• Title/Summary/Keyword: Biocompatible

Search Result 442, Processing Time 0.031 seconds

Bioactive characteristics of an implant surface coated with a pH buffering agent: an in vitro study

  • Pae, Hyung-Chul;Kim, Su-Kyoung;Park, Jin-Young;Song, Young Woo;Cha, Jae-Kook;Paik, Jeong-Won;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.49 no.6
    • /
    • pp.366-381
    • /
    • 2019
  • Purpose: The purpose of this study was to evaluate the effectiveness of conventional sandblasted, large-grit, acid-etched (SLA) surface coated with a pH buffering solution based on surface wettability, blood protein adhesion, osteoblast affinity, and platelet adhesion and activation. Methods: Titanium discs and implants with conventional SLA surface (SA), SLA surface in an aqueous calcium chloride solution (CA), and SLA surface with a pH buffering agent (SOI) were prepared. The wetting velocity was measured by the number of threads wetted by blood over an interval of time. Serum albumin adsorption was tested using the bicinchoninic acid assay and by measuring fluorescence intensity. Osteoblast activity assays (osteoblast adhesion, proliferation, differentiation, mineralization, and migration) were also performed, and platelet adhesion and activation assays were conducted. Results: In both the wetting velocity test and the serum albumin adsorption assay, the SOI surface displayed a significantly higher wetting velocity than the SA surface (P=0.000 and P=0.000, respectively). In the osteoblast adhesion, proliferation, differentiation, and mineralization tests, the mean values for SOI were all higher than those for SA and CA. On the osteoblast migration, platelet adhesion, and activation tests, SOI also showed significantly higher values than SA (P=0.040, P=0.000, and P=0.000, respectively). Conclusions: SOI exhibited higher hydrophilicity and affinity for proteins, cells, and platelets than SA. Within the limits of this study, it may be concluded that coating an implant with a pH buffering agent can induce the attachment of platelets, proteins, and cells to the implant surface. Further studies should be conducted to directly compare SOI with other conventional surfaces with regard to its safety and effectiveness in clinical settings.

Artificial Vision Project by Micro-Bio Technologies

  • Kim Sung June;Jung Hum;Yu Young Suk;Yu Hyeong Gon;Cho Dong il;Lee Byeong Ho;Ku Yong Sook;Kim Eun Mi;Seo Jong Mo;Kim Hyo kyum;Kim Eui tae;Paik Seung June;Yoon Il Young
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2002.04a
    • /
    • pp.51-78
    • /
    • 2002
  • A number of research groups worldwide are studying electronic implants that can be mounted on retinal optic nerve/visual cortex to restore vision of patients suffering from retinal degeneration. The implants consist of a neural interface made of biocompatible materials, one or more integrated circuits for stimuli generation, a camera, an image processor, and a telemetric channel. The realization of these classes of neural prosthetic devices is largely due to the explosive development of micro- and nano-electronics technologies in the late $20^{th}$ century and biotechnologies more recently. Animal experiments showed promise and some human experiments are in progress to indicate that recognition of images can be obtained and improved over time. We, at NBS-ERC of SNU, have started our own retinal implant project in 2000. We have selected polyimide as the biomaterial for an epi-retinal stimulator. In-vitro and in-vivo biocompatibility studies have been performed on the electrode arrays. We have obtained good affinity to retinal pigment epithelial cells and no harmful effect. The implant also showed very good stability and safety in rabbit eye for 12 weeks. We have also demonstrated that through proper stimulation of inner retina, meaning vision can be obtained.

  • PDF

Efficient Delivery of Toxoid Antigens using Micro/Nano-carriers (마이크로/나노-운반체를 이용한 톡소이드 항원의 효과적인 전달 방법)

