• 제목/요약/키워드: Bipolar PWM

검색결과 45건 처리시간 0.019초

120kW급 IGBT 인버터의 열 응답 특성 실시간 모델 (A Real Time Model of Dynamic Thermal Response for 120kW IGBT Inverter)

  • 임석연;차강일;유상석
    • 한국수소및신에너지학회논문집
    • /
    • 제26권2호
    • /
    • pp.184-191
    • /
    • 2015
  • As the power electronics system increases the frequency, the power loss and thermal management are paid more attention. This research presents a real time model of dissipation power with junction temperature response for 120kw IGBT inverter which is applied to the thermal management of high power IGBT inverter. Since the computational time is critical for real time simulation, look-up tables of IGBT module characteristic curve are implemented. The power loss from IGBT provides a clue to calculate the temperature of each module of IGBT. In this study, temperature of each layer in IGBT is predicted by lumped capacitance analysis of layers with convective heat transfer. The power loss and temperature of layers in IGBT is then communicated due to mutual dependence. In the dynamic model, PWM pulses are employed to calculation real time IGBT and diode power loss. Under Matlab/Simulink$^{(R)}$ environment, the dynamic model is validated with experiment. Results showed that the dynamic response of power loss is closely coupled with effective thermal management. The convective heat transfer is enough to achieve proper thermal management under guideline temperature.

전동차용 IGBT형 190kVA 보조전원장치 개발 (The Development of IGBT Type 190kVA Static Inverter for Electric Car)

  • 김종규;박건태;정기찬;김두식;서광덕
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.634-637
    • /
    • 1997
  • This paper is on the research and development of new SIV(Static Inverter) using IGBT(Insulated Gate Bipolar Transistor) semiconductor for a wide range of electric railway applications. For the simplification and higher controllability, the direct PWM control method with 3level inverter topology was adopted. In the new SIV system, the cost as well as bulk and weight was appreciably reduced about 40% lower than those of conventional SIV, the electrical efficiency was increased above 95% and the audible noise level was less than 65dB. In addition, the THD(Total Harmonic Distortion) factor was below 5% and the voltage fluctuation on a transient state was below 10%.

  • PDF

저손실 스너버 회로를 이용한 유도전동기의 서지전압 억제 (The Sugge Voltage restraint of induction motor using low-loss snubber circuit)

  • 조만철;문상필;김칠용;김주용;서기영;권순걸
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.473-477
    • /
    • 2007
  • The development of advanced Insulated Gate Bipolar Transistor(IGBT)has enabled high-frequency switching operation and has improved the performance of PWM inverters for motor drive. However, the high rate of dv/dt of IGBT has adverse effects on motor insulation stress. In many motor drive applications, the inverter and motor are separated and it requires long motor feds. The long cable contributes high frequency ringing at the motor terminal and it results in hight surge voltage which stresses the motor insulation. The inverter output filter and RDC snubber are conventional method which can reduce the surge voltage. In this paper, we propose the new low loss snubber to reduce the motor terminal surge voltage. The snubber consists of the series connection of charging/discharging capacitor and the voltage-clamped capacitor. At IGBT turn-off, the snubber starts to operate when the IGBT voltage reaches the voltage-clamped level. Since dv/dt is decreased by snubber operating, the peak level of the surge voltage can be reduced. Also the snubber operates at the IGBT voltage above the voltage-clamped level, the snubber loss is largely reduced comparing with RDC snubber. The proposed snubber enables to reduce the motor terminal surge voltage with low loss.

  • PDF

3상 임베디드 Z-소스 인버터 (Three Phase Embedded Z-Source Inverter)

  • 오승열;김세진;정영국;임영철
    • 전력전자학회논문지
    • /
    • 제17권6호
    • /
    • pp.486-494
    • /
    • 2012
  • In this paper, we proposes the three-phase embedded Z-source inverter consisting of the three embedded Z-source converters and it's the output voltage control method. Each embedded Z-source converter can produce the bipolar output capacitor voltages according to duty ratio D such as single-phase PWM inverter. The output AC voltage of the proposed system is obtained as the difference in the output capacitor voltages of each converter, and the L-C output filter is not required. Because the output AC voltage can be stepped up and down, the boost DC converter in the conventional two-stage inverter is unnecessary. To confirm the validity of the proposed system, PSIM simulation and a DSP based experiment were performed under the condition of the input DC voltage 38V, load $100{\Omega}$, and switching frequency 30kHz. Each converter is connected by Y-connection for three-phase loads. In case that the output phase voltage is the same $38V_{peak}$ as the input DC voltage and is the 1.5 times($57V_{peak}$), the simulation and experimental results ; capacitor voltages, output phase voltages, output line voltages, inductor currents, and switch voltages were verified and discussed.

ESD 보호 소자를 탑재한 Peak Current-mode DC-DC Buck Converter (A Design of Peak Current-mode DC-DC Buck Converter with ESD Protection Devices)

  • 박준수;송보배;유대열;이주영;구용서
    • 전기전자학회논문지
    • /
    • 제17권1호
    • /
    • pp.77-82
    • /
    • 2013
  • 본 논문에서는 인덕터의 흐르는 전류를 감지하여 출력 전압을 일정하게 유지시키는 Peak Current-mode 방식의 DC-DC Buck Converter를 제안하고, 소신호 모델링에 기초하여 Power Stage 설계 방법과 시스템의 안정도를 설계하는 방법을 제안한다. 또한, dc-dc 컨버터의 신뢰성과 성능을 향상시키기 위해 보호회로를 추가하였다. 그리고 정전기 방지를 위하여 ESD 보호회로를 제안하였다. 제안된 보호회로는 게이트-기판 바이어싱 기술을 이용하여 낮은 트리거 전압을 구현하였다. 시뮬레이션 결과는 일반적인 ggNMOS의 트리거 전압(8.2V) 에 비해 고안된 소자의 트리거 전압은 4.1V 으로 더 낮은 트리거 전압 특성을 나타냈다. 본 논문에서 제안하는 회로의 시뮬레이션은 0.35um BCB 공정 파라미터를 이용하였고, Mathworks 사의 Mathlab과 Synopsys 사의 HSPICE 프로그램을 사용하여 검증하였다.