• Title/Summary/Keyword: Blister Test

Search Result 20, Processing Time 0.028 seconds

Performance evaluation of METAMIC neutron absorber in spent fuel storage rack

  • Kim, Kiyoung;Chung, Sunghwan;Hong, Junhee
    • Nuclear Engineering and Technology
    • /
    • v.50 no.5
    • /
    • pp.788-793
    • /
    • 2018
  • High-density spent fuel (SF) storage racks have been installed to increase SF pool capacity. In these SF racks, neutron absorber materials were placed between fuel assemblies allowing the storage of fuel assemblies in close proximity to one another. The purpose of the neutron absorber materials is to preclude neutronic coupling between adjacent fuel assemblies and to maintain the fuel in a subcritical storage condition. METAMIC neutron absorber has been used in high-density storage racks. But, neutron absorber materials can be subject to severe conditions including long-term exposure to gamma radiation and neutron radiation. Recently, some of them have experienced degradation, such as white spots on the surface. Under these conditions, the material must continue to serve its intended function of absorbing neutrons. For the first time in Korea, this article uses a neutron attenuation test to examine the performance of METAMIC surveillance coupons. Also, scanning electron microscope analysis was carried out to verify the white spots that were detected on the surface of METAMIC. In the neutron attenuation test, there was no significant sign of boron loss in most of the METAMIC coupons, but the coupon with white spots had relatively less B-10 content than the others. In the scanning electron microscope analysis, corrosion material was detected in all METAMIC coupons. Especially, it was confirmed that the coupon with white spots contains much more corrosion material than the others.

Characteristic of Electro Deposition Coating for the magnesium alloy after PEO process (마그네슘 합금의 플라즈마 전해 산화 공정 조건에 따른 전착도장 특성)

  • Nam, Seok-Hyeon;Song, Tae-Seung;Seong, Mu-Chang;Park, Min-Ho
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2014.11a
    • /
    • pp.227-228
    • /
    • 2014
  • 마그네슘은 금속 재료중 화학적 활성이 높아 내식성 향상을 위해 표면처리 공정이 반드시 필요하다. 플라즈마 전해 산화를 통한 산화 피막 생성 후 좀더 높은 내식성 향상을 위해 전착 도장법을 사용할 수 있다. 본 논문에서는 전원 인가 방식에 따라 pulse 전원을 on/off 비율에 따른 피막 두께 변화를 측정 하였고 전착 도장을 시행 하여 cross cut test를 통한 부착성 시험을 진행해 on/off 비율 1:4 조건에 250V 전압을 인가 하였을 때 부착성이 가장 우수함을 확인 하였다. 또한 플라즈마 전해 산화 후 탕세 공정을 통해 전착 도장의 내열탕 시험 후 표면 blister의 개선 효과를 얻을 수 있었다.

  • PDF

Design, Fabrication and tTsting of a Microswitch Using Snap-through Buckling Phenomenon (스냅스루 좌굴을 이용한 미소스위치의 설계, 제작 및 실험)

  • Go, Jeung-Sang;Cho, Young-Ho;Kwak, Byung-Man;Park, Kwan-Hum
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.2
    • /
    • pp.481-487
    • /
    • 1996
  • A snapping-beam microswitch has been designed, fabricated and tested. From a design analysis, necessary and sufficient conditions for a snap-through switching fouction have been derived for a clamped shallow beam. The necessary condition has resulted in a geometric relation, in which the ratio of beam thickness to initial beam deflection plays a key role in the snapping ability. The sufficient condition for the snapping action has been obtained as a function of the inertia force due to applied acceleration, and the electrostatic force, adjustable by an inter-electrode voltage. For experimental investigations, a set of microbeams of silicon dioxide/$P^+$silicon bimorphs have been fabricated. Geometric size and mechanical behavior of each material film have been measured from on-chip test structures. Estimated and measured characteristics of the fabricated devices are compared.

