• Title/Summary/Keyword: Biological Signal Monitoring

Search Result 88, Processing Time 0.027 seconds

Alarm System for Sudden Infant Death using Bio-Signals (생체 신호를 활용한 영아 돌연사 알람 시스템)

  • Yun, Su-Jeong;Lin, Chi-Ho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.4
    • /
    • pp.197-202
    • /
    • 2016
  • In this paper, a danger signal to tell caregivers when a dangerous situation occurs, the bio-signal analysis in infants to prevent sudden infant death sudden infant death propose a monitoring system. The Sudden infant death (SID) refers to a healthy baby is unexplained deaths between birth year in the month. Sudden infant death proposed monitoring system is composed of a processor unit and the monitoring and alarm part for processing part and the biological signal sensing biological signals. Using the PPG sensor to sense the bio-signal and the processor unit the signal obtained through the sensor by removing the motion artifact was able to alarm and monitoring the parent.The proposed system will send the alarm to monitoring and alerting caregivers if the risk situation by analyzing the heart rate of the infant. With the actual implementation of the system to evaluate the performance of the monitoring system.

Real Time Implementittion of Time Varying Nonstationary Signal Identifier and Its Application to Muscle Fatigue Monitoring (비정상 시변 신호 인식기의 실시간 구현 및 근피로도 측정에의 응용)

  • Lee, Jin;Lee, Young-Seock;Kim, Sung-Hwan
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.3
    • /
    • pp.317-324
    • /
    • 1995
  • A need exists for the accurate identification of time series models having time varying parameters, as is important in the case of real time identification of nonstationary EMG signal. Thls paper describes real time identification and muscle fatigue monitoring method of nonstationary EMG signal. The method is composed of the efficient identifier which estimates the autoregressive parameters of nonstationary EMG signal model, and its real time implementation by using T805 parallel processing computer. The method is verified through experiment with real EMG signals which are obtained from surface electrode. As a result, the proposed method provides a new approach for real time Implementation of muscle fatigue monitoring and the execution time is 0.894ms/sample for 1024Hz EMG signal.

  • PDF

Multi-access Monitoring System for Biological Signal Collection (생체신호수집을 위한 다중접속 모니터링 시스템)

  • Kim, Tae-Woong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.1
    • /
    • pp.145-148
    • /
    • 2020
  • Wearable computing is growing rapidly as research on body area communication network using wireless sensor network technology is actively conducted. In particular, there is an increasing interest in smart clothing measuring unrestrained and insensitive bio signals, and research is being actively conducted. However, research on smart clothing is mainly based on 1: 1 wireless communication. In this paper, we propose a multi-access monitoring system that can measure bio-signals by multiple users wearing smart clothing. The proposed system consists of wireless access device, multiple access control server and monitoring system. It also provides a service that allows multiple users to monitor and measure bio signals at the same time.

Development of Humidity Sensor Based on Ceramic/Metal Halide Composite Films for Non-Contact Biological Signal Monitoring Applications (비접촉 생체신호 모니터링 응용을 위한 세라믹/메탈 할라이드 복합막 기반 습도센서 개발)

  • Park, Tae-Ung;Kim, Ik-Soo;Kim, Min-Ji;Park, Chulhwan;Seo, Eui-kyoung;Oh, Jong-Min
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.4
    • /
    • pp.412-417
    • /
    • 2022
  • Capacitive-type humidity sensors with a high sensitivity and fast response/recovery times have attracted a great attention in non-contact respiration biological signal monitoring applications. However, complicated fabrication processes involving high-temperature heat treatment for the hygroscopic film is essential in the conventional ceramic-based humidity sensors. In this study, a non-toxic ceramic/metal halide (BaTiO3(BT)/NaCl) humidity sensor was prepared at room temperature using a solvent-free aerosol deposition process (AD) without any additional process. Currently prepared BT/NaCl humidity sensor shows an excellent sensitivity (245 pF/RH%) and superior response/recovery times (3s/4s) due to the NaCl ionization effect resulting in an immense interfacial polarization. Furthermore, the non-contact respiration signal variation using the BT/NaCl sensor was determined to be over 700% by maintaining the distance of 20 cm between the individual and the sensor. Through the AD-fabricated sensor in this study, we expect to develop a non-contact biological signal monitoring system that can be applied to various fields such as respiratory disease detection and management, infant respiratory signal observation, and touchless skin moisture sensing button.

