• 제목/요약/키워드: Biodentine

검색결과 42건 처리시간 0.023초

Push-out bond strength and marginal adaptation of apical plugs with bioactive endodontic cements in simulated immature teeth

  • Maria Aparecida Barbosa de Sa;Eduardo Nunes ;Alberto Nogueira da Gama Antunes ;Manoel Brito Junior ;Martinho Campolina Rebello Horta ;Rodrigo Rodrigues Amaral;Stephen Cohen ;Frank Ferreira Silveira
    • Restorative Dentistry and Endodontics
    • /
    • 제46권4호
    • /
    • pp.53.1-53.11
    • /
    • 2021
  • Objectives: This study evaluates the bond strength and marginal adaptation of mineral trioxide aggregate (MTA) Repair HP and Biodentine used as apical plugs; MTA was used as reference material for comparison. Materials and Methods: A total of 30 single-rooted teeth with standardized, artificially created open apices were randomly divided into 3 groups (n = 10 per group), according to the material used to form 6-mm-thick apical plugs: group 1 (MTA Repair HP); group 2 (Biodentine); and group 3 (white MTA). Subsequently, the specimens were transversely sectioned to obtain 2 (cervical and apical) 2.5-mm-thick slices per root. Epoxy resin replicas were observed under a scanning electron microscope to measure the gap size at the material/dentin interface (the largest and smaller gaps were recorded for each replica). The bond strength of the investigated materials to dentin was determined using the push-out test. The variable bond strengths and gap sizes were evaluated independently at the apical and cervical root dentin slices. Data were analyzed using descriptive and analytic statistics. Results: The comparison between the groups regarding the variables' bond strengths and gap sizes showed no statistical difference (p > 0.05) except for a single difference in the smallest gap at the cervical root dentin slice, which was higher in group 3 than in group 1 (p < 0.05). Conclusions: The bond strength and marginal adaptation to root canal walls of MTA HP and Biodentine cement were comparable to white MTA.

분광분석법을 이용한 수종 MTA의 치관변색 평가 (Spectrophotometric Analysis of Crown Discoloration Induced by Various MTA Based Materials)

  • 임유란;최남기;김재환;김선미
    • 대한소아치과학회지
    • /
    • 제44권1호
    • /
    • pp.28-37
    • /
    • 2017
  • Mineral trioxide aggreagate는 치수 치료제로서 많이 사용되고 있는 재료중 하나이다. 그 중 가장 널리 쓰이고 있는 Proroot white $MTA^{(R)}$는 치아 변색을 일으킨다는 단점이 있다. 이번 연구에서는 MTA 기반 재료들인 Proroot $wMTA^{(R)}$, $Biodentine^{(R)}$, $Endocem^{(R)}$, $RetroMTA^{(R)}$를 치수강에 각각 채워넣어 시간에 따른 치경부의 변색을 비교하고자 하였다. 교정적인 이유로 발치된 75개의 소구치를 사용하여 무작위로 4개의 실험군(n = 60)과 한 개의 대조군(n = 15)으로 나누었다. 치아는 CEJ 하방 2 mm로 수평절단 하였다. 각각의 재료들을 제조사의 지시에 따라 준비한 후 치수강에 채워넣고 입구를 레진을 이용하여 봉인하였다. 치아 색조 측정은 국제조명위원회(Commission International de I'Eclairage, CIE)의 CIE $L^*a^*b^*$ system을 사용하였다. 색조는 분광 광도계를 사용하여 재료를 넣기 전, 재료를 넣고 1일, 1주, 2주, 4주, 8주, 12주, 16주 후로 총 8번 측정하였다. 이원 변량 분산분석(Two way repeated ANOVA)을 사용하여 시간에 따른 CIE $L^*$, $a^*$, $b^*$${\Delta}E$값을 비교 평가하였고 실험군과 대조군과의 통계적 유의성과 상호관계는 본페로니 검정으로 사후 검정하여 p 값이 0.05이하일 때 통계학적으로 유의하다고 간주하였다. Proroot $wMTA^{(R)}$는 시간에 따라 계속적인 $L^*$값의 감소를 보였고, $Endocem^{(R)}$은 재료를 넣은 직 후 육안으로 인지 불가능한 약간의 회색조 변색을 보였으며, $Biodentine^{(R)}$$RetroMTA^{(R)}$는 상대적으로 다른 재료보다 색 안정성을 보였다. 결론적으로, 방사선 불투과성 물질로서 산화 비스무스가 포함된 Proroot $wMTA^{(R)}$$Endocem^{(R)}$은 치관 변색을 보인 반면, 방사선 불투과성 물질로서 산화 지르코늄이 포함된 $Biodentine^{(R)}$$RetroMTA^{(R)}$는 시간에 따른 유의한 색 변화를 보이지 않았다.

