• Title/Summary/Keyword: Biomedical technology

Search Result 2,698, Processing Time 0.03 seconds

Estimation and Implementation of the Uroflowmetry Using Load Cell (로드셀을 이용한 요류검사기의 구현 및 평가)

  • Jeong, Do-Un;Cho, Seong-Taek;Nam, Ki-Gon;Chung, Moon-Kee;Jeon, Gye-Rok
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.6
    • /
    • pp.436-445
    • /
    • 2004
  • In this study, a uroflowmetry system was developed to detect a voiding symptom conveniently at home or hospital. A implemented hardware was composed of mechanism and system circuit part, the software was developed to process uroflow data, graph display, extraction of parameter, and evaluation of congregate rate so as to analysis obtaining uroflow data. The following experiment was performed to evaluate an ability of classification and fitness. The curve pattern of uroflow was classified into each symptom. Various parameters were calculated in the curve pattern of each uroflow as follows. The parameters are MFR, AFR, VOL, VT, and FT. A significant difference among parameters was examined by a statistical analysis for extracted parameters between normal and abnormal experimental group. The uroflow data with the various symptom was divided into normal and abnormal group using fuzzy classifier. The result of the fuzzy classification using MFR and AFR was superior by 91.23 % than grouping evaluation including VOL.

Simultaneous Evaluation of Cellular Vitality and Drug Penetration in Multicellular Layers of Human Cancer Cells

  • Al-Abd Ahmed Mohammed;Lee Joo-Ho;Kuh Hyo-Jeong
    • Journal of Pharmaceutical Investigation
    • /
    • v.36 no.5
    • /
    • pp.309-314
    • /
    • 2006
  • The multicellular layers(MCL) of human cancer cells is a three dimensional(3D) in vitro model for human solid tumors which has been used primarily for the assessment of avascular penetration of anti-cancer drugs. For anti-cancer drugs with penetration problem, MCL represents a good experimental model that can provide clinically relevant data. Calcein-AM is a fluorescent dye that demonstrates the cellular vitality in a graded manner in cancer cell culture system. In the present study, we evaluated the use of calcein-AM for determination of anti-proliferative activity of anti-cancer agents in MCL model of DLD-1 human colorectal cancer cells. Optical sectioning of confocal imaging was compromised with photonic attenuation and penetration barrier in the deep layers of MCL. By contrast, fluorescent measurement on the cryo-sections provided a feasible alternative. Cold pre-incubation did not enhance the calcein-AM distribution to a significant degree in MCL of DLD-1 cells. However, the simultaneous determination of drug penetration and cellular vitality appeared to be possible in drug treated MCL. In conclusion, these data suggest that calcein-AM can be used for the simultaneous determination of drug-induced anti-proliferative effect and drug penetration in MCL model.

Low-temperature Sintering Behavior of TiO2 Activated with CuO

  • Paek, Yeong-Kyeun;Shin, Chang-Keun;Oh, Kyung-Sik;Chung, Tai-Joo;Cho, Hyoung Jin
    • Journal of the Korean Ceramic Society
    • /
    • v.53 no.6
    • /
    • pp.682-688
    • /
    • 2016
  • In $TiO_2$-CuO systems, low-temperature sinterability was investigated by a conventional sintering method. Sintering temperatures were set at under $950^{\circ}C$, at which the volume diffusion is inactive. The temperatures are less than the melting point of Ag ($961^{\circ}C$), which is often used as an internal conductor in low-temperature co-fired ceramic technology. To optimize the amount of CuO dopant, various dopant contents were added. The optimum level for enhanced densification was 2 wt% CuO. Excess dopants were segregated to the grain boundaries. The segregated dopants supplied a high diffusion path, by which grain boundary diffusion improved. At lower temperatures in the solid state region, grain boundary diffusion was the principal mass transport mechanism for densification. The enhanced grain boundary diffusion, therefore, improved densification. In this regard, the results of this study prove that the sintering mechanism was the same as that of activated sintering.