Measurements of Adhesion Strength Using Scratch Test (스크래치 시험을 통한 접합력 측정)

  • Lee, Chang-Myeon;Heo, Jin-Yeong;Lee, Hong-Gi
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2015.11a
    • /
    • pp.354-354
    • /
    • 2015
  • 코팅 층과 소지 사이의 접합력 평가를 위하여 박리 시험법(Peel Off Test), 블리스터 시험법(Blister Test), 압입균열 시험법(Indentation Test), 직접 인장 시험법(Direct Full Off Test), 스카치 테이프 시험법(Scotch Tape Test), 그리고 스크래치 시험법(Scratch Test) 등이 사용되어 왔다. 이 중 박리 시험법과 스카치 테이프 시험법이 산업계에서 일반적으로 사용되고 있다. 전자 산업계에서 많이 사용되고 있는 박리시험법은 금속박막과 절연체 기판 사이의 접합력을 간단하게 측정할 수 있으며, 실험값의 재현성이 뛰어난 장점이 있다. 또한, 측정하는 동안 만들어지는 박리 곡선(Peel Curve)로부터 분석의 신뢰성 여부를 확인할 수 있다. 이러한 장점에도 불구하고 박리 시험법 특성 상 금속 코팅층의 강도가 금속 피막/기판간 접합 강도를 초과하여야 하기 때문에 수백 nm 이하의 박막의 접합력 측정에는 적용하기가 어렵다. 이에 반하여, 스카치 테이프 분석법은 일정길이의 접착 테이프를 박막 표면에 붙인 후 다시 떼어내면서 접착력을 평가하는 방법으로, 박막의 접합력 평가에 적용이 가능하다. 그러나 이 방법은 합격 불합격 여부를 판정하는 정성적인 방법으로 정량평가가 어렵다. 또한, 박막에 접착 테이프를 붙일때의 압력, 테이프를 박리할 때의 각도 및 속도를 일정하게 제어하기가 쉽지 않아 결과의 신뢰성이 높지 않다. 스크래치 테스트는 탐사침(Stylus)을 이용하여 박막의 표면에 하중을 증가시키면서 기판을 이동하여, 피막의 균열이나 박리될 때의 임계 하중값 (Critical Load; Lc)을 측정하는 방법이다. 이 방법은 시편 준비가 쉽고 간단하여 빠른 분석이 가능하고, 수백 nm 이하의 박막에도 적용 가능하다. 또한, 접합력을 정량화 할 수 있기 때문에 변수에 따른 접합력 비교가 용이하다는 장점이 있다. 이와 같은 분석적 장점에도 불구하고, 스크래치 시험을 통한 접합력 측정 방법은 아직까진 산업적으로 널리 활용되지 못하고 있다. 따라서, 본 연구에서는 스크래치 테스트의 원리 및 이론에 대하여 간략히 알아보고, 스크래치 분석을 이용한 접합력 비교에 대한 실제 사례들을 소개하고자 하였다.

  • PDF

Studies on the Preparation of Digestive Enzyme Tablest (IV) (소화효소제(消化酵素劑)의 제조(製造)에 관(關)한 연구(硏究) 제4보(第4報))

  • Kim, Yong-Bae;Kim, Whan-Hoe;Yi, Pyong-Kuk;Shin, Hyun-Jong
    • Journal of Pharmaceutical Investigation
    • /
    • v.8 no.4
    • /
    • pp.23-36
    • /
    • 1978
  • Since the active center of digestive enzymetic preparations, while under storage, lose their activity and potency by the exposure to moisture, colorization, solidifying and other physical changes. It is more important than beautiful package form that protected packaging form from moisture to get a pharmaceutical safety preparations and to maintain a definite potency. Then, in order to get a desirable conditions of storage and packaging, we used shellac and $AEA^{\circledR}$ as a coating base, and blister package, foil and bottle container as a packaging material. Temperature were set on room temperature and $37^{\circ}C$, moisture was adjusted to 40% RH and 80 % RH as a accelerated conditions. Accelerated test was carried out 6 times. The results are as follows: 1) The effect of packaging conditions give great influence on the maintenace of the stable potency. 2) Best result was produced with bottle container package. 3) $AEA^{\circledR}$ is more useful than shellac as a coating base of prevention from moisture. 4) Absorption of moisture gave considerable effects on potency and it has a limited point. 5) Difference in potency between optimal and worst condition is 472 u/2T, and difference in effective period is about 44 months.