On-line Measurement of Buffer Capacity of a Fermentation medium and Estimation of Organic Aicd Production (발효배지의 완충용량의 온라인 측정 및 유기산 생산 추정)

  • Hur, Won;Jung, Yoon-Keun
    • KSBB Journal
    • /
    • v.13 no.4
    • /
    • pp.461-467
    • /
    • 1998
  • A fermentation system was supplemented with a device for the measurement of the durations of alkali pump feeding for automatic pH control and an A/D convertor for precise monitoring of pH value by computer. A software program was developed to measure buffer capacities from the pH signal and the pH control signal during fermentation. By measuring the buffer capacity on-line, levels of acetic acid were estimated by a software sensor using pH signal in a fermentation process of E.coli growing in a minimal medium. The measured values of acetic acid showed correlation to those of estimated by the software sensor. Lacitic acid production was also successfully estimated by the values of buffer capacities measured on-line.

  • PDF

Light Modulation based on PPG Signal Processing for Biomedical Signal Monitoring Device (생체 정보 감시 장치를 위한 광변조 기법의 PPG 신호처리)

  • Lee, Han-Wook;Lee, Ju-Won;Jeong, Won-Geun;Kim, Seong-Hoo;Lee, Gun-Ki
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.6
    • /
    • pp.503-509
    • /
    • 2009
  • The development of technology has led to ubiquitous health care service, which enables many patients to receive medical services anytime and anywhere. For the ubiquitous health care environment, real-time measurement of biomedical signals is very important, and the medical instruments must be small and portable or wearable. So, such devices have been developed to measure biomedical signals. In this study, we develop the biomedical monitoring device which is sensing the PPG signal, one of the useful signal in the field of ubiquitous healthcare. We design a watch-like biomedical signal monitoring system without a finger probe to prevent the user's inconvenience. This system obtains the PPG from the radial artery using a sensor in the wrist band. But, new device developed in this paper is easy to get the motion artifacts. So, we proposed new algorithm removing the motion artifacts from the PPG signal. The method detects motion artifacts by changing the degree of brightness of the light source. If the brightness of the light source is reduced, the PPG pulses will disappear. When the PPG pulses have disappeared completely, the remaining signal is not the signal that results from the changing blood flow. We believe that this signal is the motion artifact and call it the noise reference signal. The motion artifacts are removed by subtracting the noise reference signal from the input signal. We apply this algorithm to the system, so we can stabilize the biomedical monitoring system we designed.

Implementation and Evaluation of Chair-type ECG Monitoring System using Unconstraint Electrode (무구속 전극을 이용한 의자형 심전도 모니터링 시스템의 구현 및 평가)

  • Noh, Yun-Hong;Jeong, Do-Un
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.16 no.2
    • /
    • pp.56-62
    • /
    • 2015
  • In this study, we implemented an unconstraint ECG monitoring system on a chair. Nowadays, modern people spend most of their time sitting on the chair. Therefore, it is necessary to have an unconstraint ECG monitoring system that can be used for a long time. The implemented system can perform measurement even with clothes on and it has great advantage on motion artifacts. A pair of unconstraint electrodes are placed on the back of the chair. Amplifier and filters are designed to remove motion artifacts, The baseline noise and power line noise are filtered and very low level of bio-signal is amplified to give a final measurement. Control unit and wireless transmission unit are implemented. Analog signal is converted into digital signal and transmits biological signal to the PC and the smart phone. Therefore continuous ECG monitoring in daily life is made possible. A comparison experiment between Ag / AgCl electrode and unconstraint electrode is conducted to evaluate the performance of the implemented system. As a result, we confirm our unconstraint system can be used for daily life ECG monitoring.

