• Title/Summary/Keyword: Biomedical polymer

Search Result 318, Processing Time 0.026 seconds

Modeling of IPMC (Ionic Polymer-Metal Composite) Sensor to Effectively Detect the Bending Angles of a Body

  • Park, Ki-Won
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.6
    • /
    • pp.375-381
    • /
    • 2011
  • Ionic polymer-metal composite(IPMC) consists of an ion conductive membrane plated by metallic electrodes on both surfaces. When it bends, a voltage is generated between two electrodes. Since IPMC is flexible and thin, it can be easily mounted on the various surfaces of a body. The present study investigates a sensor system using IPMC to effectively detect the bending angles applied on IPMC sensor. The paper evaluates several R and C circuit models that describe the physical composition of IPMC and selects the best model for the detection of angles. The circuit models implemented with a charge model describe the relationship between input bending angles and output voltages. The identification of R and C values was performed by minimizing the error between the real output voltages and the simulated output voltages from the circuit models of IPMC sensor. Then the output signal of a sensor was fed into the inverse model of the identified model to reproduce the bending angles. In order to support the validation of the model, the output voltages from an arbitrary bending motion were also applied to the selected inverse model, which successfully reproduced the arbitrary bending motion.

Synthesis and Characteristics of Hyaluronic Acid Bead Crosslinked by 1,3-Butadiene diepoxide (1,3-Butadiene diepoxide에 의해 가교된 히아루론산 비드의 제조 및 특성)

  • Kwon, Ji-Young;Cheong, Seong-Ihl
    • Polymer(Korea)
    • /
    • v.29 no.5
    • /
    • pp.445-450
    • /
    • 2005
  • Hyaluronic acid-based beads were prepared in order to develop a biomedical material for augumentation. Hyaluronic acid was crosslinked by 1,3-butadiene diepoxide in a suspension state maintained by rapid mixing of soybeen oil and hyaluronic acid solution. The particle size, surface area and swelling ratio were measured to investigate the physical properties of the synthesized beads and the bead surface was examined by scanning electron microscopy. The beads were formed in the range of $5-12vol\%$ concentration of crosslinking agent, which showed monodisperse size distribution. Both BET surface area and swelling ratio decreased as the concentration of either hyaluronic acid or crosslinking agent increased, and crosslinking temperature decreased. Bead size could be effectively controlled by mixing speed without affecting other physical property.

Characteristic Change of PVDF-$SiO_2$ Composite Nanofibers with Different Thermal Treatment Temperature (열처리 온도에 따른 PVDF-$SiO_2$ 복합나노섬유의 특성 변화)

  • Kim, Young-Jin
    • Polymer(Korea)
    • /
    • v.35 no.6
    • /
    • pp.605-609
    • /
    • 2011
  • Composite nanofibers were prepared by electrospinning and thermal treatment from poly (vinylidene fluoride) (PVDF)-$SiO_2$ blend solution. The nanofibers were stacked on layers to produce fully interconnected pores. TEM micrographs and EDX spectra confirmed the presence of $SiO_2$ in the composite nanofibers. The porosity of nanofibers was effectively enhanced by the introduction of electrospinning technique. ATR-FTIR and XRD results revealed that PVDF in the composite nanofibers exhibited the mixture crystal structure of ${\alpha}$-phase and ${\beta}$-phase. The crystal structure of ${\alpha}$-phase and crystallinity increased by the thermal treatment. In addition, the mechanical properties, thermal stability and hydrophobicity were markedly amplified by the thermal treatment.

Study of Miscibility of Natural Silk by Molecular Dynamics Calculation of Solubility Parameter (용해도 파라미터의 분자동역학 계산을 통한 천연 실크 소재의 혼화성 연구)

  • Im, Keunan;Choi, Kang-min;Leem, Jung Woo;Kim, Young L.;Park, Chi Hoon;Jang, Hae Nam
    • Membrane Journal
    • /
    • v.31 no.2
    • /
    • pp.153-159
    • /
    • 2021
  • In recent years, polymer membranes, which are actively used in various industrial fields, have the advantage of being able to impart unique properties through the control of chemical structures and physical properties in the film-fabrication process, as well as through fabricating blend membranes mixed with various materials. In this study, the solubility parameter, which can be used as an index of miscibility with other materials, was calculated using molecular dynamics using a silkworm (Bombyx mori) silk polymer which has a wide potential to be used as an eco-friendly natural material. When the solubility parameter of polyvinylalcohol (PVA), which is also environmentally friendly and biocompatible, was calculated by molecular dynamics and compared with each other, it was confirmed that the two polymer materials had similar solubility parameter values. In conclusion, it was theoretically proved that the two polymers could blend well with each other, which was confirmed through experiments.

