• Title/Summary/Keyword: Biomedical monitoring

Search Result 461, Processing Time 0.034 seconds

Ginsenosides Inhibit HMGB1-induced Inflammatory Responses in HUVECs and in Murine Polymicrobial Sepsis

  • Lee, Wonhwa;Ku, Sae-Kwang;Jeong, Tae Cheon;Lee, Sangkyu;Bae, Jong-Sup
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.10
    • /
    • pp.2955-2962
    • /
    • 2014
  • Asian ginseng is used as a treatment for cardiovascular diseases, ischemia, and cancers. High mobility group box 1 (HMGB1) protein acts as a late mediator of severe vascular inflammatory conditions. However, the effect of ginsenosides from Asian ginseng on HMGB1-induced inflammatory responses has not been studied. We addressed this question by monitoring the effects of ginsenoside treatment on lipopolysaccharide (LPS) and cecal ligation and puncture (CLP)-mediated release of HMGB1, and HMGB1-mediated regulation of proinflammatory responses. Ginsenoside treatment suppressed LPS-mediated release of HMGB1 and HMGB1-mediated cytoskeletal rearrangements. Ginsenosides also inhibited HMGB1-mediated inflammatory responses. In addition, ginsenosides inhibited the production of tumor necrosis factor-${\alpha}$ (TNF-${\alpha}$) and activation of protein kinase B (Akt), nuclear factor-${\kappa}B$ (NF-${\kappa}B$), and extracellular-regulated kinases (ERK) 1/2 by HMGB1. Ginsenosides also decreased CLP-induced release of HMGB1, production of interleukin (IL) $1{\beta}/6$, and mortality. These results suggested that ginsenosides may be potential therapeutic agents for treatment of vascular inflammatory diseases through inhibition of the HMGB1 signaling pathway.

Theoretical Analysis of Phase Detector Technique for the Measurement of Cell Membrane Capacitance During Exocytosis (세포외 분비시 막 캐패시턴스를 측정하기 위한 위상감지법(phase detector technique)의 이론적 분석.)

  • Cha, Eun-Jong;Goo, Yong-Sook;Lee, Tae-Soo
    • Progress in Medical Physics
    • /
    • v.3 no.2
    • /
    • pp.43-57
    • /
    • 1992
  • Phase detector techique provides a unique probe to membrane recycling phenomenon by enabling dynamic monitoring of cell membrane capacitance. However, it has inherent errors due to constant changes in measurement environments. The present study analyzed several error sources to develope application criteria of this technique. and the following was found based on a theoretical analysis. The initial phase angle has to be appropriately selected to minimize the error due to perturbation of access and membrane conductances. Excitation frequency is also important to determine the initial phase angle. However. deviation of the phase angle from a predetermined initial value during the measurement period does not affect capacitance estimation to a significant degree. Despite an appropriate initial phase selection an error in scaling factor is expected for a large increase in capacitance during exocytosis. which may be overcome by iteratively correcting the scaling factor over the measurement period. These results will provide a useful guideline in practical application of this technique.

  • PDF

The Development of Extravasation Detection Accessory System for the Preventive Contrast Media Extravasation in the Computed Tomography: A Preliminary Report (CT 검사에서 조영제의 혈관외유출 예방을 위한 EDA 시스템 개발의 예비 보고)

  • Kweon Dae-Cheol;Jeong Seok-Hee;Kim Tae-Hyung;Kim Jeong-Goo;Park Peom
    • Progress in Medical Physics
    • /
    • v.17 no.1
    • /
    • pp.32-39
    • /
    • 2006
  • To assess the ability of an extravasation detection accessory (EDA) system to detect clinically important extravascular injection of iodinated contrast material delivered with an automated power injector. Fifty patients referred for contrast material enhanced body computed tomography studied in a prospective, observation study in which the EDA system was used to identify and interrupt any injection associated with clinically Important extravasation. The presence or absence of extravasation was definitively established with multi-detector CT at the injection site (injection rate, $2.0{\sim}2.5$ mL/sec). There were two true positive, extravasation volumes $22{\sim}25$ mL. The EDA system had sensitivity in the detection of clinically important extravasation. The EDA system is easy to use, safe, and accurate In the monitoring of intravenous injections for extravasation, which may prove especially useful in CT applications.

  • PDF

Development of Estimation Methods of Skin Oxidation and Evaluation of Anti-Oxidative Effects of Genistein in Topical Formulations

