• Title/Summary/Keyword: Biomedical data

Search Result 2,237, Processing Time 0.029 seconds

Stiffness Analysis of External Fixation System with System Configuration Parameters (시스템 구성 인자를 고려한 외고정장치 시스템의 강성 해석)

  • Kim Yoon Hyuk;Lee Hyun Keun
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.531-536
    • /
    • 2004
  • In fracture treatment with external fixators, the inter-fragmentary movements at the fracture site affect the fracture healing process, and these movements are highly related to the stiffness of external fixation systems. Therefore, in order to provide the optimal fracture healing at the fracture site, it is essential to understand the relationship between the stiffness and the system configurations in external fixation system. In this study we investigated the influences of system configuration parameters on the stiffness in the finite element analysis of an external fixation system of a long bone. The system alignment, the geometric and the material non-linearity of the pin, the joint stiffness and the callus formation were considered in the finite element model. In the first, the system stiffness of the developed finite element model was compared with the experiment data for model validation. The consideration of the joint stiffness and nonlinearity of the model improved the system stiffness results. The joint stiffness, the non-alignment of the system decreased the system stiffness while the callus formation increased the system stiffness. The present results provided the biomechanical basis of rational guidelines for design improvements of external fixators and pre-op. planning to maximize the system stiffness in fracture surgery.

Blood Flow Simulation in Bifurcated Geometry of Abdominal and Iliac Arteries Based on CT Images (CT영상에 기반한 복부대동맥과 장골동맥 분기관 모델의 혈류유동 해석)

  • Hong Y. S.;Kim M. C.;Kang H. M.;Lee C. S.;Kim C. J.;Lee J. M.;Kim D. S.;Lee K.
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.497-503
    • /
    • 2004
  • Numerical simulation of blood flow has been conducted based on real vessel geometries generated front DICOM medical images of abdominal and iliac bifurcated arteries of a healthy man. A program was developed to read cross sectional images of the three dimensional arteries and smoothly extract boundary coordinates of vessels. Commercial programs were employed for mesh generation and flow simulation. Pressures, velocities, and flow distributions were found to lie within normal physiological ranges. Peak velocity measured in the iliac artery by ultrasound was 20% smaller than that obtained by simulation. The trend of velocity variation in a cardiac cycle was fairly similar between the simulation and the ultrasonic measurements. Simulation based on real vessel geometry of individual patient provides information on pressure, velocity, and its distribution in the diseased arteries or arteries to be surgically treated. The results of simulation may help surgeons to better understand hemodynamic status and surgical need of the patient by revealing variation of the hemodynamic parameters. Futhermore, they may serve as basic data for surgical treatment of arteries. This research is expected to develop to a program in the future that early diagnose atherosclerosis by showing distribution of a hemodynamic index closely related to atherosclerosis in arteries.

Analysis of the Micro-Structural and Mechanical Properties in Human Femoral Head Trabecular Bone with and without Osteoporosis (대퇴골두 해면골의 미세구조 특성과 기계적 특성의 분석)

  • Won Ye-Yeon;Baek Myong-Hyun;Cui WenQuan;Chun KeyoungJin;Kim Man Kyung
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.519-523
    • /
    • 2004
  • This study investigates micro-structural and mechanical properties of trabecular bone in human femoral head with and without osteoporosis using Micro-CT and finite element-model. 15 cored trabecular bone specimens with 20min of diameter were obtained from femoral heads with osteoporosis (T-score > -2.5 ) resected for total hip arthroplasty, and 5 specimens were removed from femoral head of cadavers, which has no history of musculoskeletal diseases. A high-resolution micro-CT system was used to scan each specimen to obtain histomorphometry indices. Based on obtained micro-images(pixel size=21.31㎛), a FE-model was created to determine mechanical property indices. While non-osteoporosis group had increases trabecular thickness, bone volume, bone volume fraction, degree of anisotropy and trabecular number compared with those of non-osteoporotic group, the non-osteoporotic group showed decreases in trabecular separation and structure model index. Regarding the mechanical property indices, reaction force, apparent stress and young's modulus were 1ower in osteoporotic group than in non-osteoporotic group. Our data shows salient deteriorations in trabecular micro-structural and mechanical properties in human femoral head with osteoporosis.