THE EFFECT OF A CHITOSAN COATING OF DENTAL IMPLANT ON THE SHOCK ABSORPTION UNDER IMPACT TEST (키토산으로 표면처리된 인공치아의 충격전달에 관한 연구)

  • Kim, Ki-Hong;Lee, Yong-Chan;Cho, Byoung-Ouck;Choi, Kui-Won;Kwon, Ick-Chan;Bae, Tae-Soo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.27 no.1
    • /
    • pp.9-14
    • /
    • 2001
  • With the object of providing a temporary artificial periodonal ligament-like membrane around the dental implant, 10 Branemark type implants were coated with commercially available chitosan(Fluka Co., Buchs, Switzerland) which has a molecular weight of 70,000 and 80% deacetylation degree. Once this bioactive hydrophillic polymer(chitosan) contacts with blood or wound fluids, it becomes swollen and penetrates into the adjacent cancellous bone. Thus the interface between implant and surrounding bone is completely filled with chitosan. This tight junction in early healing phase enhances primary stability. The chitosan coated dental implants were implanted into the fresh patella bones from porcine knees, since the thickness of cortical bone is relatively even and their cancellous structure is homogenous. To test the shock absorbing effect, 1mm delta-rogette strain gage was installed behind the implant. The results showed 1. The principal strain peak value directed to the impact of coated implant was 0.064 0.018(p<0.05) and that of uncoated implant was 0.095(0.032 p<0.05). 2. The peak time delay of coated implant was 0.056sec(0.011 p<0.05) and that of uncoated implant was 0.024sec(0.009 p<0.05). It can be reasoned from this results that the chitosan coating has a shock absorbing effect comparable with a temporary artificial periodontal ligament.

  • PDF

Anti-complement Effects of Anion-Substituted Poly(vinyl alcohol) Membranes

  • Ryu, Kyu-Eun;Rhim, Hyang-Shuk;Park, Chong-Won;Chun, Heung-Jae;Hong, Seung-Hwa;Kim, Young-Chai;Lee, Young-Moo
    • Macromolecular Research
    • /
    • v.12 no.1
    • /
    • pp.46-52
    • /
    • 2004
  • In a continuation of our previous studies on blood compatibility profiles of anion-substituted poly(vinyl alcohol) (PVA) membranes, in which hydroxyl groups have been replaced with carboxymethyl (C-PVA) and sulfonyl groups (S-PVA), we have studied the activation of complement components and the changes in white cell and platelet count in vitro and compared them with those of unmodified PVA, Cuprophane, and low-density polyethylene. Complement activation of fluid phase components, C3a, Bb, iC3b, and SC5b-9, and of bound phases, C3c, C3d, and SC5b-9, were assessed by enzyme-linked immunosorbent assay (ELISA) and immunoblot, respectively. The changes in the number of white cells and platelets following complement activation were counted using a Coulter counter. C-PVA and S-PVA activated C3 to a lesser extent than did PVA, which we attribute to the diminished level of surface nucleophiles of the samples. In addition, C- and S-PVA exhibit increased inhibition of Bb production, resulting in a decrease in the extent of C5 activation. Consequently, because of the reduced activation of C3 and C5, C- and S-PVA samples cause marked decreases in the SC5b-9 levels in plasma. We also found that the negatively charged sulfonate and carboxylate groups of the samples cause a greater extent of adsorbtion of the positively charged anaphylatoxins, C3a and C5a, because of strong electrostatic attraction, which in turn provides an inhibition of chemotaxis and activation of leukocytes. The ability to inhibit complement production, together with the binding ability of anaphylatoxins of the C- and S-PVA samples, leads to a prominent decrease in lysis of leukocytes as well as activation of platelets.

Efficiency of PDNR (Polydeoxyribonucleotide) extraction from various plant species and its in vitro wound healing activity (다양한 식물에서의 PDRN(Polydeoxyribonucleotide) 추출 수율 비교 및 상처치유 효능 분석)

  • Song, Mi-Hee;Choi, Moon-Hyeok;Jeong, Jin-Hyoung;Lee, Sang-Sik;Jeong, Woo-Young
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.5
    • /
    • pp.387-395
    • /
    • 2022
  • PDRN (Polydeoxyribonucleotide) is a DNA-derived polymer that promotes self-renewal of damaged cells and tissues as a tissue regeneration active material. PDRN is a DNA fragment cut into small sizes by various physical or chemical methods. When administered to the body, PDRN binds and stimulates the adenosine A2A receptor on the surface of tissue cells to promote cell regeneration, accelerate wound healing, and reduce pain. Although PDRN is prepared from testis or semen of fish in most cass, PDRN extraction from various plants species was performed in the present study. Among 7 tested plant species, the highest DNA yield and purity was obtained form mugwort (Chrysanthemum coronarium, C.c), followed by broccoli (Brassica oleracea, B.o). Then, we evaluated the in vitro wound healing capacity of PDRNs prepared from these two selected plants. PDRN from C.c and B.o. significantly stimulated the wound healing process at ㎍/ml range. The present study suggests that PDRN from plant species can be an effective alternative to PDRN from marine organism.