  • PDF

A Study of Post Electrode Formation by Microwave Sintering in LTCC Substrate (마이크로파 소결법을 이용한 LTCC 기판 Post 전극 형성에 관한 연구)

  • Kim, Yong-Suk;Lee, Taek-Jung;Yoo, Won-Hee;Chang, Byeung-Gyu;Park, Sung-Yeol;Oh, Yong-Soo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.14 no.4
    • /
    • pp.43-48
    • /
    • 2007
  • This study is focused on the effect of the surface properties for the post electrode, which is used in pad formation consisted of SMT such as IC, passive component, combined with fired LTCC substrate, We carried out the surface microstructure of sintered electrode and the basic reliability evaluations with sample fired by microwave sintering to solve the problems occurred in post electrode by electric sintering. We evaluated surface densification status of post electrode according to various conditions of microwave sintering. In additions, it is obtained strong effect on blister improvement of post electrode because of over-sintering and the insufficient out gas in bum out process. As a result of adhesion strength, we confirmed $44.3N/mm^2$ in microwave sintering and $34.5N/mm^2$ in electric sintering, respectively. This result will be used for the basic reliability test. Finally, microwave sintering seems to be economic in process time with 30 min compared to electric sintering with 10 hr. In terms of Mass production and efficiency, microwave sintering are excepted to be higher than electric sintering.

  • PDF

Stress Corrosion Cracking Initiation Behavior of Weldable Structural Steel in $H_2S$ Gas Saturated HCl Solution ($H_2S$ 가스포화 염산수용액에 의한 용접구조용강의 응력부식균열 발생거동)

  • 오세욱;김재철;김광영
    • Journal of Ocean Engineering and Technology
    • /
    • v.4 no.1
    • /
    • pp.88-100
    • /
    • 1990
  • Among the test methods to evaluate stress-corrosion cracking(SCC) on the basis of fracture mechanics, constant displacement(bolt) loading method using modified-WOL specimen is practically convenient. In this test method, compliance formula is generally required to calculate load(consequently $K_{ISCC}$). There are many problems in using the analytic compliance formula to calculate $K_{ISCC}$, so we had proposed the experimental $K_{ISCC}$ evaluation technique in the previous report. This study has employed the slightly altered configuration of modified-WOL specimen made of weldable structural stee(BS360-50D). With these specimens, stress-corrosion tests have been performed in $H_2S$ gas saturated 20% HCl solution. Through the test, the problems as mentioned earlier have been discussed again, and the proposed evaluation technique has been verified. And the stress-corrosion cracks and hydrogen blisters have been investigated in the initiation step with the aids of metallurgical micrographs, SEM fractographs, and EPMA analysis. The inclusions segregated in the mid-thickness region traps hydrogen to produce the hydrogen blistering. The applied or residual stress does not contribute the occurrence of the blister. Hydrogen absorbed into the mid-thickness region is consumed to produce the blistering so that stress-corrosion crack could hardly be detected at that region. The stress-corrosion cracks initiate from the inclusions and propagate in radial pattern. And the initiation site is remote from the crack tip and is inclined from the crack plane, which is assumed to be caused by the triaxial stress and the amount of the absorbed hydrogen.

  • PDF

The study on oriental and western medicine of esophagitis (식도염(食道炎)에 대(對)한 동서의학적(東西醫學的) 고찰(考察))

  • Choi, Chang-woo;Son, Chang-gyu;Cho, Chong-kwan
    • Journal of Haehwa Medicine
    • /
    • v.10 no.2
    • /
    • pp.91-96
    • /
    • 2002
  • We arrived at the following conclusions after we have studied esophagitis through the literatures of oriental and western medicine. 1. The western medical causes of acute esophagitis are corrosiveness chemical material, esophageal or gastric disease, trauma, blister stomatitis, filamentous fungus infection and uremia of chronic patient etc, and the oriental medical causes are qi and blood stagnation, blood stasis and stagnation, stagnant phlegm by coldness, heating, dyspepsia and food poisoning etc. 2. The western medical causes of chronic esophagitis are malfunction of lower esophageal sphincter, esophageal tom chink and hernia, increase of gastric pressure by overeating, fatness, pregnancy and ascites etc, and the oriental medical causes are asthenic cardiac qi, hepatic qi attacking stomach by seven kinds of depression, cold-damp stagnation and insufficiency of gastric qi by overeating, excessive drinking and sexual indulgence etc. 3. The main symptoms of acute esophagitis are severe chest pain, instantly vomiting, swallowing pain etc, and chronic esophagitis are occasionally light chest pain, heart bum, anorexia, dysphagia, dizziness, general body weakness etc. These symptoms are come under thoracic obstruction, acid regurgitation, vomiting and chest pain of oriental medicine. 4. The western medical diagnoses of acute and chronic esophagitis have used radiation test, esophageal endoscopy, esophageal pressure test and biopsy etc, and the oriental medical diagnoses have used syndrome differentiation by four examination of inspection, listening and smelling examination, inquiring, pulse-taking and palpitation. 5. The western medical treatments of acute esophagitis have regarded preservation stability of esophagus as a principle, and the oriental medical treatments mainly have used expelling pathogen of expelling cold and regulating qi, cooling and removing stasis, promoting blood circulation to remove blood stasis, eliminating phlegm and regulating qi. 6. The western medical treatments of chronic esophagitis have regarded decrease flowing backward of gastric juice as a purpose, and the oriental medical treatments mainly have used strengthening body resistance of replenishing and strengthening cardioqi, dispersing stagnated hepatoqi, expelling cold and dehygrosis, invigorating stomach and nourishing qi.