Grand Average in MEG and Crude Estimation of Anatomical Site (뇌자도에서 전체 평균과 이를 이용한 해부학적 위치 추정)

  • Kwon H.;Kim K.;Kim J. M.;Lee Y. H.;Park Y. K.
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.575-580
    • /
    • 2004
  • In this work, a method is presented to find an anatomical site of a current source crudely in a standard brain using grand average of MEG data. Minimum norm estimation algorithm and truncated singular value decomposition were applied to calculate the distributed sources that can reproduce the measured signals. Grand average over all subjects was obtained from the transformed signals, which would be detected in a standard sensor plane by the obtained distributed current sources. In the simulation study, it was shown that the localized dipole using the grand average is consistent with the mean location of localized dipoles of all subjects within several mm even with large inter-individual differences of sensor positions. This result suggests that the mean location of low level signal source can be estimated as a dipole source in grand average and it was confirmed in the localization of the current source of N100m. when the localized dipole is registered on a standard brain. This result also suggests that the activity region obtained from grand average can be crudely estimated on a standard brain using the source location of the N100m as a reference point.

Flow Visualization in the Branching Duct by Using Particle Imaging Velocimetry (입자영상유속계를 이용한 분기관내 유동가시화)

  • No, Hyeong-Un;Seo, Sang-Ho;Yu, Sang-Sin
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.1
    • /
    • pp.29-36
    • /
    • 1999
  • The objective of this study is to analyse the flow field in the branching duct by visualizing the flow phenomena using the PIV system. A bifurcation model is fabricated with transparent acrylic resin to visualize the whole flow field with the PIV system. Water was used as the working fluid and the conifer powder as the tracer particles. The single-frame and two-frame methods of the PIV system and 2-frame of the grey level correlation method are applied to obtain the velocity vectors from the images captured in the flow filed. The velocity distributions in a lid-driven cavity flow are compared with the so-called standard experimental data, which was obtained from by 4-frame method in order to validate experimental results of the PIV measurements. The flow patterns of a Newtonian fluid in a branching duct were successfully visualized by using the PIV system and the sub-pixel and the area interpolation method were used to obtain the final velocity vectors. The velocity vectors obtained from the PIV system are in good agreement with the numerical results of the 3-dimensional branch flow. The results of numerical analyses and the PIV experiments for the three-dimensional flows in the branch ing duct show the recirculation zone distal to the branching point and the sizes of the recirculation length and height of the tow different methods are in good agreement.

  • PDF

Design and Performance Evaluation of Small Size Counting and Imaging Gamma Probe System (소형 계수용 및 영상용 감마프로브 시스템의 설계와 성능평가)

  • Yang, Myo-Geun;Kwark, Cheol-Eun;Sim, yong-Geol;Kim, Hee-Joung;Choi, Yong;Chung, Jung-Key;Lee, Myung-Chul;Koh, Chang-Soon
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.3
    • /
    • pp.291-299
    • /
    • 1997
  • As a microimaging device detecting gamma rays emitted from small lesions or tumors during operation, the intraoperative surgical probe has been proposed and is now under development. We have designed a multipurpose portable gamma prove system and evaluated the performance both for the absolute counting purpose of residual radioactivities and for the localizing capability of gamma events using the NaI(Tl) crystal and two types of photomultiplier tubes(PMTs). Counting efficiencies in the range of routine clinical use of radiation dose were measured using the assembly of single channel PMTs and 0.5 inch thick NaI(Tl) crystal of 1 inch diameter. The positioning of gamma events for imaging purpose requires the multiple channel PMTs with appropriate positioning electronics. We have designed a simple and reliable positioning circuit based on the concept of modified Anger. In preliminary experiments using the multiple channel PMT of 3 inch diameter and the dim lighth source, we were able to trace and localize the correct position with reduced positioning error by the use of two multiplier/divider chipset and simplified peripherals. The energy resolutions for the counting gamma probe measured as full width at half maximum(FWHM) for Cs-137, F-18, Tc-99m were 12%, 13%, and 36%, respectively. The spatial resolution for the imaging gamma probe measured as FWHM for green LED was 2.9 mm. The results indicate that the currently developing probe is very promising and could be very useful for many applications in nuclear medicine. Future studies will include developing collimators, improving interface hardwares, and evaluating the system with clinical data.