  • Kim, Seong-Yeon;Na, Yeon-Joo;Kim, Dong-Ju;Kim, Yeong-Seok;Kim, Hyeong-Min;Hwang, Sung-Ha;Kwak, Ji-Yeon;Kuh, Hyo-Jeong;Lee, Jae-Hwi
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.16 no.3
    • /
    • pp.205-209
    • /
    • 2012
  • The objective of the present study was to establish the method of measurement of hydrogen peroxide and to estimate the anti-oxidative effect of genistein in the skin. UVB induced skin oxidation and anti-oxidative effect of genistein formulations were evaluated by determining levels of hydrogen peroxide. The mechanism involved in the determination of hydrogen peroxide is based on a color reaction between ferric ion ($Fe^{3+}$) and xylenol orange, often called FOX assay and subsequent monitoring of absorbance values of the reactant at 540 nm. The reaction was to some extent pH-dependent and detection sensitivity was greatest at pH 1.75. Genistein liposomal gel demonstrated better anti-oxidative effect with regard to lowering hydrogen peroxide levels elevated by UVB irradiation compared to genistein-suspended gel. A linear relationship has been observed between anti-oxidative effect of genistein and drug deposition in the skin tissue. Genistein liposomal gel resulting in the localization of the drug in the deeper skin led to improved anti-oxidative effect compared to genistein gel. The suggested method for evaluation of oxidation of the skin can be used as a tool to screen effective anti-oxidative agents and their delivery systems acting on the skin.

A Study on Safety, Performance and Clinical effectiveness Test Guideline of Versatile Ophthalmic Laser System (다목적 안과용 레이저 시스템 안전성 성능평가 및 임상적 유효성평가 가이드라인 수립을 위한 연구)

  • Kim, You Rim;Yu, Woo Jin;Park, Ho Joon;Jang, Won Seuk
    • Journal of Biomedical Engineering Research
    • /
    • v.40 no.6
    • /
    • pp.250-259
    • /
    • 2019
  • Ophthalmic Laser System is widely used in Selective Laser Trabeculoplasty of Open Angle Glaucoma and Ocular Hypertension. Versatile ophthalmic laser system is a medical device with technology that checks the condition of the treatment area by irradiating a continuous laser pulse on the treatment area, and monitoring the microbubble reaction caused by the temperature increase of the melanosome through the ultrasonic signal and the optical signal sensor. It performs selective laser treatment without damaging the photoreceptor by controlling the wavelength of the laser when microbubbles are detected. This study aims to suggest a guideline for evaluating safety, performance and clinical effectiveness of Versatile Ophthalmic Laser System in accordance with the growing technology. International Standards, Regulations, and Clinical Trial Protocols were investigated and analyzed for this study. As a result of this study, the safety, performance and clinical effectiveness test guideline for Versatile Ophthalmic Laser System were proposed. This guideline will ensure the safety and efficacy of Medical device, and furthermore it is expected to be able to promote the development of technology development by supporting a clinical trial plan.

Photopolymerization and Properties of PCL-Based Biodegradable Molecularly Imprinted Polymers (PCL 기반 생분해성 분자 날인 고분자의 광중합 및 물성)

  • Kim, Sun-Hui;Lee, Kyung-Soo;Kim, Yong-Hoon;Choi, Woo-Jin;Kim, Beom-Soo;Kim, Eung-Kook;Kim, Dae-Su
    • Polymer(Korea)
    • /
    • v.31 no.2
    • /
    • pp.153-159
    • /
    • 2007
  • Biodegradable molecularly imprinted polymers (MIPs) can be applied in the biomedical area of biosensors, drug delivery, etc. Therefore, in this study, biodegradable theophylline MIPs were synthesized via photopolymerization using a poly $(\varepsilon-caprolactone)$ (PCL) macromer as a cross-linker and their physical properties were investigated. The yield for the synthesis of the PCL macromer with terminal acrylate groups was ca. 78 mol%. The products were characterized by the combination of FT-IR and $^1H-NMR$ spectroscopic analyses. UV/Visible spectroscopic analysis for removing and rebinding theophylline was performed by monitoring the theophylline concentration in the solution. In vitro biodegradation tests of the theophylline MIPs performed in phosphate buffered saline (PBS) solution at $37^{\circ}C$ showed good biodegradability of the MIPs.

Diagnostic Method for the Detection of JC Polyomavirus Using Loop-mediated Isothermal Amplification (등온증폭법을 이용한 고감도 JC polyomaviruses 진단법 개발)

  • Cho, Kyu Bong
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.51 no.4
    • /
    • pp.414-419
    • /
    • 2019
  • JC polyomavirus (JCPyV) is a human pathogenic virus belonging to the family Polyomaviridae, a viral group containing dsDNA nucleic acid. A recent recommendation is to apply the presence of JCPyV as a fecal indicator for water contamination in environments like sewage, and techniques to monitor JCPyV in water are being proposed. To date, the conventional PCR system has been applied as a diagnostic method for detecting JCPyV. There is a need for a more rapid and sensitive JCPyV diagnostic detection method in clinical and environmental samples. In this study, we developed a loop-mediated isothermal amplification (LAMP) primer set for the detection of JCPyV. Our results indicate that the LAMP method using a specific primer set shows about 10-fold higher detection sensitivity than the conventional PCR system. The effectiveness of the LAMP method developed in this study has been validated by PCR product digestion using the HaeIII restriction enzyme. We, therefore, propose that the LAMP method using a specific primer set can be applied as a rapid and sensitive detection method for monitoring JCPyV in clinical and environmental samples.