Tricalcium Silicate-Based 치수복조재에 대한 수 종 수복재의 전단결합강도 비교 (Comparison of Shear Bond Strength of Different Restorative Materials to Tricalcium Silicate-Based Pulp Capping Materials)

  • 정화경;이난영;이상호
    • 대한소아치과학회지
    • /
    • 제44권2호
    • /
    • pp.200-209
    • /
    • 2017
  • 본 연구의 목적은 Tricalcium silicate를 기반으로 한 3종의 치수복조재(Theracal $LC^{TM}$, $Biodentine^{TM}$, $ProRoot^{TM}$ white MTA)와 임상에서 통상적으로 사용되는 수복재인 복합레진, 레진강화형 글래스아이오노머 시멘트, 그리고 전통적인 글래스아이오노머 시멘트 간의 전단결합강도를 비교 평가하는 것이다. 이를 위해 중심구를 가진 아크릴 레진 블록 90개를 제작하고 각각 30개씩 3종의 치수복조재로 중심구 안에 채운 다음, 다시 무작위로 10개씩 하위 군을 나누어 치수복조재 상방에 복합레진, 레진강화형 글래스아이오노머 시멘트, 전통적인 글래스아이오노머 시멘트를 적용하여 총 9개 군으로 이루어진 시편을 제작하였다. Universal testing machine을 이용해 전단결합강도를 측정한 뒤, 입체현미경을 사용해 파절양상을 분석하였다. 연구 결과, Theracal $LC^{TM}$-복합레진 군이 가장 높은 전단결합강도를, Theracal $LC^{TM}$-전통적인 글래스아이오노머 시멘트 군이 가장 낮은 전단결합강도를 나타냈다. 복합레진이 수복재로 선택된 군들이 다른 수복재 군에 비해 높은 전단결합강도를 보였다. 전통적인 글래스아이오노머 시멘트가 수복재인 경우 $Biodentine^{TM}$이 다른 치수복 조재 군들에 비해 높은 전단결합강도를 나타냈다.

치수재혈관화 술식에서 다양한 상아질 접착제가 치아 변색과 칼슘 실리케이트 시멘트의 밀폐 효과에 미치는 영향에 대한 실험실적 연구 (An in Vitro Study of the Effects of Different Dentin Bonding Agents on the Prevention of Tooth Discoloration and the Sealing Ability of Calcium Silicate-Based Cement in Regenerative Endodontic Procedures)

  • 한지은;김기민;이제식
    • 대한소아치과학회지
    • /
    • 제50권3호
    • /
    • pp.277-291
    • /
    • 2023
  • 본 연구는 치수 재혈관화 과정 중 상아질 접착제 도포 유무 및 종류가 치아 변색과 미세 누출에 미치는 영향을 평가하고자 하였다. 시편은 사람의 발거된 소구치 120개로 제작하였으며, 상아질 접착제 종류에 따라 다음과 같이 분류하였다. Group I. No bonding; Group II. One-Step; Group III. Clearfil SE Bond; Group IV. Single Bond Universal. 각 그룹은 칼슘 규산염계 시멘트인 Endocem MTA® Premixed Regular와 Biodentine의 사용에 따라 Subgroup a와 Subgroup b로 나뉘어 총 8개의 그룹으로 분류되었다. 치관변색 평가를 위해 초진(S0), 항생제 도포 1주(S1), 2주(S2), 4주 경과(S3)와 칼슘 규산염계 시멘트 적용 2주 경과(S4) 각 시점에서 사진을 촬영해 CIE L*a*b*를 측정하였다. 모든 시편은 2% 메틸렌 블루 용액에 침적 후 30배율로 관찰하여 미세누출을 평가하였다. 상아질 접착제 도포는 치관 변색을 감소시켰고, Biodentine은 상아질 접착제의 도포 유무 및 종류와 상관없이 최소한의 변색을 보였다. 또한 상아질 접착제 도포는 미세 누출을 증가시키지 않았다.