  • Park, Ga-Young;Ahn, Gna;Lee, Se Hee;Kim, Sang Bum;Kim, Yang-Hoon;Ahn, Ji-Young
    • Journal of Life Science
    • /
    • v.28 no.4
    • /
    • pp.496-507
    • /
    • 2018
  • Immunization has been performed for centuries and is generally accepted as a sustainable method of controlling bacteria, viruses, and mediated and infectious diseases. Despite many studies having been performed on animal subjects to demonstrate the importance of toxin immunity, the use of toxoid vaccines in humans and animals has been limited for a long time. Recently, the development of the toxoid antigen delivery system has been facilitated using novel nano-medicinal technology. The micro/nano-carrier has been used to improve vaccination coverage as well as reduce vaccine costs. A micro/nano-carrier is a micro/nano-sized material that delivers immune cargo, including recombinant or peptide toxoid antigens. These toxoid antigens are either encapsulated in the interior or displayed on the surface of micro/nano-carriers as a way to protect them from the cellular machinery. In particular, the combination of toxoid antigens and micro/nano-carriers can induce phagocytosis through the specific interactions between GCs and macrophages; thus, the toxoid antigens can be delivered easily into the macrophages. This paper reviews recent achievements of micro/nano-carriers in the field of vaccine delivery systems such as microbial ghost cells (GCs, Bacterial ghost cells and Yeast ghost cells), gene-manipulated outer membrane vesicles (OMVs) and biocompatible, polymer-based nanoparticles (NPs, NP-Carrier and NP-Cage). Finally, this review shows various aspects in terms of the hosts' immune responses.

HeLa Cell Culture on Nanoimprinted Patterns Using Conducting Polymer (전도성 고분자 나노임프린트 패턴 상의 HeLa 세포 배양)

  • Ahn, Junhyoung;Park, Kyungsook;Lee, Suok;Jung, Sanghee;Lim, Hyungjun;Shin, Yong-Beom;Lee, JaeJong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.1
    • /
    • pp.63-67
    • /
    • 2017
  • In bioscience and biotechnology, the research of fundamental life mechanisms and their diseases caused by insufficiency is important. The study of a whole organism is difficult and sometimes impossible because of DNA, RNA, proteins, cellular organelles, various cells, and organs. Cell cultures can provide a simple method for researching cellular mechanisms and conditions, both in terms of physiological performance, and in response to chemical stimulation. According to conventional cell culture methodology, the flat surface is used with surface treatments for cell adhesion on the surface. Micro- and nanoscale patterns have been developed with chemical and biochemical modifications for cell immobilization. In this study, HeLa cell culture on nanostructures patterns was studied, including the 300 nm line and 150 nm pillar structures, using nanoimprint lithography and pyrrole as a biocompatible conducting polymer.

Studies on the Graft Polymerization of Polyethyleneglycol Monomethacrylate onto Chitosan and Drug(Vitamin B12) Permeation Behavior (키토산과 폴리에틸렌글리콜 모노메타크릴레이트의 그라프트중합과 약물(Vitamin B12)방출에 관한 연구)

  • Chung, Joo-Eun;Chung, Byung-Ok;Chang, Byung-Kwon;Choi, Kyu-Suk
    • Applied Chemistry for Engineering
    • /
    • v.5 no.3
    • /
    • pp.524-536
    • /
    • 1994
  • Chitosan is known to be a good biocompatible natural polymer. Polyethyleneglycol monomethacrylates(PEGM) were grafted onto chitosan and their reaction conditions and properties of the graft polymers obtained were estimated. Using ceric ammonium nitrate(CAN) as the initiator, the optimum condition for graft polymerization was determined amount of the initiator and monomer concentrations and reaction time. Grafting yields such as total conversion, the percentage of grafting and the efficiency of grafting were calculated and examined the optimum reaction condition for high grafting yields. The percentage of grafting and total conversion were maximum at condition that the concentration of initiator was $4{\sim}5{\times}10^{-3}M$, the concentration of monomer was 0.5~0.6M, the reaction time was 2~3 hours and the reaction temperature was about $40^{\circ}C$. Thermal characteristics, solubility for chitosan solvents and inherent viscosity of synthesized graft copolymers were investigated. In high initiator concentration, characteristics of chitosan were greatly diminshed. In case of inherent viscosities, chitosan-g-PE-90 was 2.81 dl/g, chitosan-g-PE-200, 3.01dl/g and chitosan-g-PE-350, 4.93dl/g. And a tendency of viscosity increase depending on the length of ethylene oxide residue was confirmed. Degree of swelling, tensile strength, elongation of membrane prepared from graft copolymers were determined. Properties of graft copolymers were affected by percentage of grafting and length of ethylene oxides residue in polyethylene glycol monomethacrylates. Tensile strength, elongation and degree of swelling of graft copolymers were remarkably improved than chitosan. As percentage of grafting increased, the amount of drug permeation was also increased.