  • PDF

Influence on Amputee Gait by the Ankle Joint Alignment (발목관절 조절각도가 절단환자의 보행에 미치는 영향)

  • Jang, Yun-Hui;Yang, Gil-Tae;Im, Song-Hak;Mun, Mu-Seong;Kim, Yeong-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.4
    • /
    • pp.403-416
    • /
    • 1998
  • Socket pressure distributions with gait analysis of a trnsfemoral and a transtibial prostheses were measured in order to assess an optimal socket fitting and function. Ankle joint was aligned by the neutral and the dorsi/plantar flexed positions. Compared to dorsi and plantar flexed positions of ankle joint, cadence and walking speed increased with the neutral ankle joint alignment. Other gait parameters were close to the normative data with the neutral ankle joint alignment. For the transfemoral amputee, dorsiflexed alignment of the ankle joint created high pressure on the lateral aspect of the socket, on the other hand, plantarflexed alignment resulted in increased pressure on the medial aspect of the socket. For the transtibial amputee, dorsiflexed alignment of the ankle resulted in high pressure on the antero-lateral aspect of the socket during mid-stance, but apltarflexion of the ankle joint showed slight increases in pressure at the same location in the socket. The present study clearly demonstarted that malalignment of a prosthesis results in localized increasesing pressure within the socket. Proper slignment of the prosthesis is required in order to acquire an appropriate socket-limb interface as well as the proper gait.

  • PDF

An Analysis of Consumer Emotion for Product Planning of Smart Clothing (스마트 의류 상품 기획을 위한 감성 효과 분석)

  • Cho, Hyun-Seung;Kim, Jung-Ho;Koo, Hye-Ran
    • Science of Emotion and Sensibility
    • /
    • v.17 no.3
    • /
    • pp.49-56
    • /
    • 2014
  • This study aims at providing basic data for product planning to design smart clothing and to develop applications, focusing on consumers by satisfying their emotions through analyzing emotional factors on smart clothing, comparing emotional differences between conventional clothing and it, reviewing changes of consumers' emotion by integrating the product and clothing and researching differences of preference and purchase intention between smart clothing and traditional one. As the results of the study, emotional factors for smart clothing were analyzed with total 6 including 'technical', 'comfort', 'aesthetic', 'modern', 'fun' and 'multiple' factors. Among them, except for 'comport', five emotional factors showed emotional factors between conventional sport-casual clothing and smart clothing. That is, emotional factors of 'technical', 'aesthetic', 'modern', 'fun' and 'multiple' were emphasized more in smart clothing than conventional ones, indicating that they should be considered in planning products of smart clothing. Though there was no significant difference of preference between smart clothing and conventional clothing, in case of comparison of averages, that of smart clothing was a little higher. For purchase intention, smart clothing was lower than the conventional clothing. So preference seems to be not directly related to consumers' immediate purchase. To make consumers' interests and preference to result in purchase, it is necessary to develop smart clothing with more various applications and to prepare commercializing strategies. As the results of the analysis on free-descriptive questionnaire survey, consumers were interested in development of smart clothing to help diet with functions including energy harvesting from body motion, calorification and perspiration, measurement of motion and calory consumption as well as health-care type smart clothing to measure heartbeat and ECG. Reflecting these requirements from the consumers, they should be utilized as guidance to develop smart clothing in the future.