Cancelation of Baseline Wandering of Electroglottograph Signal using Empirical Mode Decomposition (경험적 모드 재구성 방법을 이용한 성문파형 신호의 기계선 변동 제거)

  • Jang, Seung-Jin;Kim, Hyo-Min;Park, Young-Cheol;Choi, Hong-Shik;Yoon, Young-Ro
    • Proceedings of the KIEE Conference
    • /
    • 2007.10a
    • /
    • pp.475-476
    • /
    • 2007
  • Electroglottography (EGG) is a technique used to register laryngeal behavior indirectly by a measuring the change in electrical impedance across the throat during speaking. However, EGG waveform is affected by laryngeal muscles which fluctuate the vocal cords, and which result in baseline wander. It is required to reduce baseline wander in EGG waveform, because EGG waveform is used for input signal of nonlinear speech synthesizer in next chapter. In vocal cords, the abduction-adduction of glottis is mainly controlled by the posterior cricoarytenoid (abductor) and interarytenoid (adductor) muscles respectively. Empirical Mode Decomposition method was adopted in cancellation of EGG waveform baseline wandering, and showd better performance than that of high pass filter with 500 order.

  • PDF

Development of multi-colorimeter module for low-cost urinalysis strip readers (저가형 요분석 시스템의 다중 광 검출 모듈개발)

  • Ye, Soo-Young;Jeon, Yong-Uk;Jeong, Do-Un;Jeon, Gye-Rok;Ro, Jung-Hoon
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.5
    • /
    • pp.387-395
    • /
    • 2008
  • An optic module system is developed adopting multiple colorimetry units for the measurement of multi-pad urinalysis dipsticks. Multiple photometry system instead of moving mechanisms has the advantages of system reliability and simplicity as well as economic aspects due to the recent development of economic color light emitting diodes and stable photo sensors. An integration amplifier with programmable integration time, a current source circuit with selectable and stable current settings were connected through analog multiplexers to thirty light emitting diodes for illumination and ten photo transistors for reading each strip pad. All the circuits are controlled by a microprocessor through a simple set of serial communication commands. The detect ability is eighteen times better than the minimum color difference of the test grading which is 0.013 in urobilinogen in the color space defined in this paper.

Effects of Somatosensory Stimulation on Lower-Limb Joint Kinetic of Older Adult During Stair Descent (계단 하강 보행 동안 체성감각 자극이 노인의 하지 관절 역학에 미치는 영향)

  • Kwak, K.Y.;So, H.J.;Kim, S.H.;Yang, Y.S.;Kim, N.G.;Kim, D.W.
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.2
    • /
    • pp.93-104
    • /
    • 2011
  • The purpose of this study was to investigate lower-limb joint torque of the two groups as it changed by somatosensory stimulation during the descent down three stairs of different heights and to describe the difference between the two groups, which are young people group and elderly people group. Subjects of each groups climbed down a stair at four stimulation conditions, which are non-stimulation, tibialis anterior tendon stimulation, achilles tendon stimulation, tibialis anterior - achilles tendon stimulation. Motion capture data were collected using 3D optoelectric motion tracking system that utilizes active infrared LEDs, near infrared sensor and force plate. The obtained motion capture data was used to build 3D computer simulation model. The results show that lower-limb joint torque of the two groups changed with somatosensory stimulation as they descended the stairs and the joint torque of the two groups differed from each other.

Image Quality of Amorphous Selenium DR system using MTF measurement (MTF 측정을 통한 비정질 셀레늄 기반의 디지털 방사선 검출기의 영상 질 평가에 관한 연구)

  • Seok, Dae-Woo;Park, Ji-Koon;Choi, Jang-Yong;Nam, Sang-Hee;Kang, Shin-Won
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.384-387
    • /
    • 2003
  • In this paper, the evaluation of image quality was performed for digital radiography which is developing in using amorphous selenium as a photoconductor material for the purpose of offering basic research data and measurement technique about Medical Imaging Quality. So Modulation Transfer Function as a main factor of imaging quality evaluation was investigated by slit method. For measurement of MTF, Nuclear associates. 07-624 Slit camera image was obtained to study the variation of MTF corresponding to changing spatial frequency. And Presampling MTF was estimated by slit camera image with $10\;{\mu}m$ width at Digital Radiography. In this study, the obtained data demonstrates that the clinical value of a direct conversion type digital radiation detector using the amorphous selenium, which is being developed by domestic technology.

