• Title/Summary/Keyword: Bioelectrical impedance analysis (BIA)

Search Result 49, Processing Time 0.033 seconds

Implementation of Multiple Frequency Bioelectrical Impedance Analysis System for Body Composition Analysis (신체 성분 분석을 위한 다 주파수 생체전기 임피던스 분석 시스템 구현)

  • Kim, Seong-Cheol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.11
    • /
    • pp.5403-5408
    • /
    • 2012
  • In this paper, we introduce the multiple frequency bio-electrical impedance analysis method for body composition analysis. And then we implement the multiple frequency bio-electrical impedance analysis system. Overall system consists of: multiple frequency alternating current signal generator contained alternating current signal, phase signal detector, voltage signal detector, micro controller, in-out device(key-pad LCD), conductivity electrodes, system power. We explain the architecture of the system and required theory to implement the system. In order to investigate the clinical significance of the body composition data, compare to the data measured by the expert body composition analyzer which provide high reproduction and precision. Finally, experimental results which are the correlation between the measured data show the very high reproduction performance of the body composition analysis in the proposed system.

Factors Associated with Sarcopenia among Hemodialysis Patients (혈액투석환자의 근감소증 관련요인)

  • Shin, Hye Yun;Min, Hye Sook
    • Journal of Korean Critical Care Nursing
    • /
    • v.15 no.1
    • /
    • pp.24-34
    • /
    • 2022
  • Purpose : This descriptive survey aims to identify the prevalence of factors associated with sarcopenia among hemodialysis patients. Methods : The study subjects were 137 patients with chronic kidney failure undergoing hemodialysis in three artificial kidney centers in B and Y cities. Data were collected from August 1 to September 30, 2020, using the SARC-F (Strength, Assistant walking, Rising from a chair, Climbing stairs, Falls) questionnaire, Mini Nutritional Assessment-Short Form (MNA-SF), International Physical Activity Questionnaire (IPAQ-SF), Bioelectrical Impedance Analysis (BIA), and a grip dynamometer. The collected data were analyzed using t-tests, crossover analysis, and logistic regression using the IBM SPSS 23 program. Results : The prevalence of sarcopenia among hemodialysis patients, determined using the SARC-F questionnaire, was 16.1%. The associated factors of sarcopenia among hemodialysis patients were found to be gender (OR=6.44, p =.002), age (OR=1.07, p =.015), nutritional status (OR=10.37, p =.027), and albumin level (OR=0.10, p =.014). These findings are supported by an explanatory power of 46.3% (p =.597). Conclusion : The identified risk factors for sarcopenia in hemodialysis patients were; sex, age, nutritional status, and albumin level. The findings of this study can serve as clinical evidence for the development of an intervention program for preventing and managing sarcopenia in patients undergoing hemodialysis.

Low-Molecular Collagen Peptide Supplementation and Body Fat Mass in Adults Aged ≥ 50 Years: A Randomized, Double-Blind, Placebo-Controlled Trial

  • Jeongbin Park;Minji Kim;Hyeri Shin;Hyejin Ahn;Yoo Kyoung Park
    • Clinical Nutrition Research
    • /
    • v.12 no.4
    • /
    • pp.245-256
    • /
    • 2023
  • A randomized, double-blind, placebo-controlled trial was conducted to confirm whether collagen peptide supplementation for 12 week has a beneficial effect on body fat control in older adults at a daily physical activity level. Participants were assigned to either the collagen group (15 g/day of collagen peptide) or the placebo group (placebo drink). Body composition was measured by bioelectrical impedance analysis (BIA) and dual-energy X-ray absorptiometry (DEXA). In total, 74 participants (collagen group, n = 37; placebo group, n = 37) were included in the final analysis. The collagen group showed a significant reduction in total body fat mass compared with the placebo group, as evidenced by both BIA (p = 0.021) and DEXA (p = 0.041) measurements. Body fat mass and percent body fat of the whole body and trunk reduced at 12 weeks compared with baseline only in the collagen group (whole body: body fat mass, p = 0.002; percent body fat, p = 0.002; trunk: body fat mass, p = 0.001; percent body fat, p = 0.000). Total fat mass change (%) (collagen group, -0.49 ± 3.39; placebo group, 2.23 ± 4.20) showed a significant difference between the two groups (p = 0.041). Physical activity, dietary intake, and biochemical parameters showed no significant difference between the groups. The results confirmed that collagen peptide supplementation had a beneficial effect on body fat reduction in older adults aged ≥ 50 years with daily physical activity level. Thus, collagen peptide supplementation has a positive effect on age-related changes.