  • PDF

Transdermal Drug Delivery & Therapeutic Effect of the Preparations of Lithospermi Radix and Gardeniae Fructus Extracts on the Burn & Wound Healing (화상 및 창상에 대한 자근.치자 복합제제의 경피 흡수 및 치료효과)

  • Min, Dong-Hoon;Kim, Dae-Keun;Lim, Jong-Pil;Yang, Jae-Heon
    • Journal of Pharmaceutical Investigation
    • /
    • v.35 no.4
    • /
    • pp.255-263
    • /
    • 2005
  • Research was undertaken to compare the pharmacological activity of Lithospermi radix (LR) reported as an oriental medicine for classical uses. LR contains naphthoquinone pigments : shikonin, acetylshikonin, isobutylshikonin, etc. LR is used for the treatment of excision wound, burn, eczema, blister, scarlatina and septicemia as antifebrile, antidotic and antiphlogistic. Gardeniae fructus (GF) has been used for the treatment to jaundice, hepatic disease, anti-inflammatory and analgesic effects, and it contains crocin, geniposide and its derivatives. The therapeutic effects of burn and excision wound healing from LR & GF hydrogel with $Nano-ATP^{\circledR}$ (GLN) were investigated. To evaluate the therapeutic value of various hydrogels, thermal burn model and excision wound mouse model were used. The burn and wound reduction rate and therapeutic period were measured to calculate the healing extent after 5 experiments. The 2nd degree burn was prepared on hairless mouse back skin and dressing with collagen. The burn and wound reduction rate of GLN hydrogel treated group decreased more rapidly than that of other gel group in animal model. Furthermore therapeutic periods of GLN hydrogel treated group was shorter than that of other gel group. In anti-inflammatory test, GLN hydrogel treated group decreased edema rapidly than that of other gel group. These results suggest that the GLN hydrogel treatment has an therapeutic effect on burn and excision wound healing.

Efficacy of various cleaning solutions on saliva-contaminated zirconia for improved resin bonding

  • Kim, Da-Hye;Son, Jun-Sik;Jeong, Seong-Hwa;Kim, Young-Kyung;Kim, Kyo-Han;Kwon, Tae-Yub
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.2
    • /
    • pp.85-92
    • /
    • 2015
  • PURPOSE. This study aimed to investigate the efficacy of cleaning solutions on saliva-contaminated zirconia in comparison to air-abrasion in terms of resin bonding. MATERIALS AND METHODS. For saliva-contaminated air-abraded zirconia, seven cleaning methods)-no contamination (NC), water-spray rinsing (WS), additional air-abrasion (AA), and cleaning with four solutions (Ivoclean [IC]; 1.0 wt% sodium dodecyl sulfate [SDS], 1.0 wt% hydrogen peroxide [HP], and 1.0 wt% sodium hypochlorite [SHC])-were tested. The zirconia surfaces for each group were characterized using various analytical techniques. Three bonded resin (Panavia F 2.0) cylinders (bonding area: $4.5mm^2$) were made on one zirconia disk specimen using the Ultradent jig method [four disks (12 cylinders)/group; a total of 28 disks]. After 5,000 thermocycling, all specimens were subjected to a shear bond strength test with a crosshead speed of 1.0 mm/minute. The fractured surfaces were observed using an optical and scanning electron microscope (SEM). RESULTS. Contact angle measurements showed that groups NC, AA, IC, and SHC had hydrophilic surfaces. The X-ray photoelectron spectroscopy (XPS) analysis showed similar elemental distributions between group AA and groups IC and SHC. Groups IC and SHC showed statistically similar bond strengths to groups NC and AA (P>.05), but not groups SDS and HP (P<.05). For groups WS, SDS, and HP, blister-like bubble formations were observed on the surfaces under SEM. CONCLUSION. Within the limitations of this in vitro study, some of the cleaning solutions (IC or SHC) were effective in removing saliva contamination and enhancing the resin bond strength.