Effects of calcium silicate cements on neuronal conductivity

  • Derya Deniz-Sungur;Mehmet Ali Onur;Esin Akbay;Gamze Tan;Fugen Dagli-Comert;Taner Cem Sayin
    • Restorative Dentistry and Endodontics
    • /
    • 제47권2호
    • /
    • pp.18.1-18.9
    • /
    • 2022
  • Objectives: This study evaluated alterations in neuronal conductivity related to calcium silicate cements (CSCs) by investigating compound action potentials (cAPs) in rat sciatic nerves. Materials and Methods: Sciatic nerves were placed in a Tyrode bath and cAPs were recorded before, during, and after the application of test materials for 60-minute control, application, and recovery measurements, respectively. Freshly prepared ProRoot MTA, MTA Angelus, Biodentine, Endosequence RRM-Putty, BioAggregate, and RetroMTA were directly applied onto the nerves. Biopac LabPro version 3.7 was used to record and analyze cAPs. The data were statistically analyzed. Results: None of the CSCs totally blocked cAPs. RetroMTA, Biodentine, and MTA Angelus caused no significant alteration in cAPs (p > 0.05). Significantly lower cAPs were observed in recovery measurements for BioAggregate than in the control condition (p < 0.05). ProRoot MTA significantly but transiently reduced cAPs in the application period compared to the control period (p < 0.05). Endosequence RRM-Putty significantly reduced cAPs. Conclusions: Various CSCs may alter cAPs to some extent, but none of the CSCs irreversibly blocked them. The usage of fast-setting CSCs during apexification or regeneration of immature teeth seems safer than slow-setting CSCs due to their more favorable neuronal effects.

How image-processing parameters can influence the assessment of dental materials using micro-CT

  • Torres, Fernanda Ferrari Esteves;Jacobs, Reinhilde;EzEldeen, Mostafa;de Faria-Vasconcelos, Karla;Guerreiro-Tanomaru, Juliane Maria;dos Santos, Bernardo Camargo;Tanomaru-Filho, Mario
    • Imaging Science in Dentistry
    • /
    • 제50권2호
    • /
    • pp.161-168
    • /
    • 2020
  • Purpose: The aim of this study was to evaluate the influence of voxel size and different post-processing algorithms on the analysis of dental materials using micro-computed tomography (micro-CT). Materials and Methods: Root-end cavities were prepared in extracted maxillary premolars, filled with mineral trioxide aggregate (MTA), Biodentine, and Intermediate Restorative Material (IRM), and scanned using micro-CT. The volume and porosity of materials were evaluated and compared using voxel sizes of 5, 10, and 20 ㎛, as well as different software tools(post-processing algorithms). The CTAn or MeVisLab/Materialise 3-matic software package was used to perform volume and morphological analyses, and the CTAn or MeVisLab/Amira software was used to evaluate porosity. Data were analyzed using 1-way ANOVA and the Tukey test(P<0.05). Results: Using MeVisLab/Materialise 3-matic, a consistent tendency was observed for volume to increase at larger voxel sizes. CTAn showed higher volumes for MTA and IRM at 20 ㎛. Using CTAn, porosity values decreased as voxel size increased, with statistically significant differences for all materials. MeVisLab/Amira showed a difference for MTA and IRM at 5 ㎛, and for Biodentine at 20 ㎛. Significant differences in volume and porosity were observed in all software packages for Biodentine across all voxel sizes. Conclusion: Some differences in volume and porosity were found according to voxel size, image-processing software, and the radiopacity of the material. Consistent protocols are needed for research evaluating dental materials.

치수복조재와 최종수복재에 따른 대구치 부분치수절단술의 비교 (Comparison of Partial Pulpotomy in Permanent Molars Using Different Pulp Capping Agents and Restoration Materials)

  • 이지미;이난영;이상호;지명관
    • 대한소아치과학회지
    • /
    • 제47권2호
    • /
    • pp.148-156
    • /
    • 2020
  • 이 연구의 목적은 우식에 의해 치수가 노출된 영구대구치에서 Biodentine™(BD)과 RetroMTA®(RMTA)의 치수복조재 및 stainless steel crown(SSC)와 composite resin(CR)의 최종수복재를 적용하여 치료한 부분치수절단술 증례들의 임상 및 방사선학적 비교 평가를 통해 각 치수복조재 및 최종수복재가 치료 결과에 미치는 영향을 알아보는 것이다. 영구대구치의 상아질의 우식으로 진단되어 부분치수절단술을 받은 소아 및 청소년을 대상으로 경과관찰 기간이 1년 이상인 증례를 선정하여 임상적 평가 및 방사선학적 평가를 통해 치료의 성공률을 평가하였으며 각 성공률에 대해 Fisher's exact test로 통계 분석하였다. 치수복조재에 대한 평가에서 BD이 RMTA에 비해 더 높은 치료 성공률을 보였다(p < 0.05). 치수복조재의 종류와 관계없이 최종수복재를 평가하였을 때 SSC으로 수복했을 때 CR으로 수복한 경우에 비해 더 높은 성공률을 보였다(p < 0.05). 치수복조재로 RMTA를 사용하고 최종수복재로 CR을 사용한 경우에 가장 낮은 성공률을 보였다(p < 0.05).