Preparation and Characterization of O-Carboxymethyl Chitosan Ion-complexed Poly(L-Lysine) for Drug and Gene Delivery System (약물 및 유전자 전달체로 응용하기 위한 Poly(L-Lysine)이 결합된 O-Carboxymethyl Chitosan PEG의 제조와 특성)

  • Nam, Joung-Pyo;Kim, Young-Min;Park, Jin-Su;Lee, Eung-Jae;Choi, Chang-Yong;Jang, Mi-Kyeong;Nah, Jae-Woon
    • Applied Chemistry for Engineering
    • /
    • v.21 no.6
    • /
    • pp.643-647
    • /
    • 2010
  • O-carboxymethyl water-soluble chitosan (OCMCh) prepared for enhance the application of chitosan was modified with mthoxy polyethyleneglycol (mPEG) by ion-complex for long circulation in the blood. OCMCh-PEG-PLLs was prepared by forming ion-complex with OCMCh-PEG and Poly(L-Lysine) (PLL) for drug and gene delivery system. The physicochemcal characterisitcs of OCMCh-PEG-PLLs were investigated by FT-IR, $^1H$-NMR. These results showed that CMCh-PEG-PLLs were successfully syntehsized by ion-complex. Particle size distribution and zeta potential of the OCMCh-PEG-PLLs were determined using dynamic light scattering technique. Transmission electron microscopy (TEM) was also used to observe the morphology of the OCMCh-PEG-PLLs. OCMCh-PEG-PLLs have spherical shapes with particle size 290∼390 nm. OCMCh-PEG-PLLs were showed when the feeding amount of mPEG ratio was increased, particle size and zeta potential were decreased. Based on these results, it is possible to introduction of the OCMCh-PEG-PLLs into various biomedical fields such as drug and gene delivery system.

Implantable Flexible Sensor for Telemetrical Real-Time Blood Pressure Monitoring using Polymer/Metal Multilayer Processing Technique (폴리머/ 금속 다층 공정 기술을 이용한 실시간 혈압 모니터링을 위한 유연한 생체 삽입형 센서)

  • Lim Chang-Hyun;Kim Yong-Jun;Yoon Young-Ro;Yoon Hyoung-Ro;Shin Tae-Min
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.599-604
    • /
    • 2004
  • Implantable flexible sensor using polymer/metal multilayer processing technique for telemetrical real-time blood pressure monitoring is presented. The realized sensor is mechanically flexible, which can be less invasively implanted and attached on the outside of blood vessel to monitor the variation of blood pressure. Therefore, unlike conventional detecting methods which install sensor on the inside of vessel, the suggested monitoring method can monitor the relative blood pressure without injuring blood vessel. The major factor of sudden death of adults is a disease of artery like angina pectoris and myocardial infarction. A disease of circulatory system resulted from vessel occlusion by plaque can be preventable and treatable early through continuous blood pressure monitoring. The procedure of suggested new method for monitoring variation of blood pressure is as follows. First, integrated sensor is attached to the outer wall of blood vessel. Second, it detects mechanical contraction and expansion of blood vessel. And then, reader antenna recognizes it using telemetrical method as the relative variation of blood pressure. There are not any active devices in the sensor system; therefore, the transmission of energy and signal depends on the principle of mutual inductance between internal antenna of LC resonator and external antenna of reader. To confirm the feasibility of the sensing mechanism, in vitro experiment using silicone rubber tubing and blood is practiced. First of all, pressure is applied to the silicone tubing which is filled by blood. Then the shift of resonant frequency with the change of applied pressure is measured. The frequency of 2.4 MHz is varied while the applied pressure is changed from 0 to 213.3 kPa. Therefore, the sensitivity of implantable blood pressure is 11.25 kHz/kPa.

Fabrication and Characterization of PCL/TiO2 Nanoparticle 3D Scaffold (PCL/TiO2 Nanoparticle 3차원 지지체 제조 및 특성 평가)

  • Kim, Jung-Ho;Lee, Ok Joo;Sheikh, Faheem A.;Ju, Hyung Woo;Moon, Bo Mi;Park, Hyun Jung;Park, Chan Hum
    • Polymer(Korea)
    • /
    • v.38 no.2
    • /
    • pp.150-155
    • /
    • 2014
  • Polycaprolactone (PCL) is a synthetic biodegradable polymer with excellent mechanical properties. $TiO_2$ (titanium dioxide) has a hydrophilic, high density and excellent biocompatibility. In this work, we produced three-dimensional porous scaffolds with PCL and $TiO_2$ nanoparticles using a salt-leaching method. Physical properties of the scaffolds were analyzed by FE-SEM, FTIR, TGA and compressive strength. Interestingly, the addition of $TiO_2$ nanoparticles decreased the water absorption and swelling ratio of the porous scaffolds. However, the compressive strength was increased by $TiO_2$. CCK-8 assay, which is generally used for the analysis of cell growth, shows that $TiO_2$ nanoparticles have no cytotoxicity. Taken together, we suggest that the PLC/$TiO_2$-scaffold can be used for biomedical applications.