Clostridium difficile Toxin A Inhibits Erythropoietin Receptor-Mediated Colonocyte Focal Adhesion Through Inactivation of Janus Kinase-2

  • Nam, Seung Taek;Seok, Heon;Kim, Dae Hong;Nam, Hyo Jung;Kang, Jin Ku;Eom, Jang Hyun;Lee, Min Bum;Kim, Sung Kuk;Park, Mi Jung;Chang, Jong Soo;Ha, Eun-Mi;Shong, Ko Eun;Hwang, Jae Sam;Kim, Ho
    • Journal of Microbiology and Biotechnology
    • /
    • v.22 no.12
    • /
    • pp.1629-1635
    • /
    • 2012
  • Previously, we demonstrated that the erythropoietin receptor (EpoR) is present on fibroblasts, where it regulates focal contact. Here, we assessed whether this action of EpoR is involved in the reduced cell adhesion observed in colonocytes exposed to Clostridium difficile toxin A. EpoR was present and functionally active in cells of the human colonic epithelial cell line HT29 and epithelial cells of human colon tissues. Toxin A significantly decreased activating phosphorylations of EpoR and its downstream signaling molecules JAK-2 (Janus kinase 2) and STAT5 (signal transducer and activator of transcription 5). In vitro kinase assays confirmed that toxin A inhibited JAK 2 kinase activity. Pharmacological inhibition of JAK2 (with AG490) abrogated activating phosphorylations of EpoR and also decreased focal contacts in association with inactivation of paxillin, an essential focal adhesion molecule. In addition, AG490 treatment significantly decreased expression of occludin (a tight junction molecule) and tight junction levels. Taken together, these data suggest that inhibition of JAK2 by toxin A in colonocytes causes inactivation of EpoR, thereby enhancing the inhibition of focal contact formation and loss of tight junctions known to be associated with the enzymatic activity of toxin A.

Oral health related quality of life according to firefighters' job characteristics (소방공무원의 업무요인에 따른 구강건강관련 삶의 질)

  • Hwang, Se-Hyun;Kim, Sung-Ae;Lee, Ji-Young;Ko, Hyo-Jin;Park, Jung-Hyun;Urm, Sang-Hwa;Yu, Byeng-Chul
    • Journal of Korean society of Dental Hygiene
    • /
    • v.15 no.2
    • /
    • pp.333-342
    • /
    • 2015
  • Objectives: The $1.8{\pm}1.5$purpose of the study was to investigate the oral health related quality of life according to work factors of firefighters in Korea. Methods: A self-reported questionnaire was completed by 270 firefighters in Changwon, Gimhae, and Ulsan from June 27 to July 24, 2011 after receiving informed consent. The questionnaire consisted of 5 questions of general characteristics of the subjects, 6 questions of job-related characteristics, and 14 questions of oral health related quality of life(OHIP-14). Data analysis was performed with reliability test, descriptive analysis, t-test, analysis of variance(ANOVA) and multiple regression analysis using SAS(version 9.2) program. Results: The score of oral health related quality of life in firefighters was $10.1{\pm}8.0$. The scores of subscale of the oral health quality of life were $2.4{\pm}1.5$ in physical pain, $1.8{\pm}1.5$ in psychological discomfort, $1.5{\pm}1.5$ in physical disability, $1.4{\pm}1.5$ in functional limitation, $1.3{\pm}1.4$ psychological disability, $0.9{\pm}1.3$ in handicap, and $0.7{\pm}1.3$ in social disability. The related factors of oral health quality of life in firefighters were rank(p=0.016) and the frequency of daily mobilization(p=0.029). Conclusions: Oral health related quality of life in firefighters was relatively in good condition. For the better oral health related quality of life in firefighters, it is important to establish the continuing oral health promotion program for those who have irregular job characteristics and job intensity.