Stiffness Analysis of External Fixation System with System Configuration Parameters

시스템 구성 인자를 고려한 외고정장치 시스템의 강성 해석

  • Kim Yoon Hyuk (School of Advanced Technology, Kyung Hee University) ;
  • Lee Hyun Keun (School of Advanced Technology, Kyung Hee University)
  • 김윤혁 (경희대학교 테크노공학대학) ;
  • 이현근 (경희대학교 테크노공학대학)
  • Published : 2004.12.01

Abstract

In fracture treatment with external fixators, the inter-fragmentary movements at the fracture site affect the fracture healing process, and these movements are highly related to the stiffness of external fixation systems. Therefore, in order to provide the optimal fracture healing at the fracture site, it is essential to understand the relationship between the stiffness and the system configurations in external fixation system. In this study we investigated the influences of system configuration parameters on the stiffness in the finite element analysis of an external fixation system of a long bone. The system alignment, the geometric and the material non-linearity of the pin, the joint stiffness and the callus formation were considered in the finite element model. In the first, the system stiffness of the developed finite element model was compared with the experiment data for model validation. The consideration of the joint stiffness and nonlinearity of the model improved the system stiffness results. The joint stiffness, the non-alignment of the system decreased the system stiffness while the callus formation increased the system stiffness. The present results provided the biomechanical basis of rational guidelines for design improvements of external fixators and pre-op. planning to maximize the system stiffness in fracture surgery.

외고정장치를 이용한 골절 치료에서, 골절 부위에서의 절골편간 운동은 골절의 치유과정에 다양한 영향을 미친다고 알려져 있고, 이 미세 운동은 외고정장치-절골편 시스템의 강성과 밀접한 관련이 있다. 그렇기 때문에 최적의 골절 치유 과정을 부여하기 위하여 외고정장치 시스템의 구성 인자와 강성과의 연관성에 대한 이해가 필요하다. 본 연구에서는 장골 골절의 외고정술에 대한 유한요소 해석에서 외고정장치 시스템의 구성인자가 시스템 강성에 미치는 영향을 조사하였다. 이를 위하여, 시스템 정렬, 재료 비선형성, 조인트 유연성 및 가골형성 등을 해석 인자로 선정하였다. 개발된 유한요소 모델은 실험 결과와 유사한 시스템 강성을 나타내었고, 조인트 유연성 및 재료 비선형성의 고려는 시스템 강성 결과를 더욱 정확하게 반영하였다. 시스템 비정렬상태, 조인트 유연성 및 재료 비선형성은 시스템 강성의 감소를, 그리고 골절 부위의 가골형성은 시스템 강성의 증가를 나타내었다. 본 연구 결과는 외고정술시 시스템 강성을 증가시키기 위한 프레임 구성이나 기구 설계 등의 도구로 사용될 수 있을 것으로 기대된다.

Keywords

References

  1. E.Y.S. Chao and H.T. Aro, 'Biomechanics and biology of external fixation', InL Coombs R, Green SA, Sarmiento A (Eds), External Fixation & Fundamental Bracing. London, Orthotext. Ch. 11, pp. 67-95, 1989
  2. D. Paley and K. Tetsworth, 'Mechanical axis deviation of the lower limbs; preoperative planning of uniapical deformities of the tibia and femur', Clinical Orthopedics, Vol. 280, pp. 48-64,1992
  3. E. Y .S. Chao and T.J. Hein, 'Mechanical performance of the standard Orthofix external fixator', Orthopedics, Vol.11, pp. 1057-1069, 1988
  4. E.L. Egger, F. Gottsauner-Wolf, J. Palmer, H.T. Aro andE.Y .S. Chao, 'Effects of axial dynamization on bone healing', Journalof Trauma, Vol. 34, No.2, pp.185-192, 1993 https://doi.org/10.1097/00005373-199302000-00001
  5. P. Augat, J. Burger, S. Schorlemmer, T. Henke, M. Peraus and L. Claes, 'Shear moνement at the fracture site delays healing in a diaphyseal fracture model', Journal of Orthopaedic Research, Vol. 21, pp. 1011-1017, 2003
  6. B. Fleming, D. Paley, T. Kristiansen and M. Pope, 'A biomechanical analysis of the Ilizarov external fixator', Clinical Orthopedics,No.241 pp. 95-105, 1989
  7. H. Stein, R. Mosheiff, F. Baumgart, R. Frigg, S.M. Perren and J. Cordey, 'The hybrid ring tubular external fixator: a biomechanical study', Clinical Biomechanics, Vol. 12, No. 4, pp. 259-266,1997 https://doi.org/10.1016/S0268-0033(97)00006-5
  8. T.N. Gardner and M. Evans, 'Relative stiffness, transverse displacement and dynamization in comparable external fixators', Clinical Biomechanics, Vol. 7, No.4, pp. 231-239, 1992 https://doi.org/10.1016/S0268-0033(92)90006-P
  9. K.N. An, R.A. Kasman and E.Y .S. Chao, 'Theoretical analysis of fracture healing monitoring with external fixators', Eng Med. Vol. 17, No.1, pp. 11-15,1988 https://doi.org/10.1243/EMED_JOUR_1988_017_006_02
  10. J.K. Oh, D.Y.Jung and I.S. Kim, 'The biomechanics of hybrid external fixator - The effect of periarticular half pin on frame stiffness', Journal of Korean fracture Society, Vol. 15, pp. 114-122, 2002
  11. Y.H. Kim, N. Inoue and E.Y.S. Chao, 'Kinematic simulation of fracture reduction and bone deformity correction under unilateral external fixation', Journal of Biomechanics., Vol. 35, pp. 1047-1058, 2002
  12. M. Matsuura, N. Inoue, D. Chen, J. Lin, and E.Y.S. Chao, ’Mechanical Performance of Serrated Joint in Comparison with Ball-and-SocketJoint in Unilateral External Fixator Design', Johns Hopkins Orthopedic Biomechanics Internal Report, 2000
  13. E.Y.S. Chao, R.A. Kasman and K.N. An, 'Rigidity and stress analyses of external fracture fixation devices: A theoretical approach', Journal of Biomechanics., Vol. 15, pp. 971-983, 1982
  14. Military hand book 'Metallic materials and elements for aerospace vehicle structures' AMSC N/A, pp. 214-241, 1998
  15. L. Claes and P. Augat, 'Models in fracture healing: report from the Reisensburg workshop September 1999', Journal of Orthopedic Trauma,、Vol.14, No. 6, pp.440-441, 2000 https://doi.org/10.1097/00005131-200008000-00011
  16. G.. Zhang, 'Geometric and material nonlinearity in tensioned wires of an external fixator', Clinical Biomechanics, Vol. 19, No.5, pp. 513-518, 2004 https://doi.org/10.1016/j.clinbiomech.2004.01.009
  17. M.A. Watson, 'Yielding of the clamped-wire system in the Ilizarov external fixator', Proc Inst Mech Eng., Vol. 217, pp.367-374, 2003