The Cut Off Values of Body Fat Percentage for Diagnose Obese among Selected Number of Preschool Children in Yangsan (우리나라 양산지역 학동전기 아동에서 비만 진단을 위한 체지방률의 절단값)

  • Jeong, Min-Jeong;Kim, Ki-Bong
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.24 no.2
    • /
    • pp.99-111
    • /
    • 2010
  • Objectives The objectives of this study were to evaluate the correlations between the indices of obesity and percentage body fat by bioelectrical impedance analysis(BIA). Also, this study was designed to define the cut off values of percentage body fat by BIA which would represent BMI and degree of obesity in order to detect overweight and obesity in preschool children. Methods The height and weight of 683 children aged four to six years old were measured. Also, percentages of body fat were measured by BIA. Results There were high correlations between the boy's body fat percentages and degree of obesity(r=790). Also, there were high correlations between the girl's body fatpercentages and BMI(r=778). The cut off values of body fat percentage, which would correspond to those of BMI percentiles, were calculated by ROC curve analysis. To classify as an overweight, the correspondent cut off values of body fat percentage were 19.55% in boys and 22.35% in girls. For obesity, the cut off values were 28.80% in boys and 27.60% in girls. The cut off values of body fat percentage, which would correspond to degree of obesity were calculated by ROC curve analysis. To classify as an overweight, the correspondent cut off values of body fat percentage were 19.75% in boys and 22.35% in girls. For obesity, the cut off values were 29.05% in boys and 28.75% in girls. Conclusions According to the BMI criteria by the Korean pediatrics society in 2007, the most appropriate cut off values of body fat percentage in for four to six years old children were follows; for boys, 19.55% considered as overweight, and 28.80% as obese while for girls, 22.35% considered as overweight and 27.60% as obese. According to suggested degree of obesity criteria, the most appropriate cut off values of body fat percentage in for four to six old children were were follows; For boys, 19.75% was considered as overweight, and 29.05% as obesity. For girls, 22.35% was considered as overweight, and 28.75% as obese.

A Patient with Liver Fire Flaming Upward and Metabolic Syndrome Improved by Korean Medicine: A Case Report (대사증후군이 동반된 간화상염 변증 환자에 대한 한의정신요법 병행 한의치료 증례보고)

  • Jun-Hee, Cho;Jung-Hwa, Lim;Bo-Kyung, Kim
    • Journal of Oriental Neuropsychiatry
    • /
    • v.33 no.4
    • /
    • pp.485-495
    • /
    • 2022
  • The purpose of this study is to report a case of a patient with pattern identification of liver fire flaming upward and metabolic syndrome improved by Korean medicine. The patient felt completely lost. She was treated for headache, insomnia, and metabolic syndrome with Korean medicine and psychotherapy. Pittsburgh Sleep Quality Index (PSQI), Insomnia Severity Index (ISI), Pattern Identification Tool for Insomnia (PIT-Insomnia), Minnesota multiphasic personality inventory-2 (MMPI-2), and bioelectrical impedance analysis (BIA) were used for assessment. During treatment for six months, the patient stopped taking headache pills. Her blood pressure was stabilized. Her body weight, body fat, body mass index (BMI), and visceral fat decreased significantly. The sum of ISI, PSQI, PIT-insomnia also decreased significantly. Her Ego strength increased in the MMPI-2 supplementary scale. We assume that Korean medicine treatment through acupuncture, herbal medicine, and psychotherapy is effective in treating pattern identification of liver fire flaming upward and metabolic syndrome.

Body Composition Factor Comparisons of the Intracellular Fluid(ICW), Extracellular Fluid(ECW) and Cell Membrane at Acupuncture Points and Non-Acupuncture Points by Inducing Multiple Ionic Changes (생체이온 변화 유발 후 경혈과 비경혈에서의 생체 구조 성분 분석 및 비교를 통한 경혈 특이성 고찰)