완전 탈구된 미성숙 영구치의 치수재생치료 증례 보고 (Outcome of Regenerative Endodontic Treatment for an Avulsed Immature Permanent Tooth: A Case Report)

  • 박나경;송지현
    • 대한소아치과학회지
    • /
    • 제45권2호
    • /
    • pp.250-256
    • /
    • 2018
  • 치아의 완전 탈구는 치조골에서 치아가 완전히 이탈된 것으로 정의되며, 결과적으로 신경혈관 공급의 중단을 야기하는 가장 심각한 치과적 손상 중 하나로 알려져 있다. 완전 탈구는 조직 허혈(tissue ischemia)을 야기하며, 이는 치수 괴사를 초래할 수 있다. 치근단형성술(apexification)은 치수 괴사로 진단된 미성숙 영구치에서 치근단 장벽을 유도하는 전통적인 치료 방법이다. 하지만 치근단형성술로는 치근 길이 및 두께의 증가를 포함하는 치근 발육을 얻을 수 없다. 본 증례는 완전 탈구되어 재식된 이후 치수 괴사로 진단된 치아를 가진 5세 환자에서 ciprofloxacin, metronidazole, cefaclor 및 CollaTape과 Biodentine을 이용하여 시행된 치수재생치료(regenerative endodontic treatment)의 임상적 및 방사선학적 결과를 다루고 있다.

Micro-computed tomographic evaluation of the flow and filling ability of endodontic materials using different test models

  • Torres, Fernanda Ferrari Esteves;Guerreiro-Tanomaru, Juliane Maria;Chavez-Andrade, Gisselle Moraima;Pinto, Jader Camilo;Berbert, Fabio Luiz Camargo Villela;Tanomaru-Filho, Mario
    • Restorative Dentistry and Endodontics
    • /
    • 제45권2호
    • /
    • pp.11.1-11.9
    • /
    • 2020
  • Objectives: This study compared the flow and filling of several retrograde filling materials using new different test models. Materials and Methods: Glass plates were manufactured with a central cavity and 4 grooves in the horizontal and vertical directions. Grooves with the dimensions used in the previous study (1 × 1 × 2 mm; length, width, and height respectively) were compared with grooves measuring 1 × 1 × 1 and 1 × 2 × 1 mm. Biodentine, intermediate restorative material (IRM), and mineral trioxide aggregate (MTA) were evaluated. Each material was placed in the central cavity, and then another glass plate and a metal weight were placed over the cement. The glass plate/material set was scanned using micro-computed tomography. Flow was calculated by linear measurements in the grooves. Central filling was calculated in the central cavity (㎣) and lateral filling was measured up to 2 mm from the central cavity. Results: Biodentine presented the least flow and better filling than IRM when evaluated in the 1 × 1 × 2 model. In a comparison of the test models, MTA had the most flow in the 1 × 1 × 2 model. All materials had lower lateral filling when the 1 × 1 × 2 model was used. Conclusions: Flow and filling were affected by the size of the test models. Higher grooves and materials with greater flow resulted in lower filling capacity. The test model measuring 1 × 1 × 2 mm showed a better ability to differentiate among the materials.

Biomineralization of three calcium silicate-based cements after implantation in rat subcutaneous tissue

  • Ranjdar Mahmood Talabani;Balkees Taha Garib;Reza Masaeli;Kavosh Zandsalimi;Farinaz Ketabat
    • Restorative Dentistry and Endodontics
    • /
    • 제46권1호
    • /
    • pp.1.1-1.13
    • /
    • 2021
  • Objectives: The aim of this study was to evaluate the dystrophic mineralization deposits from 3 calcium silicate-based cements (Micro-Mega mineral trioxide aggregate [MM-MTA], Biodentine [BD], and EndoSequence Root Repair Material [ESRRM] putty) over time after subcutaneous implantation into rats. Materials and Methods: Forty-five silicon tubes containing the tested materials and 15 empty tubes (serving as a control group) were subcutaneously implanted into the backs of 15 Wistar rats. At 1, 4, and 8 weeks after implantation, the animals were euthanized (n = 5 animals/group), and the silicon tubes were removed with the surrounding tissues. Histopathological tissue sections were stained with von Kossa stain to assess mineralization. Scanning electron microscopy and energy-dispersive X-ray spectroscopy (SEM/EDX) were also used to assess the chemical components of the surface precipitates deposited on the implant and the pattern of calcium and phosphorus distribution at the material-tissue interface. The calcium-to-phosphorus ratios were compared using the non-parametric Kruskal-Wallis test at a significance level of 5%. Results: The von Kossa staining showed that both BD and ESRRM putty induced mineralization starting at week 1; this mineralization increased further until the end of the study. In contrast, MM-MTA induced dystrophic calcification later, from 4 weeks onward. SEM/EDX showed no statistically significant differences in the calcium- and phosphorus-rich areas among the 3 materials at any time point (p > 0.05). Conclusions: After subcutaneous implantation, biomineralization of the 3-calcium silicate-based cements started early and increased over time, and all 3 tested cements generated calcium- and phosphorus-containing surface precipitates.