Predicting lipoabdominoplasty complications with infrared thermography: a delta-R analysis

  • Resende, Patricia Rodrigues;Brioschi, Marcos Leal;Meneck, Franciele De;Neves, Eduardo Borba;Teixeira, Manoel Jacobsen
    • Archives of Plastic Surgery
    • /
    • v.48 no.5
    • /
    • pp.553-558
    • /
    • 2021
  • The diagnosis of the main complications resulting from lipoabdominoplasty has not yet been standardized. Infrared thermal imaging has been used to assess possible complications, such as necrosis and changes in micro- and macro-circulation, based on perforator mapping techniques, among others. The objective of this study was to present two clinical cases involving thermal imaging monitoring of the healing process of lipoabdominoplasty in the immediate postoperative evaluation and its preliminary results. Infrared thermography was performed 24 hours after the operation and on postoperative days 5, 25, and 27. In clinical case 1, it was found that the delta-R (∆TR)-defined as the difference in minimum temperature between the highest and lowest points in the SA3 region (caution suction area) following the classification established by Matarasso-was 0.4℃ at 24 hours after surgery and decreased to 0.1℃ on a postoperative day 5. There were no complications in this case. In contrast, in clinical case 2, the ∆TR was 1.7℃ at 24 hours after surgery (upon hospital discharge) and remained high, at 2.2℃, on postoperative day 5. A higher ∆TR was found in the second patient, who developed necrosis of the surgical wound. The ∆TR thermal index may be a new tool for predicting possible complications, complementing the clinical evaluation and therapeutic decision-making.

Radiolabeling of antibody-mimetic scaffold protein with 99mTc tricarbonyl precursor via hexahistidine (His6)-tag

  • Shim, Ha Eun;Kim, Do Hee;Lee, Chang Heon;Choi, Dae seong;Lee, Dong-Eun
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.5 no.1
    • /
    • pp.11-17
    • /
    • 2019
  • Recently, antibody-like scaffold proteins have received a great deal of interest in diagnosis and therapy applications because of their intrinsic features that are often required for tumor imaging and therapy. Intrinsic issues that are associated with therapeutic application of antibody-like scaffold proteins, particularly in cancer treatment, include an efficient and straightforward radiolabeling for understanding in vivo biodistribution and excretion route, and monitoring therapeutic responses. Herein, we report an efficient and straightforward method for radiolabeling of antibody-like scaffold proteins with the $[^{99m}Tc(OH_2)_3(CO)_3]^+$ ($^{99m}Tc$-tricarbonyl) by using a site-specific direct labeling method via hexahistidine-tag, which is a widely used for general purification of recombinant proteins with His-affinity chromatography. Repebody is a new class of antibody-like scaffold protein that consists of highly diverse leucine-rich repeat (LRR) modules. Although all possible biomedical applications with repebody are ongoing, it's in vivo biodistribution and excretion pathway has not yet been explored. In this study, hexahistidine ($His_6$)-tag bearing repebody (rEgH9) was labeled with [$^{99m}Tc$]-tricarbonyl. Repebody protein was radiolabeled with high radiolabeling efficiency (>90%) and radiolabeled compound was more than 99% pure after purification. These results clearly demonstrate that the present radiolabeling method will be useful molecular imaging study.

Development and validation of LC-MS/MS for bioanalysis of hydroxychloroquine in human whole blood

  • Park, Jung Youl;Song, Hyun Ho;Kwon, Young Ee;Kim, Seo Jin;Jang, Sukil;Joo, Seong Soo
    • Journal of Biomedical and Translational Research
    • /
    • v.19 no.4
    • /
    • pp.130-139
    • /
    • 2018
  • This study aimed to analyze a high-performance liquid chromatography (HPLC) separation using a pentafluorophenyl column of parent drug hydroxychloroquine (HCQ) and its active metabolite, desethylhydroxchloroquine (DHCQ) applying to determine bioequivalence of two different formulations administered to patients. A rapid, simple, sensitive and specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and validated for bioanalysis of HCQ and its metabolite DHCQ in human whole blood using deuterium derivative $hydroxychloroquine-D_4$ as an internal standard (IS). A triple-quadrupole mass spectrometer was operated using electrospray ionization in multiple reaction monitoring (MRM) mode. Sample preparation involves a two-step precipitation of protein techniques. The removed protein blood samples were chromatographed on a pentafluorophenyl (PFP) column ($50mm{\times}4.6mm$, $2.6{\mu}m$) with a mobile phase (ammonium formate solution containing dilute formic acid) in an isocratic mode at a flow rate of 0.45 mL/min. The standard curves were found to be linear in the range of 2 - 500 ng/mL for HCQ; 2 - 2,000 ng/mL for DHCQ in spite of lacking a highly sensitive MS spectrometry system. Results of intra- and inter-day precision and accuracy were within acceptable limits. A run time of 2.2 min for HCQ and 2.03 min for DHCQ in blood sample facilitated the analysis of more than 300 human whole blood samples per day. Taken together, we concluded that the assay developed herein represents a highly qualified technology for the quantification of HCQ in human whole blood for a parallel design bioequivalence study in a healthy male.