  • Kim, Soo-Byeong;Chung, Kyung-Yul;Jeon, Mi-Seon;Shin, Tae-Min;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • v.31 no.2
    • /
    • pp.66-78
    • /
    • 2014
  • Objectives : The specificity of acupuncture point has been a highly controversial subject. Existing researches said that ion-distribution differences are observed on the acupuncture point. This study was conducted under the assumption that multiple ionic changes induced by muscle fatigue would be different between the acupuncture point with non-acupuncture point. Methods : To induce the identical fatigue, twenty subjects performed the knee extension/flexion exercise using the Biodex System 3. ST32 and ST33 as well as adjacent non-acupuncture points were selected. We measured blood lactate and analyzed the median frequency(MF) and peak torque. To obtain the information on the extracellular fluid(ECW), intracellular fluid(ICW) and cell membrane indirectly, we used the multi-frequency bioelectrical impedance analysis(MF-BIA) method. Results : MF, peak torque and blood lactate level of all measurement sites were gradually returned to normal. Re resistance of ST32 had a stronger response, but a non-acupuncture point adjacent to ST33 had a larger response up to 20 minutes post exercise. Ri resistances were similar for both acupoints and non-acupoints. The $C_m$ capacitance of ST32 had a stronger response after inducing fatigue, but ST33 had a smaller response than a non-acupuncture point adjacent to it. Conclusions : In comparison with before and after inducing fatigue, the specificity of acupuncture points was not clearly observed. Hence, we concluded that the body composition factors extraction method had the limitation as a method of finding the specificity of acupuncture points by inducing fatigue.

Development of the PDA Based Mobile System for Body Fat Measurement and Diagnosis Using Bioelectrical Impedance Method (체임피던스 방법을 이용한 PDA 기반의 휴대용 체지방 측정 및 진단 시스템 개발)

  • 권세윤;이상민;김재환;우지환;김인영;이형기;방석원;김선일
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.1
    • /
    • pp.21-26
    • /
    • 2004
  • Recently, many people want to know their state of health, such as a body fat rate, anywhere and anytime. The Personal Digital Assistance(PDA) is the portable wireless apparatus that has become widely popular. There are many application areas of the IDA to be in mobile care devices. In this study, we developed the PDA based body fat measurement system, composed of a cradle type measurement module and a WindowCE operated software module, a regression equation for predicting lean body mass (LBM). Sixty-three weight-stable subjects (53 men, 10 women) aged 20∼32yr participated in this study. A regression model, LBM = (0.0005*Height2 - 0.0160*Impedance + 0.3920*Weight - 0.0684*Age - 5.8141*Sex + 25.984, was found. The correlation coefficient( r) of body fat rate between developed system and HTM1000plus(BionetTM) was 0.928. HTM1000plus is a commercially available and approved by KFDA. These results indicated that developed system is reliable for estimation of body fat rate. Although developed system is the PDA based miniaturized, it shows good performance comparing with other commercial product.

Study on Muscle Circumference Among Groups Divided by Body Mass Index(BMI) (Body Mass Index(BMI) 분류에 따른 그룹들 간 근육둘레비율의 상관성 연구)

  • Kim, Dong-Gun;Cha, Yun-Yeop;Park, Won-Hyung
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.19 no.4
    • /
    • pp.1099-1103
    • /
    • 2005
  • This study aims to confirm the importance of behavior habit and exercise, especially leg exercise in obese. Out of 889 people, We divided Group A 50 (BMI<18.5), Group B 210 $(18.5{\leq}BMl<23)$, Group C 202 $(23{\leq}BMI<25)$, Group D212 $(25{\leq}BMI<30)$ and Group 1215 (30

Correlation between Measured Resting Energy Expenditure and Predicted Basal Energy Expenditure in Female College Students (여대생을 대상으로 한 실측 휴식대사량과 예측 기초대사량의 상관관계에 관한 연구)

  • Chang, Un-Jae;Lee, Kyeong-Ryeong
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.34 no.2
    • /
    • pp.196-201
    • /
    • 2005
  • The aim of this study was to confirm the validity of predictive equations for the calculation of basal energy expenditure (BEE). One hundred twenty female college students were participated in this study. The resting energy expenditure (REE) was measured by indirect calorimetry for 30 minutes following an 12 hour overnight fasting. Among the available equations for predict BEE, Harris-Benedict, WHO/FAO/UNU and Cunningham methods were selected. Body composition was estimated by bioelectrical impedance analysis (BIA) for the equation of predicted BEE. The mean of measured REE was 1257.2$\pm$147.9 kcal/day, while the predicted value by Harris-Benedict, WHO/FAO/UNU and Cunningham were 1373.3$\pm$45.4 kcal/day, 1290.0$\pm$61.7 kcal/day and 1187.6$\pm$49.2 kcal/day, respectively. The Cunningham equation was more closed to measured values than Harris-Benedict and WHO/FAO/UNU equation by the correlation coefficient. Comparing Pearson's correlation coefficients, fat-free mass (FFM), body surface area (BSA) and body weight were higher than others such as height, body mass index (BMI), fat and fat%. The FFM's correlation coefficient was the highest as 0.74. Thus, the conclusion of this study suggested that the main determinant of BEE was FFM, and we derived a prediction equation as follows: BEE=-569.86+48.27 (FFM).