  • PDF

The Effects of Cesium, Strontium and Cobalt on Cell Toxicity in the 2D and 3D Cell Culture Platforms (단층 및 입체 세포배양환경에서 세슘, 스트론튬 및 코발트가 세포 독성에 미치는 영향 분석)

  • Kim, Gi Yong;Kang, Sung-Min;Jang, Sung-Chan;Huh, Yun Suk;Roh, Changhyun
    • Korean Journal of Environmental Biology
    • /
    • v.34 no.2
    • /
    • pp.107-115
    • /
    • 2016
  • Currently, there are 442 operating nuclear power plants in the world, and 62 more are under construction. According to this reasoning, the treatment of radioactive waste is important to prevent the environmental ecosystem including humans, animals, and plants. Especially, a leakage of radioactive waste causes not only regional problem but also serious global one. In this study, we demonstrate the effect of radioisotopes (e.g., cesium, strontium, and cobalt) on a 3D culture cell. To develop the 3D cell culture system, we used a 96-well-culture plate with biocompatible agarose hydrogel. Using this method, we can perform the 3D cell culture system with three different cell lines such as HeLa, HepG2, and COS-7. In addition, we conducted a cell viability test in the presence of radioisotopes. Interestingly, the 3D morphological cells showed 42% higher cell viability than those on the 2D against cesium. This result indicates that the 3D platform provides cells morphological and physiological characteristic similar to in vivo grown tissues. Moreover, it overcomes the limitation of conventional cell culture system that can't reflect in vivo systems. Finally, we believe that the proposed approach can be applied a new strategy for simple high-throughput screening and accurate evaluation of metal toxicity assay.

The study on Comparison Evaluation of Shear Bond Strength of Co-Cr Based Alloy using for Porcelain Fused Metal (도재용착주조관용 Co-Cr계 비귀금속 합금의 전단결합강도 비교평가에 관한 연구)

  • Kim, Hee-Jin;Kim, Bu-Sob
    • Journal of Technologic Dentistry
    • /
    • v.32 no.3
    • /
    • pp.195-207
    • /
    • 2010
  • Purpose: The purpose of this study was to observe the microstructural changes of surface in the specimens, performing the shear bond strength testing. The currently most used non-precious alloys are nickel-chromium based alloys with or without beryllium. However, their biocompatibility has been questioned concerning possible damages to the health of the patient and professionals involved in the fabrication of prosthesis caused by long exposure to Ni and Be. An option to nickel-chromium alloys is the cobalt-chromium alloy, an alternative that does not sacrifice the physical properties of the metal porcelain systems. Studies in the animals substantially show that the cobalt-chromium alloys are relatively well tolerated, being therefore more biocompatible than the nickel-chromium alloys. Methods: Non-addition Be to nickel-chromium based alloy(Bellabond plus) and cobalt-chromium alloy which has been widely used(Wirobond C) fused with ZEO light porcelain classified control group and cobalt-chromium alloy which is developing alloy of Alphadent company in Korea(Alphadent alloy) fused with ZEO light porcelain classified experimental group. The specimens of $4mm{\times}4mm{\times}0.5mm$ were prepared as-cast and as-opaque to cast body to analyze the mechanical characteristic change, the microstructure of alloy surface. The phase change was used to observe through XRD analysis and OM/SEM was used to observe the surface of specimens as-cast and as-opaque to cast body. Chemical formation of their elements was measured with EDS. Then hardness was measured with Micro Vicker's hardness tester. Shear bond strength test thirty specimens of $10mm{\times}10mm{\times}2mm$ was prepared, veneered, 3mm high and 3mm in diameter, over the alloy specimens. The shear bond strength test was performed in a universal testing machine(UTM) with a cross head speed of 0.5mm/min. Ultimate shear bond strength data were analyzed with one-way ANOVA and the Scheffe's test (P<0.05). Within the limits of this study, the following conclusions were drawn: The X-ray diffraction analysis results for the as-cast and as-opaque specimens showed that the major relative intensity of Bellabond plus alloy were changed smaller than Wirobond C and Alphadent Co-Cr based alloys. Results: Microstructural analysis results for the opaque specimens showed all the alloys increased carbides and precipitation(PPT). Alphadent Co-Cr based alloy showed the carbides of lamellar type. The Vickers hardness results for the opaque specimens showed Wirobond C and Alphadent Co-Cr based alloys were increaser than before ascast, but Bellabond plus alloy relatively decreased. The mean shear bond strengths (MPa) were: 33.11 for Wirobond C/ZEO light; 25.00 for Alphadent Co-Cr alloy/ZEO light; 18.02 for Bellabond plus/ZEO light. Conclusion: The mean shear bond strengths for Co-Cr and Ni-Cr based alloy were significantly different. But the all groups showed metal-metal oxide modes in shear bond strengths test at the interface.