A Study on The Davelopement of Electronic Fetal Heart Rate Monitoring System Using Personal Computer (개인용 컴퓨터를 이용한 전자 태아심음 감시장치의 개발에 관한 연구)

  • 정지환;김선일
    • Journal of Biomedical Engineering Research
    • /
    • v.12 no.3
    • /
    • pp.209-214
    • /
    • 1991
  • Digital fetal monitoring system based on the personal computer combined with the digital signal processing (DSP) board was implemented. The DSP board acquires and digitally processes ultra- sound fetal Doppler signal for digital signal conditioning, rectification, low -pass filtering, autocorrealtion function calculation and its peak detection. The personal computer interfaced with the DSP board is in charge of graphic display, hardcopy, data transmission and on -line analysis of fetal heart rate change including on - line warning system, base -line estmation, acceleration, deceleration and variability. It is one of the most suitable situation to apply the DSP chip for siganl conditioning, digital filtering of ultrasound fetal Dopier signal and fetal heart rate estimation using autocorrelation technique .

  • PDF

Design and Implementation of Biological Signal Measurement Algorithm for Remote Patient Monitoring based on IoT (IoT기반 원격환자모니터링을 위한 생체신호 측정 알고리즘 설계 및 구현)

  • Jung, Ae-Ran;You, Yong-Min;Lee, Sang-Joon
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.8 no.6
    • /
    • pp.957-966
    • /
    • 2018
  • Recently, the demand for remote patient monitoring based on IoT has been increased due to aging population and an increase in single-person household. A non-contact biological signal measurement system using multiple IR-UWB radars for remote patient monitoring is proposed in this paper. To reduce error signals, a multilayer Subtraction algorithm is applied because when the background subtraction algorithm was applied to the biological signal processing, errors occurred such as voltage noise and staircase phenomenon. Therefore, a multilayer background subtraction algorithm is applied to reduce error occurrence. The multilayer background subtraction algorithm extracts the signal by calculating the amount of change between the previous clutter and the current clutter. In this study, the SVD algorithm is used. We applied the improved multilayer background subtraction algorithm to biological signal measurement and computed the respiration rate through Fast Fourier Transform (FFT). To verify the proposed system using IR-UWB radars and multilayer background subtraction algorithm, the respiration rate was measured. The validity of this study was verified by obtaining a precision of 97.36% as a result of a control experiment with Neulog's attachment type breathing apparatus. The implemented algorithm improves the inconvenience of the existing contact wearable method.

Evaluation of CDMA Network Based Wireless 3 Channel ECG Monitoring System (CDMA망 기반 3채널 심전도 모니터링 시스템의 평가)

  • Hong, Joo-Hyun;Cha, Eun-Jong;Lee, Tae-Soo
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.4
    • /
    • pp.295-301
    • /
    • 2008
  • A wireless 3 channel ECG monitoring system was developed so that it could monitor the health and movement state during subject's daily life. The developed system consists of a wireless biomedical signal acquisition device, a personal healthcare server, and a remote medical server. Three experiments were performed to evaluate the accuracy, reliability and operability, applicability during daily life of the developed device. First, ECG signals were measured using the developed device and commercial reference device during sitting and marking time and compared to verify the accuracy of R-R intervals. Second, the reliable data transmission to remote server was verified on two types of simulated emergency event using patient simulator. Third, during five types of motion in daily life, the accuracy of data transmission to remote server using CDMA network was verified on two types of event occurring. By acquiring and comparing subject's biomedical signal and motion signal, the accuracy, reliability and operability, applicability during daily life of the developed device were verified. In addition, PDA-phone based wireless system enabled subject to be monitored without any constraints. Therefore, the developed system is expected to be applicable for monitoring the aged and chronic diseased people and giving first-aid in emergency.