  • PDF

Characteristic of DLC Thin Film Fabricated by FVAS Method on Tungsten Carbide (초경합금에 FVAS로 코팅한 DLC 박막의 특성)

  • Cheon, Min-Woo;Park, Yong-Pil;Kim, Tae-Gon;Lee, Ho-Shik
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.10
    • /
    • pp.812-816
    • /
    • 2011
  • An optical lens is usually produced in the manner of high temperature compression molding with tungsten carbide alloy molding cores, it is necessary to develop and study technology for super-precision processing of molding cores and coating the core surface. As main methods used in surface improvement technologies using thin film, DLC present high hardness, chemical stability, and outstanding durability of abrasion to be extensively applied in various industrial fields. In this study, the effect of DLC coating of a thin film by means of the FVAS (filtered vacuum arc source) analyzed the characteristics of thin film. Surface roughness before and after DLC coating was measured and the result showed that the surface roughness was improved after coating as compared to before coating. In conclusion, it was observed that DLC coating of the ultra hard alloy core surface for molding had an effect on improving the surface roughness and shape of the core surface. It is considered that this will have an effect on improving abrasion resistance and the service life of the core surface.

Effect of ${\gamma}$-Ray Irradiation on Surface Oxidation of Ultra High Molecular Weight Polyethylene/Zirconia Composite Prepared by in situ Ziegler-Natta Polymerization

  • Kwak, Soon-Jong;Noh, Dong-Il;Chun, Heung-Jae;Lim, Youn-Mook;Nho, Young-Chang;Jang, Ju-Woong;Shim, Young-Bock
    • Macromolecular Research
    • /
    • v.17 no.8
    • /
    • pp.603-608
    • /
    • 2009
  • Novel ultra-high molecular weight polyethylene (UHMWPE)/zirconia composites were previously prepared by the in situ polymerization of ethylene using a Ti-based Ziegler-Natta catalyst supported on to the surface of zirconia, as a bearing material for artificial joints. Tribological tests revealed that a uniform dispersion of zirconia in UHMWPE markedly increased the wear resistance. The effects of zirconia content on the oxidation behavior of the ${\gamma}$-ray-treated UHMWPE/zirconia composite surfaces were examined. The oxidation index that estimates the oxidation degree as the content of total carbonyl compounds was monitored using Fourier transform infrared spectroscopy-attenuated total reflectance. The changes in the surface composition due to the oxidation were confirmed by electron spectroscopy for chemical analysis. The extent of oxidation decreased with increasing zirconia content, which was attributed to the increased crystallinity as well as the decreased polymer portion of the UHMWPE/zirconia composites.

A Phylogenetic Study of Scirpus planiculmis F. Schm. (Cyperaceae) Based on ITS1 Sequences of Nuclear Ribosomal DNA

  • Jang, Wol-Suk;Kang, Hye-Sook;Han, In-Seop;Lee, Sun-Hee
    • Journal of agriculture & life science
    • /
    • v.45 no.6
    • /
    • pp.1-7
    • /
    • 2011
  • This work was performed to confirm the molecular discrimination through the nrITS1 sequences among 3 taxa of Scirpus L. sensu lato (s.l.) species. S. planiculmis represented only 2 base sequence variations with S. maritimus in spite that they showed different morphological features. The nucleotide sequences of the ITS1 region from S. planiculmis were shown to have 99.1% homology with S. maritimus and 60.4% homology with S. triqueter. Although the morphology of S. planiculmis is similar with S. triqueter, molecular basis of the size and sequences on ITS1 region were shown to have distinctive differences. For divergency investigation on same sites and metapopulation, sequencing was conducted on ITS1 region with partial 5.8S and 18S regions. All plants of each species collected at the same site had identical band size pattern and sequences. Intraspecific molecular divergency was not identified in spite that these species live in different wetland sites. The ITS1 sequences described here provided a powerful genetic tool for phylogenetic studies which was difficult by morphological identification as high rate of morphological plasticity.