction of two factors. This study also classifies the models according to the number of factors, and the combination of various factors such as random factor, fixed factor, block factor and repetition type.

  • PDF

Development of Flow Control Block for Hydraulic System of Tunnel Boring Machine (터널 굴착기 유압시스템용 유량 제어 블록 개발)

  • Lee, Jae-Dong;Lim, Sang-Jin
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.20 no.6
    • /
    • pp.929-935
    • /
    • 2018
  • This paper develops a flow control block for a hydraulic system of a tunnel boring machine. The flow control block is a necessary component to ensure stability in the operation of the hydraulic system. In order to know the pressure distribution of the flow control block, the flow analysis was performed using the ANSYS-CFX. It was confirmed that the pressure and flow rate were normally supplied to the hydraulic system even if one of the four ports of the flow control block was not operated. In order to evaluate the structural stability of the flow control block, structural analysis was performed using the ANSYS WORKBENCH. As a result, the safety factor of the flow control block is 1.54 and the structural stability is secured.

A Blocking Artifacts Reduction Algorithm for Block-Transform coding Image

  • Han, Byung-Hyeok;Kim, Jean-Youn;Lee, Chi-Woo;Jin, Hyun-Joon;Park, Nho-Kyung
    • Proceedings of the IEEK Conference
    • /
    • 2000.07a
    • /
    • pp.437-440
    • /
    • 2000
  • This paper proposes a method to improve video quality on images that have blocking artifacts at block boundary. Block image transform coding suffers from blocking artifact that is a main cause of degrading video quality because of the quantization error of transform coefficients in quantization process. filtering and DPCM for DC components have been widely used to reduce blocking artifact. Recently, lots of works focus on the technique that minimizes block effects using discontinuity of block boundaries. In this paper, image blurring in decoding stage is improved by adding compensation factor to each transformed blocks so that discontinuity of block boundaries can be decreased. The compensation factor is applied on each block without much loss of edge components.

  • PDF

Block Shear Rupture and Shear Lag of Single angle in Tension Joint -Single angle with three or four bolt connection- (단일 ㄱ형강의 블록전단 파단 및 전단지체 현상 -고력볼트 3개 또는 4개로 접합된 단일 ㄱ형강-)

  • Lee, Hyang Ha;Shim, Hyun Ju;Lee, Eun Taik
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.5 s.72
    • /
    • pp.565-574
    • /
    • 2004
  • The purpose of this paper was to investigate the block shear and the fracture in the net section, according to AISC Specifications, by analysing the shear lag effect in the block shear rupture of the single angle with three or four bolt connection. Specimen with three or four bolt connections showed that failure generally went from block shear with some net section failures to classic net section failures. From the test results, showed that the connection length, the thickness of angle, and reduction factor, which affect the block shear rupture, were investigated. According to the test results, it is suggested that the calculation of the net section rupture capacity by using the reduction factor of U, that was suggested by Kulak, is needed.

ON THE RETRACTS AND RECODINGS OF CONTINUING CODES

  • YOO, JISANG
    • Bulletin of the Korean Mathematical Society
    • /
    • v.52 no.4
    • /
    • pp.1375-1382
    • /
    • 2015
  • We investigate what happens when we try to work with continuing block codes (i.e., left or right continuing factor maps) between shift spaces that may not be shifts of finite type. For example, we demonstrate that continuing block codes on strictly sofic shifts do not behave as well as those on shifts of finite type; a continuing block code on a sofic shift need not have a uniformly bounded retract, unlike one on a shift of finite type. A right eresolving code on a sofic shift can display any behavior arbitrary block codes can have. We also show that a right continuing factor of a shift of finite type is always a shift of finite type.

A control of the parallel IGBT Converter for Auxiliary Block of High Speed Train

  • Geun-Woo Oh
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.543-547
    • /
    • 2000
  • Power factor and harmonics are increasingly important for high speed train auxiliary block. This paper presents experimental results of the power factor and harmonic performance of two parallel PWM circuits under various supply and load conditions. For reducing harmonics the harmonic content is eliminated by the phase shift between two converters switching phase. Experimental results show the usefulness of the proposed method and applicability to PWM converter in auxiliary block of high speed train.

  • PDF

A Study on 4 Parallel IGBT PWM Converter for High Speed Train Auxiliary Block (고속전철 보조전원장치용 4병렬 IGBT PWM 컨버터에 관한 연구)

  • 김연충
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.274-277
    • /
    • 2000
  • Power factor and harmonics are increasingly important for high speed train auxiliary block. This paper presents experimental results of the power factor and harmonic performance of four parallel PWM converter circuits under various supply and load conditions. For reducing harmonics the harmonic content is eliminated by the phase shift between four converters switching phase. Experimental results show the usefulness of the proposed method and applicability to PWM converter in auxiliary block of high speed train.

  • PDF

Stroke after the Procedure of Lumbar Facet Joint block and Lumbar Epidural Block -Case reports- (요부 추간관절차단 및 요부 경막외차단 후 발생한 뇌졸증 -증례 보고-)

  • Lee, Hyo-Keun;Kim, Sung-Mo;Han, Kyung-Ream;Lee, Jong-Moo;Ko, Seok-Shin;Kim, Chan
    • The Korean Journal of Pain
    • /
    • v.10 no.1
    • /
    • pp.131-133
    • /
    • 1997
  • Number of elderly patients requiring nerve blocks have been increasing in recent years. We had two elderly patients who suffered stroke one day and three days after lumbar facet joint block and lumbar single epidural block respectively. Both patients due to their advanced age had potential risk factor to suffer one or more of the following; stroke, hypertension, and diabetes mellitus. Due to our experience with these patients, we suggested the following: (1) Nerve blocks should be reconsidered for elderly patient who posesses a potential risk factor to suffer a stroke. (2) Prior to invasive block administration of mild sedatives or analgesics may provide beneficial effects for patients with hypertension. (3) Adequately informed consent must be fully discussed time of consultation with patient scheduled for nerve block especially for elderly and risky patient.

  • PDF

Resistivity Analysis of Model Block for Grounding Electrodes (접지전극을 고려한 모형블록의 저항률 분석)

  • Koh, Hee-Seog;Kim, Sung-Sam;Choi, Jong-Kyu
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.437-439
    • /
    • 2007
  • This paper was analyzed the resistivity change characteristic of mortar model block and concrete that was made earth electrode that's used concrete or basic concrete of building for 1 year. The early resistivity measurement value of concrete model block is higher than mortar model block. But after 1 year the resistivity measurement value of mortar model block is significantly higher than concrete model block. Because depends on time elapsed complete dryness factor of mortar model block that has not gravel is higher than concrete model block. And absorptance and function of mortar mode block was by far outstanding than concrete model block in the data for verification of the amount of contained water and the amount of dryness of mortar model block and concrete model block.

  • PDF