Full-mouth rehabilitation with pressed ceramic technique using provisional restorations (Pressed ceramic technique을 이용하여 제작되는 완전 도재관 완전 구강 회복 증례)

  • Roh, Hyun-Sik;Woo, Yi-Hyung;Pae, Ahran
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.1
    • /
    • pp.47-51
    • /
    • 2013
  • With the introduction of dental implants, restoration of missing teeth with conventional fixed or removable partial dentures is being replaced with implants. Especially, with young patients, not only longevity but also esthetic factors need to be considered. Implant restorations provide long-term success functionally but, esthetic complications such as, marginal exposure due to gingival recession, loss of the papilla and dark color of metal abutments may occur. Recently, zirconia restorations with CAD/CAM technology provide functional, biocompatible and esthetic restorations possible. All-ceramic restorations using the pressed ceramic technique show better fracture toughness values than those of the conventional porcelain veneering technique. Pressed ceramic technique creates the veneer design in wax and the lost wax technique is used to create the restoration. The final contour of the restoration may be controlled during wax-up. A 22-year old female patient was restored with dental implants and zirconia restorations using the pressed ceramic technique presenting short-term but optimistic prognosis.

Effects of Mineral Trioxide Aggregate on the Proliferation and Differentiation of Human Dental Pulp Stromal Cells from Permanent and Deciduous Teeth (Mineral trioxide aggregate가 유치 및 영구치의 치수기질세포 증식 및 분화에 미치는 영향)

  • Kim, Seunghye;Jeon, Mijeong;Shin, Dong Min;Lee, Jae Ho;Song, Je Seon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.40 no.3
    • /
    • pp.185-193
    • /
    • 2013
  • Mineral trioxide aggregate (MTA) has recently been used as a pulpotomy medicament for primary molars. The aim of this study was to evaluate and compare the proliferation and differentiation potential of dental pulp stromal cells of permanent teeth and deciduous teeth cultured on MTA-coated surface. Human dental pulp stromal cells were obtained from human permanent premolars and deciduous teeth and cultured on MTA-coated culture plates. The cells were subjected to proliferation assay and cell cycle analysis. Their differentiation potential was evaluated by analysing changes in the mRNA expressions of runt-related transcriptional factor 2 (Runx2) and alkaline phosphatase (ALP). Morphological changes of cells in direct contact with MTA were observed using scanning electron microscopy (SEM). The proliferation rates, distribution of cell cycles and mRNA expression patterns of Runx2 and ALP were similar in both types of pulpal cells. SEM observations revealed that both types changed into more dendrite-like cells. On the surface of MTA, human dental pulp stromal cells from deciduous and permanent teeth were able to both proliferate and differentiate into cells that induce mineralization. MTA is suitable as a biocompatible pulpotomy medicament for primary teeth.

Relationship between Restoring Force and Typical Stroke with SMA Coil Spring in Electrosurgical Knee Wand (슬관절 수술용 전기소작완드에 적용되는 형상기억합금 코일스프링의 회복력 및 행정거리의 관계)

  • Yang, Young-Gyu;Han, Gi-Bong;Kim, Cheol-Woong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.12
    • /
    • pp.1301-1307
    • /
    • 2011
  • Electrosurgical knee wand (EKW) is a high-frequency thermocautery instrument and is often used for coagulation, ablation, excision, and extirpation of knee ligaments and tissues. In order to maximize the success rate, ease, and safety of knee surgery using EKW and radiofrequency ablation, it is necessary to ensure that the EKW selectively approaches the lesion with utmost accuracy and safety. The key feature of this instrument is its excellent maneuverability. Hence, the authors constructed a tensile spring model based on a shape memory alloy (SMA), which exhibits the shape memory effect. This model can be used in knee surgery as it is considered the most biocompatible femorotibial surgical actuator. The changes in external temperature with current and the thermoelectric characteristics of the SMA were investigated. The relationship between the restoring force and the typical stroke (TS) in response to the conditions in the SMA tensile spring design were evaluated. In conclusion, as the diameter of the SMA tensile spring decreased, the maximum temperature increased. The strain in the actuator caused a stable and proportional increase in the force and induced current for up to 15s, but this increase became very unstable after 30s. Moreover, the relationship between the current and the TS was more stable than that between the current and the restoring force.